Records from 1992 to 2023. Most recent: inspection, 30 January 2023.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 May 2021
Resolved
A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Upon administrative review, vessel found to be overdue for drydock and internal exams. Vessel shall undergo drydock and internal structural exams prior to the carriage of passengers.
46CFR176.600(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2021
Resolution: Exam completed. Deficiency rectified.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 May 2021
No resolution recorded
Vessels must undergo an annual inspection within the 3 months before or after each anniversary date. Upon administrative review, vessel found to be overdue for two annual inspections. Vessel shall undergo a COI inspection prior to the carriage of passengers.
46CFR176.500(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry-dock examination and an internal structural at least once every two years.
Vessel has exceed dry-dock and internal structural examination dates.
IAW: 46 CFR 176.600 (c) (1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2019
Resolution: Vessel completed credit dry-dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 October 2018
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Engine coolant levels indicate engine cooling system is leaking. Prove proper operation of engine cooling system and provide technicians report regarding coolant leaks. - 46CFR182.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2018
Resolution: Owner provided technician's report from Inter-Bay Moorings (IBM) Marina and Shipyard. MIs contacted shipyard to ensure testing was done. IBM confirmed cooling system was pressure tested with no leaks discovered.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 October 2018
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended.
Bilge discharge valve has flex hose between the hull and the valve. Remove flex hose from forward bilge discharge overboard between hull and valve. - 46CFR182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2018
Resolved 15 November 2018
Resolution: Owner installed ferrous metal valve in way of hull, to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 October 2018
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station.
Vessel does not have any guages for engine. Install guages. - 46CFR182.410(b)
Action required: 15 - Rectify deficiencies by next port
Due 7 November 2018
Resolved 15 November 2018
Resolution: Owner installed guages for jacket water temp and oil pressure. Tested, all sat. RPM guague was previously installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2018
Resolved
All cable and wire must be protected from the weather.
Latch on wire and cable access under operating station is inoperable. Repair or replace. - 46CFR183.340(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2018
Resolved 13 November 2018
Resolution: Owner proved operation of latch.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 October 2018
Resolved
Any vessel of at least five net tons which engages in coastwise trade, on the navigable waters of the United States or in the Exclusive Economic Zone, must have a Certificate of Documentation (COD) bearing a valid endorsement.
Owner did not have valid COD on board at time of inspection. Make COD available for inspection. - 46CFR67.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2018
Resolution: Owner provided COD.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 October 2018
Resolved
A pre-engineered fixed gas fire extinguishing
system must be installed in accordance with
the manufacturer’s instructions.
"Charge" indicator light for fireboy system does not work. Repair or replace. - 46CFR181.420(a)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2018
Resolution: Replaced indicator light. Test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2018
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is
operating.
Indicating light is not operable. Repair or replace. - 46CFR182.530(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2018
Resolution: Replaced indicator light. Test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2018
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended.
Plastic coupling installed on engine cooling hose. Remove plastic coupling in exhaust line and replace with suitable marine grade hose. - 46CFR182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2018
Resolved 24 October 2018
Resolution: Replaced entire length with suitable marine grade hose.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 October 2018
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with
the roll and pitch of the vessel, and free from exposure to water splash or spray.
Battery covers are missing. Install per-existing battery covers. - 46CFR183.350(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2018
Resolved 24 October 2018
Resolution: Installed pre-existing battery covers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 October 2018
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
Wires connected to battery terminals are exposed near connections. Repair. - 46CFR183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2018
Resolved 24 October 2018
Resolution: Installed terminal covers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2018
Resolved
such as Indian Orange, International Orange, or Scarlet
Munsell Red.
Five adult life jackets are dirty reducing their visibility. Clean. - 46CFR180.71(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2018
Resolved 24 October 2018
Resolution: Operator cleaned life jackets to the satisfaction of the attending Marine Inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 29 September 2017
Resolved
Provide 01 type BI portable fire extinguisher. 46CFR185.500
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2017
Resolution: Provided missing fire extinguisher
Lifesaving › Buoyant Apparatus › Marking
Issued 29 September 2017
Resolved
Provide/renew solas retroreflective tape on ring buoy. 46CFR185.604
Condition: Improper/Lack of Maintenance
Due 6 October 2017
Resolved 2 October 2017
Resolution: Replaced retro-reflective tape.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 29 September 2017
Resolved
Provide emergency Instructions. 46CFR185.510
Condition: Improper/Lack of Maintenance
Due 6 October 2017
Resolved 2 October 2017
Resolution: Provided emergency instructions
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 20 September 2017
Resolved
Missing 2 red flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2017
Resolved 29 September 2017
Resolution: Replaced missing flares
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 September 2017
Resolved
Missing; US Coast Pilot,Tide/Tidal Current Tables,Coast Guard Light List
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2017
Resolved 29 September 2017
Resolution: Provided missing coast pilot, tide and current tables and light list
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 September 2017
Resolved
Both portable fire extinguishers service expired Jul 2016, provide prove of service.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2017
Resolved 2 October 2017
Resolution: Provided portable fire extinguisher service report
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 20 September 2017
Resolved
Found fixed fire system expired, provide prove of service.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2017
Resolved 2 October 2017
Resolution: Provided fixed fire extinguisher service report.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 September 2017
Resolved
Found Lifebuoy missing letters, mark lifebuoy properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2017
Resolved 29 September 2017
Resolution: Properly stenciled ringbuoy
Operations/Management › Drills/Instruction › Abandon Ship
Issued 20 September 2017
Resolved
Drills and training log missing, provide prove of drills and training logs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 2 October 2017
Resolution: Provided drill logs
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 September 2017
Resolved
Found stern light inoperable, provide prove of operable stern light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 29 September 2017
Resolution: Stern light is fully operational
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 September 2017
Resolved
Overdue on annual inspection. Must complete prior to operating with passengers.
46 CFR 176.500(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2017
Resolved 2 October 2017
Resolution: Conducted satisfactory COI inspection
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 May 2017
Resolved
Vessel missed hull & internal structural exams. 46CFR176.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2017
Resolution: Completed credited DD/ISE.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 5 August 2016
Resolved
Ensure securing of B-II fire extinguisher as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 12 August 2016
Resolution: Corrected to the satisfaction of the Marine Inspector.
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 August 2016
Resolved
Fuel shutoff valves must be marked clearly in one inch high letters. 46 CFR 181.608
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 12 August 2016
Resolution: Corrected to the satisfaction of the Marine Inspector.
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 August 2016
Resolved
Ensure Coast Pilot is present onboard as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 17 August 2016
Resolution: Corrected to the satisfaction of the Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 August 2015
Resolved
Engine has exposed belts and pullys, install a guard on the forward end of the engine. 46CFR177.960
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 5 August 2016
Resolution: Owner repplace engine guard.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 August 2015
Resolved
Visual bildge high level alarm inoperable. 46CFR182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2015
Resolution: Owner replaced visual indicator on bildge high level alarm.
Lifesaving › Hand Flares › Not on Board
Issued 13 August 2015
Resolved
Vessel missing flares must provide 2 more red flares for a total of 6 or 3 orange smoke flares. 46CFR180.68
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2015
Resolution: Owner provided three new red flares.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 13 August 2015
Resolved
Condemeded 6 PFDS. Vessel passanger count reduced to 31 until owner provides new PFDs. 46CFR180.71
Action required: 705 - Other - as specified
Resolved 5 August 2016
Resolution: Owner replace PFDs.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 March 2006
Resolved
Provide bracket and lanyard for ring life buoy floating waterlight as required by 46 CFR 180.70 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 6 May 2013
Resolution: Waterlight mounted on bracket as required.
Documentation › Markings/Placards › Lifejacket Placard
Issued 14 March 2006
Resolved
Post lifejacket donning placard in a conspicuous place that is regularly accessible and visible to the crew and passengers as required by 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 6 May 2013
Resolution: Posted lifejacket donning placard in a visible location.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 March 2006
Resolved
Both portable fire extinguishers must be relocated so that they are clearly visible, readily accessible, and free from obstruction during removal from bracket as required by 46 CFR 181.520 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 24 May 2013
Resolution: Fire extinguishers are readily accessible and properly serviced.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 August 2005
Resolved
Provide valid Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2006
Resolved 4 January 2006
Personnel › Training › First Aid/CPR
Issued 11 August 2005
Resolved
Provide Red Cross first aid/CPR cards for 50% of crew as required by NVIC 1-91.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Resolution: Cards provided
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 August 2005
Resolved
Provide proof of crew enrollment in Annual drug and alcohol program as required
by 46 CFR Part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Resolution: Information provided
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 11 August 2005
Resolved
Provide fixed fire extinguisher servicing certificates as required by 46 CFR 176.810(b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Personnel › Certificates/Documents/Licenses › License, Master
Issued 11 August 2005
Resolved
Provide Operator's license as required by 46 CFR 15.805 and 46 CFR 185.402
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Resolution: Operators license provided
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 August 2005
Resolved
Provide Current training logbook as required by 46 CFR 185.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 August 2005
Resolved
Provide Lifesaving equipment maintenance record book as required by 46 CFR 185.702
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Documentation › Logs/Records › Logbook (official)
Issued 11 August 2005
Resolved
Provide Bridge log book as required by 46 CFR 185.702, 46 CFR 185.520, 46 CFR 185.524
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Operations/Management › Passenger Operations › Safety Orientation
Issued 11 August 2005
Resolved
Provide method for submitting passenger count as required by 46 CFR 185.504
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 August 2005
Resolved
Provide current Navigation publications as required by 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Resolution: Nav pubs provided
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 August 2005
Resolved
Demonstrate proper operation of Navigation lights as required by 46 CFR 183.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Documentation › Certificates/Documents › Stability Letter
Issued 11 August 2005
Resolved
Provide stability letter and have posted or readily available onboard vessel. 46CFR176.306
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Resolution: Stability letter onboard vessel
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 August 2005
Resolved
Demonstrate proper operation of illuminated Magnetic compass as required by
46 CFR 184.402
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Communications › Audible Communications › Horn/Whistle
Issued 11 August 2005
Resolved
Provide Signaling devices (sound) (proper whistle/horn and bell) as required by 33 CFR Part 86
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Lifesaving › Hand Flares › Storage
Issued 11 August 2005
Resolved
Mark watertight flare container "Distress Signals" as required by 46 CFR 185.614
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 11 August 2005
Resolved
Demonstrate control of propulsion engine systems from operating station
as required by 46 CFR 184.620
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Construction/Loadline › Hull › Stringer
Issued 11 August 2005
Resolved
Make vessel ready for internal inspection of hull structure outlined in 46 CFR 176.802
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Operations/Management › Passenger Operations › Safety Orientation
Issued 11 August 2005
Resolved
Provide method for Passenger Safety Orientation as required by 46 CFR 185.506
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Operations/Management › Passenger Operations › Safety Orientation
Issued 11 August 2005
Resolved
Provide method for submission of Crew and passenger list as required by 46 CFR 185.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 11 August 2005
Resolved
Provide proper length anchor line as required by 46 CFR 184.300
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 11 August 2005
Resolved
Replace retro reflective tape on life jackets where deteriorated as required by
46 CFR 180.78
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 August 2005
Resolved
Replace expired eyewash in First aid kit 46 CFR 184.710, 46 CFR 160.041
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 August 2005
Resolved
Prove proper operation of required shutdowns, audible alarm and light at discharge station upon simulated actuation of fixed firefighting system as required by 46 CFR 182.465(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Resolution: Fixed firefighting operational
Fire Fighting › Fire Bucket › Availability
Issued 11 August 2005
Resolved
Provide three 2.5 gallon buckets with an attached lanyard; each bucket marked with the
vessel's name as required by 46 CFR 181.610
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Engineering › Steering Gear System › Rudder
Issued 11 August 2005
Resolved
Prove proper operation of main steering in accordance with 46 CFR 182.610, 46 CFR 176.814, 46 CFR 176.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Engineering › Steering Gear System › Yoke
Issued 11 August 2005
Resolved
Prove proper operation of auxiliary steering 46CFR182.620
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 11 August 2005
Resolved
Prove proper operation of main engine in Accordance with 46 CFR 176.804,
46 CFR 182.200, 46 CFR 184.620(b), (46 CFR 175.00-29), 46 CFR 182.410(b), (46 CFR 182.15-5(b))
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 August 2005
Resolved
Perform fire and man overboard drills as required by 46 CFR 185.504.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Resolution: Drills completed
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 August 2005
Resolved
Provide two portable lights as required by 46 CFR 183.430.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 August 2005
Resolved
Provide protective cover for battery as required by 46 CFR 183.354.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Communications › Alarms/Indicators › High Water Alarm
Issued 11 August 2005
Resolved
Prove proper operation of bilge high level alarms as required by 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Engineering › Bilge Water Management System › Pump
Issued 11 August 2005
Resolved
Provide operation of portable bilge pump as required by 46 CFR 182.520(b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Engineering › Bilge Water Management System › Pump
Issued 11 August 2005
Resolved
Provide proof of the operation of submersible electric bilge pumps with visual indicator at pilothouse as required by 46 CFR 182.530(c).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 11 August 2005
Resolved
Prove the proper operation of engine room ventilation shut downs as required by 46 CFR 182.465.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Resolution: shutdowns working properly
Fire Fighting › Remote Fuel Shutoff › General
Issued 11 August 2005
Resolved
Prove the proper operation and location of all fuel shutoff valves IAW 46 CFR182.455(b)(4).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 August 2005
Resolved
Prove the proper operation of the wet exhaust IAW 46 CFR 182.430.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Communications › Alarms/Indicators › General Alarm
Issued 11 August 2005
Resolved
Provide proof of the operation of engine temperature gauge as required by 46 CFR 182.422.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Communications › Alarms/Indicators › General Alarm
Issued 11 August 2005
Resolved
Provide proof of the operation of engine RPM and oil pressure gauges IAW 46 CFR
182.410.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 11 August 2005
Resolved
Repair holes in engine space bulkheads to make engine space vapor tight
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Resolution: holes repaired
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 August 2005
Resolved
Prove wiring running from engine battery (radio power cable?) is correct wire size and has proper overcurrent protection as required by 46CFR183.340 and .380
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 August 2005
Resolved
Provide machinery guard for engine rotating belt IAW 46CFR177.960
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Resolution: Guard provided
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 11 August 2005
Resolved
Repair/replace 2 B-II fire extinguishers where bottoms are rusting as required by 46CFR176.810
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Resolution: replaced extinguishers
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 August 2005
Resolved
Prove proper operation of ring buoy waterlight as required by 46CFR180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2006
Lifesaving › Lifebuoys › Stowage
Issued 11 August 2005
Resolved
Properly stow ring buoy as required by 46CFR180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Resolution: Ring buoy stowed.
Operations/Management › Drills/Instruction
Issued 18 February 2004
Resolved
Provide training, lifesaving equipment maintenance and bridge logs in accordance with 46CFR 185.420, 185.702, and 185.520. LEGACY COMPONENT DESC: Logs
Due 18 March 2004
Resolved 1 March 2004
Resolution: Training, lifesaving equipment maintenance and bridge logs provided on board vessel.
Operations/Management › Passenger Operations
Issued 18 February 2004
Resolved
Provide passenger count as required by 46 CFR 185.504. LEGACY COMPONENT DESC: Passenger count
Due 18 March 2004
Resolved 1 March 2004
Resolution: Vessel commenced logging passenger count.
Operations/Management › Drills/Instruction
Issued 18 February 2004
Resolved
Post emergency instructions as required by 46 CFR 185.510. LEGACY COMPONENT DESC: Emergency Instruction
Due 18 March 2004
Resolved 1 March 2004
Resolution: Emergency instructions posted in common passenger and crew areas.
Navigation › Piloting/Steering
Issued 18 February 2004
Resolved
Provide compass as required by 46 CFR 184.402. LEGACY COMPONENT DESC: Magnetic Compass
Due 18 March 2004
Resolved 1 March 2004
Resolution: Compass installed on vessel.
Navigation › Collision/Grounding Avoidance
Issued 18 February 2004
Resolved
Provide navigation bell as required by 33 CFR part 86. LEGACY COMPONENT DESC: Bell
Due 18 March 2004
Resolved 1 March 2004
Resolution: Bell provided and affixed to vessel.
Operations/Management › Passenger Operations
Issued 18 February 2004
Resolved
Provide passenger safety orientation as required by 46 CFR 185.506. LEGACY COMPONENT DESC: Safety Orientation
Due 18 March 2004
Resolved 1 March 2004
Resolution: Operator conducted/demonstrated passenger orientation for emergencies.
Lifesaving › Lifebuoys
Issued 18 February 2004
Resolved
Renew ring lifebouy as per 46 CFR 185.516.
Due 18 March 2004
Resolved 1 March 2004
Resolution: Lifebuoy replaced.
Fire Fighting › Miscellaneous Items
Issued 18 February 2004
Resolved
Mark fire buckets with vessel's name as required by 46 CFR 181.610. LEGACY COMPONENT DESC: Buckets
Condition: Unknown
Due 18 March 2004
Resolved 1 March 2004
Resolution: Fire buckets were correctly labeled with vessel''''s name.
Engineering › Bilge Water Management System
Issued 18 February 2004
Resolved
Provide a light or other visual means at the bilge pump control point to indicate operation as required by 46 CFR 182.520(a).
Condition: Unknown
Due 18 March 2004
Resolved 18 March 2004
Resolution: Owner/operator installed visual indicator at operating station.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 February 2004
Resolved
Repair and prove that forward engine room bulkhead is vapor tight as required by 46 CFR 177.405(e).
Due 18 March 2004
Resolved 1 March 2004
Resolution: Forward bulkhead of engine was sealed to make vapor tight.
Engineering › Ventilation
Issued 18 February 2004
Resolved
Provide a means for closing all supply and exhaust ducts to engine compartment ventilation as required by 46 CFR 182.465(h). LEGACY COMPONENT DESC: Ventilation
Due 18 March 2004
Resolved 1 March 2004
Resolution: Vessel provided mechanical device to close engine room ventilation system.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 18 February 2004
Resolved
Replace existing dry chemical fire extinguisher in engine room with CO2 portable extinguisher as per certificate of inspection as required by 46 CFR 181.500(a).
Condition: Unknown
Due 18 March 2004
Resolved 1 March 2004
Resolution: CO2 fire extinguisher was provided in lieu of chemical extinguisher for engine compartment.
Navigation › Collision/Grounding Avoidance
Issued 11 January 2002
Resolved
REPAIR/REPLACE FORWARD NAVIGATION LIGHTS. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Due 17 February 2002
Resolved 21 February 2002
Navigation › Emergency Steering
Issued 11 January 2002
Resolved
PROVIDE EMERGENCY STEERING TILLER.
Condition: Improper/Lack of Maintenance
Due 17 February 2002
Resolved 21 February 2002
Lifesaving › Hand Flares
Issued 11 January 2002
Resolved
PROVIDE THREE (3) CG APPROVED NIGHT VISUAL DISTRESS SIGNALS. VESSEL IS LIMITED TO DAYLIGHT OPERATIONS ONLY UNTIL NIGHT DISTRESS SIGNALS ARE PROVIDED. LEGACY COMPONENT DESC: Night Visual Distress Signals
Condition: Improper/Lack of Maintenance
Due 17 February 2002
Resolved 21 February 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 January 2002
Resolved
PROVIDE AND POST LIFEJACKET DONNING PLACARDS.
Condition: Improper/Lack of Maintenance
Due 17 February 2002
Resolved 21 February 2002
Lifesaving › Lifebuoys
Issued 11 January 2002
Resolved
PROVIDE SIXTY (60) FEET OF POLY PROPOLYNE LINE FOR RING BUOY. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Due 17 February 2002
Resolved 21 February 2002
Engineering › Sea-water System (primary cooling)
Issued 11 January 2002
Resolved
REPAIR/REPLACE RAW WATER COOLING VALVE FOR MAIN ENGINE COOLING SYSTEM. SHOW PROPER OPERATION UPON REPAIR. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 17 February 2002
Resolved 21 February 2002
Engineering › Sea-water System (primary cooling)
Issued 11 January 2002
Resolved
REPLACE FLEXIBLE HOSE FOR MAIN ENGINE RAW WATER COOLING SYSTEM. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 17 February 2002
Resolved 21 February 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 11 January 2002
Resolved
CONDUCT ANNUAL SERVICING FOR BII PORTABLE FIRE EXTINGUISHER. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 17 February 2002
Resolved 21 February 2002
Electrical › Electric Supply System (service)
Issued 11 January 2002
Resolved
PROPERLY SECURE BATTERY BOXES AND PROVIDE COVER. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 17 February 2002
Resolved 21 February 2002
Lifesaving
Issued 16 April 2001
Resolved
PROVIDE 3 ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Lifesaving
Issued 16 April 2001
Resolved
PROVIDE APPROVED FIRST AID KIT.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Construction/Loadline
Issued 16 April 2001
Resolved
PROVIDE OPERABLE HIGH BILGE ALARM - MAKE REPAIRS.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Documentation
Issued 17 October 1994
Resolved
Conduct simplified stability test prior to carrying passengers.
Condition: Unknown
Due 8 December 1994
Resolved 8 December 1994