Records from 1992 to 2011. Most recent: operational control imposed, 12 September 2011.
Inspection history · 40
12 September 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4142700
10 September 2011
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4134473
6 January 2009
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3389264
3 December 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3373368
3 December 2008
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3373892
10 June 2008
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3233060
9 May 2008
PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3202000
11 October 2007
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3077430
13 September 2007
Loadline Exam · NPV Safety Exam · Annual Inspection · ILO-147 Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3056479
19 July 2007
Type not recorded
No type recorded · USCGC SPENCER (WMEC 905) · Activity 3073201
21 June 2007
NPV Safety Exam · ILO-147 Exam · Loadline Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2968834
23 May 2007
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2938029
3 May 2007
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2921187
30 April 2007
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2919221
30 April 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2919321
28 April 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2917961
22 February 2007
Random ISPS/MTSA/PSC
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2875937
5 January 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2850517
15 September 2006
MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2779043
16 June 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1819111
7 April 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1769633
1 November 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1699731
16 September 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1676437
9 May 2002
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1615067
24 March 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 428968
1 December 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 423228
30 October 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 422186
2 June 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 417072
27 December 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 411202
16 May 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 403677
17 August 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 394160
17 May 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 391170
5 May 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 377885
2 February 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 504087
5 May 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 366545
14 October 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 489397
15 July 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 492327
16 April 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 667888
9 March 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 356821
8 September 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 459636
Engineering › Compressed Air System (start air) › Compressor
Issued 3 December 2008
Resolved
1 of the 2 main engine air compressors inoperable. DNV opened a condition of class to be repaired by 12-30-08.
Action required: 705 - Other - as specified
Due 30 December 2008
Resolved 6 January 2009
Resolution: Received Survey Report from class attesting to the repair of the air compressor.
Fire Fighting › Combustible Materials › Insulation
Issued 11 October 2007
Resolved
OIL SOAKED LAGGING ON PORT SIDE OF MAIN ENGINE BELOW CAMSHAFT CREATES A FIRE HAZARD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2007
Resolution: AFTER REISSUING DEFICANCY THE SHIP CREW REMOVED ALL OLD OIL SOAKED LAGGING AND REPLACED IT WITH NEW LAGGING ON THE ENGINE.
Engineering › Fuel Oil Service System › Heater
Issued 13 September 2007
Resolved
OIL LEAKS IN THE PURIFIER ROOM COMING FROM THE MAIN ENGINE FUEL OIL HEATER AND THE NUMBER 1 AND NUMBER 2 FUEL OIL SUPPLY PUMPS: CREATING A FIRE HAZARD.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 October 2007
Fire Fighting › Combustible Materials › Insulation
Issued 13 September 2007
Resolved
OIL SOAKED LAGGING IN PURIFIER ROOM CREATES FIRE HAZARD
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 October 2007
Resolution: replaced with new shielding.
Fire Fighting › Combustible Materials › Insulation
Issued 13 September 2007
Resolved
OIL SOAKED LAGGING ON PORT SIDE OF MAIN ENGINE BELOW CAMSHAFT CREATES A FIRE HAZARD.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 October 2007
Resolution: reissued deficiency to correct prior to leaving port. see activity 3077430
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 September 2007
Resolved
2 INCH CRACK IN TRANVERSE BULKHEAD IN STEERING GEAR ROOM LOCATED ALONG PORTSIDE NEAR THE OUTERSHELL JUST AFT OF PORT SIDE ENTRANCE TO STEERING ROOM.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 October 2007
Resolution: recieved class report that crack was replaced.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 3 May 2007
Resolved
MF/HF/DSC not operating. Prior to next U.S. port vessel is required to submit Class report attesting to repairs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 10 May 2007
Resolution: Repairs completed as per DNV surveyor
Communications › Radio Communications › VHF Radiotelephone
Issued 30 April 2007
Resolved
MF/HF Radio inoperable. Parts available at next US port (Sector Hampton Roads). Provide tech report to Sector Hampton Roads upon completion of repairs/replacement. SOLAS 74/78 amended (2004 edition) Ch. IV
Action required: 705 - Other - as specified
Resolved 10 May 2007
Resolution: Satisfactory repair of radio and new battery charger installed as per technician report.
Construction/Loadline › Markings
Issued 9 May 2002
Resolved
Paint Loadline in a contrasting color to the hull prior to 09June02. ILLC 66 AnnexI/8 LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2002
Resolved 9 May 2002
Resolution: corrected by class
Construction/Loadline › Hull
Issued 9 May 2002
Resolved
Have classification society attest to the structural soundness of the deep inset in excess of one inch per linear foot, starboard side foward of the aft draft markings prior to departing the port. ILLC 66 Annex I/1 LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 May 2002
Resolved 9 May 2002
Resolution: corrected by class
Fire Fighting › Fire Main
Issued 9 May 2002
Resolved
Fire and ballast pump overboard discharge line, starboard side aft engine room is wasted and holed leaking a steady stream of sea water into the bilge (approx 2-3 gpm). Repair to the satisfaction of class prior to departing the port. SOLAS 74 (Amended) I/11 LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 9 May 2002
Resolved 9 May 2002
Resolution: corrected by class
Electrical › Electrical Distribution System (service)
Issued 9 May 2002
Resolved
Provide electrical safety matting in front of switch board in the fuel oil purifier room prior to 9June02. SOLAS 74 (Amended) II-1/45.1 LEGACY COMPONENT DESC: Non-conducting Deck Covering
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2002
Resolved 9 May 2002
Resolution: corrected by class
Lifesaving
Issued 30 October 1998
Resolved
Ensure that the EPIRB is able to float free, prior to next U.S. port from over seas. SOLAS 74 amended IV reg 7.6.4
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Unknown
Issued 17 May 1996
Resolved
PROVE PROPER OPERATION OF INCINERATOR (LOSS OF FLAME SENSOR). PRIOR TO ENTRY TO NEXT US PORT.
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997