FALCON

FALCON is a 1993 industrial vessel. The Coast Guard has recorded 85 inspections since 1993, most recently in April 2026, along with 92 deficiencies — 2 with no resolution recorded —, 1 operational control and 3 casualty investigations between 2006 and 2009.

Records from 1993 to 2026. Most recent: inspection, 7 April 2026.

Built
1993
Last inspected
7 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9044671 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDQ6686
372550
Flag
UNITED STATES
369237000
Maury page id
psix-372550

Inspections, by type

…with no type recorded14
…past their stated due date2
Years with a record 30 calendar years (1993–2026)
The 85 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)191.8 ft × 45.0 ft × 17.0 ft
Registered tonnagegross 498 / net 339
ITC dimensions (L × B × D)191.8 ft × 45.0 ft × 17.0 ft
ITC tonnagegross 1,322 / net 396
BuilderBENDER SHIPBUILDING · MOBILE, AL, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPASCAGOULA, MS
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 15 December 2025 · expires 31 December 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it339 - Regulatory (Subpart C or D), Net Ton
396 - Convention (Subpart B), Net Ton
498 - Regulatory (Subpart C or D), Gross Ton
1322 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ6686MMSI 369237000 · active · compulsorily equipped · granted 4 December 2025, expires 4 December 2035
WBO8584MMSI 366601000 · cancelled · compulsorily equipped · granted 18 October 2017, cancelled 19 November 2025
EX123MMSI 366601000 · expired · exemption · granted 15 December 2009, cancelled 4 January 2014
EX57MMSI 366601000 · expired · exemption · granted 29 November 2004, cancelled 5 December 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

THEOFYLAKTOS Freight Ship · MISLE 419313 · 21 April 2006 · activity 2634077

Inspection history · 85

7 April 2026 MARPOL Annex I Examination · MARPOL Annex VI Survey · MARPOL Annex IV Survey · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8332393
7 April 2026 Cargo Tank Internal · Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8332657
29 January 2026 COI Inspection · MARPOL Annex II Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex IV Survey · Administrative Inspection · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8299774
11 April 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8110127
22 November 2024 Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8038559
13 May 2024 Periodic Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7911451
19 July 2023 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7751266
21 April 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7668176
6 July 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7498813
5 May 2022 Administrative Inspection · MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7444144
26 February 2021 MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7146092
11 February 2021 Administrative Inspection · Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7150831
7 May 2020 Annual Inspection · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6949782
5 April 2019 Administrative Inspection · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6656362
9 August 2018 Hull Examination · Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6506075
6 March 2018 Annual Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6366874
20 February 2018 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6358263
26 April 2017 Administrative Inspection · Annual Inspection · MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6133300
21 April 2016 MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5859297
4 March 2016 COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5827119
24 February 2016 Underwater Inspection in lieu of Drydock · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5820921
15 October 2014 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5005768
20 June 2014 Administrative Inspection · MTSA Verification · MARPOL Annex I Examination · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4893975
15 December 2010 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3911916
20 January 2009 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3398409
28 October 2008 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3353000
21 July 2008 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3276736
17 June 2008 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3239412
22 May 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3196573
7 June 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2953132
10 May 2007 Annual Inspection · MARPOL Annex V Examination · Ballast Water Examination · MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2911952
5 March 2007 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2882136
13 February 2007 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2871302
26 May 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2659803
15 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2649528
22 April 2006 Examination of Repairs · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2645492
21 April 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2634077
8 March 2006 Hull Examination · Administrative Inspection · Internal Structural Exam · Underwater Inspection in lieu of Drydock · Ballast Water Examination · COI Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2599574
26 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2574053
3 November 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2527839
7 October 2005 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2510217
24 August 2005 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2473431
8 August 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2455766
11 July 2005 Annual Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2423179
9 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2352873
25 August 2004 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2175910
8 July 2004 Periodic Inspection · MTSA Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2125753
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1980792
18 August 2003 In-Service Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1876324
8 August 2003 Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1880047
8 January 2003 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1728410
13 August 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1661233
8 July 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1643681
5 July 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1067432
5 June 2001 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1473106
16 May 2001 Excursion Permit
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1068414
11 May 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1429551
27 July 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393490
10 March 2000 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 815999
18 January 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 814048
20 October 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1378853
4 August 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 148597
1 July 1999 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1449204
4 November 1998 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 805068
9 July 1998 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1426099
9 July 1997 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1439900
9 October 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 841871
16 July 1996 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1407725
23 April 1996 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1080591
17 April 1996 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1388001
30 October 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 833966
19 September 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1183199
11 July 1995 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1432926
10 May 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1192363
7 December 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1377272
27 July 1994 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1173024
20 July 1994 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1414341
26 April 1994 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1387596
6 April 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 856731
29 March 1994 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 856662
6 December 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1146071
18 October 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 684014
15 October 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 39522
18 August 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 844990
19 July 1993 Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1157630

Deficiency record · 92

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 5 May 2026 No resolution recorded
The Safety Management Certificate should be issued to a ship for a period which should not exceed five years by the Administration or an organization recognized by the Administration. Vessel does not hold a valid SMC. Vessel restricted from international voyages.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 5 May 2026 Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval covering the proposed work except as modified by § 91.45-1. The fire and safety plan require updates to capture route and service changes. Submit plans to OCMI for onboard verification.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 11 May 2026
Resolution: Chief mate brought plans by the office for MI review and stamping. All required changes were made iaw previous inspection and guidance.
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 5 May 2026 Resolved
Systems and equipment, including associated back-up arrangements perform the functional requirements of regulations 19 and 20 shall conform to appropriate performance standards... The daylight signaling lamp needs three total spare bulbs, only had one on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 20 May 2026
Resolution: Received photographic evidence of the daylight signal lamp bulbs receipt on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 May 2026 Resolved
Table 1 to § 95.50-10(b) indicates the minimum required number and type of extinguisher for each space listed. A portable 40-B extinguisher is not installed in the vicinity of the paint locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 20 May 2026
Resolution: Received photographic evidence of the 40:B extinguisher appropriately mounted near the paint locker.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 5 May 2026 No resolution recorded
Public Address System: There must be a sufficient number of loudspeakers throughout the vessel. The public address system does not sound in the crew accommodation area.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 April 2026 Resolved
The master or person in charge of a vessel that is required by 46 U.S.C. 11301 to have an official logbook shall maintain the logbook on form CG-706. The vessel seeks certification for International voyages and does not possess an official logbook. A consistent and complete record for domestic voyages and maintenance was not provided during the inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Vessel acquired official logbooks, and standardized a digital unofficial logbook and provided consistent entries.
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 22 April 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Radio logbook was acquired and started; GMDSS suite UPS batteries were replaced and passed a darkship test; Station license was updated with Sat C #; new placards were provided near radios.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 22 April 2026 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. The Master and one AB have expired STCW medical certificates, and the same AB is without an STCW endorsement for his position.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Master was replaced, and the AB was supplemented with another licensed individual.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 22 April 2026 Resolved
Vessels equipped with ballast water tanks that operates in the waters of the United States must maintain a ballast water management (BWM) plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's BWM strategy. The vessel does not have an updated BWM plan for the intended service and operations.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: BWMP was amended to show the specific operational strategy for the vessel.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 22 April 2026 Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel was missing EAP information and updated DAPI consortium information.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: EAP information was posted in the crew mess.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Designated person(s)
Issued 22 April 2026 Resolved
To ensure the safe operation of each ship and to provide a link between the company and those onboard, every company, as appropriate, should designate a person or persons ashore having direct access to the highest level of management. DPA contact information was not available on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Company contact info was posted in crew mess.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 22 April 2026 Resolved
The Safety Management Certificate should be issued to a ship for a period which should not exceed five years by the Administration or an organization recognized by the Administration. Vessel does not hold a valid SMC.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2026
Resolution: Vessel was not able to accomplish SMC issuance. Has audit scheduled for future port of call in Florida. 835 reissued with 30-day timeframe and route limitation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 April 2026 Resolved
Each crew berthing area shall be equipped with information regarding vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage. SASH posters are missing company policies. 46 USC 11101(a)(5)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: SASH posters updated with company specific policy.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 22 April 2026 Resolved
Record in a log book information on all access and use of the vessel's master key, including-dates and times of access;the room or location accessed; and the name and rank of the crew member that used the master key. The key log book was not available during the inspection. 46 USC 3106(a)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: SASH key control log book was present in the lockbox.
14 - Pollution Prevention › N/A - No Subsystem › VGP: Notice of Intent (NOI)
Issued 22 April 2026 Resolved
If your vessel is greater than or equal to 300 gross tons or the vessel has the capacity to hold or discharge more than 8 cubic meters (2,113 gallons) of ballast water, you must submit a signed and certified, complete and accurate NOI. 1) Vessel produced no proof of NOI submission. 2) Also missing Drydock Inspection Report. EPA VGP (2013) - 1.5.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: NOI was submitted by contracted 3rd party after deficiency.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 22 April 2026 Resolved
Each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. This letter sets forth conditions of operation. The previous stability letter issued to the vessel cited a trim and stability booklet including weights which were removed during retrofit. Submit plans to reflect the current operating parameters.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: All removed equipment was found to be modular cargo gear. The lightship characteristics have not substantially changed to required updates.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 22 April 2026 Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval covering the proposed work except as modified by § 91.45-1. The fire and safety plan require updates to capture route and service changes. Submit plans to OCMI for onboard verification.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2026
Resolution: MI walked the updated fire control plan, but noted 8 items for final revision. Vessel is outfitted appropriately, MI will stamp plan when available. Reissued the 835 as 30-day.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 22 April 2026 Resolved
No person may operate an oceangoing ship of 400 gross tons and above unless it is fitted with approved 15 parts per million (ppm) oily-water separating equipment for the processing of oily mixtures from bilges. Approval letters for engine room OWS were not available during inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Type approval certificate was provided for review.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 22 April 2026 Resolved
Transfer procedures must be permanently posted or available at a place where the procedures can be easily seen and used by members of the crew... Transfer procedures were not available during inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Transfer procedures were available onboard and reviewed by MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2026 Resolved
Each panelboard must have a circuit directory that has the rating or setting of the overcurrent protective device for each circuit. Distribution panels throughout the vessel were missing amperage on the circuit directory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: MI walked cirucuit panels to verify amperage was listed on the directories.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 April 2026 Resolved
The manufacturer's instructions for onboard maintenance of lifesaving appliances must be on board the vessel. Regarding rescue boat maintenance the vessel did not have manufacturer instructions, or records of weekly, monthly, or annual servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Maintenance instructions were available on board and the C/M generated a PMS card for the rescue boat.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 22 April 2026 Resolved
All ships of 150 gross tonnage and upwards shall be fitted with a bridge navigational watch alarm system (BNWAS). No BNWAS installed 74 SOLAS (20) V/19.2.2.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: BNWAS was installed and tested.
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 22 April 2026 Resolved
Systems and equipment, including associated back-up arrangements perform the functional requirements of regulations 19 and 20 shall conform to appropriate performance standards... The daylight signaling lamp needs three total spare bulbs, only had one on board. 74 SOLAS (20) V/18.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2026
Resolution: POC provided invoice or purchased and anticipated delivery. 835 reissued as a 30-day.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2026 Resolved
Each vessel must carry lifebuoys approved under approval series 160.150. 6 lifebuoy were found with wasted plugs, 3 lifebuoy spares were kept on board. Replace the renew or replace the remaining 3.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Lifebuoys were replaced with appropriate appliances.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 22 April 2026 Resolved
Each immersion suit or anti-exposure suit must be marked in such a way as to identify the person or vessel to which it belongs. Immersion suits were not marked.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2026
Resolution: Immersion suits were marked with the vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2026 Resolved
Each lifejacket, and immersion suit container must be marked in block capital numbers with the quantity of the equipment stowed inside the container. Areas where multiple lifejackets and immersion suits are store need to be marked with the number of appliances stored in such area (i.e. bridge, rescue boat, engine room).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2026
Resolution: Containers were appropriately marked as required.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2026 Resolved
The fireman's outfits must be stored in widely separated, accessible locations. 1) The fire suits were stored in the same locker. 2) Neither suit had an oxygen depletion meter.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2026
Resolution: Fire suits were seperated and installed with O2 depletion meters.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 April 2026 Resolved
A vessel of the United States on a voyage from a port in the United States to a foreign port, and a vessel of the United States of at least 75 gross tons on a voyage between a port of the United States on the Atlantic Ocean and Pacific Ocean, shall be provided with a medicine chest. Medicine chest onboard had expired medication, replenish inventory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Expired medicine was removed, and replenished.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 April 2026 Resolved
Each alleyway, stairway, and exit giving access to a muster and embarkation station must be adequately illuminated by lighting that is capable of having its power supplied by the vessel's emergency source of electrical power. The exterior emergency lighting was not appropriately supplied on emergency power. Port Engine Room Fiddley light not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Conducted darkship walk and verified appropriate emergency lighting.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 April 2026 Resolved
During preparation and launching, the survival craft, its launching appliance, and the area of water into which it is to be launched are illuminated by lighting supplied from the vessel's emergency source of electrical power. Install emergency lights to illuminate the water's edge when launching.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Conducted darkship walk and verified appropriate emergency lighting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2026 Resolved
Electric installations on vessels must ensure protection of crew, other persons, and the vessel from electrical hazards. 1) #32 & #36 emergency light in the engine room had one light broke from case and hanging by the electrical wires. 2) Electrical outlet at the top of ladder well prior to entering 01 level is missing an outlet cover.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Verified electrical appliances were replaced and covered.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 April 2026 Resolved
The integrity of a stair tower shall be maintained by “A” Class doors at every level. The doors shall be of self-closing type. Two self-closing doors in the stair tower were not fully self-closing, adjust.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Doors were properly adjusted for self-closing.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 April 2026 Resolved
The outlet at the fire hydrant must be limited so that the hose will lead horizontally or downward to minimize the possibility of kinking. Fire hose at station #10 port side in the engine room is facing straight up and the hose is kinked.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Hydrant was adjusted to the horizontal axis.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2026 Resolved
Paint lockers shall be constructed of steel or shall be wholly lined with metal. 1) The installed paint locker is wasted and holed on the top leading edge. 2) The locker was missing a pressure relief device.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Vessel replaced the paint locker but did not wish to replumb the CO2 extinguisher, they instead elected to follow the regulatory req to have a 40 B in the vicinity.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 22 April 2026 Resolved
Dampers shall be such that openings in the upper portion of the space can be closed off either by permanently installed means or canvas. Handle for damper closure was missing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Damper handle replaced.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Sulphur oxides
Issued 22 April 2026 Resolved
The sample location must be clearly marked for easy identification. Recently installed sample ports were not marked for identification. MARPOL 73/78 Annex VI/14.10 - MEPC.1/Circ.864/Rev.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2026
Resolution: Sample ports were properly marked with purpose.
Engineering › Fuel Oil Service System › Piping
Issued 27 April 2017 Resolved
Inspector observed a F/O leak in the non-metallic expansion joint of the purifier system. All potential fire hazards must be eliminated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 16 May 2017
Resolution: The leak was repaired.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 27 April 2017 Resolved
Inspector observed F/O leaks in the return lines of the port and stbd MDE's. All potential fire hazards must be eliminated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 16 May 2017
Resolution: The leaks were repaired.
Documentation › Logs/Records › Oil Record Book
Issued 27 April 2017 Resolved
Inspector observed improper transfer entries in the ship's ORB in regards to all code 15 entries; conducted training/education with the Master and C/E. Logs will be reinspected to ensure proper entries are being made.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 16 May 2017
Resolution: Evidence was provided in the Oil Record Book that new entries were recorded properly.
Engineering › Bilge Water Management System › Valve
Issued 4 March 2016 Resolved
Check valves painted shut. Vessel shall prove proper operation of all check valves in bilge system prior to getting underway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2016
Resolved 10 March 2016
Resolution: Tested entire bilge system, all sat.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Discharge Hose
Issued 4 March 2016 Resolved
Replace cracked CO2 flexible hose to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 10 March 2016
Resolution: Replaced hose.
Electrical › Electric Supply System (service) › Cable
Issued 4 March 2016 Resolved
Properly secure all loose electrical cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 10 March 2016
Resolution: Wires properly stored & witnessed by marine inspector.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 March 2016 Resolved
Replace or prove proper operation of #33 E-light
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 14 March 2016
Resolution: Installed a new E-Light in the engine room to the satisfation of the attending CGMI.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 20 June 2014 Resolved
Repair gyro repeater: Starboard, aft steering station.
Action required: 705 - Other - as specified
Due 19 July 2014
Resolved 23 June 2014
Resolution: Determined that this repeater was extra / beyond requirements.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 15 December 2010 Resolved
Port potable water tank found to have a 12" semi-circle crack on tank bulkhead. Operator instructed to provide repair proposal and weld procedures to be used for insert. 46 CFR 91.30-1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 December 2010
Resolution: Received repair proposal and weld procedures. Inspected insert in swash bulkhead (fr 17) 12" x 15" and inboard bulkhead of port potable water tank below sewage tank 18" x 24", no discrepancies noted. Witnessed 2 psi air test, All SAT.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 10 May 2007 Resolved
Provide 50% of the crew with first aid/CPR certification.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 7 June 2007
Resolution: Provided first aid/CPR certification for 50% of the crew.
Communications › Visual Communication › Signalling Lamp
Issued 10 May 2007 Resolved
Demonstrate proper operation of the day light signalling lamp from a branch circuit from the ships power source and connected to no other circuit.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 7 June 2007
Resolution: Demonstrated proper operation of the day light signaling lamp from a branch circuit from the ships power source and not connected to another circuit.
Lifesaving › Immersion Suits › General
Issued 10 May 2007 Resolved
Provide an extra large immersion suit and life jacket for the chief mate and prove that the fit him properly.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 May 2007
Resolved 7 June 2007
Resolution: Provided an extra large immersion suit and life jacket for the chief mate that fit him properly.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 10 May 2007 Resolved
Provide a vessel response plan.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 7 June 2007
Resolution: Provided a letter of the work status of the vessel and the non requirement of a vessel response plan.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 10 May 2007 Resolved
Properly mount heat detectors port and starboard side of steering compartment.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 7 June 2007
Resolution: Properly mounted heat detectors port and starboard side of steering compartment.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 10 May 2007 Resolved
Provide line diagrams for all fixed Co2 system installations and post near all manual pull stations and in all Co2 spaces capable of discharging Co2.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 7 June 2007
Resolution: Provided line diagrams for all fixed Co2 system installations and posted them near all manual pull stations and in all Co2 spaces that are capable of discharging Co2.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 May 2007 Resolved
Properly support wiring for the 01 deck outside telerphone.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 7 June 2007
Resolution: Properly supported wiring for the 01 deck outside telephone.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 10 May 2007 Resolved
Install a 2in extention on the end of the fixed Co2 siren piping in the thermal fluid heater compartment.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 7 June 2007
Resolution: Installed a two inch extension on the end of the fixed Co2 siren piping in the thermal fluid heater compartment.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 10 May 2007 Resolved
Install a pre engineered fixed Co2 fire fighting system in the paint locker.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 7 June 2007
Resolution: Installed a pre-engineered fixed Co2 fire fighting system in the paint locker.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 10 May 2007 Resolved
Demonstrate proper operation of the installed automatic radar plotting aid.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 7 June 2007
Resolution: Demonstrated proper operation of the installed automatic radar plotting aid.
Engineering › Bilge Water Management System › Not Operational
Issued 10 May 2007 Resolved
Demostrate compliance with reporting and documenting ballst water management.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 7 June 2007
Resolution: Demonstrated compliance with reporting and documenting ballast water management.
Lifesaving › Lifeboat Equipment › Oar
Issued 10 May 2007 Resolved
Provide a heaving line and ladder for the rescue boat.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 7 June 2007
Resolution: Provided a heaving line and ladder for the rescue boat.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 10 May 2007 Resolved
Renew all expired hospital space supplies.
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 7 June 2007
Resolution: Renewed all expired hospital space supplies.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 12 May 2006 Resolved
Replace seven flexible loops on the CO2 systems as required by 46 CFR 95.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 30 May 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 12 May 2006 Resolved
Label CO2 system pressure switches for the Engine Room controls as required by 46 CFR 95.15-10(d).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2006
Resolved 12 May 2006
Resolution: Labeled CO2 system pressure switches for the engine room controls
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 12 May 2006 Resolved
Replace #2 port and starboard cargo hatches.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 30 May 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 May 2006 Resolved
Prove proper operation of #11 emergency light in Rec room as required by 46 CFR 112.43.
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 12 May 2006
Resolution: Replace battery and proved proper operation of #11 emergency light
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 12 May 2006 Resolved
Provide operating instructions for engine room CO2 actuation stations as required by 46 CFR 95.15-10 (d).
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 12 May 2006
Resolution: Installed operating instructions for engine room CO2 actuation station
Documentation › Certificates/Documents › FCC SSL
Issued 12 May 2006 Resolved
Provide updated FCC document to reflect proper vessel name.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 30 May 2006
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 12 May 2006 Resolved
Install port anchor in accordance with ABS rules.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 30 May 2006
Construction/Loadline › Hull › Hull Plating
Issued 22 April 2006 Resolved
Crop and renew as original, approximately 6 ft x 3 ft section of sideshell plating in way of starboard 02 deck bits, to include two deep frame angles in compartment below that support existing plate to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 11 May 2006
Resolution: Inspected fitup of 6 x 3 ft section of sideshell palting and found satisfactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 April 2006 Resolved
Repair navigation light wiring damaged from forward mast being bent and crushing wiring.
Action required: 705 - Other - as specified
Due 23 April 2006
Resolved 23 April 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 April 2006 Resolved
Repair forward mast as original due to collision and being bent 30 degrees to the aft.
Action required: 705 - Other - as specified
Due 23 April 2006
Resolved 23 April 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 11 July 2005 Resolved
Make proper repairs to tighten multi-cable transit unit forward of the engine room.
Action required: 705 - Other - as specified
Due 7 August 2005
Resolved 8 August 2005
Resolution: Cable transit unit was properly repaired using fire-stop
Electrical › Electrical Distribution System (service) › Cable
Issued 11 July 2005 Resolved
Tighten multi-cable transit unit aft of OWS room.
Action required: 705 - Other - as specified
Due 7 August 2005
Resolved 8 August 2005
Resolution: Cable transit unit was properly repaired using fire-stop.
Construction/Loadline › Hull
Issued 8 January 2003 Resolved
You are directed to drydock the vessel no later than 09 July 2003, to carry out permanent repairs to the flat keel in the port dirty oil tank. All repairs are to be to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2003
Resolved 8 August 2003
Resolution: Witnessed sat repair.
Construction/Loadline › Hull
Issued 8 January 2003 Resolved
Con't The temporary repairs in the above tank are to be regularly monitored and additionally no oily waste or water is to be pumped into this tank until permanent repairs are made. Any change to the temporary repairs are to be immediately reported to the local Officer in Charge, Marine Inspection." LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2003
Resolved 8 August 2003
Resolution: Witnessed sat repair.
Communications › Alarms/Indicators
Issued 8 July 2002 Resolved
Prove proper operation of all rudder angle indicators from all stations as required by 46 CFR 113.40. LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 705 - Other - as specified
Due 8 August 2002
Resolved 13 August 2002
Resolution: Installed new rudder angle indicators at all three control stations located in the pilot house, tested satisfactory.
Communications › Alarms/Indicators
Issued 8 July 2002 Resolved
Prove proper operation of general alarm bell located on 03 deck, portside as required by 46 CFR 113.25-9(b). LEGACY COMPONENT DESC: General Alarm
Action required: 705 - Other - as specified
Due 8 August 2002
Resolved 9 July 2002
Resolution: General alarm bell repaired. Witnessed operational test of general alarm bell.
Pollution Prevention/Response › Prevention Equipment
Issued 8 July 2002 Resolved
Provide test procedures and prove proper operations of the oily water seperator as required by 33 CFR 155.350. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 8 August 2002
Resolved 13 August 2002
Resolution: Vessel rep provided procedures and proved proper operation of oily water seperator.
Electrical › Lighting (emergency)
Issued 8 July 2002 Resolved
Provide proper operation of emergency light located above marine sanitation device and provide new support arm for emergency light forward, starboard side engine room as required by 46 CFR 112.39-3. LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 705 - Other - as specified
Due 8 August 2002
Resolved 9 July 2002
Resolution: Replaced lights above marine sanitation device. Repaired broken support arm holding emergency light in engine room. Witnessed operational tests.
Lifesaving › Lifebuoys
Issued 8 July 2002 Resolved
Provide new batteries with expiration date for all water lights as required by 46 CFR 94.43-5 (b). LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 August 2002
Resolved 13 August 2002
Resolution: Vessel rep provided new batteries for all water lights.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 8 July 2002 Resolved
Provide new discharge hose for portable fire extinquisher #21 as required by 46 CFR Table 91.25-20(a)(1). LEGACY COMPONENT DESC: Discharge Hose/Tube
Action required: 705 - Other - as specified
Due 8 August 2002
Resolved 13 August 2002
Resolution: Vessel rep provided new discharge hose for portable fire extinquisher #21.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 8 July 2002 Resolved
Provide new belly band holding #21 portable fire extinquisher to mounting bracket as required by 46 CFR 97.15-60. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 August 2002
Resolved 13 August 2002
Resolution: Vessel rep installed new belly band for #21 portable fire extinquisher.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 8 July 2002 Resolved
Provide documentation that flexible loops on all CO2 bottles for fixed system have been hydrostatically tested as required by 46 CFR 95.05-10.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2002
Resolved 9 July 2002
Resolution: Flexible loops on CO2 bottles hydrostatically tested on 07/08/2002. Test properly documented and flexible loops date stamped.
Deck/Cargo
Issued 5 June 2001 Resolved
PROVE PROPER OPERATION OF OIL CONTENT MONITOR OR PROVIDE CALIBRATION CERTS.
Condition: Unknown
Due 5 July 2001
Resolved 9 July 2001
Lifesaving
Issued 5 June 2001 Resolved
PROVIDE 4 USCG APPROVED THERMAL PROTECTIVE AIDS FOR RESCUE BOAT IAW 46CFR 199.175.
Condition: Unknown
Due 5 July 2001
Resolved 9 July 2001
Accommodation/Occupational Safety
Issued 5 June 2001 Resolved
REPLACE ALL TRASH CANS WITH NON-COMBUSTIBLE TRASH CANS.
Condition: Unknown
Due 5 July 2001
Resolved 9 July 2001
Engineering
Issued 5 June 2001 Resolved
PROVIDE ACCESS TO ENGINE ROOM VENT SYSTEM ON PORT SIDE CARGO DECK AREA.
Condition: Unknown
Due 5 July 2001
Resolved 9 July 2001
Electrical
Issued 20 October 1999 Resolved
Install and demonstrate to the satisfaction of the attending marine inspector embarkation lighting and necessary changes to the lifesaving equipment plan IAW 46 CFR 199
Condition: Unknown
Due 5 December 1999
Resolved 19 January 2000
Documentation
Issued 30 October 1995 Resolved
Submit for approval an addendum page to the Periodic Test Procedures Rev.D dated 08SEP95 addressing over speed testing of propulsion and generator diesel engines as required by Marine Safety Center approval letter Serial: E2-9503922 of 30OCT95.
Condition: Unknown
Due 30 October 1995
Resolved 30 October 1995
Deck/Cargo
Issued 11 July 1995 Resolved
Prove proper operation of all Thermal Fluid Heater automation after repairsto heating coils. The heating coils are holed and will be replaced during the vessels next drydock in May 96.
Condition: Unknown
Due 11 July 1995
Resolved 11 July 1995
Accommodation/Occupational Safety
Issued 11 July 1995 Resolved
Repair high level alarm in sewage holding tank.
Condition: Unknown
Due 11 July 1995
Resolved 17 July 1995
Construction/Loadline
Issued 11 July 1995 Resolved
Reapir OWS and prove proper operation.
Condition: Unknown
Due 11 July 1995
Resolved 17 July 1995
Lifesaving
Issued 20 July 1994 Resolved
Install Power failure/Loss of power alarm on bridge panel, as noted on machinery monitoring alarm manual.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Lifesaving
Issued 19 July 1993 Resolved
PLACE ONBOARD VESSEL NOT LATER THAN 20 AUG 93 A COPY OF THE HELICOPTER OPERATIONS MANUAL APPROVED 07JUL93 BY CID, MSO MOBILE, ALSO COMPLETE THE REQUIRED DRILLS TO THE SATISFACTION OF THE LOCAL OCMI'S CG MARINE INSPECTOR._x001C_
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993
Electrical
Issued 19 July 1993 Resolved
COMPLETE REPAIRS (CALL STATION BUTTONS) FOR PUBLIC ADDRESS SYSTEM FOR THE FOLLOWING STATIONS; PORT MAIN DECK AFT, STBD MAIN DECK AFT, STBD 01 DECK OUTBOARD THERMAL FLUID HTR ROOM. TO BE CORRECTED AND DEMONSTRATED TO THE SATISFACTION OF THE ATTENDING CG MAIRINE INSPECTOR _x001C_
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993

Casualty record · 3

21 April 2006Routine · role: Involved in a Marine Casualty · activity 2634077
20 January 2009Routine · role: Involved in a Marine Casualty · activity 3398409
18 August 2009Routine · role: Involved in a Marine Casualty · activity 3577161
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MISSISSIPPI RESPONDER (2006–2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.