01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 September 2024
No resolution recorded
All other vessels must undergo an inspection for certification as specified in § 176.404 and annual inspection as specified in paragraph (b)(1) of this section.(1) Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel was unable to conduct annual inspection within the 3 month window. Vessel will need to conduct a satisfactory inspection prior to carriage of passengers.
46 CFR 176.500(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2023
Resolved
A vessel must be provided with a bilge pump in accordance with table 182.520(a). Vessels bilge pump in E/R bilge area was not UL rated and not rated for atleast 1500GPH. Vessel shall replace and mount new appropriate bilge pump.
46 CFR 182.520(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 10 July 2023
Resolution: Replaced with 2000 GPH UL Rated Bilge Pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2023
Resolved
A flexible hose may be used for discharge line of submersible electrical pump provided the hose is of good quality and suitable for intended use. Vessels shall replace hose with adequate SAE rated hose.
46 CFR 182.520(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 10 July 2023
Resolution: Bilge pump discharged hose replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 18 May 2023
Resolved
At each inspection, all rigging shall be subject to inspection. Vessel shall make jib sail available for inspection.
46 CFR 176.802
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 10 July 2023
Resolution: Recieved photographs of jib sail onboard and installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2023
Resolved
Portable fire extinguishers installation and locations must be to the satisfaction of the OCMI. 02 fire extinguishers were not properly mounted.
46 CFR 181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 10 July 2023
Resolution: Fire extinguishers properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 May 2023
Resolved
Gauges to indicate RPM, J/W Temp, and L/O pressure must be provided. 01 gauge at helm was not properly installed and unable to be read.
46 CFR 182.410(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 10 July 2023
Resolution: New RPM, J/W Temp, and L/O Pressure guages installed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 18 May 2023
Resolved
Each MSD device must be free of defects that would allow toxic substances to escape to the interior of the vessel. Sewage hose is worn and needs replaced.
33 CFR 159.95(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 10 July 2023
Resolution: New sewaged hose replaced in-kind.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2023
Resolved
Marine employers shall establish programs for the chemical testing of crewmembers. Vessel has no DAPI paperwork on board. Vessel shall provide all required DAPI information.
46 CFR 16.230(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 18 May 2023
Resolution: Verified vessels DAPI paperwork. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2022
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for intended service. The hull structure must be adequately reinforced to ensure sufficient strength. The area house where the mast partners to the superstructure is cracked. Vessel shall repair area during next mast unstepping. Vessel shall get underway with an attending USCG Marine Inspector during COI inspection to evaluate the the potential flexing and severity of the crack. Mast unstepping requirement timeline will be based on findings.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 June 2022
Resolved 25 May 2022
Resolution: Attending CG inspectors got underway with vessel and determined the crack to not be of concern at the moment. Drydock extension granted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2022
Resolved
Marine employers shall establish programs for the chemical testing of crewmembers. Vessel had no DAPI paperwork onboard. Vessels shall provide all information required for DAPI audit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 23 June 2022
Resolution: Owner/operator provide all necessary DAPI paperwork and placed on file on vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 May 2022
Resolved
A fixed gas fire extinguishing system must be approved by commandant and meet requirements of 46 CFR 181.420. Fireboy was newly installed but has not been serviced or inspected IAW NFPA.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 May 2022
Resolution: Vessel had fireboy serviced and provided service report to the attending marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2022
Resolved
Prior to receiving a COI, owners shall submit for approval a rigging plan showing sail area and centers of effort as well as arrangment. dimensions and connections sail plan was not available for inspection.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 24 June 2022
Resolution: Owner provided a sail plan.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 May 2022
Resolved
Owner must have vessel ready for inspection of its fire protective equipment. All portable fire ext. were either not inspected or ooc.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 May 2022
Resolution: Vessel had fire extinguishers serviced and fire service report provided to attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 May 2022
Resolved
Each ring life buoy must be approved IAW 160.050 or other standard approved by commandant. Ring buoy did not have retro-reflective tape or name of vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 23 June 2022
Resolution: Owner provided picture of appropriate/approved life ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2022
Resolved
Submersible bilge pump may be used provided that the pump is permanently mounted. Bilge pump and high level in E/R space was not permanently mounted.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 23 June 2022
Resolution: Owner provided picture of bilge pump and high level alarm permanently mounted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 May 2022
Resolved
Owner must have vessel ready for inspection of its fire protective equipment. Fire boy handle at operating station is broken and needs replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 25 May 2022
Resolution: Vessel replaced handle.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2022
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for intended service. The hull structure must be adequately reinforced to ensure sufficient strength. The area of the deck where the mast partners to the superstructure is cracked. Vessel shall repair area during next mast unstepping. Vessel shall get underway with an attending USCG Marine Inspector during COI inspection to evaluate the potential flexing and severity of the crack. Mast unstepping requirement timeline will be based on findings. 25MAY22 Attending inspector for COI exam determined that unstepping of mast will be required prior to vessel operating in 2023.
46 CFR 177.330
Action required: 705 - Other - as specified
Due 1 June 2023
Resolved 17 May 2023
Resolution: Mast was unstepped and inspected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 July 2019
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall have the following ready for inspection: all spars, standing rigging, running rigging, blocks, fittings, and sail. The headstay was removed from the vessel for replacement. The new headstay was not installed or inspected. The new headstay must be installed to the satisfaction of the Marine Inspector prior to the carriage of passengers.
46 CFR 176.802
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 July 2019
Resolved 28 August 2019
Resolution: Headstay replaced to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2019
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall have the following ready for inspection: all spars, standing rigging, running rigging, blocks, fittings, and sail. Vessel does not have a preventative maintenance plan for installed sail rigging as outlined in NVIC 02-16. Create preventative maintenance plan and inspection log using NVIC 02-16 as guidance. Provide proof of plan to the satisfaction of the Marine Inspector.
46CFR176.802 ; NVIC 02-16
Action required: 705 - Other - as specified
Due 25 August 2019
Resolved 25 May 2022
Resolution: Vessel obtained and follows an adequate PMP.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 July 2019
Resolved
A number of child life jackets equal to at least 10% of the number of persons permitted on board must be provided. Two child life jackets were removed from service. Vessel is restricted to 4 children onboard. Procure 2 child lifejackets and provide proof to the satisfaction of the Marine Inspector.
46CFR180.71(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2019
Resolved 28 August 2019
Resolution: Marine Inspector verified life jackets procured and maintained onboard the vessel.
Sail Rigging › Mast Step › Mast Partners
Issued 12 May 2017
Resolved
Complete third party rigging survey by approved sail rigger. Provide report attesting to rig tune and causes/corrective action for cracked mast partner. Survey to include rig aloft. 46CFR176.840
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 June 2017
Resolution: Received 3rd party rigging survey attesting to rig tune.
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 May 2017
Resolved
Vessel did not have a training log or lifesaving maintenance log on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 8 May 2017
Resolution: Spoke with the master about keeping logs onboard.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 8 May 2017
Resolved
No Garbage Plan onboard vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 15 June 2017
Resolution: Implemented Garbage Plan.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 8 May 2017
Resolved
Fire Extinguisher was stowed beneath sink. There were no markings indicating the location of storage.
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 15 June 2017
Resolution: Location was labeled.
Construction/Loadline › Structures › Machinery Space Opening
Issued 8 May 2017
Resolved
Engine Room Space contained holes and openings into other spaces preventing a vapor barrier.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 15 June 2017
Resolution: Engineroom was sealed.
Fire Fighting › Fire Bucket › Quantity
Issued 8 May 2017
Resolved
Vessel is missing 2 fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 15 June 2017
Resolution: Fire Buckets were provided.
Construction/Loadline › Hull › Hull Plating
Issued 8 May 2017
Resolved
Found opening on through hull penetration on transom. Daylight entering steering space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 15 June 2017
Resolution: Fitting was sealed with 5200 until new fitting could be ordered.