Records from 1991 to 2011. Most recent: inspection, 4 February 2011.
Inspection history · 28
4 February 2011
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3935112
9 June 2010
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3760182
8 December 2009
Annual Inspection · Drydock Exam · Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3646688
13 February 2009
Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3417210
26 March 2008
Periodic Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3170214
30 March 2007
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2897101
19 January 2006
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2567958
20 April 2005
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2338606
17 March 2005
Internal Structural Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2310294
11 February 2004
Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2002902
7 February 2003
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1741525
5 April 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1600711
14 February 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1423514
1 March 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462820
24 March 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1113537
6 May 1998
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1409898
2 May 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 76411
23 April 1997
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1400557
26 August 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1090676
26 July 1996
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428669
26 July 1995
COI Inspection · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1353774
21 July 1995
Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1192685
7 September 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447382
26 July 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 866943
20 July 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379831
10 September 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 940387
18 October 1991
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1251291
8 August 1991
Initial Certification · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1252731
Construction/Loadline › Structures › Rake
Issued 26 March 2008
Resolved
Wasted area in the #1 Port side bilge knuckle and small puncture on the Port side transistion knuckle.
Condition: Unknown
Due 26 March 2008
Resolved 26 March 2008
Resolution: Replaced 6 ft x 8 ft insert on the Port side transition knuckle as well as replaced 2 ft x 13 ft insert on the # 1 Port side bilge knuckle. Witnessed satisfactory air tests for both repairs.
Stability › Weathertight Integrity › General
Issued 17 March 2005
Resolved
HOLES IN THE INTERNAL BULKHEADS INSIDE CARGO TANKS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2005
Resolution: All internal bulkheads were removed from open hopper and replaced with new steel bulkheads in accordance with original construction plans.
Construction/Loadline › Structures › Trunk
Issued 5 April 2002
Resolved
Cracked weld on port side trunk support. Repair facility effected proper repair on the spot.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 5 April 2002