OSPREY

OSPREY is a 1993 industrial vessel. The Coast Guard has recorded 95 inspections since 1993, most recently in May 2026, along with 77 deficiencies and 5 casualty investigations between 2010 and 2026.

Records from 1993 to 2026. Most recent: inspection, 8 May 2026.

Built
1993
Last inspected
8 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9044657 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDQ6663
372548
Flag
UNITED STATES
369229000
Maury page id
psix-372548

Inspections, by type

…with no type recorded29
Years with a record 31 calendar years (1993–2026)
The 95 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)191.8 ft × 45.0 ft × 17.0 ft
Registered tonnagegross 498 / net 339
ITC dimensions (L × B × D)191.8 ft × 45.0 ft × 17.0 ft
ITC tonnagegross 1,322 / net 396
BuilderBENDER SHPBDLDG & REPAIR · MOBILE, AL, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFORT JACKSON, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 15 December 2025 · expires 31 December 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it396 - Convention (Subpart B), Net Ton
339 - Regulatory (Subpart C or D), Net Ton
1322 - Convention (Subpart B), Gross Ton
498 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ6663MMSI 369229000 · active · compulsorily equipped · granted 4 December 2025, expires 4 December 2035
WBO8576MMSI 366592000 · cancelled · compulsorily equipped · granted 16 October 2017, cancelled 30 September 2025
EX109MMSI 366592000 · expired · exemption · granted 3 December 2009, cancelled 4 January 2014
EX71MMSI 366592000 · expired · exemption · granted 29 November 2004, cancelled 5 December 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MSRC 8-1 Oil Recovery · MISLE 380401 · 16 January 2019 · activity 6611720BRANCH PILOT Passenger (Uninspected) · MISLE 390587 · 16 January 2019 · activity 6611720UM ELHANAYA Freight Ship · MISLE 1110091 · 4 March 2014 · activity 4810029

Inspection history · 95

8 May 2026 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8372771
3 April 2026 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8341655
30 September 2025 COI Inspection · Administrative Inspection · MARPOL Annex I Examination · Deficiency Check · MARPOL Annex V Examination · MARPOL Annex VI Survey · MARPOL Annex II Examination · MARPOL Annex IV Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8270721
16 July 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8170024
2 December 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8041807
20 March 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7882670
25 January 2024 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7843018
1 December 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7832056
26 January 2023 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7611775
29 September 2022 Administrative Inspection · Drydock Exam · Deficiency Check · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7568884
6 July 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7498310
30 November 2021 MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7359578
23 November 2020 COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7100496
16 October 2020 Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7078593
16 September 2020 Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7059138
30 January 2020 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6876144
31 January 2019 Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6605107
16 January 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6611720
3 January 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6331882
18 August 2017 Examination of Repairs · Hull Examination · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6244705
26 January 2017 Examination of Repairs · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6075289
13 July 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5939503
28 January 2016 Cargo Tank Internal · Drydock Exam · Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5802836
4 March 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4810029
17 February 2011 MTSA Verification · DAPI Audit · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3928556
6 January 2011 Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3914203
9 December 2010 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3903811
5 September 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3905616
28 January 2010 MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3660421
5 February 2009 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3392804
21 February 2008 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3151319
23 January 2008 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3135032
13 February 2007 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2871352
7 February 2007 Cargo Tank Internal · Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2868311
15 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2649530
23 February 2006 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2590445
2 February 2006 Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2577907
26 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2574054
3 November 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2527862
9 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2352877
3 February 2005 MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2285986
13 April 2004 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2043528
4 March 2004 Periodic Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2017803
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1980795
24 May 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1811208
21 January 2003 Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1732854
4 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1687817
7 March 2002 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1491859
17 April 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1062649
8 March 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1437861
8 September 2000 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1373157
19 May 2000 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1049607
16 May 2000 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 818465
23 March 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440267
19 September 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 84010
20 May 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 800693
11 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 200927
11 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 768124
11 March 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1384071
10 April 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 788975
18 March 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396882
8 March 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 769691
5 March 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 14162
5 March 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 200921
10 February 1998 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1383772
22 October 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 10349
13 March 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413130
15 January 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 763262
13 December 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 200925
11 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758636
10 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 200920
4 April 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1416273
21 March 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442372
14 August 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758212
7 August 1995 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1380271
27 July 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 200928
27 June 1995 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442273
16 March 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435602
2 February 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 684023
31 January 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 25032
7 July 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1173046
31 May 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1171329
17 May 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 684017
10 May 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 40932
14 April 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398068
8 April 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 13501
8 April 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 161027
6 April 1994 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1016426
24 March 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1165738
20 September 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 684010
22 July 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 6138
2 July 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 847040
19 April 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 844282
31 March 1993 Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1147781
12 March 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 99214

Deficiency record · 77

01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 26 February 2026 Resolved
On vessels subject to STCW the licensed engineer must hold an endorsement as officer in charge of an engineering watch. Individual serving as licensed engineer did not have required endorsement on MMC.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2026
Resolution: Reviewed crew MMCs, corrected
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 February 2026 Resolved
Each vessel must carry on each side of the vessel, life rafts with an aggregate capacity sufficient to accommodate 150 percent of the total number of persons on board. Life rafts were not installed on the vessel.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 March 2026
Resolution: After the vessel departed. Received photos of the rafts with current service stations stickers and arrangements.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 26 February 2026 Resolved
All vessels must carry adequate and up-to-date charts. Vessels ECDIS system was not fully installed at the time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2026
Resolution: Verified Function of the charts
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 26 February 2026 Resolved
Each vessel must carry an auxiliary line that is at least 450 meters (1,500 feet) long for the line-throwing appliance.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2026
Resolution: Verified presense of auxilliary line
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 26 February 2026 Resolved
Each fireman's outfit must consist of one flame safety lamp. In lieu of the flame safety lamp, vessels may carry an oxygen depletion meter. Fireman outfits did not have flame safety lamps.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2026
Resolution: Vessel obtained oxygen depletion meters.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 February 2026 Resolved
A lockout valve must be provided on any carbon dioxide extinguishing system protecting a space over 6,000 cubic feet in volume and installed or altered after July 9, 2013. Altered means modified or refurbished beyond the maintenance required by the manufacturer's design, installation, operation and maintenance manual. The CO2 system on board had been altered when the helideck was removed and no lockout valve was installed. 46 CFR 95.15-50
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2026
Resolution: Verified lockout installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 February 2026 Resolved
Each carbon dioxide extinguishing system installed or altered after July 9, 2013, must have an approved odorizing unit to produce the scent of wintergreen. The CO2 system on board had been altered when the helideck was removed and no odorizer was installed. 46 CFR 95.15-60
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2026
Resolution: Oderizor installed
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 26 February 2026 Resolved
Each daylight signaling lamp should be provided with at least three spare illuminants complying with the type-tested illuminant. Daylight Signal lamp did not have spare bulbs. SOLAS (20) CH.V 19.2.2.2 MSC (95).72
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2026
Resolution: Verified new bulbs
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 February 2026 Resolved
Spaces protected by carbon dioxide must be conspicuously marked as follows CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING. Signage does not include mention of wintergreen. 46 CFR 97.37-11(b)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2026
Resolution: Verified Signage in place
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2026 Resolved
An emergency bilge suction must be provided in the machinery space for all self-propelled vessels. Vessel’s emergency bilge suction was inoperable at the time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2026
Resolution: verified bilge suction function
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2026 Resolved
Oil strainers and other equipment subject to normal leakage must be fitted with drip pans. Fuel oil strainers in the engine room did have drip pans.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2026
Resolution: Drip pans installed
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 26 February 2026 Resolved
Plans are required to show the location of fire-fighting equipment and general arrangement of the vessel. Fire control plan unapproved, walk fire control plan with marine inspector and stamp for approval.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2026
Resolution: Fire control plan verified and stamped
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 February 2026 Resolved
At least two lifebuoys, each with attached selfactivating smoke signals, must be stowed where they can be quickly released from the navigating bridge and should, when released, fall directly into the water without striking any part of the vessel. Vessel did not have bridge buoys installed.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2026
Resolution: Bridge bouys installed and function tested.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 26 February 2026 Resolved
A stability booklet must be prepared for each vessel which information needed for safe operation is not available on the COI or stability letter. Stability book and calculations need to be completed and issued to the vessel following helo deck removal.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2026
Resolution: Stability book updated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2026 Resolved
It is the duty of the Chief Engineer when assuming charge of machinery of a vessel to examine thoroughly if any items are bad they shall be reported to the Master. The fuel line on the #3 generator leaking oil.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2026
Resolution: Fuel leak repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 26 February 2026 Resolved
Each immersion suit must be designed so that a light meeting the requirements of subpart 161.012 of this chapter can be attached to its front shoulder area. Vessel’s immersion suits did not have attached lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2026
Resolution: Immersion suits equiped with lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2026 Resolved
The steering gear components must be of sound and reliable construction. The Port rudder post packing did not have double nut to prevent loosening of seal packing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2026
Resolution: Double nut installed on rudder post.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 January 2024 Resolved
Appliances to ensure watertight integrity including watertight doors must meet the structural standards of the American Bureau of Shipping's Rules for Building and Classing Offshore Mobile Drilling Units, 1978. Grease fittings on several watertight door appliances were found to be painted over. Properly service grease fittings on watertight doors. 46 CFR 108.113
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2024
Resolved 19 February 2024
Resolution: Received ABS report attesting to correction.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 January 2024 Resolved
All marine engineering details, such as boilers, pressure-vessels, main and auxiliary machinery, piping, valves, and fittings, shall be designed, constructed, and installed in accordance with the provisions of this sub-chapter. Multiple butterfly valves in engineering spaces were found with broken valve handles. Replace broken valve handles. 46 CFR 50.01-10(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2024
Resolved 19 February 2024
Resolution: Received ABS report attesting to correction.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 25 January 2024 Resolved
On vessels required by § 112.05–5(a) to have a temporary emergency power source, emergency lighting of at least one light is required in each space where a person may be maintaining, repairing, or operating equipment. Two emergency lights were found inoperable in engineering spaces. Repair to provide proper operation. 46 CFR 112.15-1(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2024
Resolved 19 February 2024
Resolution: Received ABS report attesting to correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 December 2023 Resolved
Vessel is leaking hydraulic fluid through bow thruster seal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2023
Resolved 19 December 2023
Resolution: Observed previously "cleared" 835 from another USCG unit.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 February 2018 Resolved
Port & starboard emergency escape routes from the engine room lacked lighting atop the ladder/stairs for proper egress.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 27 February 2018
Resolution: Battle lanterns installed at the top of the escape routes.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 February 2018 Resolved
ECDIS found to be powered via a portable extension cord rather than by a permanent wiring installation.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 27 February 2018
Resolution: Power outlet permanently installed near ECDIS so manufacturer's electric cord length would suffice.
Stability › Watertight Integrity › General
Issued 26 January 2017 Resolved
MI's noted that the WTD self closing device on the Engineroom and B/T compartment were not shutting automatically as designed. Crew Adjused and corrected while MI's were on board.
Action required: 705 - Other - as specified
Due 30 January 2017
Resolved 26 January 2017
Resolution: Crew Adjused and corrected while MI's were on board.
Engineering › Steering Gear System › Motor
Issued 26 January 2017 Resolved
Attending MI's noted that the hydraulic oil fill cap on the Steering gear hydraulic motor resivours were missing the hardware allowing for debris to enter the resivour.
Action required: 705 - Other - as specified
Due 30 January 2017
Resolved 26 January 2017
Resolution: Crew replaced missing hardware while MI's were on board the vessel.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 26 January 2017 Resolved
MI's noted that the heat detector located on the STBD side steering compartment was painted over.
Action required: 705 - Other - as specified
Due 30 January 2017
Resolved 26 January 2017
Resolution: Crew replaced the detector with a new onboard spare and demonstrated a satisfactroy test of syetem.
Communications › Alarms/Indicators › General Alarm
Issued 26 January 2017 Resolved
During the test of fire and general alarms it was noted that the main call bell located in the engineroom was inoperable.
Due 30 January 2017
Resolved 26 January 2017
Resolution: Crew disassembled the bell and effected repairs and demonstrated proper operation of the bell prior to the departure of the attending MI's.
Engineering › Compressed Air System (control) › Fitting
Issued 28 January 2016 Resolved
All 3 air receivers have a MAWP of 300psi, gauges only go up to 300 psi. Replace gauges witin range of 1.2-2 times the setting of the relief valve.
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 3 February 2016
Resolution: Deficiency was corrected to the staisfaction of the marine inspector.
Lifesaving › Rescue Boat Equipment › Thermal Protective Aid
Issued 28 January 2016 Resolved
Rescue boat is missing 02 thermal protective aids. ensure required equipment is onboard vessel.
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 3 February 2016
Resolution: Deficiency was corrected to the staisfaction of the marine inspector.
Engineering › Fuel Oil Service System › Hose
Issued 17 February 2011 Resolved
Replace the 6 flexible fuel hoses as marked with hoses meeting the SAE J-1942 Standard.
Action required: 705 - Other - as specified
Due 17 March 2011
Resolved 21 February 2011
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 23 February 2006 Resolved
Post steering gear and emergency broadcast placard.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2006
Resolved 24 February 2006
Resolution: Provided and posted placards.
Communications › Internal Communications System › Sound-powered Telephone
Issued 23 February 2006 Resolved
Repair communications on bridge sound powered phone prior to sailing
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2006
Resolved 24 February 2006
Resolution: Repaired sound powered phone.
Communications › Radio Communications › EPIRB
Issued 23 February 2006 Resolved
Renew EPIRB antenna prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2006
Resolved 24 February 2006
Resolution: Renewed antenna.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 23 February 2006 Resolved
Provide spare life boat radio batteries (2) prior to plan.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2006
Resolved 24 February 2006
Resolution: Provided spare batteries.
Communications
Issued 4 March 2004 Resolved
Prove proper operation of SSB radio.
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 13 April 2004
Resolution: New tuner installed and performed radio test, sat.
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 March 2004 Resolved
Replace expired contents of bridge first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 13 April 2004
Resolution: New contents acquired and in bridge first aid kit.
Navigation › Collision/Grounding Avoidance
Issued 4 March 2004 Resolved
Prove operation of ARPA. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 13 April 2004
Resolution: Operational test performed, sat.
Accommodation/Occupational Safety › Occupational Safety
Issued 4 March 2004 Resolved
Make operable water fountain on bridge. LEGACY COMPONENT DESC: Water Fountain
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 4 March 2004
Resolution: Cleared on spot.
Engineering › Fuel Oil Storage/Transfer System
Issued 4 March 2004 Resolved
Ensure all F/O and L/O vent flame screens are flush. LEGACY COMPONENT DESC: Vent Pipe
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 13 April 2004
Resolution: All vent flame screens are mounted flush.
Engineering › Bilge Water Management System
Issued 4 March 2004 Resolved
Prove operation of bilge alarms in bow thruster room (No. 9 and No. 10) on alarm panel. LEGACY COMPONENT DESC: Alarms
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 13 April 2004
Resolution: Circuit card changed out and bilge alarms in bow thruster room (No. 9 and No. 10) tested sat.
Electrical › Electrical Distribution System (service)
Issued 4 March 2004 Resolved
Refasten electric cable to port aft crane. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 13 April 2004
Resolution: New fasteners installed.
Fire Fighting › Combustible Materials
Issued 4 March 2004 Resolved
Remove excess oily waste from engineering space bilges. LEGACY COMPONENT DESC: Oily Water
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 13 April 2004
Resolution: Oily waste removed.
Engineering › Diesel Engine (propulsion-electric)
Issued 4 March 2004 Resolved
Stbd MDE F/O filter inlet flex hose is in excess of 30 inches. LEGACY COMPONENT DESC: Fuel Hose
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 13 April 2004
Resolution: Hard pipe extended and 12" hose installed.
Documentation › Logs/Records › Oil Record Book
Issued 4 March 2004 Resolved
Properly maintain Oil Record Book Part I.
Action required: 705 - Other - as specified
Due 4 March 2004
Resolved 4 March 2004
Resolution: Resolved on the spot.
Electrical › Electrical Distribution System (service)
Issued 4 March 2004 Resolved
Make electrical connectors gas tight in port fwd disc oil valve.
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 13 April 2004
Resolution: New fittings installed and electrical connectors are now gas tight.
Electrical › Electrical Distribution System (service)
Issued 4 March 2004 Resolved
Make electrical connections safe, cable entry port crane aft.
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 13 April 2004
Resolution: Electrical wire and fittings renewed.
Electrical › Electrical Distribution System (service)
Issued 4 March 2004 Resolved
Make electrically safe or gas tight intrusion alarm panel main deck aft and place all splice cables in electrical junction boxes.
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 13 April 2004
Resolution: Intrusion alarm panel has been disconnected from vessel''s power and an electrically safe power outlet has been installed on upper deck, linked to shore power only. See diagram.
Documentation › Certificates/Documents
Issued 4 March 2004 Resolved
Provide copy of Safety Radiotelephony Certificate. LEGACY COMPONENT DESC: Safety Radiotelephony Cert
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 13 April 2004
Resolution: New certificate provided.
Lifesaving
Issued 8 March 2001 Resolved
CALIBRATE H2S MONITORING SYSTEM.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Construction/Loadline
Issued 8 March 2001 Resolved
REPAIR SELF CLOSING DOOR HINGE TO COMMAND AND CONTROL CENTER DOOR.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Electrical
Issued 8 March 2001 Resolved
INSTALL EMERGENCY LIGHTS AT BOTH EMBARKATION STATIONS ON MAIN DECK.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Electrical
Issued 8 March 2001 Resolved
INSTALL BLANKS IN CIRCUIT BREAKER PANEL LP-204 BY GALLEY.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Documentation
Issued 11 March 1999 Resolved
PROVIDE CURRENT SAFETY RADIO TELEPHONY CERTIFICATE AND VESSEL BRIDGE TO BRIDGE RADIO TELEPHONY CERTIFICATE; OR PROVIDE PROOF OF FCC EXTENSION ON CURRENT CERTIFICATES.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Lifesaving
Issued 11 March 1999 Resolved
PROVE PROPER OPERATION OF STBD SIDE CRANE USED FOR RESCUE BOAT.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Engineering
Issued 11 March 1999 Resolved
PROVE PROPER OPERATION OF ALL OILY WATER SEPARATORS. IOPP WILL BE ENDORSEDAT THAT TIME.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Fire Fighting
Issued 11 March 1999 Resolved
PROVIDE LIFELINES FOR FIREMENS OUTFITS.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Lifesaving
Issued 11 March 1999 Resolved
PROVIDE SPECIFICATIONS FOR EXISTING WORKBOATS (RESCUE BOATS) FROM US MARINE- INCLUDE: MAX PERSONS CAPACITY, WEIGHT, LENGTH AND BEAM. VESSEL IS TO PROVIDE SPECS OR PROVIDE SUITABLE RECSUE BOAT. PROVIDE MARKINGS AND RETRO AS REQUIRED.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Lifesaving
Issued 18 March 1998 Resolved
REPLACE OR REPAIR ALL FLIGHT DECK NETS.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Engineering
Issued 18 March 1998 Resolved
MAKE CORRECTIONS TO VESSELS DIAGRAM IN OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 18 April 1998
Resolved 20 March 1998
Fire Fighting
Issued 18 March 1998 Resolved
PROVIDE HYDROSTATIC TEST FOR ALL THREE SEMI PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 18 April 1998
Resolved 20 March 1998
Engineering
Issued 18 March 1998 Resolved
PROPERLY LABEL ALL FUEL VENTS AND ASSOCIATED MANIFOLD VALVES IAW PLANS.
Condition: Unknown
Due 18 April 1998
Resolved 20 March 1998
Electrical
Issued 18 March 1998 Resolved
LABEL ALL PANELBOARDS AS PER 46 CFR 111.40-11.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Electrical
Issued 18 March 1998 Resolved
REPLACE OR PROVE FLEXIBLE ELECTRICAL CORD ON 3 EA. SSDG JACKET WATER HEATERS MEET 46 CFR 111.60-13.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 18 March 1998 Resolved
LABEL ALL LIFE PRESERVER AND EMMERSION SUIT STOWAGE LOCATIONS.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Electrical
Issued 18 March 1998 Resolved
REPAIR EMERGENCY LIGHTING IN BOW THRUSTER COMPARTMENT BY MSD TANK.
Condition: Unknown
Due 18 April 1998
Resolved 20 March 1998
Fire Fighting
Issued 13 March 1997 Resolved
REPLACE GLASS IN CENTER WATERTIGHT DOOR IN AFT BULKHEAD ON THE 01 DECK WITHA60 GLASS.
Condition: Unknown
Due 27 March 1997
Resolved 25 August 1997
Deck/Cargo
Issued 13 March 1997 Resolved
HYDRO ALL CARGO PIPING.
Condition: Unknown
Due 27 March 1997
Resolved 25 August 1997
Electrical
Issued 13 March 1997 Resolved
REWIRE SECURITY SYSTEM SO THAT IT IS POWERED BY THE SHORE POWER.
Condition: Unknown
Due 27 March 1997
Resolved 25 August 1997
Electrical
Issued 13 March 1997 Resolved
PROPERLY REWIRE SECURITY SENSORS SO THAT TONAGE DOORS CAN BE OPERATED PROPERLY.
Condition: Unknown
Due 27 March 1997
Resolved 25 August 1997
Fire Fighting
Issued 13 March 1997 Resolved
PROVE PROPER OPERATION OF TIME DELAY ON ENGINE ROOM, OIL SEPERATOR AND OIL HEATER CO2 SYSTEMS.
Condition: Unknown
Due 20 March 1997
Resolved 21 March 1997
Lifesaving
Issued 21 March 1996 Resolved
PROVIDE LINE THROWING APPARATUS WITH PROPER NUMBER OF PROJECTILES.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Construction/Loadline
Issued 21 March 1996 Resolved
PROVE PROPER OPERATION OF FOREPEAK REACH ROD/VALVE.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Lifesaving
Issued 31 March 1993 Resolved
DEMONSTRATE PROPER OPERATION OF DAVIT CONTROLS FOR VESSELS RESCUE BOAT DAVIT ASSEMBLY, STOP ALL HYDRAULIC OIL LEAKS AT THE CONTROL STATION OR PROVIDE FIXED CONTAINMENT.
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Navigation
Issued 31 March 1993 Resolved
PROVIDE ONBOARD VESSEL A HAND LEAD BY 30APR93
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Electrical
Issued 31 March 1993 Resolved
PROVIDE EMERGENCY LIGHTS (4EA) WITH GLOBE GUARDS IN THE OILY WATER SEPERATOR RM AND PIPE TUNNEL PASSAGEWAY BY 30 APR 93
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Deck/Cargo
Issued 31 March 1993 Resolved
PROVIDE THE COAST GUARD WITH APPROVAL OR PROVE EQUIVALANCY OF THE TRANSREC 350 FOR HAZARDOUS LOCATION OPERATIONS PRIOR TO PLACING THE UNIT IN OPERATION, BUT NOT LATER THAN 31SEP93.
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Electrical
Issued 31 March 1993 Resolved
PROVIDE THE COAST GUARD WITH APPROVAL OR PROVE EQUIVALANCY OF THE ACS OILY WATER SEPERATOR'S "SQUARE D" CIRCUIT BREAKER (CLASS 8539). UNIT TO MEET REQUIREMENTS OF 46CFR111.105-7(A)OR(B), AND 111.105-9(A)&(B), PRIOR TO PLACING UNIT IN OPERATION, BUT NOT LATER THAN 30SEP93.
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993

Casualty record · 5

1 June 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3775394
5 September 2010Routine · role: Involved in a Marine Casualty · activity 3905616
4 March 2014Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4810029
16 January 2019Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6611720
8 May 2026Routine · role: Involved in a Marine Casualty · activity 8372771
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

LOUISIANA RESPONDER (2010–2019). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.