SUN DREAM is a 1978 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in September 2025, along with 13 deficiencies and 2 casualty investigations between 2004 and 2021.
Records from 2004 to 2025. Most recent: inspection, 4 September 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 19 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton 61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 November 2020Resolved
each ring life buoy must be in accordance with 46 CFR 160.050. ring life buoy was cracked and needs replacement.
46 CFR 180.30-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2020
Resolved 20 November 2020
Resolution: received email that condition was rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2020Resolved
Handle broken off circuit breaker switch for the #2 hydraulic pump on main switch board in E/R. Replace circuit breaker.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 January 2020
Resolution: Breaker switch replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 January 2020Resolved
No fire hazards shall exist. Starboard main turbo is loose and leaking oil. Tighten bolts and ensure no oil leaks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2020
Resolution: Marine inspector tested the engine and observed no signs of leakage.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 January 2020Resolved
Fire pump’s minimum capacity shall be 50 gallons per minute at 60 psi. The sea suction for fire pump is clogged obstructing the pump’s flow. Clear clogged sea suction.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2020
Resolution: The sea suction was cleared, pump tested and holds required pressure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2020Resolved
Battery chargers were shorted out by raw water pump leak. Replace battery chargers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 January 2020
Resolution: Representative from the vessel replaced battery charger.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2020Resolved
Exhaust piping must be gas tight. Repair exhaust leak off starboard main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2020
Resolution: Exhaust leaked repaired, no leakage present.
Lifesaving › Lifebuoys › Serviceable
Issued 24 October 2016Resolved
Renew ring buoy on uppermost deck. -46CFR180.70
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Resolution: Replaced ring buoy.
Lifesaving › Lifebuoys › Serviceable
Issued 24 October 2016Resolved
Renew grab line on ring buoy aft second deck. -46CFR180.70
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Resolution: Replaced line on ring buoy aft second deck.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 October 2016Resolved
Renew guard screens on port and stbd ventilation motors.
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Resolution: Replaced screens on port and stbd ventilation motors.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 October 2016Resolved
Clean and inspect stbd side ventilation trunk.
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Resolution: Ventilation motor trunk cleaned.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 October 2016Resolved
Provide cover for outlet in crew room.
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Resolution: Outlet cover provided in crew room.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 October 2016Resolved
Make permanent-type connections on port generator batteries. Alligator clips currently connected. -46CFR183.05-20
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
Resolution: Permanent-type connections replaced alligator clips on port generator batteries.
Fire Fighting › Fire Pumps › Pressure
Issued 24 October 2016Resolved
Provide repair proposal for fire pump (small leak on discharge connection and gauge reading 40 psi). Observed steady stream from hydrant.
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 9 November 2016
10 November 2004Routine · role: Involved in a Marine Casualty · activity 2241433
21 November 2021Routine · role: Involved in a Marine Casualty · activity 7356470
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.