Records from 1993 to 2025. Most recent: inspection, 22 May 2025.
Inspection history · 57
22 May 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8141645
14 May 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7912248
19 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7881604
9 May 2023
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7684554
25 August 2022
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7544146
19 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7510931
23 March 2022
COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7417259
21 August 2021
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7293838
17 August 2021
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7289379
27 May 2021
Simplified Stability Test
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7208323
20 November 2020
Construction Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7099320
17 August 2020
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7032742
13 May 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6952654
20 May 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6688935
21 May 2018
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6419967
15 March 2018
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6375909
24 May 2017
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6154633
23 May 2017
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6153136
22 August 2016
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5980059
26 April 2016
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5863066
11 August 2015
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5213631
19 August 2014
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4962270
5 May 2014
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4850777
22 May 2012
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4318452
19 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4227507
6 September 2011
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4140406
14 July 2011
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 4081699
7 September 2010
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3844963
9 September 2008
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3315812
22 May 2008
Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3208559
6 July 2007
COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2985958
19 September 2006
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2770499
22 February 2006
Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2590723
30 January 2006
Type not recorded
No type recorded · USCGC DAUNTLESS (WMEC 624) · Activity 2582371
28 September 2005
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2502285
2 February 2005
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 2300371
10 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2241433
27 September 2004
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2206183
23 March 2004
Hull Examination · Deficiency Check · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2029752
17 June 2003
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1818844
25 June 2002
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1635747
17 May 2001
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1471773
12 June 2000
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1424935
15 March 2000
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1384389
18 November 1999
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 1510001
22 July 1999
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1104389
1 June 1999
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1411889
22 May 1999
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 1509906
4 May 1999
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 1509893
1 June 1998
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1423029
10 June 1997
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1465317
12 June 1996
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1419624
14 June 1995
Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1382983
15 June 1994
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1458168
5 October 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 694702
29 September 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 111107
16 June 1993
Initial Certification · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 845468
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2025
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. MI observed fuel supply hose only suited for hydraulic service installed from the fuel filter to the engine. Replace hose with
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 28 May 2025
Resolution: Vessel owner submitted pictures of the 2 fuel supply hoses meeting the requirements of J-1942.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2024
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel is not equipped with an interconnected fire detection system. Vessel is required to install and interconnected fire detection system in compliance with 46 CFR 181.450 in the machinery room, passenger seating area and the vestibule forward of the machinery room. Vessel is restricted to limited coastwise not more than 20 miles until deficiency is cleared by USCG MI.
46 CFR 181.405 (c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2024
Resolution: MI inspection installation and operation of UL217 listed interconnected fire detection system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2024
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. Vessel does not have a 10-B:C portable extinguisher installed at the operating station. Install a portable 10-B:C fire extinguisher at the operating station to the satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2024
Resolution: MI observed installation of proper 10 B:C extinguisher at the operating station.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 August 2021
Resolved
A pre-engineered fixed fire extinguishing system must automatically shut down all engines that draw intake from within the protected space. Vessel owner could not prove to the inspector that the pre-engineered system could shut down the engines. Make necessary repairs to the satisfaction of a marine inspector proving that the system is capable of shutting down engines upon activation.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 17 September 2021
Resolved 18 August 2021
Resolution: Sat test of system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 August 2021
Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that a positive shutoff valve is installed at the hull penetration. A flexible hose may be used for the discharge line provided the hose does not penetrate any required watertight bulkhead. MI observed no positive shut off valves at the hull penetrations and observed a bilge discharge hose penetrating the aft engine room watertight bulkhead. Install positive shutoff valves at each bilge discharge hull penetration and install a mechanical through hull through the aft engine room bulkhead to the satisfaction of a marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 18 August 2021
Resolution: Installed positive shutoff valves at hull penetration
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 August 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate U.S. Coast Pilot [name withheld] List, and Tide Tables. Provide to a marine inspector, U.S. Coast Pilot [name withheld] List and Tide Tables.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 18 August 2021
Resolution: Ordered required publications.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 May 2017
Resolved
All 42 adult and 5 child (47 total) lifejackets are found to be in an unservicable condition.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2017
Resolution: 42 new adult and 8 new child size lifejackets purchased.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 7 September 2010
Resolved
None on board
Action required: 705 - Other - as specified
Due 17 September 2010
Resolved 9 September 2010
Resolution: Recieved
Navigation › Piloting/Steering › Marine Charts
Issued 7 September 2010
Resolved
Need to update charts
Action required: 705 - Other - as specified
Due 17 September 2010
Resolved 9 September 2010
Resolution: Recieved
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 September 2010
Resolved
Out of date
Action required: 705 - Other - as specified
Due 17 September 2010
Resolved 9 September 2010
Resolution: Recieved.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 September 2008
Resolved
Prior to operation repair/replace pre engineered fir suppression, system alarm, light and engine shutdown and reset.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2008
Resolution: System installed, and tested.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 September 2008
Resolved
Provide guards for MDEs.
Action required: 705 - Other - as specified
Resolved 25 September 2008
Resolution: Provided
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 9 September 2008
Resolved
Prove proper operation of SSB.
Action required: 705 - Other - as specified
Resolved 25 September 2008
Resolution: Provided tech report of bench test.
Documentation › Logs/Records
Issued 24 March 2004
Resolved
Provide evidence of training and record keeping. LEGACY COMPONENT DESC: Training log
Due 1 April 2004
Resolved 5 April 2004
Communications › Radio Communications
Issued 23 March 2004
Resolved
Provide evidence of EPIRB test and record keeping. LEGACY COMPONENT DESC: EPIRB
Due 1 April 2004
Resolved 5 April 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 23 March 2004
Resolved
Repair/replace retro tape and lights on life jackets. LEGACY COMPONENT DESC: Lights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Lifesaving › Visual Distress Signals (General)
Issued 23 March 2004
Resolved
Demonstrate proper operation of all waterlights. LEGACY COMPONENT DESC: Waterlights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Personnel › Certificates/Documents/Licenses
Issued 17 June 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 24 March 2004
Personnel › Training
Issued 17 June 2003
Resolved
PROVIDE EVIDENCE OF TRAINING AND RECORD KEEPING. 46 CFR 185.420
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 5 April 2004
Documentation › Logs/Records
Issued 17 June 2003
Resolved
PROVIDE EVIDENCE OF EPIRB TESTS AND RECORD KEEPING. 46 CFR 185.728 LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 5 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 17 June 2003
Resolved
INSTALL GUARD ON PORT MDE'S POWER TAKE OFF. 46 CFR 177.960 LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 24 March 2004
Engineering › Bilge Water Management System
Issued 17 June 2003
Resolved
INSTALL BILGE ALARMS IAW 46 CFR 152.530 IN RUDDER ROOM & SPACE WHERE SHAFTS PENETRATE THE HULL.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 24 March 2004
Operations/Management › Drills/Instruction
Issued 25 June 2002
Resolved
Conduct man overboard and fire drill to the satisfaction of the attending Coast Guard Marine Inspector.
Due 25 June 2002
Resolved 25 June 2002
Resolution: Item was cleared after conducting RIN on ACTION I
Engineering › Fuel Oil Service System
Issued 25 June 2002
Resolved
Double clamp main engine fuel line rubber hoses. LEGACY COMPONENT DESC: Hose
Due 25 July 2002
Resolved 11 September 2002
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 25 June 2002
Resolved
Attach deck hatches to the hull.
Due 25 July 2002
Resolved 11 September 2002
Engineering › Diesel Engine (propulsion-direct drive) › Valve, Control
Issued 25 June 2002
Resolved
Demonstrate operation of starboard side main engine fuel shutdown from pilot house.
Due 25 July 2002
Resolved 25 June 2002
Resolution: Corrected after RIN on the ACTION I
Engineering
Issued 1 June 1999
Resolved
Install flame shields on both MDE Racor fuel oil filter assemblies.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Documentation
Issued 1 June 1999
Resolved
Obtain proper regulations, including sub-chapter "t".
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Lifesaving
Issued 1 June 1999
Resolved
Complete man overboard drill to the satisfaction of the attending marine inspectior.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Documentation
Issued 1 June 1999
Resolved
Provide Proof of valid Red Cross/CPR training for 50 % of crew.
Condition: Unknown
Due 1 August 1999
Resolved 16 June 1999
Lifesaving
Issued 1 June 1999
Resolved
Install reflective tape on both ring bouys.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Fire Fighting
Issued 1 June 1999
Resolved
Install smoke detection system.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999