MAURY USCG vessel records Sign in
← All vessels

SUN DREAM

SUN DREAM is a 1978 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1981, most recently in September 2025, along with 119 deficiencies and 2 casualty investigations between 2004 and 2021.

Records from 1981 to 2025. Most recent: inspection, 4 September 2025.

Built
1978
Last inspected
4 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC7501
Flag
UNITED STATES
367072280
Maury page id
psix-49880

Inspections, by type

…with no type recorded17
Years with a record 41 calendar years (1981–2025)
The 86 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)109.6 ft × 22.0 ft × 4.1 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSWIFTSHIPS INC · MORGAN CITY LA · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC7501MMSI 367072280 · active · compulsorily equipped · granted 4 December 2025, expires 19 October 2035
WCP5242MMSI not assigned · expired · compulsorily equipped · granted 27 December 1994, cancelled 26 February 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ACTION IV Passenger (Inspected) · MISLE 369326 · 10 November 2004 · activity 2241433

Inspection history · 86

4 September 2025 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8227078
10 January 2025 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8062278
11 January 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7854296
15 September 2023 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7792326
2 May 2023 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7683377
11 October 2022 Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7574821
6 January 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7376272
21 November 2021 Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7355387
21 November 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7356470
9 September 2021 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7308046
19 November 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7098281
8 January 2020 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6883664
1 November 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6847049
5 September 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6803734
8 January 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6605490
11 October 2017 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6285260
6 September 2017 Drydock Exam · Re-Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6259939
28 October 2016 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6058181
24 October 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6028780
20 October 2015 Internal Structural Exam · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5746273
1 September 2015 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5231868
3 January 2012 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4217712
10 August 2011 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4111099
25 October 2010 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3870315
22 July 2009 Hull Examination · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3542267
28 October 2008 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3352413
17 October 2007 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3076724
11 July 2007 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2990847
5 October 2006 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2802417
3 October 2005 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2506566
28 July 2005 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2442678
7 February 2005 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2288104
5 January 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2269207
17 November 2004 Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2246255
10 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2241433
21 October 2004 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2224975
29 September 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1916058
22 July 2003 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1853811
20 February 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1746909
22 October 2002 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1693188
4 February 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1483751
8 January 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1476207
31 July 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1441884
26 October 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1443090
1 November 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1441580
8 September 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 783723
3 August 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 776969
27 July 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1401048
23 April 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1423168
30 October 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1375543
22 December 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1116332
4 November 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 782080
30 July 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 780883
20 November 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 867282
8 November 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1170460
24 September 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1137743
8 November 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1184945
21 July 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1192422
18 November 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1152526
23 November 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 848258
21 July 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1153050
13 January 1993 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1447206
9 January 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 3272
18 December 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1141740
23 November 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 828982
8 October 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 667831
2 October 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 142702
2 October 1992 MARPOL Annex II Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1432628
29 January 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 944374
29 January 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1262953
29 January 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1263651
27 January 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1264693
2 December 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1250630
30 November 1990 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1246961
24 May 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 935431
28 October 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1207310
8 December 1988 Plan Review "T" Boat · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890555
14 May 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1302376
11 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292170
5 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291695
9 October 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283505
27 September 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283667
24 March 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1281368
28 September 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275187
29 September 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964128
25 September 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965142

Deficiency record · 119

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 November 2020 Resolved
each ring life buoy must be in accordance with 46 CFR 160.050. ring life buoy was cracked and needs replacement. 46 CFR 180.30-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2020
Resolved 20 November 2020
Resolution: received email that condition was rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2020 Resolved
Handle broken off circuit breaker switch for the #2 hydraulic pump on main switch board in E/R. Replace circuit breaker.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 January 2020
Resolution: Breaker switch replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 January 2020 Resolved
No fire hazards shall exist. Starboard main turbo is loose and leaking oil. Tighten bolts and ensure no oil leaks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2020
Resolution: Marine inspector tested the engine and observed no signs of leakage.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 January 2020 Resolved
Fire pump’s minimum capacity shall be 50 gallons per minute at 60 psi. The sea suction for fire pump is clogged obstructing the pump’s flow. Clear clogged sea suction.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2020
Resolution: The sea suction was cleared, pump tested and holds required pressure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2020 Resolved
Battery chargers were shorted out by raw water pump leak. Replace battery chargers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 January 2020
Resolution: Representative from the vessel replaced battery charger.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2020 Resolved
Exhaust piping must be gas tight. Repair exhaust leak off starboard main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2020
Resolution: Exhaust leaked repaired, no leakage present.
Lifesaving › Lifebuoys › Serviceable
Issued 24 October 2016 Resolved
Renew ring buoy on uppermost deck. -46CFR180.70
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Resolution: Replaced ring buoy.
Lifesaving › Lifebuoys › Serviceable
Issued 24 October 2016 Resolved
Renew grab line on ring buoy aft second deck. -46CFR180.70
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Resolution: Replaced line on ring buoy aft second deck.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 October 2016 Resolved
Renew guard screens on port and stbd ventilation motors.
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Resolution: Replaced screens on port and stbd ventilation motors.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 October 2016 Resolved
Clean and inspect stbd side ventilation trunk.
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Resolution: Ventilation motor trunk cleaned.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 October 2016 Resolved
Provide cover for outlet in crew room.
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Resolution: Outlet cover provided in crew room.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 October 2016 Resolved
Make permanent-type connections on port generator batteries. Alligator clips currently connected. -46CFR183.05-20
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Resolution: Permanent-type connections replaced alligator clips on port generator batteries.
Fire Fighting › Fire Pumps › Pressure
Issued 24 October 2016 Resolved
Provide repair proposal for fire pump (small leak on discharge connection and gauge reading 40 psi). Observed steady stream from hydrant.
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 October 2015 Resolved
Replace lanyard to ring life buoy floating water-light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 3 November 2015
Resolution: Verified renewed lanyard properly spliced to ring buoy.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 October 2015 Resolved
Replace battery to ring life buoy floating water-light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 3 November 2015
Resolution: Verified battery has been renewed by operator.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 20 October 2015 Resolved
Nav. Rules book onboard is Charlie edition. Provide onboard up-to-date copy of Nav. Rules (August 2014).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 3 November 2015
Resolution: Verified current edition of navigation rules and regulations hand book on board.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 20 October 2015 Resolved
Secure cable to forepeak high water alarm.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 3 November 2015
Resolution: Verified cable propely secured.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 20 October 2015 Resolved
Correct sticking of fore peak high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 3 November 2015
Resolution: Operator renewed high water alarm in fore peak.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 October 2015 Resolved
Properly terminate wires to high water alarm in forepeak.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 3 November 2015
Resolution: Verified wire terminations satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 October 2015 Resolved
Properly terminate wires to high water alarm in water tank compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 3 November 2015
Resolution: Verified wire terminations sealed satisfactorily.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 20 October 2015 Resolved
Remove debris from forepeak bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 3 November 2015
Resolution: Verified debris removed from bilge.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 October 2015 Resolved
Seal aft bulkhead in water tank compartment at wire penetration.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 3 November 2015
Resolution: Verifed wire penetrations sealed.
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 20 October 2015 Resolved
Provide locking device to oven door.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 3 November 2015
Resolution: Verified locking device installed on oven door.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 20 October 2015 Resolved
Label emergency escape hatch and adjust hatch to allow egress from engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2015
Resolved 3 November 2015
Resolution: Verified signage and means of ergress.
Construction/Loadline › Structures › Machinery Space Opening
Issued 20 October 2015 Resolved
Complete weld in engine room around emergency escape scuttle.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2015
Resolved 3 December 2015
Resolution: Weld repair completed.
Construction/Loadline › Hull › Transverse Frame
Issued 20 October 2015 Resolved
Repair cracked transverse frame, #4 frame from forward bulkhead, in bow thruster space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2015
Resolved 3 December 2015
Resolution: Weld repair completed.
Construction/Loadline › Hull › Transverse Frame
Issued 1 September 2015 Resolved
Second frame port side forepeak has a cracked weld leading into floating frame.
Action required: 705 - Other - as specified
Resolved 4 September 2015
Resolution: Sat repairs completed and reviewed to satisfaction.
Construction/Loadline › Hull › Hull Plating
Issued 1 September 2015 Resolved
Forward port side bow void has a quarter inch hole penetrating the hull. Repair proposal to be provided.
Action required: 705 - Other - as specified
Resolved 4 September 2015
Resolution: Repairs have been completed to satisfaction.
Engineering › Bilge Water Management System › Piping
Issued 15 August 2011 Resolved
Test all bilge pick-up/suction lines at next annual in the presence of a USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 1 November 2011
Resolved 17 October 2011
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 15 August 2011 Resolved
Provide approved plan showing aft ballast tanks are "potable water tanks"
Action required: 705 - Other - as specified
Due 1 November 2011
Resolved 17 October 2011
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 15 August 2011 Resolved
Show that vessel meets EPA vessel general permit requirements and CG-543 policy letter 11-01 prior to next Annual Exam (Oct, 2011).
Action required: 705 - Other - as specified
Due 1 November 2011
Resolved 17 October 2011
Deck/Cargo › Ballast › Tank
Issued 10 August 2011 Resolved
Make permanent repairs to #3 compartment STBD ballast tank outboard side wall approx mid tank. Tank has small holes due to localized corrosion
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2011
Deck/Cargo › Ballast › Tank
Issued 10 August 2011 Resolved
Provide repair proposal for holed ballast tank prior to repair, for review and approval by USCG Sector Miami.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2011
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 25 October 2010 Resolved
Clean galley range hood and make available fo inspection.
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 8 November 2010
Resolution: Thoroughly cleaned galley range hood of all grease.
Electrical › Electrical Distribution System (service) › Cable
Issued 25 October 2010 Resolved
Properly install fwd bilge pump cable. All spliced connections must be in an approved junction box.
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 8 November 2010
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 25 October 2010 Resolved
Label all circuit breakers in the Fwd E/R distribution panel.
Action required: 705 - Other - as specified
Due 25 October 2010
Resolved 8 November 2010
Resolution: Labeled all circuit breakers within Fwd E/R distribution panel.
Engineering › Bilge Water Management System › Interface Detector
Issued 25 October 2010 Resolved
Repair and prove proper operation of forward peak bilge indicator.
Action required: 705 - Other - as specified
Due 25 October 2010
Resolved 8 November 2010
Resolution: Repaired and proved proper operation of fwd peak bilge high level indicator.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 25 October 2010 Resolved
Provide approved electrical matting in way of ship service switchboard.
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 8 November 2010
Resolution: Provided approved electrical matting for ship service switchboard.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 22 July 2009 Resolved
Provide repair proposal for fracture in bulkhead IWO #2 transverse frame in port side water void.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2009
Construction/Loadline › Hull › Bottom Plating
Issued 22 July 2009 Resolved
Provide repair proposal for 1/4'' hole in port side sponsan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2009
Engineering › Sea-water System (primary cooling) › Valve
Issued 22 July 2009 Resolved
Provide repair proposal for sea chest thru hull valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2009
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 22 July 2009 Resolved
Replace port and starboard cutlass bearings due to over 50% wastage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2009
Engineering › Sea-water System (primary cooling) › Valve
Issued 22 July 2009 Resolved
Replace AC and forward generator thru hull valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 October 2007 Resolved
Provide updated charts and lit list.
Due 24 October 2007
Resolved 24 October 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 October 2007 Resolved
Properly paint navigation light shields mat black.
Due 24 October 2007
Resolved 24 October 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 October 2007 Resolved
Provide lens covers for anchor, all around, port and starboard nav lights IAW CLOREGS.
Due 24 October 2007
Resolved 24 October 2007
Lifesaving › Lifebuoys › Serviceable
Issued 17 October 2007 Resolved
Provide proper life ring in pilot house.
Due 24 October 2007
Resolved 24 October 2007
Construction/Loadline › Hull › Side Shell
Issued 11 July 2007 Resolved
Drill stop, grind down and weld all areas on Port/Stbd exhaust tube. If area will require to be cropped out submit repair proposal.
Action required: 705 - Other - as specified
Due 31 July 2007
Resolved 19 July 2007
Stability › Watertight Integrity › General
Issued 11 July 2007 Resolved
Make storage room forward bulkhead stbd side watertight.
Action required: 705 - Other - as specified
Due 31 July 2007
Resolved 11 July 2007
Stability › Watertight Integrity › General
Issued 11 July 2007 Resolved
Make engine room forward bulkhead watertight and fire resistant.
Action required: 705 - Other - as specified
Due 31 July 2007
Resolved 19 July 2007
Stability › Watertight Integrity › General
Issued 11 July 2007 Resolved
Replace gaskets on water ballast voids hatches.
Action required: 705 - Other - as specified
Due 31 July 2007
Resolved 19 July 2007
Engineering › Bilge Water Management System › Strainer
Issued 5 October 2006 Resolved
Galley Bilge Section missing strainer on Port and STBD sides.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 14 October 2006
Construction/Loadline › Penetrations › Pipe Flange
Issued 5 October 2006 Resolved
Plastic Through Hull fitting on STBD side. Replace with metal, same as hull strength. Replace at next Dry Dock.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 17 October 2007
Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 5 October 2006 Resolved
Ground indicator detecting stray Ground on vsl.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 14 October 2006
Documentation › Certificates/Documents › FCC SSL
Issued 28 September 2005 Resolved
Provide vessel's FCC Station License.
Action required: 705 - Other - as specified
Due 10 October 2005
Resolved 18 October 2005
Resolution: Received Fax confirmation.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 28 September 2005 Resolved
Provide complete First Aid Kit IAW 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 10 October 2005
Resolved 18 October 2005
Resolution: Received Fax confirmation.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 28 September 2005 Resolved
Remove Surge protector mounted on the bulkhead of the pilothouse.
Action required: 705 - Other - as specified
Due 10 October 2005
Resolved 18 October 2005
Resolution: Received Fax confirmation.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 28 September 2005 Resolved
Secure sewage overboard discharge valve.
Action required: 705 - Other - as specified
Due 10 October 2005
Resolved 18 October 2005
Resolution: Received Fax confirmation.
Stability › Watertight Integrity › General
Issued 28 September 2005 Resolved
Prove proper operation of engine room door alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2005
Resolved 29 September 2005
Resolution: Received fax from [name withheld] correcting deficiency.
Construction/Loadline › Structures › Superstructure
Issued 17 November 2004 Resolved
Make permenent repairs to windows at starboard aft 2nd deck.
Due 17 December 2004
Resolved 27 July 2005
Construction/Loadline › Structures › Superstructure
Issued 10 November 2004 Resolved
Make proper repairs to damage along starboard side of vessel. Submit repair proposal prior to commencing work.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2004
Resolved 17 November 2004
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 10 November 2004 Resolved
Provide diver report on condition of running gear.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2004
Resolved 10 November 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 October 2004 Resolved
Provide lifeline for one ring buoy in accordance with 46 CFR 180.70(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 October 2004 Resolved
Provide first aid kit in accordance with 46 CFR 184.710
Due 21 November 2004
Resolved 17 November 2004
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 21 October 2004 Resolved
Clean grill exhaust hood.
Due 21 November 2004
Resolved 17 November 2004
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 21 October 2004 Resolved
Provide outlet cover port side in galley.
Due 21 November 2004
Resolved 17 November 2004
Engineering › Bilge Water Management System › Piping
Issued 21 October 2004 Resolved
Install pipe caps on keel cooler lines no longer in use.
Due 21 November 2004
Resolved 17 November 2004
Electrical › Electric Supply System (service) › Cable
Issued 21 October 2004 Resolved
Properly mount shore tie cable in engine room portside.
Due 21 November 2004
Resolved 17 November 2004
Fire Fighting › Fire Main › Condition
Issued 21 October 2004 Resolved
Make permenent repairs to fire main piping where holed in coupling port side forward of engine room bullkhead.
Due 1 November 2004
Resolved 17 November 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 21 October 2004 Resolved
Provide current and correct FCC radio call sign.
Due 21 November 2004
Resolved 17 November 2004
Navigation › Piloting/Steering › Marine Charts
Issued 21 October 2004 Resolved
Provide nautical publications or equilvant in accordance with 46 CFR 184.420.
Due 21 November 2004
Resolved 17 November 2004
Construction/Loadline › Penetrations
Issued 22 July 2003 Resolved
MAKE PIPE PENERTRATIONS IWO STBD FWD ENGINE ROOM BLKD WATERTIGHT. LEGACY COMPONENT DESC: PIPE
Action required: 705 - Other - as specified
Due 24 July 2003
Resolved 24 July 2003
Electrical › Electric Generation Source (service) › Generator
Issued 21 October 2002 Resolved
Provide S/S generator with a 50 degree C ambient temperature rating or derate to 80% or demonstrate ambient temperature does not exceed 40 degress C. LEGACY COMPONENT DESC: Generator
Condition: Placed in Improper Service
Due 30 June 2003
Resolved 17 November 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 21 October 2002 Resolved
Provide a means for gaging F/O tanks. Blank off F/O sounding tube in accommodation space. LEGACY COMPONENT DESC: Gauge
Condition: Placed in Improper Service
Due 15 November 2002
Resolved 20 February 2003
Communications › Audible Communications
Issued 21 October 2002 Resolved
Provide PA speakers in all accommodation spaces. LEGACY COMPONENT DESC: PA system
Condition: Placed in Improper Service
Due 15 November 2002
Resolved 20 February 2003
Engineering › Fuel Oil Service System
Issued 8 January 2002 Resolved
Replace missing flame guard for Raycor fuel filter on Port MDE. LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Due 22 January 2002
Resolved 1 February 2002
Engineering › Generator (propulsion-electric)
Issued 8 January 2002 Resolved
Identify and repair leak fm bow thruster unit located on the main generator.
Condition: Unknown
Due 8 February 2002
Resolved 1 February 2002
Navigation
Issued 26 October 2000 Resolved
Steering compartment used for stowage of lumber, tiles etc. Remove same
Condition: Unknown
Due 27 October 2000
Resolved 30 October 2000
Lifesaving
Issued 26 October 2000 Resolved
Conduct firefighting and man overboard drills
Condition: Unknown
Due 27 October 2000
Resolved 30 October 2000
Accommodation/Occupational Safety
Issued 26 October 2000 Resolved
Inadequate ventilation for bathroom in stateroom.
Condition: Unknown
Due 27 October 2000
Resolved 30 October 2000
Navigation
Issued 26 October 2000 Resolved
Safety chain on Rudder is tight and it appears rudder has slipped. Remove chain and demonstrate operation of rudder.
Condition: Unknown
Due 27 October 2000
Resolved 30 October 2000
Lifesaving
Issued 26 October 2000 Resolved
Missing Required number of PFD's
Condition: Unknown
Due 27 October 2000
Resolved 30 October 2000
Electrical
Issued 27 July 1999 Resolved
REMOVE OR PROVIDE TERMINAL BOX FOR ENGINE ROOM DEAD END WIRE, AFT BULKHEAD.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Documentation
Issued 27 July 1999 Resolved
PROVIDE COPY OF UPDATED FCC RADIO OPERATOR'S LICENSE.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Construction/Loadline
Issued 30 October 1998 Resolved
MAKE ENGINE ROOM FORWARD HATCH WATERTIGHT
Condition: Unknown
Due 30 October 1998
Resolved 30 October 1998
Navigation
Issued 30 October 1998 Resolved
PROPERLY POSITION NAVIGATIONAL SIDELIGHT BULBS AND ANCHOR LIGHT BULBS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1998
Resolved 30 October 1998
Electrical
Issued 30 October 1998 Resolved
PROVIDE MARINE TYPE HOSE AT GENERATOR OUTFLOW_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1998
Resolved 30 October 1998
Construction/Loadline
Issued 4 November 1997 Resolved
FIT BOTH BILGE MANIFOLDS WITH A SELF PRIMING BILGE PUMP.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Fire Fighting
Issued 4 November 1997 Resolved
PROVIDE RUBBER LINED FIREHOSES FOR BOTH STATIONS.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Electrical
Issued 8 November 1996 Resolved
PROVED A BATTERY DISCONNECT SWITCH FOR EACH STARTER MOTOR.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Unknown
Issued 8 November 1996 Resolved
PROVIDE A PLACARD DETAILING VALVE ALIGNMENT FOR FIRE AND BILGE PUMP OPERATION.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Engineering
Issued 8 November 1995 Resolved
REPLACE FLEXIBLE FUEL LINE #2 GEN ENG.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Navigation
Issued 8 November 1995 Resolved
PROPERLY POSITION VESSEL NAV LIGHTS.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Lifesaving
Issued 8 November 1995 Resolved
PROVIDE SUFFICIENT ANCHOR LINE & CHAIN.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Fire Fighting
Issued 8 November 1995 Resolved
PROVIDE PORTABLE HAND FIRE PUMP.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Engineering
Issued 8 November 1995 Resolved
PROVIDE PROPER FLAME SCREEN FOR FUEL TANK VENTS.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Navigation
Issued 8 November 1995 Resolved
PROVIDE PROPER BULB FOR ANCHOR LIGHT.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Construction/Loadline
Issued 8 November 1995 Resolved
REMOVE OIL PADS FROM BILGES.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Construction/Loadline
Issued 8 November 1995 Resolved
REPAIR HOLE WHERE MARKED, PORT SIDE ENGINE ROOM NEAR GENSET.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Engineering
Issued 8 November 1995 Resolved
REPAIR GOVERNOR/FREQ AND PROVE PROPER OPERATION ON #1 GEN SET.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Documentation
Issued 23 November 1993 Resolved
PROVIDE DRUG TESTING PROGRAM IN COMPLIANCE W/ 46CFR16_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 November 1993
Resolved 23 November 1993
Deck/Cargo
Issued 23 November 1992 Resolved
REPAIR OIL LEAKS FROM INBOARD PIPING ELBOWS TO HYDRAULIC PUMPS FOR BOW THRUSTER LOCATED W/I BOW THRUSTER PUMP VOID BENEATH GALLEY AREA._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Electrical
Issued 23 November 1992 Resolved
REMOVE OLD BATTERY LOCATED ON DECK (FWD PORT SIDE OF ENGINE ROOM)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Fire Fighting
Issued 23 November 1992 Resolved
PROVIDE PROPER HOSE NOZZLE FOR AFT FIRE STATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Electrical
Issued 23 November 1992 Resolved
CAP HOLES (3) FOR CABLE RUNS IN TOP OF MAIN SWITCHBOARD LOCATED IN ENGINE ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Construction/Loadline
Issued 23 November 1992 Resolved
PROVIDE PROPER SUPPORT FOR ENGINE ROOM DECK PLATE OVER STARBOARD TAILSHAFT (OUTBOARD SIDE)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Documentation
Issued 23 November 1992 Resolved
PROVIDE COPY OF FCC OPERATOR'S LICENSE TO MSO MIAMI INSPECTION DEPT NLT 23DEC92 BY MAIL/FAX.
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Electrical
Issued 23 November 1992 Resolved
RECHARGE AFT UPPER DECK EMERGENCY LIGHTS & PROVE OPERATION OF SAME._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Lifesaving
Issued 23 November 1992 Resolved
MAKE OPERABLE, WATER LIGHT FOR RING BUOY W/LIFE LINE LOCATED ON PORT SIDE OF WHEELHOUSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Fire Fighting
Issued 23 November 1992 Resolved
INSTALL PROPER MOUNTING BRACKETS FOR ALL FIRE EXTINGUISHERS ONBOARD (6), (GENERAL BRAND BRACKET # BGP-10).
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Electrical
Issued 23 November 1992 Resolved
PROPERLY INSTALL DISTRIBUTION PANEL IN WATER PUMP ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Documentation
Issued 23 November 1992 Resolved
PROVIDE WASTE MANAGEMENT PLAN FOR VESSEL AND KEEP COPY ONBOARD AT ALL TIMES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Engineering
Issued 2 October 1992 Resolved
EFFECT REPAIRS TO THE VESSEL'S BOW THRUSTER IN WAY OF THE UNITS OUTER OIL SEALS, AND BOTH 1 1/2" HYDRAULIC OIL SUPPLY AND RETURN LINES._x001C_ _x001C_ REMOVE HYDRAULIC OIL FROM BILGES.
Condition: Unknown
Due 27 November 1992
Resolved 27 November 1992
Construction/Loadline
Issued 29 January 1992 Resolved
VESSEL TO BE DRYDOCKED FOR USCG D/D EXAMINATION PRIOR TO 09FEB92. AFTER THIS DATE, CERTIFICATE & COPIES WILL BE INVALID. CALL FOR AN APPOINTMENT AT [phone withheld].
Condition: Unknown
Due 9 February 1992
Resolved 6 February 1992
Unknown
Issued 28 October 1989 Resolved
SUBMITTED PLANS WILL BE REVIEWED AND ANY COMMENT LETTERS MUST BE ANSWERED WITHIN 60 DAYS
Condition: Unknown
Due 28 October 1989
Resolved 28 October 1989
Construction/Loadline
Issued 28 October 1989 Resolved
PROVIDE SECONDARY EXIT FROM GALLEY AT NEXT DRYDOCKING
Condition: Unknown
Due 28 October 1989
Resolved 28 October 1989
Unknown
Issued 27 September 1984 Resolved
STENCIL ALL THE VENTS ON THE MAIN DECK AND REPLACE THE MISSING BALL FLOATS.
Condition: Unknown
Due 27 September 1984
Resolved 27 September 1984
Engineering
Issued 27 September 1984 Resolved
REPAIR THE TACHOMETER ON BOTH MAIN ENGINES.
Condition: Unknown
Due 27 September 1984
Resolved 27 September 1984
Construction/Loadline
Issued 27 September 1984 Resolved
PROPERLY REPAIR THE BROKEN WELDS IN THE FOLLWING COMPARTMENTS AS NOTED: A. STEERING COMPARTMENT; B. FOREPEAK; C. ENGINEROOM; D. MAIN DECK.
Condition: Unknown
Due 27 September 1984
Resolved 27 September 1984

Casualty record · 2

10 November 2004Routine · role: Involved in a Marine Casualty · at BROADWAY CAUSEWAY BRIDGE · activity 2241433
21 November 2021Routine · role: Involved in a Marine Casualty · at SUNRISE BRIDGE · activity 7356470
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.