STRIKE ZONE

STRIKE ZONE is a 1983 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in May 2026, along with 27 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 6 May 2026.

Built
1983
Last inspected
6 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 May 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ2487
228909
Flag
UNITED STATES
Maury page id
psix-228909

Documentation record

Registered dimensions (L × B × D)43.0 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 27 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1983
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMAALAEA, HI
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 24 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 23

6 May 2026 Deficiency Check · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8367738
30 October 2025 Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8261093
22 October 2024 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8021294
8 May 2024 Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7908854
19 October 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7810900
26 September 2023 Deficiency Check · Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7799013
10 January 2023 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7619433
8 November 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7591475
21 October 2021 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7336759
22 June 2021 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7232291
4 November 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7087486
22 June 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6987094
14 May 2020 Drydock Extension
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6953513
6 February 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6906384
23 January 2020 Type not recorded
No type recorded · USCGC OLIVER BERRY (WPC 1124) · USCG Oceania District (CGD-O) · Activity 6895775
5 December 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6868362
15 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6581753
7 May 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6417963
23 January 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6343314
11 November 2016 DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6030399
4 October 2016 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 6235873
22 September 2016 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6018026
14 January 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5802087

Deficiency record · 27

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Steering ram hydraulic hose lines and fittings worn and wasted. Provide new hose and fittings. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2025
Resolved 10 November 2025
Resolution: Vessel owner installed new ram and hydraulic lines/fittings
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 October 2023 Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The inspection may include an inspection of the following items: Certificates and operating manuals, including certificates issued by the FCC. FCC Safety Radio Certificate not issued by FCC licensed technician for radio installation. Provide inspection and valid FCC Safety Radio Certificate. 46 CFR 176.402
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2023
Resolved 4 December 2023
Resolution: New FCC Safety Radio Certificate provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 October 2023 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicator at helm not operational. Provide visual indicator for bilge pump. 46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2023
Resolved 12 January 2024
Resolution: Indicator provided for bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2023 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Flexible hose/fitting on steering gear leaking hydraulic oil into laz. Remove oil from bilge and secure leak. 46 CFR 182.01-5 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 January 2023
Resolution: Loose fitting tightened. Oil in bilge removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2023 Resolved
A propulsion engine control system must be designed so that a loss of power to the control system does not result in an increase in shaft speed. Electronic propulsion controller installed on vessel. QFA and DVTP not provided and test not completed. Provide QFA and DVTP in accordance with CVC-Policy Letter 17-07 and conduct testing IAW approved QFA and DVTP. 46 CFR 184.620
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2023
Resolved 16 February 2023
Resolution: QFA/DVTP approved by MSC.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2023 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Vessels remote fuel shutoff station not labeled. Provide marking. 46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2023
Resolved 6 April 2023
Resolution: Fuel shutoff marking provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2023 Resolved
In systems where flexible hoses are permitted to be clamped, double hose clamping is required. Missing double hose clamps on port side exhaust. Provide hose clamps. 46 CFR 182.410 (d) (1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2023
Resolved 7 April 2023
Resolution: Double hose clamps provided.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 January 2023 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Starboard side engine missing guard forward. Provide guard for rotating machinery. 46 CFR 177.960
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2023
Resolved 6 April 2023
Resolution: Cover for rotating machinery provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2023 Resolved
For the purpose of flexibility only, flexible hose installed in lengths of not more than 30 inches may meet the following requirements: USCG Type A1 flexible hose may be accepted in accordance with 33 CFR part 183, subpart J. Fuel hose installed at engine repower not proved to meet USCG approval. Provide documentation showing hose meets USCG approval. 46 CFR 182.720(e)(3)(v)(1)(C)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2023
Resolved 6 April 2023
Resolution: New fuel line installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 January 2023 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel does not have interconnected fire detection system. Provide approved interconnected fire detection system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2023
Resolved 6 April 2023
Resolution: Interconnected fire detection installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2023 Resolved
The vessel may undergo a simplified stability proof test in the presence of a Coast Guard marine inspector. STIKE ZONE conducted an engine repower. Weight change was over 185lbs. A new simplified stability test must be conducted. Conduct a simplified stability test. 46 CFR 178.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2023
Resolved 26 September 2023
Resolution: Simplified Stability Test conducted. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 November 2022 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Electrical bilge pump light in laz and engine room not operational. Provide operational indicator lights. 46 CFR 182.530(C)
Action required: 10 - Deficiency Rectified
Resolved 8 November 2022
Resolution: New lights provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 November 2022 Resolved
A pre-engineered fixed gas fire extinguishing system must be capable of manual activation from outside the space. Pull cable beginning to fray and lose strands. Provide new pull cable. 46 CFR 181.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 7 December 2022
Resolution: New pull cable installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 November 2022 Resolved
The master and crew will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard. Emergency instructions not on vessel. Provide emergency instructions that meet 46 CFR 185.512. 46 CFR 185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 7 December 2022
Resolution: Emergency instructions posted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 October 2021 Resolved
Sternlight means a white light placed as nearly as practicable at the stern showing an unbroken light over an arc of the horizon of 135 degrees. Stern navigation light partially obstructed by fishing rod holders. Provide unbroken light over 135 degree arc. Nav Rules - Rule 21
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2021
Resolved 24 November 2021
Resolution: Sternlight raised.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2021 Resolved
Each life jacket must be marked with Type 1 retroflective material. Retro material on numerous life jackets is worn and does not provide the reflective properties. Provide new retroreflective material on those life jackets. 46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2021
Resolved 24 November 2021
Resolution: Retro Tape provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 October 2021 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Indicators for automatic bilge pumps where not installed. 46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2021
Resolved 21 December 2021
Resolution: New indicator provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2021 Resolved
Random drug test results for 2021 not recorded. Provide random test results of crew that was tested during 2021. 46 CFR 16.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2021
Resolved 30 October 2021
Resolution: Drug test results provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 November 2020 Resolved
Electrical equipment on a vessel must be maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment. Dead end and exposed wires found under operating station at helm. Remove dead end wires and cap exposed wires under operating station at helm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 16 November 2020
Resolution: Wires removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2020 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level alarm. Visual and audible alarms were not working properly for the engine room and head spaces. Repair visual and audible high water alarms for engine room and head space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2020
Resolution: New panel installed. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 November 2020 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life float line worn and wasted due to sun exposure. Replace life line around life float to make like new.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2020
Resolution: New line installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2020 Resolved
Equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Rubber hose between suction and piping for bilge was deteriorated and sucking air. Replace rubber hose between suction and piping for bilge throughout vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 16 November 2020
Resolution: New hose installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 November 2020 Resolved
Electrical equipment exposed to corrosive environments must be suitable construction and corrosion resistant. Port inverter battery was found to be leaking battery acid. Ensure battery is not leaking acid and/or replace if battery is found defective.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 16 November 2020
Resolution: Battery cleaned. Random bolt in box causing corrosion.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2020 Resolved
Remote fuel shutoff stations must be marked in clearly legible at least 1 inch high indicating purpose of the valve and direction of operation. Emergency fuel shutoff valves not labeled on vessel. Ensure proper labeling of emergency fuel shutoff valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 16 November 2020
Resolution: Shutoffs marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2020 Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturers instructions. Fireboy bottle was not properly secured to vessel with bracket. Ensure proper installation of Fireboy bottle in accordance with manufacturers instructions. Provide Manufactures instructions to verify agent release mechanism is as designed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 16 November 2020
Resolution: Proper braket installed. Instructions provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2020 Resolved
Gauges to indicate lubricating oil pressure must be provided for all propulsion engines installed on the vessel. Port side engine lube oil pressure gauge not working at vessel operating station. Ensure proper operation of port engine lube oil pressure gauge at vessel operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 23 November 2020
Resolution: New oil pressure gauge installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 4 November 2020 Resolved
Rails on passenger decks of a vessel engaged in excursion trips must be at least 39.5 inches high. Vessels stern rail was found missing and not meeting 39.5 inch height requirement. Ensure proper installation of aft stern rail to meet 39.5 inch requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 16 November 2020
Resolution: Line installed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.