R. J. PFEIFFER

R. J. PFEIFFER is a 1992 freight ship. The Coast Guard has recorded 142 inspections since 2016, most recently in April 2026, along with 59 deficiencies, 4 operational controls and 55 casualty investigations between 2005 and 2022.

Records from 2005 to 2026. Most recent: inspection, 9 April 2026.

Built
1992
Last inspected
9 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 April 2026
…with no type recorded19
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9002037
368156
Flag
UNITED STATES
Maury page id
psix-368156

Documentation record

Registered dimensions (L × B × D)671.5 ft × 105.7 ft × 66.5 ft
Registered tonnagegross 32,664 / net 10,846
ITC dimensions (L × B × D)671.5 ft × 105.7 ft × 66.5 ft
ITC tonnagegross 32,664 / net 10,846
BuilderNAT'L STEEL & SHIPBLDG CO · SAN DIEGO, CA, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 August 2026 · expires 31 August 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32664 - Convention (Subpart B), Gross Ton
10846 - Convention (Subpart B), Net Ton
28555 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

YU LIN Public Freight · MISLE 1423448 · 28 September 2016 · activity 6018090

Inspection history · 142

9 April 2026 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8345269
25 March 2026 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8332080
10 March 2026 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8324102
24 February 2026 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8315249
24 February 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8316713
19 February 2026 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8313560
10 February 2026 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8308754
13 January 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8295835
15 December 2025 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8283283
14 September 2025 MTSA/ISPS Verification · Annual Inspection · Deficiency Check · ACP COI Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8217114
9 July 2025 Administrative Inspection · Drydock Exam · In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8188489
31 May 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8148610
21 May 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8140730
15 May 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8136788
5 May 2025 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8129057
21 April 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8116462
24 March 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8098710
22 March 2025 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8099017
17 March 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8094936
8 March 2025 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8089554
26 February 2025 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8085133
30 January 2025 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8073075
10 October 2024 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8017210
27 September 2024 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8001667
11 September 2024 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8000999
7 September 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7996390
29 August 2024 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7996541
14 August 2024 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7983030
25 July 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7967219
16 July 2024 Explosive Handling Operation-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7959994
15 April 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7895763
6 April 2024 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7888149
18 March 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7881094
5 March 2024 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7874651
23 February 2024 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7867917
5 February 2024 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7861083
5 January 2024 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7845814
21 August 2023 Periodic Inspection · Deficiency Check · ACP Periodic Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7775659
15 July 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7747012
5 July 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7733708
26 June 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7723360
13 June 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7714496
10 June 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7714666
31 May 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7702091
27 May 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7701277
16 May 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7694389
15 May 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7688936
1 May 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7678918
6 April 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7663964
21 March 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7654470
13 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650381
10 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7649154
10 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7649158
6 March 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7646230
23 February 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7640965
7 February 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7633507
27 January 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7628132
11 January 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7620205
15 December 2022 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7609811
28 November 2022 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7600850
7 November 2022 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7591305
1 October 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7578990
1 September 2022 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7548901
1 August 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7522507
12 July 2022 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7505062
27 June 2022 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7488849
13 June 2022 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7476783
1 June 2022 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7477208
7 May 2022 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7445601
2 May 2022 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7442560
18 April 2022 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7433275
4 April 2022 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7424403
21 March 2022 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7415742
12 March 2022 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7407280
22 February 2022 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7400049
10 February 2022 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7394008
15 January 2022 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7378545
14 December 2021 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7368158
15 November 2021 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7351545
22 October 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7337755
4 October 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7326713
27 September 2021 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7321232
27 September 2021 Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7322073
10 September 2021 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7306717
7 September 2021 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7306780
24 August 2021 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7295224
10 August 2021 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7282630
3 August 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7276169
3 August 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7303563
26 July 2021 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7268297
17 May 2021 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7199685
4 May 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7189276
2 March 2021 ACP Additional Oversight – Risk Assessment
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7145883
2 March 2021 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7159331
14 January 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7124736
6 October 2020 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7072660
21 September 2020 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7062946
9 September 2020 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7054692
3 September 2020 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7056293
17 August 2020 ACP COI Oversight · Deficiency Check · COI Inspection · Re-Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7023638
28 July 2020 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7018438
14 July 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7005815
7 May 2020 Administrative Inspection · ACP Drydock Oversight
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6950122
21 January 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6892733
30 December 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6880803
26 December 2019 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6877967
24 October 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6873298
27 August 2019 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6798407
22 July 2019 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6732781
13 June 2019 Underwater Inspection in lieu of Drydock · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6762383
8 April 2019 ACP Additional Oversight – Risk Assessment
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6658960
1 April 2019 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6653768
29 January 2019 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6620603
13 August 2018 Administrative Inspection · Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6505347
28 July 2018 Damage Survey · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6502451
26 July 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6492725
14 April 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6397866
20 February 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6368659
15 February 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6356048
15 February 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6398467
12 February 2018 ACP Additional Oversight – Risk Assessment
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6354126
23 January 2018 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6342512
8 January 2018 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6352324
2 November 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6363563
1 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6299691
29 September 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6277929
17 July 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6199896
7 March 2017 ACP Additional Oversight – Risk Assessment · Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6100089
6 March 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6100077
21 December 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6182741
28 September 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6018090
26 September 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6018089
12 September 2016 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5999268
7 August 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6011104
1 August 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5947245
16 July 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6041974
7 June 2016 Drydock Exam · Internal Structural Exam · ACP Periodic Oversight · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 5885034
4 May 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5872090
18 April 2016 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5857192
29 March 2016 ACP Periodic Oversight
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5842507
22 March 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5839134
15 March 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5834738

Deficiency record · 59

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2026 Resolved
Whenever an accident occurs to a ship or a defect is discovered, either of which affects the safety of the ship or the efficiency or completeness of its lifesaving appliances or other equipment, the master or owner of the ship shall report at the earliest opportunity to the Administration, the nominated surveyor or recognized organization responsible for issuing the relevant certificate, who shall cause investigations to be initiated to determine whether a survey, as required by regulations 7, 8, 9 or 10, is necessary. Vessel Captain reported reoccurring faulty UPS affecting vessel automation. Vessel not authorized to run a periodically unattended machinery space when UPS is offline. Company is to notify classification society (ABS) and provide a cause and corrective action report.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: ABS Survey report received.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 14 September 2025 Resolved
The company should identify potential emergency shipboard situations, and establish procedures to respond to them. General instructions for fighting fires was not available. Firefighting manual was provided but was incomplete. When asked about general company policies for shipboard boundary cooling, overhaul of spaces, procedures for entering a space that a fixed CO2 system was used, none could be provided. Procedures for a hose team to attack a fire such as direct and indirect attack procedures were not available. Conduct an SMC audit on fire fighting procedures and instructions to be used for the vessel to establish updated procedures to respond to a fire. Complete corrective actions in 90 days.74 SOLAS (24) IX/3.1 ISM Code 8.1 ISM Code 8.2
Action required: 705 - Other - as specified
Due 14 December 2025
Resolved 23 October 2025
Resolution: ABS accepted as condition.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 14 September 2025 Resolved
The company shall establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements the company should ensure that inspections are held at appropriate intervals. During random sampling of parts identified in NSE, 2 of 5 items of the sample contained the incorrect number identified. Conduct an SMC audit on spare parts inventory. Complete corrective actions in 90 days.
Action required: 705 - Other - as specified
Due 14 December 2025
Resolved 23 October 2025
Resolution: ABS accepted as condition.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 14 September 2025 Resolved
The company shall establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements the company should ensure that inspections are held at appropriate intervals. Special Tools required for PSTP's were not calibrated. After review of NSE, special tools requiring calibration were not identified and being tracked. Calibrate required equipment and update SMS to ensure inspections of special tools are held at the appropriate interval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2025
Resolved 23 October 2025
Resolution: ABS accepted as condition.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 14 September 2025 Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea without danger to the ship or the persons on board. The life boat and rescue boat's sliding doors are unable to latch close resulting in visible gaps, and not allowing for a weather tight seal.74 SOLAS (24) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2025
Resolved 23 October 2025
Resolution: Life boat and rescue boat door were repaired satisfactory.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 14 September 2025 Resolved
A firefighter’s outfit shall consist of an axe to the satisfaction of the Administration. All firefighter’s outfits are not outfitted with and axe as required. 74 SOLAS (97) II-2/ 17.1.1.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2025
Resolved 23 October 2025
Resolution: Axes are outfitted with fire fighting suits.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 27 September 2024 Resolved
The international shore connection shall be kept aboard the ship together wiht a gasket. No gasket provided for port or starboard international shore connection. 74 SOLAS (97 Cons.) II-2/19.4 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2024
Resolved 10 October 2024
Resolution: Received ABS Class Report, WO 6636118 attesting to correction of missing gaskets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2024 Resolved
Lifebuoys complying with requirements of paragraph 2.1.1 fo the Code shall be so distributed as to be readily available on both sides of the ship. Five (5) lifebuoys were found unservicable with dry-rotted plugs compromising watertightness. 74 SOLAS (2020 Cons.) III/7.1 16a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 10 October 2024
Resolution: Received ABS Report WO 6636118 attesting to renewal of deficient lifebuoys.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 August 2023 Resolved
Fire resistance doors shall as far a practicable be equivalent to that of the division in which they are fitted. Doors required to be self-closing shall not be fitted with hold-back hooks. Class “A” doors in the galley and C deck baggage locker were fitted with hold backs. 74 SOLAS (97) II-2/47
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 15 September 2023
Resolution: Accepted by RO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 August 2023 Resolved
The machinery and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Two main engine expansion joints, 1 flexible joint adjacent to the auxiliary boiler and 1 bolted joint at the exhaust header, are failing and require renewal. 74 SOLAS (97) II-1/26
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 15 September 2023
Resolution: Accepted by RO.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 August 2023 Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least A-0 class divisions and be protected by self-closing doors at all levels. Main deck self-closing stairwell door would not full close. 74 SOLAS (97) II-2/46.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 15 September 2023
Resolution: Accepted by RO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Port steering gear motor support fractured at the port aft foot. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 15 September 2023
Resolution: Accepted by RO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2023 Resolved
Hydraulic power-operated steering gear shall be provided with the following: arrangements to maintain the cleanliness of the hydraulic fluid. Abandoned port and starboard mooring winch hydraulic control lines in steering space found leaking. 74 SOLAS (97) II-1/29.12.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 15 September 2023
Resolution: Accepted by RO.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 August 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Potable hot water supply line directly above the water heater found with cut pipe support and tie wire holding it in place. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 15 September 2023
Resolution: Accepted by RO.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 August 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Multi cable transit behind the door of the Navigation Equipment Locker space on the bridge is missing half of structural fire protection where it penetrates the A-60 deck below. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 15 September 2023
Resolution: Accepted by RO.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2023 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Starboard boat deck ladder well emergency lighting housing has broken latch and is being held in place with metal band. 74 SOLAS (97) II-1/40
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 15 September 2023
Resolution: Accepted by RO.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2023 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Two dead end wires found under port side A-Deck platform. 74 SOLAS (97) II-1/40
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 15 September 2023
Resolution: Accepted by RO.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 August 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Forty gallons of kerosene found stored in 5 gallon plastic jugs in the engine room. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 August 2023
Resolution: Excess oil removed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 August 2023 Resolved
Any required fixed fire detection shall be capable of immediate operation at all times. Smoke detector above lube oil purifier found covered in plastic. 74 SOLAS (97) II-2/13.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 August 2023
Resolution: Plastic removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 August 2023 Resolved
Doors provided to ensure the watertight integrity of internal openings which are used while at sea are to be sliding watertight doors capable of being remotely closed from the bridge...Indicators are to be provided at the control position showing whether the doors are open or closed. Open indicator on bridge for shaft alley WTD was inoperable. 74 SOLAS (97) II-1/25-9.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 August 2023
Resolution: Indicator bulb replaced.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 September 2022 Resolved
Vessel shall be equipped with a block diagram and operating instructions for remote steering. No diagram or remote operating procedures were available on the bridge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 30 September 2022
Resolution: ABS attended and verified correction.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 9 September 2022 Resolved
09SEP22: The rating of the overload circuit protection shall be indicated. The 24VDC Distribution circuit breaker panel located in the Emergency generator room has 2 breakers with inappropriate ratings. Emergency SWBD control and alarm DC6 is labeled for a 15AT breaker and installed with a 50 amp. Emergency SWBD control and alarm DC7 is labeled for a 50AT breaker and installed with a 15 amp.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 30 September 2022
Resolution: ABS attended and verified correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Stbd sea chest vent line holed. 74 SOLAS (20 cons) I/11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 September 2021
Resolved 27 September 2021
Resolution: Received photo showing replacement of pipe.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The emergency fire pump found with multiple fractures in the foundation. 74 SOLAS (20 cons) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2021
Resolved 28 September 2021
Resolution: Accepted by ABS
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 September 2021 Resolved
All steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the administration. Fractures found in the foundations for the port and stbd steering motors at the following locations: port motor outboard forward and aft corners- stbd pump aft outboard corner. 74 SOLAS (97 cons) II-1 Reg 29.2.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2021
Resolved 28 September 2021
Resolution: Accepted by ABS
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 27 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Hydraulic oil leak noted at the Quick Closing Valve for #2 LO Storage. 74 SOLAS (20 cons) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2021
Resolved 28 September 2021
Resolution: Accepted by ABS
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 September 2021 Resolved
Where penetrations of watertight bulkheads are necessary for electrical cables arrangements are to be made to maintain the watertight integrity. Modified multi cable transit found between the engine room and shaft alley. 74 SOLAS (97 cons) II-1 Reg 25-9.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2021
Resolved 28 September 2021
Resolution: Accepted by ABS
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Bridge emergency power breaker panel EP102 and main deck lighting panel L102 are not properly labeled for circuits they serve. Both panels list multiple spare switches that are energized. 74 SOLAS (20 cons) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2021
Resolved 28 September 2021
Resolution: Accepted by ABS
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 27 September 2021 Resolved
Each discharge operation shall be recorded in the Garbage Record Book. Between 12JUL21 – 19SEP21, six entries were made where discharges to reception facilities were recorded in the ‘into sea’ column which included plastics and e-wastes. Reception facility receipts corresponded to the quantities and dates where the six incorrect entries were made. Discussed discrepancies with [name withheld] who noted the error and will make entries in the proper column going forward. MARPOL Annex V/9
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 September 2021
Resolved 27 September 2021
Resolution: Conducted review with C/O on proper record book entries.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 2 March 2021 Resolved
Before the ship leaves and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Both port and stbd lifeboat kort nozzle fin and attachment bearings are damaged and seized in place.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2021
Resolution: Temporary repairs made to both STBD/PORT lifeboats. Recieved/reviewed class report.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 March 2021 Resolved
Fire protection system to ensure required performance to include structural fire protection. Aft inboard upper EDG insulation and sheet metal shall be repaired original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 March 2021
Resolution: See Class Report
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 2 March 2021 Resolved
Condition and equipment shall be maintained to surveyed condition. DG exhaust and bunker line lagging shall be repaired to original.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2021
Resolution: See Class Report
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 2 March 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Company should establish maintenance procedures that scrutinize the exterior condition and attachments on installed lifeboats.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 March 2021
Resolution: See Class Report
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 2 March 2021 Resolved
Before the ship leaves an at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Following an approved temporary repair to correct Item No. 1), Palfinger and ABS require a permanent repair of both port & starboard kort nozzle, kort nozzle attachment points, and installed fin.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 March 2021
Resolution: See Class Report
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 August 2020 Resolved
Fire-fighting systems and appliances shall be kept in good and working order and readily available for immediate use. Emergency fire pump unable to be started for adequate pressure. 74 SOLAS (2014) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 August 2020
Resolution: Corrected on the spot. MI team witnessed 9bar pressure from emergency fire pump with two hoses.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 17 August 2020 Resolved
Vessels in oceans service shall be fitted with hawsers in general agreement with Standards established by the American Bureau of Shipping. Bow spring mooring line discovered severely deteriorated. 46 CFR 96.07-5(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2020
Resolved 3 September 2020
Resolution: Vessel provided ABS Preliminary Report finding deficiency corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 August 2020 Resolved
No electrical equipment shall be installed unless the equipment is appropriatey certified for safe usage. Installed paint locker light discovered not intrinsically safe. 74 SOLAS (04) II-1/45.10.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2020
Resolved 3 September 2020
Resolution: Vessel provided ABS Preliminary Report #4424470 finding deficiency corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 August 2020 Resolved
All access openings in bulkheads shall be permanently and strongly attached to the bulkhead and secured with clamping devices. Latch mechanism on stbd side A-deck door discovered broken. ILLC Part 1, Annex I, Chapter II, Reg 12.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2020
Resolved 3 September 2020
Resolution: Vessel provided ABS Preliminary Report #4424470 finding deficiency corrected.
02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 17 August 2020 Resolved
For all hatchways in position 1 or 2 steel bars or other equivalent means shall be provided in order to efficiently and independently to secure each section of watchway covers. Sliding dogs discovered misaligned for portside Bay #43 and stbdside Bay #35 and bay #37. ILLC Part 1, Annex I, Chapter II, Reg 15.13
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2020
Resolved 3 September 2020
Resolution: Vessel provided ABS Preliminary Report #4424470 finding deficiency corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 August 2020 Resolved
After any survey of the ship has been completed, no change shall be made to the structure. Hatch dog for stbd generator one and two emergency escapes discovered loose. ILLC Part 1, Article 15
Action required: 10 - Deficiency Rectified
Resolved 17 August 2020
Resolution: Corrected on the spot. Verified all loose hatch dogs were tightened for appropriate closure.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 17 August 2020 Resolved
Openings in freeboard decks shall be protected by an enclosed superstructure of rquivalent strength and weathertightness. Lower ventilation opening for portside tunnel found with deteriorated lower knife edge. ILLC Part 1, Annex I, Chapter II, Reg 18.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2020
Resolved 3 September 2020
Resolution: Vessel provided ABS Preliminary Report #4424470 finding deficiency corrected.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 17 August 2020 Resolved
Doors provided to ensure watertight integrity of internal openings are to be sliding watertight doors with indicators provided at the control position showing whether the doors are open or closed. Open indicator light was out for watertight doors on bridge. 74 SOLAS (2004) II-1/25-9.3
Action required: 10 - Deficiency Rectified
Resolved 17 August 2020
Resolution: Corrected on the spot. Verified watertight door indicator light properly illuminated from the bridge.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 17 August 2020 Resolved
After any survey of the ship, no change shall be made in the structure, fittings, or arrangements. Discovered a missing coaming plug in stbd aft bay #46. MARPOL Annex 1, Reg 6.4.2
Action required: 10 - Deficiency Rectified
Resolved 17 August 2020
Resolution: Corrected on the spot. Verified replaced coaming plug in stbd aft bay #46 while on scene.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 July 2019 Resolved
74 SOLAS (97) II-2/47.1 The fire resistance of doors shall be equivalent to that of the division in which they are fitted. Self-closing doors from stairway on A and B deck did not close all the way. 15ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 22 July 2019
Resolved 25 July 2019
Resolution: Def cleared
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2019 Resolved
Fire hose at station #31 leaked from pressed fitting during drill. Hose destoryed and replaced by Ship's personnel.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2019
Resolution: Hose destoryed and replaced by Ship's personnel with onboard spares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2019 Resolved
Identified 3 dead end cables on bridge behind chart table.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2019
Resolution: Cables verified with no power and tagged for removal.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 April 2019 Resolved
Focsel hatch leading down to bosn stores had a grating with equipment stored on it. Restricting egress from bosn stores.
Action required: 10 - Deficiency Rectified
Resolved 8 April 2019
Resolution: Equipment and grating removed, Captain breifed and made aware of condition.
Engineering › Fuel Oil Service System › Valve, Control
Issued 12 February 2018 Resolved
Prove proper operation emergency fuel quick closing valves.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2018
Resolution: Verified proper operation of the Emergency Fuel Quick Closing Valves.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 12 February 2018 Resolved
Prove proper operation of number 1,2 and 4 engine ventilation supply closures.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2018
Resolution: Verified proper operation of the 1, 2, & 4 engine room ventilation supply closure
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 12 February 2018 Resolved
Conduct blowout of fixed fire fighting system piping. Remove any foreign matter to blow clear.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2018
Resolution: Recieved Class report attesting that the servicing company and ship conducted and will continue to conduct blow throughs on the C02 system.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 12 February 2018 Resolved
Prove proper operation of E/R natural exhaust ventilation closure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2018
Resolution: Verified proper operation of E/R natural exhaust ventilation closure.
Communications › Alarms/Indicators › General Alarm
Issued 12 February 2018 Resolved
Prove General Alarm activate in accordance with provisions outlined in SOLAS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2018
Resolution: Recieved Class Report, engineering crew altered the time delay, Class verified that the time delay was set back to 2 min. and is operating properly.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 12 February 2018 Resolved
Prove proper operation of the upper L/O purifier heater safety valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 13 August 2018
Resolution: Witnessed C/E manually test relief valve
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 12 February 2018 Resolved
Prove proper operation of the lower HFO purifier heater safety valves
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 13 August 2018
Resolution: Witnessed C/E manually test relief valve
Engineering › Fuel Oil Service System › Tank
Issued 2 November 2017 Resolved
Make permanent repairs to 5C HFO tank top at frame 70.
Action required: 705 - Other - as specified
Due 10 December 2017
Resolved 9 January 2018
Resolution: Repairs completed to the satisfaction of attending Class Surveyor. Class report attached under "Documents".
Engineering › Fuel Oil Service System › Tank
Issued 2 November 2017 Resolved
Verify proper operation of overflow arrangment for F/O system.
Action required: 703 - Prior to bunkering operations
Resolved 2 November 2017
Resolution: verified that approved design did not connect HFO tanks to overflow system.
Engineering › Fuel Oil Service System › Gauge
Issued 2 November 2017 Resolved
Replace tank level indicator for 5C HFO tank.
Action required: 703 - Prior to bunkering operations
Resolved 2 November 2017
Resolution: Determined vessel had disabled raw data input to TLI during M/E shutdown procedures, verified proper operation.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 July 2016 Resolved
Complete 100% satisfactory testing of Class approved Periodic Safety Test Procedures (PSTP) and Design Verification Test Procedures (DVTP) in presence of your ACS or Coast Guard Marine Inspectors. Until all issues related to deficiencies noted in the PSTP and/ or DVTP are rectified, the COI endorsement for periodically unattended machinery space operations (PUMS) is suspended. (See attached 835)
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 19 July 2016
Resolution: DVTP/PSTP approval and testing documentation was received with ABS endorsements
Engineering › Steering Gear System › Rudder
Issued 18 April 2016 Resolved
Make permanent repairs to steering gear rudder seals. (upper & lower)
Action required: 705 - Other - as specified
Due 18 July 2016
Resolved 12 August 2016
Resolution: Received ABS report for satisfactory permanent repairs.

Casualty record · 55

28 April 2005Routine · role: Involved in a Marine Casualty · activity 2466924
4 July 2005Routine · role: Involved in a Marine Casualty · activity 2431016
15 July 2005Routine · role: Involved in a Marine Casualty · activity 2431410
17 October 2006Routine · role: Involved in a Marine Casualty · activity 2803880
19 October 2006Routine · role: Involved in a Marine Casualty · activity 2807408
17 April 2009Routine · role: Involved in a Marine Casualty · activity 3454905
31 May 2009Routine · role: Involved in a Marine Casualty · activity 3511237
28 June 2009Routine · role: Involved in a Marine Casualty · activity 3518745
11 October 2009Routine · role: Involved in a Marine Casualty · activity 3615045
28 December 2009Routine · role: Involved in a Marine Casualty · activity 3860067
19 March 2010Routine · role: Involved in a Marine Casualty · activity 3701691
30 March 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3741546
29 April 2010Routine · role: Involved in a Marine Casualty · activity 3939006
27 May 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3860064
7 November 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3890009
1 February 2011Routine · role: Involved in a Marine Casualty · activity 3944902
13 February 2011Routine · role: Involved in a Marine Casualty · activity 3944868
17 February 2011Routine · role: Involved in a Marine Casualty · activity 3957036
18 March 2011Routine · role: Involved in a Marine Casualty · activity 3970163
20 March 2011Routine · role: Involved in a Marine Casualty · activity 3970476
19 October 2011Routine · role: Involved in a Marine Casualty · activity 4293665
23 October 2011Routine · role: Involved in a Marine Casualty · activity 4175176
20 December 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4217821
25 December 2011Routine · role: Involved in a Marine Casualty · activity 4222382
11 January 2012Routine · role: Involved in a Marine Casualty · activity 4234117
11 February 2012Routine · role: Involved in a Marine Casualty · activity 4243895
5 March 2012Routine · role: Involved in a Marine Casualty · activity 4257586
15 July 2012Routine · role: Involved in a Marine Casualty · activity 4382091
17 July 2012Routine · role: Involved in a Marine Casualty · activity 4471664
12 August 2012Routine · role: Involved in a Marine Casualty · activity 4433057
27 November 2012Routine · role: Involved in a Marine Casualty · activity 4495605
23 January 2013Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4521229
8 June 2013Routine · role: Involved in a Marine Casualty · activity 4627234
7 July 2013Routine · role: Involved in a Marine Casualty · activity 4677753
11 July 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4655526
14 August 2013Routine · role: Involved in a Marine Casualty · activity 4717138
1 September 2013Routine · role: Involved in a Marine Casualty · activity 4706286
23 September 2013Routine · role: Involved in a Marine Casualty · activity 4722879
28 November 2013Routine · role: Involved in a Marine Casualty · activity 4762284
11 August 2015Routine · role: Involved in a Marine Casualty · activity 5751419
22 March 2016Routine · role: Alleged Pollution Source · activity 5839134
4 May 2016Routine · role: Involved in a Marine Casualty · activity 5872090
16 July 2016Routine · role: Involved in a Marine Casualty · activity 6041974
7 August 2016Routine · role: Involved in a Marine Casualty · activity 6011104
26 September 2016Routine · role: Involved in a Marine Casualty · activity 6018089
28 September 2016Routine · role: Involved in a Marine Casualty · activity 6018090
21 December 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6182741
6 March 2017Routine · role: Involved in a Marine Casualty · activity 6100077
15 February 2018Routine · role: Involved in a Marine Casualty · activity 6398467
20 February 2018Routine · role: Involved in a Marine Casualty · activity 6368659
14 April 2018Routine · role: Involved in a Marine Casualty · activity 6397866
26 July 2018Routine · role: Involved in a Marine Casualty · activity 6492725
14 July 2020Routine · role: Involved in a Marine Casualty · activity 7005815
3 August 2021Routine · role: Involved in a Marine Casualty · activity 7303563
1 October 2022Routine · role: Involved in a Marine Casualty · activity 7578990
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.