Records from 1986 to 2021. Most recent: inspection, 14 December 2021.
Documentation record
Registered dimensions (L × B × D)56.3 ft × 24.0 ft × 9.1 ft
Registered tonnagegross 123 / net 83
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRAYCO SHIPBUILDERS & RPRS · BOURG, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 December 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it83 - Regulatory (Subpart C or D), Net Ton
123 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
14 December 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7368710
30 August 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7306326
16 April 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7176248
9 March 2021
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7153612
6 April 2020
Initial Certification · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6935933
24 April 2018
Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6398105
19 September 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4987645
11 August 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4987565
22 January 2013
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4521061
23 August 2011
DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4125074
27 June 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2692909
29 July 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2444340
29 March 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2322156
8 April 2004
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2040513
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978449
29 November 2002
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1713638
13 June 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 140075
2 May 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 76411
5 December 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 410810
29 October 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 397024
17 January 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1509
17 January 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 222053
15 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 126366
6 September 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 114351
17 June 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 309769
10 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 308395
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 December 2021
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. The vessel relieved damage to approximately 3/4 of the superstructure after a collision with a barge and sank during Hurricane Ida.
46 CFR 137.120
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 June 2022
Resolution: The COI was surrendered and the vessel's status was changed to "laid up", the owner was informed to submit an application for inspection if they bring the vessel back into service.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 April 2021
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway.
Master and pilot did not conduct Navigation assessment prior to voyage which resulted in allision with another vessel. Provide proof of navigation assessments for last 2 voyages.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 16 April 2021
Resolved 16 April 2021
Resolution: Master provided navagation assesment for last 2 voyages.
Lifesaving › Thermal Protective Aids › General
Issued 5 December 1997
Resolved
VESSEL HAD LEAKY PIPE ON SEWAGE TANK.
Condition: Unknown
Due 5 February 1998
Resolved 23 August 2011
Construction/Loadline › Hull › Weld
Issued 5 December 1997
Resolved
VESSEL DID NOT HAVE OFFICIAL NUMBER PERMANENTLY MARKED ON HULL.
Condition: Unknown
Due 5 February 1998
Resolved 23 August 2011
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 5 December 1997
Resolved
VESSEL MUST AQUIRE ONE WORK VEST.
Condition: Unknown
Due 5 February 1998
Resolved 23 August 2011
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 December 1997
Resolved
VESSEL HAD NO US COAST PILOT ONBOARD.
Condition: Unknown
Due 5 February 1998
Resolved 23 August 2011
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 5 December 1997
Resolved
VESSEL DID NOT HAVE OIL TRANSFER PROCEDURES ONBOARD.
Condition: Unknown
Due 15 December 1997
Resolved 23 August 2011
Resolution: Not needed. Vsl has fuel cap. of 9800 gl
Lifesaving
Issued 17 June 1986
Resolved
PROVIDE MARKINGS "WORK VEST ONLY" ON ALL U.S. COAST GUARD APPROVED WORK VESTS(TYPE IV) IAW 46CFR26.30
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986
Fire Fighting
Issued 17 June 1986
Resolved
HAVE ALL CO2 FIRE EXTINGUISHERS HYDROSTATICALLY TESTED AS REQUIRED BY 46CFR25.30-20. 5-PORTABLE EXTINGUISHERS ON BOARD WERE OUT OF HYDRO-LAST HYDRO DATED 11/80.
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986
Documentation
Issued 17 June 1986
Resolved
PROVIDE AND POST FCC-RADIO STATION LICENSE ON BOARD IAW 47CFR83. PROVIDE A COPY FOR U.S. COAST GUARD MARINE SAFETY OFFICE PORT ARTHUR, TX.
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986
Engineering
Issued 17 June 1986
Resolved
PROVIDE A STANDARD DISCHARGE CONNECTION ON BOARD IAW 33CFR155.410(A)(3).
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986
Accommodation/Occupational Safety
Issued 17 June 1986
Resolved
THE VESSEL HAS INSTALLED TOILETS AND AN MSD, BUT THE OVERBOARD VALVE WAS LEFT OPEN ALLOWING RAW SEWAGE TO BE DISCHARGED AND MAKING THE MSD INOPER- ABLE IN VIOLATION OF 46CFR159.7
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986