Inspection history · 57
22 April 2026
Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8352597
5 March 2024
Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7874593
20 October 2022
COI Inspection · MTSA Verification · Internal Structural Exam · Drydock Exam · Cargo Tank Internal · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7578693
13 November 2020
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7094716
11 July 2019
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6747371
24 May 2019
Administrative Inspection · Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6696308
21 May 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6690487
21 September 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6566706
29 June 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6469124
19 July 2017
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6235337
19 August 2016
Examination of Repairs · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5975243
19 November 2015
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5767536
17 August 2015
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5736207
6 May 2015
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5119215
27 June 2014
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4901232
23 August 2013
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4696831
18 August 2012
MTSA Verification · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4417684
11 August 2011
Hull Examination · Internal Structural Exam · MTSA Verification · COI Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4111151
9 June 2011
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4044581
28 April 2010
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3725974
12 August 2009
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3564941
26 May 2009
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3486417
25 January 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3427474
27 June 2008
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3249526
2 July 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2980880
22 January 2007
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2859991
22 January 2007
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2860057
26 July 2006
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2732499
5 June 2006
COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2670497
22 June 2005
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2399584
14 April 2005
MTSA Verification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2334124
6 May 2004
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2060867
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1984481
21 May 2003
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1796653
1 July 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1639215
13 July 2001
Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1471776
5 April 2001
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1060931
8 February 2001
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1389297
6 February 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 8387
24 January 2000
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1430795
19 February 1999
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1360738
5 May 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 792946
28 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430372
21 March 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1101154
1 March 1996
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 885865
8 February 1996
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 875282
10 December 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 466210
24 February 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 376726
24 February 1995
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 854264
9 March 1994
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 854488
8 March 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 489372
1 March 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 472915
16 December 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 849022
20 May 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431234
22 September 1992
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1244759
30 March 1992
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 459631
20 March 1992
Initial Certification · Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 959434
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 October 2022
Resolved
While fast to a dock, a vessel during transfer of bulk cargo shall display a red flag by day or a red light by night, which signal shall be so placed that it will be visible on all sides. Vessel was not outfitted with a red flag. Operator is required to add a red flag prior to loading cargo.
46CFR151.45-9
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 December 2022
Resolution: Received emailed photos for verification. All Sat
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 20 October 2022
Resolved
When major alterations or major repairs of tank vessels become necessary the work shall be done under the direction of the Officer in Charge, Marine Inspection, and shall be in accordance with the regulations in effect for new construction insofar as possible. When minor alterations or minor repairs of tank vessels become necessary such work shall be under the direction of the Officer in Charge, Marine Inspection, and shall be in accordance with the regulations in effect at the time the vessel was contracted for or built, or in accordance with the regulations in effect for new construction insofar as possible. Bow void STBD knuckle supports and stern void corner supports were damaged. Repair/replace to original condition.
46CFR30.01-10
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 December 2022
Resolution: Received emailed verification of repairs. All Sat
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 20 October 2022
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapors, gases or liquids whose temperature exceeds 150 °F., shall be suitably insulated where necessary to preclude injury to personnel. MI found there was no Insulation on steam lines.
46CFR56.50-1(k)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2023
Resolution: Received verification of new installed insulation. All Sat
14 - Pollution Prevention › 141 - MARPOL Annex I › Hydrostatically balanced loading
Issued 20 October 2022
Resolved
Each loading arm and each transfer pipe system, including each metallic hose, must not leak under static liquid pressure at least 1 1/2 times the maximum allowable working pressure; and F(3) For vessels, annually or as part of the biennial and mid-period inspections. Vessel has not completed the hydrostatic test of cargo line.
33CFR156.170
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2022
Resolution: Received emailed verification of testing. All Sat
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 20 October 2022
Resolved
Vapor-tight marine vessel means a marine vessel with a benzene product tank that has been demonstrated within the preceding 12 months to have no leaks. This demonstration shall be made using Method 21 of part 60, appendix A, during the last 20 percent of loading and during a period when the vessel is being loaded at its maximum loading rate. A reading of greater than 10,000 ppm as methane shall constitute a leak. As an alternative, a marine vessel owner or operator may use the vapor-tightness test described in § 61.304(f) to demonstrate vapor tightness. Vessel is missing Vapor
tightness test letter.
40CFR61.301
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2022
Resolution: Received emailed verification of testing. All Sat
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 11 July 2019
Resolved
Found 10 inch by 1 inch fracture between #2 and #3 wing void. Crop out and renew hull plate, conduct weld NDT to satisfaction of CG marine Inspector prior to cargo operations. 46 CFR 2.01-10
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 11 August 2019
Resolved 16 July 2019
Resolution: crop and renewed plate on sideshell. Conducted NDT on welds, all SAT
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 19 August 2016
Resolved
Flange for vapor connection missing .5" x 1" stud 1" long located at 12 o'clock position. Install stud on vapor connection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 September 2016
Resolved 19 September 2016
Resolution: Received digital picture showing installed stud.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 18 August 2012
Resolved
Port forward tank top scupper plug not operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2012
Resolved 18 August 2012
Resolution: Replaced with new plug.
Construction/Loadline › Structures › Manhole
Issued 18 August 2012
Resolved
Port bow void hatch 2 frozen dog bolts.
Stbd bow void hatch 1 frozen dog bolt.
#1 Port void hatch 2 frozen dog bolts.
#2 Port void hatch 1 frozen dog bolt.
#5 Port void hatch 1 frozen dog bolt.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2012
Resolved 18 August 2012
Resolution: Freed up and lubricated dog bolts.
Construction/Loadline › Structures › Manhole
Issued 18 August 2012
Resolved
Cargo tank hatch #3 has a stipped dog bolt assembly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2012
Resolved 18 August 2012
Resolution: Replaced stripped dog bolt.
Construction/Loadline › Hull › Hull Plating
Issued 9 June 2011
Resolved
Prior to cargo operations vessel must comply with all required hull exams.
Action required: 705 - Other - as specified
Resolved 26 August 2011
Resolution: All required hull exams completed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 5 June 2006
Resolved
After installing cargo pump, conduct a satisfactory hydrostatic test of cargo piping system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2006
Resolution: Hydrostatic test of cargo piping complete, all sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 5 June 2006
Resolved
After installing cargo pump, prove proper operation of cargo emergency shut down.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2006
Resolution: Cargo emergency shut down tested, all sat.
Deck/Cargo
Issued 8 February 2001
Resolved
Conduct annual cargo pipe test as required by 33 CFR 156.170 prior to loading any cargo.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Deck/Cargo
Issued 8 February 1996
Resolved
REMARK THE WORD "VAPOR" ON THE VAPOR HEADER ON THE PORT AND STARBOARD SIDE.THIS ITEM IS TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] THE NEXT CARGO. _x001C_
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Deck/Cargo
Issued 8 February 1996
Resolved
THE "ERL" SPILL VALVES HAVE DEFECTIVE GASKETS ON THE VALVE DISCS. REPLACE ALL DEFECTIVE GASKETS TO THE SATIFACTION OF THE COGNIZANT [name withheld] THE NEXT CARGO.
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Construction/Loadline
Issued 9 March 1994
Resolved
Make repairs to #13 from bow tanktop vertical frame & vertical stiffener aft of #13 Frame on stbd side.
Condition: Unknown
Due 9 March 1994
Resolved 9 March 1994