MAURY USCG vessel records
← All vessels

CARNIVAL LEGEND

CARNIVAL LEGEND is a 2002 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 2016, most recently in April 2026, along with 55 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 17 April 2026.

Built
2002
Last inspected
17 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9224726
588038
Flag
BAHAMAS, THE
Maury page id
psix-588038

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded37
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it85942 - Convention (Subpart B), Gross Ton
53626 - Convention (Subpart B), Net Ton
46506 - Displacement, Ton
8983 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NEVER NEVER LAND IV Passenger (Inspected) · MISLE 370641 · 2 February 2020 · activity 6905999

Inspection history · 72

17 April 2026 COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8351454
10 November 2025 PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8265739
5 June 2025 COC-CVE Quarterly · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8152275
15 May 2025 PSC B
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8137060
21 April 2025 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8116195
21 December 2024 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8051174
8 December 2024 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8046163
10 November 2024 COC-CVE Annual · PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8029717
7 April 2024 PSC B · COC-CVE Quarterly
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7888448
28 January 2024 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7857107
5 November 2023 Deficiency Check · PSC A · COC-CVE Annual
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7819973
20 September 2023 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7795796
30 April 2023 PSC B · Deficiency Check · COC-CVE Quarterly
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7677506
12 March 2023 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7650615
30 October 2022 Deficiency Check · PSC A · COC-CVE Annual
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7584584
26 October 2022 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7586432
23 October 2022 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7583032
22 September 2022 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7564782
8 May 2022 ISPS Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7446145
13 December 2021 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7367060
13 December 2021 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7367334
12 December 2021 MARPOL Annex I Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7366544
10 November 2021 PSC A · COC-CVE Annual
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7348586
7 November 2021 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7347581
24 April 2020 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6943381
3 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935044
9 March 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6927260
17 February 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6911470
16 February 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6912893
2 February 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6905999
20 December 2019 Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6877859
30 November 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6868659
17 November 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6864003
3 November 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6850675
3 November 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6850691
18 October 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6837528
10 October 2019 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6832052
6 October 2019 ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6829116
20 September 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6885521
16 September 2019 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6812643
13 September 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6851024
30 April 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6673516
23 April 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6669806
19 April 2019 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6662985
17 June 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6495640
2 June 2018 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6432137
1 June 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6442634
14 May 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6414196
21 April 2018 COC-CVE Annual · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6396058
20 September 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6272013
1 August 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6230006
9 June 2017 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6175087
7 June 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6168498
8 May 2017 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6141738
19 April 2017 Ballast Water Examination · In-Service Inspection · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6124158
13 January 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6070573
23 September 2016 PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6007823
7 September 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6005426
31 August 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5995140
11 August 2016 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5969916
23 July 2016 MARPOL Annex IV Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5950374
22 July 2016 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6028851
7 July 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5954757
7 July 2016 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6318175
21 June 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5940633
15 June 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5940348
15 June 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5940517
31 May 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5908737
25 May 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5888461
23 May 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5884803
6 May 2016 Ballast Water Examination · COC-CVE Annual · ISPS II Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5866651
25 April 2016 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5862504

Deficiency record · 55

09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 17 April 2026 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed loosed connections on lube oil sump line for number three main diesel engine. 74 SOLAS 04 II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2026
Resolved 23 April 2026
Resolution: Vessel corrected loosed connections prior to inspection team departure from vessel.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 17 April 2026 Resolved
The number of openings in watertight bulkheads shall be reduced to the minimum compatible with the design and proper working of the ship; satisfactory means shall be provided for closing theses openings. PSCO observed a missing insulation block from from a multi cable transit in water tight bulk head in engine room. 74 SOLAS 04 II-1.15.1
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2026
Resolved 23 April 2026
Resolution: Inspection team observed watertight fitting replacement prior to departure from vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 17 April 2026 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/42 or II-1/43. PSCO observed extinguished embarkation lights at lifeboats 3,5,9, and 11. 74 SOLAS 20 III/11.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2026
Resolved 24 April 2026
Resolution: Class report attached.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 April 2026 Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (14) below. Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. The title of each category is intended to be typical rather than restrictive. The number in parentheses preceding each category refers to the applicable column or row in the tables. PSCO observed combustibles stowed in A/C machinery space on deck 4 midships in main vertical zone 2. 74 SOLAS 01 II-2/26.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2026
Resolved 23 April 2026
Resolution: Combustibel storage items were removed from location prior to completion of inspection.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 June 2025 Resolved
74 SOLAS 20 II-2/9.2.2.3.4.6 16ac ELECTRICALLY HEATED OVENS SHALL BE PROVIDED WITH A TIMER. PSCO FOUND MALE SAUNA, WHICH IS ELECTRICALLY HEATED, MISSING THE TIMER.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 20 June 2025
Resolution: Vessel sent correspondence attesting to addition of sand timer to sauna - meeting SOLAS regulations. See documents tab for pictures.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 May 2025 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. The stowage of combustibles is prohibited in a category 10 space. PSCO observed the stowage of combustible materials inside category 10 space. PSCO observed carboard boxes in F.S.D.A 3.6.08. 74 SOLAS 01 2-2/26.2.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 15 May 2025
Resolution: Removed
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 10 November 2024 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. A life raft for use with an approved launching appliance shall: be provided with means for bringing the life raft alongside the embarkation deck and holding it securely during embarkation. During deployment of life raft, PSCOs observed the breaking system for life raft crane #3 to be inoperable and unable to hold the weight of the life raft, causing the life raft to lower uncontrollably. 74 SOLAS III/34 LSA CODE 4.1.4.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2024
Resolution: Breaking system repaired and operational check completed satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 November 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed the fuel shutoff valve for lifeboat #12 was seized open, preventing the cutoff of fuel in the event of an engine fire. 74 SOLAS 20 III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2024
Resolution: Fuel shutoff valve replaced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 November 2024 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. The stowage of combustibles is prohibited in a category 10 spaces. PSCO observed the stowage of combustible materials inside category 10 spaces, F.S.D.A.2.08 and F.S.D.3.6.08. PSCO observed stowage of combustible materials in both sides of the water making room and forward tank room. Additionally, PSCOs observed storage of combustible materials in the unfinished shower spaces in all Cloud 9 massage rooms. 74 SOLAS 01 II-2/26.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2024
Resolution: Items removed and stowed in properly categorized spaces.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 November 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10s from the beginning of their movement. PSCO observed fire doors TT.2.03 closing outside of the maximum time of 40s, and fire doors F.S.D.3.5.15, TT.2.02 and C.2.04 closing quicker than the minimum time of 10s. 74 SOLAS 01 II-2/30.4.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2024
Resolution: Doors adjusted to achieve proper closure rate.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 10 November 2024 Resolved
Each survival craft shall be stowed fully equipped as required by this chapter and the Code... Except in the vicinity of the rudder and propeller, suitable handholds shall be provided or a buoyant lifeline shall be becketed around the outside of the lifeboat above the waterline and within reach of a person in the water. PSCOs observed missing buoyant lifeline on outside, aft, port side on lifeboat/tender #4. 74 SOLAS 20 III/13.1.4
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 November 2024
Resolution: Received class survey report/photos attesting to lifeboat/tender #4 lifeline repair.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 November 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10s from the beginning of their movement. PSCO observed fire doors TT.2.03 closing outside of the maximum time of 40s, and fire doors F.S.D.3.5.15, TT.2.02 and C.2.04 closing quicker than the minimum time of 10s. 74 SOLAS 01 II-2/30.4.12
Action required: 10 - Deficiency Rectified
Resolved 10 November 2024
Resolution: Door adjusted to achieve proper closure rate.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 November 2024 Resolved
The arrangements for the storage, distribution and utilization of oil used shall be such as to ensure the safety of the ship and persons onboard. PSCOs observed oil accumulation around sludge transfer pump in engine room. 74 SOLAS 01 II-2/15.2
Action required: 10 - Deficiency Rectified
Resolved 10 November 2024
Resolution: Oil accumulation removed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 November 2024 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCOs observed sprinkler head located in the port side, deck 9 men's locker room shower stall drained of red ampule fluid. 74 SOLAS 20 II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 10 November 2024
Resolution: Sprinkler head replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 November 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10s from the beginning of their movement. PSCO observed a wooden pallet blocking FD F.S.D.A.2.08, preventing it from closing properly. 74 SOLAS 01 II-2/30.4.2
Action required: 10 - Deficiency Rectified
Resolved 10 November 2024
Resolution: Wooden pallet removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 April 2024 Resolved
One portable fire extinguisher intended for use in any space shall be stowed near the entrance to that space. The fire extinguisher located in the incinerator room was not mounted in an approved bracket. 74SOLAS(01)II-2/6.6 10c
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: extinguisher mounted in approved bracket
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 April 2024 Resolved
Where A class divisions are penetrated for the passage of electrical cables, pipes, trunks, ducts, etc., or for girders, beams or other structural members, arrangements shall be made ensure that the fire resistance is not impaired. Deck 2 elevator lobby FZ 2 Fr. 96 cabling passing through the overhead not properly insulated. 74SOLAS(01)II-2/18.1.1 10c
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: boundary penetration insulated to meet SFP
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 April 2024 Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the Code. All life-saving appliances shall be fitted with retro-reflective material where it will assist in detection. Lifeboat #1 missing retro-reflective tape on top of cabin in way of operator hatch port and starboard. 74SOLAS(20)III/34 LSA code 1.2.2.7 10c
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: retro tape replaced on lifeboat
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 April 2024 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. AC space (cat 10) deck 3 aft of theater has combustibles stored inside. 74SOLAS(01)II-2/26.2.2 10c
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: combustibles removed from space
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 April 2024 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Storage of combustibles was identified in the steering gear room (cat 10). 74SOLAS(01)II-2/26.2.2 10c
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: combustibles removed from space
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 April 2024 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Flammable materials were identified as being stored in carpenter's workshop (cat 13). 74SOLAS(01)II-2/26.2.2
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: flammable material removed from space.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 April 2024 Resolved
Within the perimeter of such stairway enclosures, only public toilets, lockers of non-combustible material providing storage for non-hazardous safety equipment and open information counters are permitted. Found hazardous material spill kit and associated material under stairway 0 deck aft MVZ 8. 74SOLAS(01)II-2/29.2 10c
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: spill kit removed from stairway
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 April 2024 Resolved
Doors and door frames in B class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions, this being determined in accordance with the Fire Test Procedures Code except that ventilation openings may be permitted in lower portion of such doors. B-15 door behind stage leading to dressing room was found with wedges preventing door from closing. 74SOLAS(01)II-2/9.4.1.1.2 10c
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: wedges removed from door
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 April 2024 Resolved
Within the perimeter of such stairway enclosures, only public toilets, lockers of non-combustible material providing storage for non-hazardous safety equipment and open information counters are permitted. Luggage cart with cleaning supplies was found in cat 2 passenger aft stairway deck 2. 74SOLAS(01)II-2/29.2 10c
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: cart removed from stairway
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 November 2023 Resolved
Not less than on half of the total number of lifebuoys shall be provided with lifebuoy self-Igniting lights, not less than two of these shall also be provided with lifebuoy self-activating smoke signals and be capable of quick release from the navigation bridge complying with the requirements of paragraph 2.1.2 of the LSA Code. Lifebuoy waterlight near lifecraft crane 6 has a Duracell MN908 battery which is not on the manufacturer's battery list on the ACR SM-2 label. It is to be verified that all lifebuoy lights onboard have the proper battery type to the satisfaction of the RO. 74 SOLAS 20 III/7.1.3 11117 - 16a
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2023
Resolved 23 November 2023
Resolution: Received DNV report N2570350, which reported that the batteries on all 25 waterlights were reported to be changed out to the proper type, as verified by attending DNV surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 November 2023 Resolved
During preparation and launching, the survival craft, its launching appliance, and the area of water into which it is to be launched shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation 111/42. The emergency lighting illuminating the water between lifeboats #9 and #11 (stbd side), between lifeboats #1 and #3, and 2 of 3 bulbs on emergency lighting between lifeboats #10 and #12 were found inoperable at time of boarding to commence the examination. 74 SOLAS 20 III/16.7 11112 - 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 19 November 2023
Resolved 5 November 2023
Resolution: Light bulbs were replaced prior and confirmed working properly by the completion of the exam.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 5 November 2023 Resolved
A minimum of 2 two-way radiotelephone apparatus for each fire party for fire-fighter's communication shall be carried on board. Those two-way portable radiotelephones shall be of an explosion-proof type I or intrinsically safe. Ships constructed before 1 July 2014 shall comply with the requirements of this paragraph not later than the first (SOLAS Safety Equipment) survey after 1 July 2018. Spot-checking of radios used by the fire party found some Motorola DGP 5050 radios with Motorola PMNN4544A batteries. The label on the radio states that the radio is intrinsically safe only when used with Motorola batteries NNTN8129A. Also we found a Motorola XPR 7550 with an unlabeled battery. RO to verify that all radios (And associated batteries) used by the fire party are properly rated as explosion-proof or intrinsically safe. 74 SOLAS 20 11-2/10.10.4 07111 - 50a
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2023
Resolved 13 January 2024
Resolution: Received DNV survey report attesting that the batteries for the firefighter radios were replaced with batteries of the intrinsically safe type.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 November 2023 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. PSCO observed 03 flights of stairs on deck A, stairs C260 to WTC 13 with inoperable low location lighting. The means of escape, including stairways and exits, shall be marked 74 SOLAS 01 11-2/28.1.5.10 by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. PSCO observed 03 flights of stairs on deck A, stairs C260 to WTC 13 with inoperable low location lighting. 74 SOLAS 01 11-2/28.1.5.10 07120-10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 November 2023
Resolved 5 November 2023
Resolution: Low Location Lighting was fixed prior to PSCO's departing the vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 April 2023 Resolved
07120 - The escape markings must enable PAX to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be photo-luminescent material or marked by lighting. The emergency escape route to exit the OWS Compartment is not appropriately marked; therefore the escape ladder is not readily visible or easy to find within the compartment. Additional marking is needed to guide a person to the escape ladder. 74 SOLAS (01) II-2/28.1.5.10 16ac
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2023
Resolved 12 May 2023
Resolution: Received LR report no. 2199159, attesting that additional signage for the escape route has been provided to the satisfaction of the LR surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 30 April 2023 Resolved
07122 - General arrangement plans shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions, the sections enclosed by "B" class division together with particulars of the fire detection and fire alarm systems the sprinkler installation particulars of the fan control positions, the position of dampers and identification numbers of the ventilating fans serving each section. Plans and booklets shall be kept up to date; any alterations thereto shall be recorded as soon as practicable. In 2018, there was a modification in Deck 3, MVZ4 were the existing "fun Shops" was reconfigured to include a "promo" spaces in the center category (8) Rodeo Drive. The fire control approved on 21SEP2022 does not reflect these modifications. 74 SOLAS (20) II-2/15.2.4.1 50ac
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2023
Resolved 12 May 2023
Resolution: Received LR report no. 2199159, attesting revised Fire Control Plan dated 5/9/23 has been approved by LR and provided onboard. This revision includes the modifications in deck 3, MVZ4 to the fun shops; promo spaces.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 30 April 2023 Resolved
11131 - Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Lifeboat operator of outboard lifeboat #6 and #8 was not familiar with the proper operation of #8 lifeboat and could not locate the fuel shutoff and first aid kit in #6. 74 SOLAS (20) III/19.2.1 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2023
Resolved 12 May 2023
Resolution: Received LR report no. 2199159, attesting that additional training was provided to lifeboat operators on 5/5/23 and the trained attendant sheet/record was reviewed to the LR surveyor’s satisfaction.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 April 2023 Resolved
07109 - Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler, fire detection and fire alarm system of an approved type and complying with the requirements of regulation 12. Sprinklers shall be placed in an overhead position and spaced in a suitable pattern to maintain an average application rate of not less than 5L/m^2/min over the nominal area covered by the sprinkler. The compartment at FSDA6.05 had artwork with frames stored above the line necessary to allow effective coverage by the sprinklers installed in the compartment. 74 SOLAS (01) II-2/36.1.2 and 12.3 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 30 April 2023
Resolution: By the completion of the COC exam, the storage of artwork in the subject compartment was adjusted to ensure all storage was below the max height line.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 October 2022 Resolved
Within the perimeter of such stairway enclosures, only public toilets, lockers of non-combustible material providing storage for safety equipment and open information counters, are permitted. Category two stairways on multiple decks had free standing hand sanitizer dispensers and different advertisement free standing signs. 74 SOLAS 01 II-2/29.2
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 4 November 2022
Resolution: Received LR report 2174312, reporting that freestanding hand sanitizers were removed and 13 wall-mounted units provided instead. Advertisement signs removed, and hotel director confirmed that signs only put in place when responsible staff present.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 October 2022 Resolved
A door designed to reopen upon contacting an object in its path shall reopen not more than 1m from the point of contact. Class "A" door in front of Sauna (F.S.D. 9.5.0.4) reopened more than 1m from point of contact. 74 SOLAS 01 II-2/30.4.11
Action required: 15 - Rectify deficiencies by next port
Resolved 4 November 2022
Resolution: Received LR report no. 2174312, reporting that the pneumatic mechanism for FSD 9.5.0.4 was adjusted by engineer and confirmed in proper working condition by LR as part of remote survey.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 October 2022 Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions except that the ventilation openings may be permitted in the lower portion of such doors. B-15 door from top deck of the gym (Deck 10) leading to corridor did not fully close and latch. 74 SOLAS 01 II-2/31.1.1
Action required: 15 - Rectify deficiencies by next port
Resolved 4 November 2022
Resolution: Received LR report no. 2174312. It is reported that the B-15 door in question was repaired by the crew and confirmed in proper working order as part of LR remote survey.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 30 October 2022 Resolved
An International Load Line Certificate shall not be delivered to the ship until the surveyor has certified the marks are correctly and permanently indicated. Load Line on the hull of the ship did not match International Load Line Certificate. ILLC Reg 9
Action required: 10 - Deficiency Rectified
Resolved 30 October 2022
Resolution: Attending LR surveyor issued updated ILLC prior to completion of the COC-annual exam.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 May 2022 Resolved
Escape routes shall be maintained in safe condition. Approximately 15 chairs were stored in a corridor outside the art gallery conference room impeding the width of the corridor and blocking visibiity of the low location lighting. Additonally, stairwell 60 on decks 3, 4, & 5 meas of escape were significantly impeded by unattended luggage. SOLAS 20 II-2/13.1.2
Action required: 10 - Deficiency Rectified
Due 11 May 2022
Resolved 8 May 2022
Resolution: Deficiency corrected on the spot. Chairs and lugagge were moved and stored properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2022 Resolved
All Life-saving appliances shall be fitted with retro-reflective material where it will assist in detection. Lifeboys throughout deck 3 have deteriorated retro-reflective tape. SOLAS 20 III/34 LSA 1.2.7
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 11 May 2022
Resolved 16 May 2022
Resolution: Received LR report no. 2155593 via email from the vessel. It is reported that LR conducted a remote survey on 5/13/22 and cleared the deficiency. No amplifying information on the exact nature of the corrective actions was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 8 May 2022 Resolved
Where davit arms are recovered by power, safety devices shall be fitted shich will automatically cut off power to the davit arms before the davit arms reach the stops. The limit switches on liferaft stations No.4 and No.8 were inoperable. SOLAS 20 III/16
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 11 May 2022
Resolved 16 May 2022
Resolution: Received LR report no. 2155593 via email from the vessel. It is reported that LR conducted a remote survey on 5/13/22 and cleared the deficiency. No amplifying information on the exact nature of the corrective actions was provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2022 Resolved
Crew members shall be trained to be familiar with the arragements of the ship. Th emain laundry attendant, medical administrative assitant, and assitant waitress in Truffles Restaurant were unfamiliar with the spaces and how to make notification of or address a fire in those spaces. 74 SOLAS II-2/15.2.2.1
Action required: 15 - Rectify deficiencies by next port
Due 22 May 2022
Resolved 16 May 2022
Resolution: Received LR report no. 2155593 via email from the vessel. It is reported that LR conducted a remote survey on 5/13/22 and cleared the deficiency. No amplifying information on the exact nature of the corrective actions was provided.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 May 2022 Resolved
Doors in "B" class divisions shall be provided with a method of closure which shall have fire resistance equivalent to the division. PSCO Observed a B15 doo rby elevator 10 on deck 3 was unable to close. SOLAS 20 II-/9.4.1.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 May 2022
Resolved 16 May 2022
Resolution: Received LR report no. 2155593 via email from the vessel. It is reported that LR conducted a remote survey on 5/13/22 and cleared the deficiency. No amplifying information on the exact nature of the corrective actions was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 May 2022 Resolved
During preparation and launching, the survival craft, it launching appliance, and the area of the water which it is to be launched shall be adequately illuminated. Emergency lights by lifeboats No. 1, the starboard side rescue boat, and the second to last light starboard side aft were inoperable. SOLAS 20 III/16.7
Action required: 10 - Deficiency Rectified
Due 8 May 2022
Resolved 8 May 2022
Resolution: Deficiency was rectify on the spot by changing the inoperable lights.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 November 2021 Resolved
07105 - Fire screen doors in "A" class divisions that are designed to reopen upon contacting an object in their path shall reopen not more than 1 m from the point of contact [30.4.11]. Multiple sliding fire screen doors on decks 3 through 7 found to reopen >1m after contacting an object in their path. SOLAS (01) II-2/30.4.11
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2021
Resolved 13 December 2021
Resolution: Received Class Survey Report rectifying this deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 November 2021 Resolved
11129 - Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Limit switch for liferaft davit #4 inoperable. SOLAS (20) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2021
Resolved 13 December 2021
Resolution: Received Class Survey Report rectifying this deficiency.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 10 November 2021 Resolved
04109 - Fire drills shall be conducted in accordance with provisions of regulations III/19.3 [15.2.2.5]. Parties responsible for fire extinguishing shall be organized and these parties shall have the capability to complete their duties at all times [15.2.1.3]. During initial fire drill (scenario: fire in main galley), fire squad assigned to carry out search and rescue of any personnel casualties did not locate the simulated personnel casualty placed in the space by the ship's staff, although the casualty was reported to the bridge as found and removed from the space. Also, fire screen doors enclosing the escalators that pass from the main galley up into the dining room were not closed, which could permit spread of fire into the large dining room area (spans 2 decks). SOLAS (20) II-2/15.2.2.5 and 15.2.1.3
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 10 November 2021
Resolved 10 November 2021
Resolution: Second fire drill carried out satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 6 October 2019 Resolved
Before the hip leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat tender #3 steering found inoperable on starboard side. Emergency steering remains operational.
Action required: 15 - Rectify deficiencies by next port
Due 11 October 2019
Resolved 7 October 2019
Resolution: Recieved class report from LR
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 September 2019 Resolved
All fire doors in stairway enclosures main vertical zone bulkheads and galley boundaries which are normally kept open shall be capable of release from a cerntral control station and from a position at the door. Fire doors A.4.22 and A.4.12 are sliding fire doors between the crew galley and crew mess. They are not responding to centralized control. 97 SOLAS Ch. II-2 Regulation 41-1 6.5
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 September 2019
Resolution: Rectified via class report.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 April 2019 Resolved
In spaces where a limited supply of flammable liquids is necessary, it is permissible to install an approved flammable liquid cabinet to stow small quantities for daily use. The cabinet must be at least at the level required by SOLAS II-2. Identified an NFPA 30 cabinet in starboard side storeroom, Deck 2, MVZ 6. Storeroom is listed as a category 13 space on the vessel's approved space categorization plan. Cabinets meeting NFPA 30 only provide protection for 10 minutes and should only be used in Category 11, 12 or 14 spaces. 74 SOLAS (01) II-2/26.2.2
Action required: 10 - Deficiency Rectified
Due 19 April 2019
Resolved 19 April 2019
Resolution: Chemicals were removed from space and stored in the paint locker.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 April 2019 Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces, at least one of which shall give access to a stairway forming a vertical escape. Deck 10, MVZ 6 gymnasium port side emergency exit door is capable of being locked. 74 SOLAS (01) II-2/28.1.2
Action required: 10 - Deficiency Rectified
Due 19 April 2019
Resolved 19 April 2019
Resolution: Lock was removed; door handle/plate changed out.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 April 2019 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Lifeboat #4 stbd engine did not start. 74 SOLAS (14) III/20.2
Action required: 10 - Deficiency Rectified
Due 19 April 2019
Resolved 19 April 2019
Resolution: Lifeboat engine was started after second attempt.
Lifesaving › Launching Appliances › Release Mechanism
Issued 21 April 2018 Resolved
0630 - Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use; the forward release hook on Lifeboat #16 and Lifeboat #12 did not release properly. Crew attempted to rectify without success. Due to (02) lifeboats not being deployable, total capacity of lifeboats available onboard has been reduced to 2400 people, and total number of persons allowed on board has been reduced to 3200 persons to maintain compliance with 74 SOLAS (14) III/21.1.1.1 74 SOLAS (14) III/20.2
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2018
Resolved 14 May 2018
Resolution: Received PSSC and COC Interim certificate of RO.
Electrical › Electrical Distribution System (emergency) › Ground Indicator
Issued 21 April 2018 Resolved
9800 - Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured; circuits for the ADG fan and DG room aft supply fan #5651/042 were ground faulted causing the insulation resistance on the emergency switchboard to be lower than the program alarm threshold. Vessel is to tag both circuits out and repair to the satisfaction of class.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2018
Resolved 2 June 2018
Resolution: Received class report attesting to repairs of 02 CG-ID'd grounds and 03 additional grounds located during repair process.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 7 June 2017 Resolved
1510-Navigation Equipment-Ship is to be fitted with a functioning voyage data recorder. Ships's VDR triggered the off-line alarm and is not showing any ship's data on the bridge monitor-74SOLAS14 cons. V/20.1.1
Action required: 15 - Rectify deficiencies by next port
Resolved 10 June 2017
Resolution: Received service technician report attesting to the proper repair and operation of the Voyage Data Recorder.
Lifesaving › Lifeboat › Carriage Requirement
Issued 20 April 2017 Resolved
According to PSSC, the #2 tenderboat is currently out of service due to hull damage and the vessel's remaining non-substandard lifeboats do not meet the 75% carriage capacity. Total persons reduced by 150.*TENDERBOAT HULL DAMAGE REPAIRED, HOWEVER, FULL LOAD TESTING MUST BE COMPLETED PRIOR TO RETURNING TO SERVICE AND APPROVED BY RO. 74 SOLAS (09) REG III 21.1.1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 8 May 2017
Resolution: #2 Tender boat hull damage repaired. Full load test completed. Raised total persons onboard to 3600.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 23 May 2016 Resolved
Inoprerable Echo Depth Sounder
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 24 May 2016
Resolution: Work order attesting to the working condition of the Echo Depth Sounder was provided.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.