Records from 2004 to 2026. Most recent: inspection, 26 June 2026.
Inspection history · 27
26 June 2026
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8416503
19 March 2026
Annual Inspection · MSP Select Additional Oversight – Risk Assessment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8328327
10 February 2026
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8308504
7 May 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8129883
9 July 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7955006
29 February 2024
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7872692
14 February 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7865683
2 February 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7859821
20 April 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7673047
29 March 2022
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7421597
28 March 2022
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7419751
10 January 2022
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7374139
17 June 2021
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7227834
5 February 2021
Administrative Inspection · Security Breach
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7137337
28 July 2020
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7018007
9 July 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7001960
6 January 2020
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6883217
15 May 2019
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6684660
10 May 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6410781
4 May 2018
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6405956
17 April 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6393610
22 February 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392239
8 February 2018
Annual Inspection · Security Breach · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6352447
30 October 2017
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6297571
14 April 2017
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6124267
25 March 2016
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5837283
4 January 2016
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5790671
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 March 2026
Resolved
"A vessel must be provided with a satisfactory arrangement for draining any watertight compartment." MI observed." MI observed crack on the sea strainer for the bilge manifold system preventing system from providing adequate suction. Temporary repairs made by creating seal with flex seal, but repairs are not satisfactory. Make satisfactory repairs within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2026
Resolved 27 March 2026
Resolution: New sea strainier installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 March 2026
Resolved
"All electrical equipment and circuits must be clearly marked and identified." MI observed main 208V/120V breaker panel in galley with missing and incorrect labels. Properly label switches in breaker panel within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2026
Resolved 26 March 2026
Resolution: Received photos for 208V/120V breaker panel in galley correctly labeled.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 19 March 2026
Resolved
"A durable placard must be posted next to all radiotelephone installations with information specific to the individual vessel." MI observed placard at radiotelephone installation with incorrect FCC call sign. Make appropriate updates to reflect correct information on placard within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2026
Resolved 27 March 2026
Resolution: updated emergency broadcast placard
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2025
Resolved
"Electrical equipment on a vessel must be installed and maintained to: minimize accidental personnel contact with energized parts." MIs observed dead end wiring in the 3rd deck lifejacket stowage where motor for air compressor is wired in. Cover or remove dead end wires.
46 CFR 120.200
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2025
Resolved 13 May 2025
Resolution: Dead end wiring removed
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 May 2025
Resolved
"The main steering gear and rudder stock must be: of adequate strength..." MIs observed hydraulic leak on port side steering ram. Fix leak.
46 CFR 102.610(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2025
Resolved 30 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2025
Resolved
"A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment." MIs observed fuel in the RACOR bowl for starboard side engine. Fix strainer.
46 CFR 58.25-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2025
Resolved 13 May 2025
Resolution: Fuel removed from bowls; seals replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2025
Resolved
"Each lighting fixture and lampholder must be fixed." Overhead lighting fixture in bow thruster space was found hanging by zip ties and not properly secured. Secure lighting fixture.
46 CFR 120.410(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2025
Resolved 13 May 2025
Resolution: Lighting fixture replaced
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 May 2025
Resolved
"The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable." Port side main engine seal found with fuel leak. Repair leak.
46 CFR 116.405(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2025
Resolved 30 July 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 May 2025
Resolved
"Internal combustion engine exhausts, boiler and galley uptakes, and similar sources of ignition must be kept clear of combustible material." Grease extraction hood in galley found with excessive grease. Clean grease extraction hood.
46 CFR 116.405(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2025
Resolved 30 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 9 May 2025
Resolved
"An enclosed or partially enclosed space within a vessel must be adequately ventilated in a manner suitable for the space." Ventilation duct in galley is corroded through. Repair duct.
46 CFR 116.600(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2025
Resolved 30 July 2025
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 May 2025
Resolved
"Differences in the depth of tread... in different flights of stairs in a stairway or stairtower must be minimized." Tread on 2nd step from top on stairs between 2nd and 3rd decks was loose. Repair tread within 1 week.
46 CFR 116.438(g)
Action required: 705 - Other - as specified
Due 16 May 2025
Resolved 13 May 2025
Resolution: Treads secured
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 February 2024
Resolved
"A certificate of Inspection may be suspended and withdrawn or revoked by the cognizant OCMI at any time for noncompliance with the requirements of this subchapter."
46 CFR 115.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2024
Resolution: Completed hull/ISE exam on 14Feb24.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 April 2023
Resolved
Specific construction features for A-class doors: A noncombustible sill or gap equal to the width of the door frame is required beneath doors to prevent fire spread along carpet. Continuous carpeting was found beneath 2 doors: passageway doors into bridal suite and main cabin area. (NVIC 9-97, CH-1; page 41 (50c))
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 September 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2021
Resolved
A vessel of 12 meters or more shall be provided with a whistle. Whistle is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 24 June 2021
Resolved 19 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2021
Resolved
Each child lifejacket must be separated from adult lifejackets. Adult and child lifejackets stowed in same space without divider.
Rectify w/in 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2021
Resolved 28 June 2021
Resolution: Operator provide satisfactory pictures rectifying deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2021
Resolved
Ring Life Buoys must be marker in clearly legible block capital letters with the vessel's name. Two forward ring buoys not labeled with name.
Rectify w/in 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2021
Resolved 28 June 2021
Resolution: Operator provided satisfactory pictures rectifying deficiency
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 June 2021
Resolved
The instructions for a fixed fire extinguishing system must include a schematic diagram of the system. CO2 system pull station missing diagram and labeling.
Rectify w/in 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2021
Resolved 30 June 2021
Resolution: Recieved satisfactory photo of rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2021
Resolved
Each item of lifesaving must be serviceable. Waterlight battery for ring buoy not approved by manufacturer.
Rectify w/in 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2021
Resolved 28 June 2021
Resolution: Operator provided satisfactory pictures rectifying deficiency
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2021
Resolved
Pressure vessels that have a net internal volume of less than 5 cubic feet and do not contain hazardous materials must be stamped with either the ASME "U" or "UM" symbol. Provide proof compressor meets above standard.
Rectify w/in 90 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2021
Resolved 14 September 2021
Resolution: Operatir provided evidence of installation of approved compressor and pressure vessel. 01 requirements cleared, 00 remain outstanding.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 15 May 2019
Resolved
Remote fuel shut-off valve line separated when tested manually. Replace pull cable and perform functional test in the presence of a CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2019
Resolution: Replaced cable, all sat.
Communications › Public Address System › Announcing Station
Issued 17 April 2018
Resolved
Vessel's public address system did not work properly and the Capt&crew were unfamiliar with how to operate, vessel must have a system that works throughout the passenger and crew spaces and Capt/crew must have the proper training on its use.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2018
Resolved 23 April 2018
Resolution: Crew proficient with public address system, all sat.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 April 2018
Resolved
Vessel's emergency lighting below the main deck is not working in spots(galley&outside engine room) leading to the main deck, emergency lighting is required in all passenger and crew spaces below the main deck that will automatically actuated upon loss of normal power and must work continuous for 2 hours
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2018
Resolution: Lighting is installed and correct battery.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 25 March 2016
Resolved
Install ground detection on 208/120 electrical system. Submit plans for approval to CG prior to installation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 27 May 2016
Resolution: Received a tech report from the operator stating that a new ground detection unit was installed and is functioning properly.