MAURY USCG vessel records
← All vessels

ACTION IV

ACTION IV is a 1964 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in May 2025, along with 7 deficiencies and 1 casualty investigation in 2004.

Records from 2004 to 2025. Most recent: inspection, 22 May 2025.

Built
1964
Last inspected
22 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 May 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD3764
369326
Flag
UNITED STATES
Maury page id
psix-369326

Documentation record

Registered dimensions (L × B × D)51.5 ft × 14.3 ft × 7.5 ft
Registered tonnagegross 37 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNITED BOATBUILDERS INC · BELLINGTON, WA, UNITED STATES · built 1964
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 28 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Simplified, Gross Ton
29 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

22 May 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8141645
14 May 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7912248
19 March 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7881604
9 May 2023 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7684554
25 August 2022 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7544146
19 July 2022 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7510931
23 March 2022 COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7417259
21 August 2021 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7293838
17 August 2021 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7289379
27 May 2021 Simplified Stability Test
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7208323
20 November 2020 Construction Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7099320
17 August 2020 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7032742
13 May 2020 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6952654
20 May 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6688935
21 May 2018 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6419967
15 March 2018 Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6375909
24 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6154633
23 May 2017 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6153136
22 August 2016 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5980059
26 April 2016 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5863066

Deficiency record · 7

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2025 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. MI observed fuel supply hose only suited for hydraulic service installed from the fuel filter to the engine. Replace hose with
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 28 May 2025
Resolution: Vessel owner submitted pictures of the 2 fuel supply hoses meeting the requirements of J-1942.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2024 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel is not equipped with an interconnected fire detection system. Vessel is required to install and interconnected fire detection system in compliance with 46 CFR 181.450 in the machinery room, passenger seating area and the vestibule forward of the machinery room. Vessel is restricted to limited coastwise not more than 20 miles until deficiency is cleared by USCG MI. 46 CFR 181.405 (c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2024
Resolution: MI inspection installation and operation of UL217 listed interconnected fire detection system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2024 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. Vessel does not have a 10-B:C portable extinguisher installed at the operating station. Install a portable 10-B:C fire extinguisher at the operating station to the satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2024
Resolution: MI observed installation of proper 10 B:C extinguisher at the operating station.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 August 2021 Resolved
A pre-engineered fixed fire extinguishing system must automatically shut down all engines that draw intake from within the protected space. Vessel owner could not prove to the inspector that the pre-engineered system could shut down the engines. Make necessary repairs to the satisfaction of a marine inspector proving that the system is capable of shutting down engines upon activation.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 17 September 2021
Resolved 18 August 2021
Resolution: Sat test of system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 August 2021 Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that a positive shutoff valve is installed at the hull penetration. A flexible hose may be used for the discharge line provided the hose does not penetrate any required watertight bulkhead. MI observed no positive shut off valves at the hull penetrations and observed a bilge discharge hose penetrating the aft engine room watertight bulkhead. Install positive shutoff valves at each bilge discharge hull penetration and install a mechanical through hull through the aft engine room bulkhead to the satisfaction of a marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 18 August 2021
Resolution: Installed positive shutoff valves at hull penetration
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 August 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate U.S. Coast Pilot [name withheld] List, and Tide Tables. Provide to a marine inspector, U.S. Coast Pilot [name withheld] List and Tide Tables.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 18 August 2021
Resolution: Ordered required publications.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 May 2017 Resolved
All 42 adult and 5 child (47 total) lifejackets are found to be in an unservicable condition.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2017
Resolution: 42 new adult and 8 new child size lifejackets purchased.

Casualty record · 1

10 November 2004Routine · role: Involved in a Marine Casualty · activity 2241433
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.