MAURY USCG vessel records
← All vessels

STAR LEGEND

STAR LEGEND is a 1990 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in April 2023, along with 21 deficiencies and 1 operational control.

Records from 2016 to 2023. Most recent: inspection, 15 April 2023.

Built
1990
Last inspected
15 April 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9008598
373179
Flag
NORWAY
Maury page id
psix-373179

Inspections, by type

…with no type recorded4
Years with a record 6 calendar years (2016–2023)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it3019 - Simplified, Net Ton
3019 - Convention (Subpart B), Net Ton
790 - Dead Weight, Ton
9961 - Simplified, Gross Ton
9961 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 17

15 April 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7669029
8 April 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7665013
5 April 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7663351
17 December 2022 PSC A · COC-CVE Initial · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7610439
28 July 2021 COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 7270197
2 November 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6847515
28 October 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6843343
1 October 2019 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6820671
12 September 2019 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6810671
29 July 2019 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6767583
17 May 2019 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6688852
27 March 2019 ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6642229
24 August 2018 COC-CVE Quarterly · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6519735
17 May 2018 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6417360
17 May 2018 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6436332
31 January 2018 Administrative Inspection · COC-CVE Annual · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6346683
16 December 2016 Ballast Water Examination · COC-CVE Annual · Deficiency Check · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6058356

Deficiency record · 21

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 April 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel reported a lube oil leak originating from the port side shaft seal. SOLAS (20) CH.I/11(a). 17ac.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2023
Resolution: Leak due to standard maintenance; system reset and problem resolved. Verified by DMI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 December 2022 Resolved
Automatic sprinkler, fire detection and fire alarm systems…The pump and piping system shall be capable of maintaining the necessary pressure at the level of the highest sprinkler to ensure a continuous output of water sufficient for the simultaneous coverage of a minimum area of 280 m2 at the application rate specified in paragraph 3. When testing of the automatic sprinkler system PSCOs found only 3 pumps were operable. Pump 4 is currently under a condition of class. Only 3 of the 5 pumps are operational bringing into question the reliability of the system. 74 SOLAS 97 II-2/12
Action required: 30 - Ship detained
Resolved 17 December 2022
Resolution: Recommendations from BV: “Repair of renew the no. 1 and no.4 Flexi-fog pump automatic start relays. In the meantime, the emergency response actions are to be amended and the emergency response teams duly informed.”
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 17 December 2022 Resolved
Except as specified in paragraph 3 of this regulation, any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. Crew was unable to test OWS when asked by PSCOs due to a failed suction pump rendering the system inoperable. MARPOL 2017 Annex I / 14.2
Action required: 30 - Ship detained
Resolved 17 December 2022
Resolution: Recommendations from BV: ÓWS pump to be definitively repaired. In the meantime, (a) the deficiency is to recorded in the Oily Water Record Book, (b) Oil water to be retained onboard, (c) Oily water and waste oil to be discharged ashore as needed.”
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 December 2022 Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. PSCOs observed fire door 640 (starboard side main galley), when in the closed position, had an approximate 15 millimeter gap which would allow the passage of smoke and flame between the top and sides of the door and frame. 74 SOLAS 97 II-2/30.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2022
Resolution: Recommendations from BV: “The galley FSD gap is to be definitively repaired. In the meantime, fire patrols are to regularly inspect the FSD.”
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 December 2022 Resolved
Fire doors in main vertical zone bulkheads…shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees. PSCOs observed fire doors 180 and 188 unable to fully close when tested locally. 74 SOLAS 97 II-2/30.4.1
Action required: 10 - Deficiency Rectified
Resolved 17 December 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2019 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Dead ended electrical cables were located at deck 8 fwd fire station #1 and on the bridge in port side utility closet.
Action required: 10 - Deficiency Rectified
Resolved 18 September 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 September 2019 Resolved
Structural fire protection arrangements shall be in accordance with reg 20 table 1. Combustible material was stored in a category 10 A/C space 265A, flammable material was stored in a deck 2 corridor locker and combustible material was stored above sprinkler heads in a deck 5 lobby and deck 2 carpenter shop.
Action required: 10 - Deficiency Rectified
Resolved 18 September 2019
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 18 September 2019 Resolved
Fireman's outfit shall consist of personal equipment comprising protective clothing of material to protect skin from the heat radiating from fire and from burns and scalding by steam. Two fire suits were damaged or worn beyond usage.
Action required: 10 - Deficiency Rectified
Resolved 18 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 18 September 2019 Resolved
Before the ship leaves port and at all times during the voyage. all life saving appliances shall be in working order and ready for immediate use. The starboard rescue boat's drainage scuppers and exhaust back flow preventer were wasted beyond use.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2019
Resolution: Class sent report attesting to the renewal of the back flow preventers for starboard rescue boat's drainage scuppers and exhaust.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 March 2019 Resolved
Class A divisions shall provide resistance to fire and smoke. The purifor class A door was found to have a missing latch.
Action required: 10 - Deficiency Rectified
Due 27 March 2019
Resolved 27 March 2019
Resolution: Latch was replaced prior the the completion of the exam.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 27 March 2019 Resolved
Davit launched life raft shall be in compliance with requirements of reg 13.5. Davit launch hook released early due to release lanyard was not in original configuration IAW OEM.
Action required: 10 - Deficiency Rectified
Due 27 March 2019
Resolved 27 March 2019
Resolution: Extra release lanyard was removed and returned to OEM original condition.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 16 December 2016 Resolved
In Passenger Ships, The minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 26.1 to 26.4. In the galley, there is an office with a section of bulkhead removed and substituted by plexi glass for viewing. 74SOALS(97)II-2/26.1 50ac
Action required: 705 - Other - as specified
Due 16 January 2017
Resolved 21 January 2017
Resolution: Received Class attestation and verified correction of deficiency.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 16 December 2016 Resolved
All waste receptacles shall be constructed of Non-combustible materials. Several waste receptacles were of the combustible type. 74SOLAS(97) II-2/18.5 50ac
Action required: 705 - Other - as specified
Due 16 January 2017
Resolved 21 January 2017
Resolution: Received Class attestation and verified correction of deficiency.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 16 December 2016 Resolved
The condition of the ship shall be maintained to conform to the present regulating. There shall be a separation between a machinery space and an accomodation space/stair. Per plan review. 74SOLAS(14)I/11 ac
Action required: 705 - Other - as specified
Due 20 February 2017
Resolved 3 March 2018
Resolution: Vessel has established separation between machinery space and accomodation speace per plan review. Attending USCG inspector and Class surveyor in attendance. All Sat.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 16 December 2016 Resolved
The Condition of the ship shall be maintained to conform to the present regulations. the crew galley on deck four (frames 15-28) center line, has been redesignated as a category (12) galley, and structural fire protection to be added. 74SOLAS(14)I/11 50ac
Action required: 705 - Other - as specified
Due 20 February 2017
Resolved 18 January 2023
Resolution: BV Class Surveyor extended deficiency until 01MAR2020
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 December 2016 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent tape. The low location lighting on deck 4, main vertical zone 1 was not illuminating. 74SOLAS(97)II-2/28.1.10 50ac
Action required: 705 - Other - as specified
Due 16 January 2017
Resolved 21 January 2017
Resolution: Received Class attestation and verified correction of deficiency.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 16 December 2016 Resolved
Doors shall be self closing (doors on main vertical zone bulkheads and stairway enclosures). The following self-closing doors were not operating as intended: 345A, 355, 367, 340, 279, 586, 573,. Door 340 showed as closed but was physically open. 74SOLAS(97)II-2/30.4.1 50ac
Action required: 705 - Other - as specified
Due 16 January 2017
Resolved 21 January 2017
Resolution: Received Class attestation and verified correction of deficiency.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 16 December 2016 Resolved
In all service spaces there shall be installed an automatic sprinkler system arranged as to protect such spaces. The deck 5, electrical locker (aft) there is fire detection, but no fire suprpression system. 74SOLAS(81ammendments) II-2/36.1.1 50ac
Action required: 705 - Other - as specified
Due 16 January 2017
Resolved 21 January 2017
Resolution: Received Class attestation and verified correction of deficiency.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 16 December 2016 Resolved
The following basic principles underlie the regulations as appropriate: restricted use of combustable materials. There was excessive combustible materials stored in the following areas: Printing room (422), Carpet store (588), staircase well deck 2 near door (579), central store room engineering, deck 5 (166), carpenter workshop deck 3, deck 5 electric locker aft. 74SOLAS(81)II-2/Reg2.2.3 50ac
Action required: 705 - Other - as specified
Due 16 January 2017
Resolved 21 January 2017
Resolution: Received Class attestation and verified correction of deficiency.
Personnel › Training › Fire Fighting Basic
Issued 16 December 2016 Resolved
Crew members shall be trained and famiilar with the ship as well as the location and operation of any firefighting systems and appliances they may be called upon to use. Laundry supervisor was unfamiliar with installed fire suppresion system and location of portable fire extinguishers in his work space. Crew laundry cleaning schedule for lint not being followed. 74SOLAS(14)II-2/15.2.2.1 50ac
Action required: 705 - Other - as specified
Due 16 January 2017
Resolved 21 January 2017
Resolution: Received Class attestation and verified correction of deficiency.
Fire Fighting › Ventilation Systems › Ducts
Issued 16 December 2016 Resolved
Where ventilation systems penetrate decks, precautions shall be taken. Vertical ducts shall, if necessary, be insulated as required by the appropriate tables in Reg 26. The insulation was damaged or missing on the ventilation in the central passage store room on deck 5. 74SOLAS(81)II-2/32.1.3 50ac
Action required: 705 - Other - as specified
Due 16 January 2017
Resolved 21 January 2017
Resolution: Received Class attestation and verified correction of deficiency.