Records from 1989 to 2024. Most recent: operational control imposed, 12 September 2024.
Inspection history · 59
12 September 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8001708
9 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684818
3 May 2022
Internal Structural Exam · Hull Examination · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7446816
5 October 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7070176
31 July 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7037707
11 July 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6745842
5 August 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6501294
12 May 2017
Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6148041
8 May 2017
Administrative Inspection · Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6137587
5 May 2016
Drydock Extension · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5863184
25 November 2015
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5770472
9 September 2015
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5733045
8 September 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5238909
11 June 2014
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4881488
20 October 2010
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3874016
15 May 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3211159
31 May 2007
Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2979875
31 May 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2985739
9 June 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2675162
11 May 2006
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2640844
10 November 2005
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2525647
4 May 2005
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2353464
28 May 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2081057
12 May 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2071711
25 August 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1886745
22 July 2003
Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1846353
16 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1075584
16 August 2001
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1072642
10 July 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1422093
30 October 2000
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1448198
23 May 2000
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1050241
2 May 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1365742
4 September 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 179530
29 June 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1093325
9 June 1999
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1411896
17 November 1998
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1438775
5 June 1997
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 774640
3 September 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 46344
2 July 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355886
2 May 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363625
12 July 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 882631
19 May 1995
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377419
4 May 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 378059
20 April 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357124
6 April 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371065
14 December 1994
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1435565
12 December 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1249
29 August 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 706774
25 August 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 370001
6 August 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1155502
14 July 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1155438
13 May 1993
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1149530
7 April 1993
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1147519
6 November 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1132396
4 September 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 84236
9 April 1992
Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1255863
6 March 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1258310
19 February 1992
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1259152
29 June 1989
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1990055
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 September 2024
No resolution recorded
All other vessels must undergo an inspection for certification as specified in § 176.404 and annual inspection as specified in paragraph (b)(1) of this section.(1) Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel was unable to conduct annual inspection within the 3 month window. Vessel will need to conduct a satisfactory inspection prior to carriage of passengers.
46 CFR 176.500(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2023
Resolved
A vessel must be provided with a bilge pump in accordance with table 182.520(a). Vessels bilge pump in E/R bilge area was not UL rated and not rated for atleast 1500GPH. Vessel shall replace and mount new appropriate bilge pump.
46 CFR 182.520(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 10 July 2023
Resolution: Replaced with 2000 GPH UL Rated Bilge Pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2023
Resolved
A flexible hose may be used for discharge line of submersible electrical pump provided the hose is of good quality and suitable for intended use. Vessels shall replace hose with adequate SAE rated hose.
46 CFR 182.520(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 10 July 2023
Resolution: Bilge pump discharged hose replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 18 May 2023
Resolved
At each inspection, all rigging shall be subject to inspection. Vessel shall make jib sail available for inspection.
46 CFR 176.802
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 10 July 2023
Resolution: Recieved photographs of jib sail onboard and installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2023
Resolved
Portable fire extinguishers installation and locations must be to the satisfaction of the OCMI. 02 fire extinguishers were not properly mounted.
46 CFR 181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 10 July 2023
Resolution: Fire extinguishers properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 May 2023
Resolved
Gauges to indicate RPM, J/W Temp, and L/O pressure must be provided. 01 gauge at helm was not properly installed and unable to be read.
46 CFR 182.410(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 10 July 2023
Resolution: New RPM, J/W Temp, and L/O Pressure guages installed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 18 May 2023
Resolved
Each MSD device must be free of defects that would allow toxic substances to escape to the interior of the vessel. Sewage hose is worn and needs replaced.
33 CFR 159.95(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 10 July 2023
Resolution: New sewaged hose replaced in-kind.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2023
Resolved
Marine employers shall establish programs for the chemical testing of crewmembers. Vessel has no DAPI paperwork on board. Vessel shall provide all required DAPI information.
46 CFR 16.230(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 18 May 2023
Resolution: Verified vessels DAPI paperwork. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2022
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for intended service. The hull structure must be adequately reinforced to ensure sufficient strength. The area house where the mast partners to the superstructure is cracked. Vessel shall repair area during next mast unstepping. Vessel shall get underway with an attending USCG Marine Inspector during COI inspection to evaluate the the potential flexing and severity of the crack. Mast unstepping requirement timeline will be based on findings.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 June 2022
Resolved 25 May 2022
Resolution: Attending CG inspectors got underway with vessel and determined the crack to not be of concern at the moment. Drydock extension granted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2022
Resolved
Marine employers shall establish programs for the chemical testing of crewmembers. Vessel had no DAPI paperwork onboard. Vessels shall provide all information required for DAPI audit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 23 June 2022
Resolution: Owner/operator provide all necessary DAPI paperwork and placed on file on vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 May 2022
Resolved
A fixed gas fire extinguishing system must be approved by commandant and meet requirements of 46 CFR 181.420. Fireboy was newly installed but has not been serviced or inspected IAW NFPA.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 May 2022
Resolution: Vessel had fireboy serviced and provided service report to the attending marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2022
Resolved
Prior to receiving a COI, owners shall submit for approval a rigging plan showing sail area and centers of effort as well as arrangment. dimensions and connections sail plan was not available for inspection.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 24 June 2022
Resolution: Owner provided a sail plan.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 May 2022
Resolved
Owner must have vessel ready for inspection of its fire protective equipment. All portable fire ext. were either not inspected or ooc.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 May 2022
Resolution: Vessel had fire extinguishers serviced and fire service report provided to attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 May 2022
Resolved
Each ring life buoy must be approved IAW 160.050 or other standard approved by commandant. Ring buoy did not have retro-reflective tape or name of vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 23 June 2022
Resolution: Owner provided picture of appropriate/approved life ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2022
Resolved
Submersible bilge pump may be used provided that the pump is permanently mounted. Bilge pump and high level in E/R space was not permanently mounted.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 23 June 2022
Resolution: Owner provided picture of bilge pump and high level alarm permanently mounted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 May 2022
Resolved
Owner must have vessel ready for inspection of its fire protective equipment. Fire boy handle at operating station is broken and needs replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 25 May 2022
Resolution: Vessel replaced handle.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2022
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for intended service. The hull structure must be adequately reinforced to ensure sufficient strength. The area of the deck where the mast partners to the superstructure is cracked. Vessel shall repair area during next mast unstepping. Vessel shall get underway with an attending USCG Marine Inspector during COI inspection to evaluate the potential flexing and severity of the crack. Mast unstepping requirement timeline will be based on findings. 25MAY22 Attending inspector for COI exam determined that unstepping of mast will be required prior to vessel operating in 2023.
46 CFR 177.330
Action required: 705 - Other - as specified
Due 1 June 2023
Resolved 17 May 2023
Resolution: Mast was unstepped and inspected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 July 2019
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall have the following ready for inspection: all spars, standing rigging, running rigging, blocks, fittings, and sail. The headstay was removed from the vessel for replacement. The new headstay was not installed or inspected. The new headstay must be installed to the satisfaction of the Marine Inspector prior to the carriage of passengers.
46 CFR 176.802
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 July 2019
Resolved 28 August 2019
Resolution: Headstay replaced to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2019
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall have the following ready for inspection: all spars, standing rigging, running rigging, blocks, fittings, and sail. Vessel does not have a preventative maintenance plan for installed sail rigging as outlined in NVIC 02-16. Create preventative maintenance plan and inspection log using NVIC 02-16 as guidance. Provide proof of plan to the satisfaction of the Marine Inspector.
46CFR176.802 ; NVIC 02-16
Action required: 705 - Other - as specified
Due 25 August 2019
Resolved 25 May 2022
Resolution: Vessel obtained and follows an adequate PMP.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 July 2019
Resolved
A number of child life jackets equal to at least 10% of the number of persons permitted on board must be provided. Two child life jackets were removed from service. Vessel is restricted to 4 children onboard. Procure 2 child lifejackets and provide proof to the satisfaction of the Marine Inspector.
46CFR180.71(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2019
Resolved 28 August 2019
Resolution: Marine Inspector verified life jackets procured and maintained onboard the vessel.
Sail Rigging › Mast Step › Mast Partners
Issued 12 May 2017
Resolved
Complete third party rigging survey by approved sail rigger. Provide report attesting to rig tune and causes/corrective action for cracked mast partner. Survey to include rig aloft. 46CFR176.840
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 June 2017
Resolution: Received 3rd party rigging survey attesting to rig tune.
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 May 2017
Resolved
Vessel did not have a training log or lifesaving maintenance log on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 8 May 2017
Resolution: Spoke with the master about keeping logs onboard.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 8 May 2017
Resolved
No Garbage Plan onboard vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 15 June 2017
Resolution: Implemented Garbage Plan.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 8 May 2017
Resolved
Fire Extinguisher was stowed beneath sink. There were no markings indicating the location of storage.
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 15 June 2017
Resolution: Location was labeled.
Construction/Loadline › Structures › Machinery Space Opening
Issued 8 May 2017
Resolved
Engine Room Space contained holes and openings into other spaces preventing a vapor barrier.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 15 June 2017
Resolution: Engineroom was sealed.
Fire Fighting › Fire Bucket › Quantity
Issued 8 May 2017
Resolved
Vessel is missing 2 fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 15 June 2017
Resolution: Fire Buckets were provided.
Construction/Loadline › Hull › Hull Plating
Issued 8 May 2017
Resolved
Found opening on through hull penetration on transom. Daylight entering steering space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 15 June 2017
Resolution: Fitting was sealed with 5200 until new fitting could be ordered.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 November 2015
Resolved
Make vessel available for dry-dock exam. Vessel may not carry passengers for hire until required exam has been completed. 46CFR176.600(c)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2015
Resolved 4 May 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 9 September 2015
Resolved
Provide properly serviced A-II extinguisher. Spare unit from dock currently onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 4 May 2016
Sail Rigging › Spars › Boom and Gooseneck Fitting
Issued 9 September 2015
Resolved
Provide repair proposal for identified fracture on the boom connection to the gooseneck fitting.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 4 May 2016
Resolution: repairs complete
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 9 September 2015
Resolved
Provide bonding wire for the flexible section of fuel fill hose.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 4 May 2016
Operations/Management › Drills/Instruction › Safety Orientation
Issued 9 September 2015
Resolved
Provide emergency instructions tailored to the vessels equipment and layout.
Condition: Improper Installation
Due 9 October 2015
Resolved 4 May 2016
Construction/Loadline › Structures › Superstructure
Issued 9 September 2015
Resolved
Provide repair proposal for the identified cabin top fractures adjacent to the mast.
Condition: Invalid
Due 30 November 2015
Resolved 4 May 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 September 2015
Resolved
Provide indication of the space alarming for the bilge high water alarm panel.
Due 30 November 2015
Resolved 4 May 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 October 2010
Resolved
Vessel must complete a dry dock exam prior to the start of operations for the 2011 season.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2011
Documentation › Logs/Records › Drug Test Records
Issued 31 May 2007
Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25.
Due 5 July 2007
Resolved 31 May 2007
Resolution: Training conducted. Company will complete in future.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 11 May 2006
Resolved
Properly service all portable (3 ea) and installed fixed Halon firefighting extinguishers prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Due 11 June 2006
Resolved 9 June 2006
Stability › Watertight Integrity › General
Issued 4 May 2005
Resolved
Properly cap open sea valve in way of old sewage discharge valve aft of engine compartment.
Action required: 705 - Other - as specified
Resolved 4 May 2005
Stability › Watertight Integrity › General
Issued 4 May 2005
Resolved
Properly cap off open sea valve in way of aft accommodation space port side.
Action required: 705 - Other - as specified
Resolved 4 May 2005
Lifesaving › Lifebuoys
Issued 12 May 2004
Resolved
Renew or repair wasted straps securing grab-hold lines to life ring. LEGACY COMPONENT DESC: Life Ring Straps
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Lifesaving › Lifebuoys
Issued 12 May 2004
Resolved
Provide 3'-6' lanyard for water light per 46 CFR 180.70. LEGACY COMPONENT DESC: Water Light
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Lifesaving › Lifebuoys
Issued 12 May 2004
Resolved
Provide quick release mechanism for life ring water light. LEGACY COMPONENT DESC: Water Light
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Lifesaving › Lifebuoys
Issued 12 May 2004
Resolved
Renew life ring water light battery. LEGACY COMPONENT DESC: Water Light
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 May 2004
Resolved
Remove non-essential expired portable fire extinguishers. LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 12 May 2004
Resolution: Removed non-essential expired portable fire extinguisher.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 12 May 2004
Resolved
Renew fixed fire fighting emergency pull knob and provide proof that it works (i.e. Servicing Certificates). LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 24 May 2004
Stability › Unintentional Flooding
Issued 12 May 2004
Resolved
Renew burnt out light for helm high water level bilge alarm. Audible alarm works satisfactorily. LEGACY COMPONENT DESC: Visual Alarm for High Water Bilge Alarm.
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 24 May 2004
Stability › Unintentional Flooding
Issued 12 May 2004
Resolved
Install visual alarm at helm for all high water level bilge alarms. LEGACY COMPONENT DESC: Visual High Water Bilge Alarms
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 24 May 2004
Fire Fighting › Combustible Materials
Issued 12 May 2004
Resolved
Install 30-mesh flame screens for both exterior sewage tank vent and battery box vent. LEGACY COMPONENT DESC: Exterior Sewage Tank and Battery Box Vents
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 24 May 2004
Electrical › Electrical Distribution System (service)
Issued 12 May 2004
Resolved
Properly mount bus block duct taped to mast base located in crew cabin. LEGACY COMPONENT DESC: Distribution Panel Bus
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Electrical › Electrical Distribution System (service)
Issued 12 May 2004
Resolved
Install cover for bus block ducted taped to mast base in crew cabin. LEGACY COMPONENT DESC: Distribution Panel Bus
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Electrical › Electrical Distribution System (service)
Issued 12 May 2004
Resolved
Remove or repair all dead-end wires located in crew cabin head and forward crew cabin. LEGACY COMPONENT DESC: Wiring
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2004
Resolved 24 May 2004
Accommodation/Occupational Safety › Cooking Systems
Issued 12 May 2004
Resolved
Mount or remove gas regulator dangling in starboard closet in aft crew compartment below helm. Regulator was not hooked up to gas. LEGACY COMPONENT DESC: Gas Regulator
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 24 May 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 May 2004
Resolved
Re-connect and install aft engine air intake vent that runs to aft of helm compartment per 46 CFR 182.20-45 and per vessel's original design. If the fixed fire fighting suppression agent was deployed, it would have expelled through vent opening in crew compartment below helm. LEGACY COMPONENT DESC: Ventilation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 May 2004
Resolved
Label fore and aft exterior engine vents. LEGACY COMPONENT DESC: Ventilation
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 24 May 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 May 2004
Resolved
Remove both fore and aft exterior engine vent covers when engine is operated. LEGACY COMPONENT DESC: Ventilation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Stability › Unintentional Flooding
Issued 12 May 2004
Resolved
Correct raw water leaks for engine hoses and fittings. LEGACY COMPONENT DESC: Engine Raw Water Hoses and Fittings
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Fire Fighting › Combustible Materials
Issued 12 May 2004
Resolved
Repair vent to battery box located in crew cabin. LEGACY COMPONENT DESC: Battery Box
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 24 May 2004
Fire Fighting › Combustible Materials
Issued 12 May 2004
Resolved
Make battery box fume tight. Battery box was located under a seat cushion in the forward interior crew cabin which had a broken off vent hose fitting on the outboard side of box. LEGACY COMPONENT DESC: Battery Box
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 24 May 2004
Documentation › Logs/Records
Issued 12 May 2004
Resolved
Provide proof of Senior Deck Hand designation. LEGACY COMPONENT DESC: Senior Deck Hand
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Personnel › Training
Issued 12 May 2004
Resolved
Provide proof of non-expired CPR and First Aid certification for 50% of crew. LEGACY COMPONENT DESC: First Aid/CPR
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 24 May 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 July 2003
Resolved
Provide updated First Aid kit for vessel.
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 22 August 2003
Engineering › Bilge Water Management System
Issued 22 July 2003
Resolved
Submit plans for approval to install bilge alarm in lazarette. Upon approval you will have thirty days to complete this requirement.
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 22 August 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 July 2003
Resolved
Replace Main Diesel Engine raw water suction hose from thru-hull valve to raw water pump. Install raw water pump as per SAE- J1527, A1 or A2 standards.
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 22 August 2003
Electrical
Issued 22 July 2003
Resolved
Provide proper bonding for diesel fuel tank in way of fuel fill connection to fuel tank.
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 22 August 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 July 2003
Resolved
Repair leak in way of MDE heat exchanger.
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 11 August 2003
Resolution: see case file fax
Engineering
Issued 10 July 2001
Resolved
REPLACE OLD FUEL TANK VENT FLAME SCREENS IAW TITLE 46 CFR 182.450(e).
Condition: Unknown
Due 10 July 2001
Resolved 10 July 2001
Documentation
Issued 10 July 2001
Resolved
PROVIDE PROOF OF VALID DOCUMENTATION.
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Fire Fighting
Issued 2 May 2000
Resolved
PROVIDE TYPE B-II PORTABLE FIRE EXTINGUISHER TO BE LOCATED OUTSIDE THE VESSELS ENGINE ROOM, I.A.W. 46 CFR 181.500(a). ITEM TO BE COMPLETED PRIOR TO TAKING PASSENGERS FOR HIRE.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Construction/Loadline
Issued 2 May 2000
Resolved
RELOCATE AUDIBLE/VISUAL HIGH LEVEL BILGE ALARM TO OPERATORS STATION I.A.W. 46 CFR 182.530(a).
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Navigation
Issued 2 May 2000
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD I.A.W. 46 CFR 184.506.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Fire Fighting
Issued 2 May 2000
Resolved
PROVIDE SERVICE REPORT FOR ENGINR ROOM FIXED FIRE FIGHTING SYSTEM I.A.W. 46CFR 176.810(a). ITEM TO BE COMPLETED PRIOR TO TAKING PASSENGERS FOR HIRE.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Fire Fighting
Issued 2 May 2000
Resolved
PROVE PROPER OPERATION OF ENGINE ROOM FIXED FIRE FIGHTING SYSTEM MAIN DIESEL ENGINE SHUTDOWN I.A.W. 46 CFR 181.410(a)(10). ITEM TO BE COMPLETED PRIOR TO TAKING PASSENGERS FOR HIRE.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Navigation
Issued 29 June 1999
Resolved
Provide compass deviation card for magnetic compass.
Condition: Unknown
Due 15 September 1999
Resolved 16 September 1999
Lifesaving
Issued 9 June 1999
Resolved
Replace all distress signal, all are expired.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Lifesaving
Issued 9 June 1999
Resolved
replace lifering_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Construction/Loadline
Issued 9 June 1999
Resolved
Provide bilge alarms at the operator station.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Accommodation/Occupational Safety
Issued 9 June 1999
Resolved
Replace hoses leading to through holes in both heads.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Construction/Loadline
Issued 9 June 1999
Resolved
Re-attach sea valve under step leading to FWD. Seal all sea valves, some are leaking._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Accommodation/Occupational Safety
Issued 9 June 1999
Resolved
Mount COI/stab letter/lifesaving instructions/safety proceedures._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Fire Fighting
Issued 9 June 1999
Resolved
Provide proper gasket material around the engine compartment.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Lifesaving
Issued 9 June 1999
Resolved
Provide proper primary lifesaving.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Engineering
Issued 9 June 1999
Resolved
The emergency fuel shut off valve cable is inoperable. Replace cable._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Navigation
Issued 9 June 1999
Resolved
Provide a compass deviation card for magnetic compass._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Documentation
Issued 9 June 1999
Resolved
Provide FCC station/operators license._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Accommodation/Occupational Safety
Issued 9 June 1999
Resolved
Lifeline rail support on the #5 stdb side is broken free.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Accommodation/Occupational Safety
Issued 9 June 1999
Resolved
Remove lng/cng stove and pressure vessel from vessel._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Lifesaving
Issued 2 May 1996
Resolved
Conduct and log crew training as required by 46 CFR 185.420
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 2 May 1996
Resolved
Repair or replace both buoyant apparatus.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 2 May 1996
Resolved
Conduct and log monthly maintenance performed on both buoyant apparatus as required by 46 CFR 185.722
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Electrical
Issued 2 May 1996
Resolved
Provide and mount 2 portable flashlights as required by 46 CFR 183.340.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 2 May 1996
Resolved
Conduct and log annual maintenance performed on both buoyant apparatus as required by 46 CFR 185.726
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 2 May 1996
Resolved
Conduct and log weekly maintenance performed on both buoyant apparatus as required by 46 CFR 185.720
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Engineering
Issued 2 May 1996
Resolved
Properly label the remote fuel shut off valve as required by 46 CFR 185.608
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 2 May 1996
Resolved
Install retro-reflective tape on the ring buoy as required by 46 CFR 185.604(i)
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Fire Fighting
Issued 2 May 1996
Resolved
Conduct and log fire fighting drills as required by 46 CFR 185.524
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 2 May 1996
Resolved
Provide and post PFD placards as required by 46 CFR 185.516
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 2 May 1996
Resolved
Conduct and log abandon ship, and man overboard drills as required by 46 CFR 185.520
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Documentation
Issued 2 May 1996
Resolved
Post an emergency broadcast placard as required by 46 CFR 184.506
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Fire Fighting
Issued 20 April 1995
Resolved
Provide and prove operation of the FE-241 engine shutdown and manual pull cable in the presence of a CG marine inspector.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Fire Fighting
Issued 20 April 1995
Resolved
Provide CG approved (46CFR161.002) heat detection system for the engine room and prove proper operation in the presence of a CG marine inspector.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Fire Fighting
Issued 20 April 1995
Resolved
Install UL approved smoke detectors in all below deck accommodation spaces,total of 5 required.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Engineering
Issued 20 April 1995
Resolved
Provide a separation between the diesel fuel tank and the accommodation area in accordance with 46 CFR 182.35 or install a UL approved diesel fuel flammable vapor detector and alarm. Passengers are not allowed in any below deck accommodation area until this requirement is met.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Engineering
Issued 20 April 1995
Resolved
Provide Coast Guard approved (46CFR164.009) noncombustible insulation on all engine room boundaries.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Fire Fighting
Issued 20 April 1995
Resolved
Provide a total of 2 B-II fire extinguishers with their mounting brackets.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Lifesaving
Issued 20 April 1995
Resolved
Properly ventilate the storage battery space in accordance with 46 CFR 183.05-20.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Construction/Loadline
Issued 20 April 1995
Resolved
Submit for approval plans for bilge system.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Engineering
Issued 20 April 1995
Resolved
Provide a watertight or vapor tight separation/bulkhead between the engine space and the accommodation space in accordance with 46 CFR 182.35-1.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Construction/Loadline
Issued 20 April 1995
Resolved
Install bilge system in accordance with approved plans.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Engineering
Issued 20 April 1995
Resolved
Provide shut off valve at the tank, operable from outside the tank compartment, from an accessible position on the weather deck in accordance with 46 CFR 182.20-40 (b)(3).
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Accommodation/Occupational Safety
Issued 25 August 1994
Resolved
ON 25AUG94, [name withheld], THE MASTER OF THE M/V FIRST CLASS, A MANNED OCEANGOING SHIP, MORE THAN 40FT IN LENGTH, ENGAGED IN COMMERCE, AND DOCUMENTED UNDER THE LAWS OF THE UNITED STATES, WAS NOT MAINTAINING ON THE SHIP, A WRITTEN RECORD OF ANY GARBAGE DISCHARGE OR DISPOSAL OPERATIONS.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Accommodation/Occupational Safety
Issued 25 August 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Documentation
Issued 7 April 1993
Resolved
PROVIDE [name withheld] OF VALID MARINE DOCUMENT.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Fire Fighting
Issued 7 April 1993
Resolved
SERVICE HALON SYSTEM IN ENGINE COMPARTMENT.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Documentation
Issued 7 April 1993
Resolved
PROVIDE DOCUMENTATION OF COMPLIANCE WITH RANDOM DRUG TESTING REGULATIONS.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Accommodation/Occupational Safety
Issued 9 April 1992
Resolved
PROVIDE ADEQUATE VENTILATION TO MACHINERY AND FUEL TANK SPACE IN ACCORDANCEWITH 46CFR182.20-45.
Condition: Unknown
Due 9 April 1992
Resolved 9 April 1992
Electrical
Issued 9 April 1992
Resolved
INSTALL AUTOMATICALLY ACTUATED EMERGENCY LIGHTING IN THE PASSENGER LOUNGE AREA BELOW THE MAIN DECK IN ACCORDANCE WITH 46CFR184.30-5.
Condition: Unknown
Due 16 November 1992
Resolved 16 November 1992
Fire Fighting
Issued 9 April 1992
Resolved
PROVIDE AUTOMATIC ENGINE SHUTDOWN, AND PROVE OPERATION OF THE FIXED HALON FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 16 November 1992
Resolved 16 November 1992