Records from 1991 to 2008. Most recent: inspection, 15 July 2008.
Inspection history · 59
15 July 2008
Annual Inspection
Physical examination · Activities Europe · Activity 3263193
19 July 2007
Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3000183
6 September 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2771138
23 August 2006
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2771891
16 August 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750250
15 August 2006
Examination of Repairs · Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750039
19 July 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2718440
22 September 2005
Administrative Inspection · MARPOL Annex I Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2498663
15 June 2005
MTSA/ISPS Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2391875
23 September 2004
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2251136
10 May 2004
Internal Structural Exam · Re-Inspection · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2063789
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976374
7 August 2003
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1869387
22 July 2003
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1853769
22 November 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1711168
18 July 2002
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1648271
19 July 2001
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389439
15 July 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 185722
15 November 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 811181
15 November 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812655
5 May 1999
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375754
8 January 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809524
12 November 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372044
9 September 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762422
8 September 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 195361
2 September 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762477
30 July 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 194944
12 May 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762553
7 May 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 195360
4 February 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 768617
29 January 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 191090
8 January 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1103309
10 December 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1097658
24 October 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 194910
24 October 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753830
10 October 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1363812
3 September 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416387
1 March 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 885775
16 November 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355566
29 November 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1177482
27 October 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356883
24 October 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1172754
9 October 1994
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1175438
27 September 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 866286
27 September 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447388
9 August 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 861175
18 May 1994
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1169647
24 April 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443462
4 January 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370751
15 November 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429824
15 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 126366
15 September 1993
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366911
26 July 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 133158
16 February 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 832314
14 January 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439351
4 January 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1141429
17 October 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249211
17 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 940477
15 November 1991
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1269432
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 23 August 2008
Resolved
Conduct man overboard drills including rescue boat launch and provide documentation to coast guard monthly for the next 6 months.
Condition: Improper/Lack of Maintenance
Due 25 September 2008
Resolved 22 October 2014
Resolution: Received notification from CVC-1 that the vessel reflagged out of U.S. service to Kazakhstan
Stability › Watertight Integrity › General
Issued 23 August 2008
Resolved
Remove all locking eyelets from internal water tight doors and all tie back devices to ensure proper door closure in the event of fire/flooding. Cleared via email to be verified during next exam.
Condition: Improper/Lack of Maintenance
Due 7 September 2009
Resolved 22 October 2014
Resolution: Received notification from CVC-1 that the vessel reflagged out of U.S. service to Kazakhstan
Engineering › Bilge Water Management System › Pump
Issued 15 July 2008
Resolved
Remove all electric submersible pumps and associated PVC piping from the vessel. (ie shaft packing pumps and steering gear space). Cleared via email to be verified during next exam.
Condition: Placed in Improper Service
Due 7 September 2009
Resolved 22 October 2014
Resolution: Received notification from CVC-1 that the vessel had reflagged out of U.S. service to Kazakhstan .
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 15 July 2008
Resolved
Provide a complete Firesuit iaw vessels COI. Cleared via email to be verified during next exam.
Condition: Placed in Improper Service
Due 7 September 2009
Resolved 22 October 2014
Resolution: Received notification from CVC-1 that the vessel reflagged out of U.S. service to Kazakhstan
Engineering › Bilge Water Management System › Pump
Issued 15 July 2008
Resolved
Pump out excess dirty water under vessels generators. Cleared via email to be verified during next exam.
Condition: Improper/Lack of Maintenance
Due 7 September 2009
Resolved 22 October 2014
Resolution: Received notification from CVC-1 that the vessel reflagged out of U.S. service to Kazakhstan
Engineering › Steering Gear System › Hydraulic Hose
Issued 15 July 2008
Resolved
Repair Hydraulic leak on the port side steering line in rudder space.
Condition: Improper/Lack of Maintenance
Due 15 August 2008
Resolved 23 August 2008
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 15 July 2008
Resolved
Repair hydraulic leak on the anchor windlass.
Condition: Improper/Lack of Maintenance
Due 15 August 2008
Resolved 23 August 2008
Stability › Unintentional Flooding › General
Issued 15 July 2008
Resolved
Repair excessive clearances and water ingress on port rudder post. To be completed at next hull exam.
Condition: Damaged By Earlier Event
Due 7 September 2009
Resolved 22 October 2014
Resolution: Received notification from CVC-1 that the vessel reflagged out of U.S. service to Kazakhstan
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 15 July 2008
Resolved
Replace all chem lights on lifejackets with approved lights.
Condition: Placed in Improper Service
Due 15 August 2008
Resolved 23 August 2008
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 15 July 2008
Resolved
Prove proper operation of the windshield wipers on the vessel's bridge fore and aft.
Condition: Improper/Lack of Maintenance
Due 15 August 2008
Resolved 23 August 2008
Lifesaving › Lifebuoys › Approval
Issued 15 July 2008
Resolved
Provide Coast Guard approved life ring for stbd. bridge wing.
Condition: Placed in Improper Service
Due 15 August 2008
Resolved 23 August 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 July 2008
Resolved
Update the fire control plan to include fire suits and their location and submit to the coast guard for approval.
Condition: Improper/Lack of Maintenance
Due 15 August 2008
Resolved 22 October 2014
Resolution: Received notification from CVC-1 that the vessel reflagged out of U.S. service to Kazakhstan
Construction/Loadline › Penetrations › Gasket
Issued 15 July 2008
Resolved
Adjust engine room hatches to seal properly.
Condition: Improper/Lack of Maintenance
Due 15 August 2008
Resolved 23 August 2008
Engineering › Fuel Oil Service System › Filter
Issued 15 July 2008
Resolved
Remove petcocks on fuel oil filter flame bowls and install approved flame bowls where missing.
Condition: Design Flaw
Due 15 August 2008
Resolved 23 August 2008
Engineering › Fuel Oil Service System › Portable Fuel System
Issued 15 July 2008
Resolved
Repair fuel leaks on port and stbd. ship service generators.
Condition: Improper/Lack of Maintenance
Due 15 August 2008
Resolved 23 August 2008
Stability › Unintentional Flooding › General
Issued 15 July 2008
Resolved
Properly adjust port and starboard shaft packings.
Condition: Improper/Lack of Maintenance
Due 15 August 2008
Resolved 23 August 2008
Engineering › Fuel Oil Service System › Filter
Issued 23 August 2006
Resolved
Plug fuel filter valves on main engine.
Condition: Improper Installation
Due 7 October 2006
Resolved 18 July 2007
Resolution: Plugs were inserted in fuel filter valves.
Construction/Loadline › Structures › Superstructure
Issued 23 August 2006
Resolved
Make GPS antenna penetration watertight.
Condition: Improper/Lack of Maintenance
Due 7 October 2006
Resolved 18 July 2007
Resolution: GPS antennae watertight.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 August 2006
Resolved
Provide metal wire supports on wires and cables running to gantry.
Condition: Improper Installation
Due 7 October 2006
Resolved 18 July 2007
Resolution: Wire supports installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 August 2006
Resolved
COI expired 19July 2006, based on a review of vsl log, vsl was operating until 04AUG2006.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2006
Resolution: New COI issued following successful inspection.
Documentation › Certificates/Documents › IOPP Certificate
Issued 22 September 2005
Resolved
MARPOL I annual survey not conducted within specified time period of anniversary date.
Condition: Unknown
Due 22 September 2005
Resolved 22 September 2005
Resolution: Inspectors conducted satisfactory annual survey.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 22 September 2005
Resolved
Onboard fire-fighting SCBA was MSA, air cylinder installed was SCOTT, inappropriate for use due to valving configuration. Spare charge acceptable for use. Required vsl to provide additional MSA cylinder and remove SCOTT cylinder from vessel.
Condition: Unknown
Due 22 September 2005
Resolved 22 September 2005
Resolution: Vessel rep removed SCOTT cylinder from vessel and provided an MSA cylinder to replace.
Documentation
Issued 8 January 1997
Resolved
PROVIDE REVISED TONNAGE CERTIFICATE REFLECTING ADDITIONAL TONNAGE ADDED BY FRACTURING AND WELL STIMULATION TANKS/EQUIPMENT.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Documentation
Issued 10 October 1996
Resolved
PROVIDE A READMEASURED TONNAGE CERTIFICATE INCLUDING THE INDEPENDENT TANKS ON BOARD AS PART OF THE FRACTURING AND WELL STIMULATION EQUIPMENT.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Lifesaving
Issued 14 January 1993
Resolved
REPLACE/RENEW ALL PFD LIGHTS WITH SOLAS APPROVED LIGHTS. VSL IS NOT TO MAKE INTERNATIONAL VOYAGE UNTIL THIS REQUIREMENT HAS BEEN COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993