Records from 2017 to 2025. Most recent: inspection, 10 July 2025.
Inspection history · 14
10 July 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8182024
29 April 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8123425
20 August 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7984764
8 August 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7762668
10 April 2023
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7664721
13 July 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7517694
28 June 2021
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7233967
14 April 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7174590
8 July 2020
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6999465
27 June 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6727050
26 April 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6670420
9 August 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6506006
20 July 2017
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6214153
18 April 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6126434
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 July 2025
Resolved
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:
(1) Charts of large enough scale to make safe navigation possible;
(2) U.S. Coast Pilot or similar publication;
(3) Coast Guard Light List;
(4) Tide tables; and
(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel did not have updated charts and publications.
46CFR184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 14 August 2025
Resolution: Recieved photo evidence recitifing the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2025
Resolved
(f) Ring life buoys shall be of first class workmanship and free from any defects materially affecting their appearance or serviceability. Vessels ring life buoy was damaged, needing to be replaced.
46CFR160.050-4(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 5 August 2025
Resolution: Recieved photo evidence rectifying defiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 August 2023
Resolved
"Portable fire extinguishers... The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection." Storage bracket for fire extinguisher on-board found by Marine Inspector to be inadequate and inconveniently located; replace brackets in accordance to manufacturer instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 28 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 August 2023
Resolved
"Each ring life buoy on a vessel must... be approved in accordance w/ 46 CFR 160.050..." Retro-reflective material was observed to be ineffective at time of inspection; replace reflective tape on life buoy
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 28 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 August 2023
Resolved
"Each life buoy w/ a floating waterlight must have a lanyard... securing the waterlight around the body of the ring life buoy." Identified an unattached waterlight that belonged to the vessel's ring life buoy; attach the waterlight back to the ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 28 August 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 August 2023
Resolved
"Electrical equipment on a vessel must be installed and maintained to... Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock" Marine Inspector observed exposed wiring requiring protection from the elements; provide protection to exposed area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 28 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 July 2022
Resolved
1) The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull and protection against fire in case of a sudden unexpected casualty. MI discovered that the insulation/fire protection was defective/damaged/exposed leading to a potential fire hazard in the vessel’s engine space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2022
Resolved 12 August 2022
Resolution: Vessel submitted satisfactor photographic evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2020
Resolved
08 lifejackets were found with deteriorated retroreflective or non solas approved tape.
46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 9 July 2020
Resolution: Received pictures of lifejackets with retro reflective material replaced with solas approved type.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2020
Resolved
Ring lifebuoy did not have dark in color and/or UV resistant lifeline attached and the floating waterlight battery was expired.
46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 29 July 2020
Resolution: Received photos and documentation for new throw line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 July 2020
Resolved
Bilge pump and high level float switch were not properly secured and the visual alarm was inoperable.
46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 29 July 2020
Resolution: Received photos and video of oeperable and properly mounted bilge float switch.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 July 2020
Resolved
Vessel representative could not proved documentation of pre-employment testing, EAP or MIS annual submission with DAPI documentation
46 CFR 16.210
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 29 July 2020
Resolution: Received DAPI paperwork.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 July 2017
Resolved
Provide 2017 Coast Pilot [name withheld], and Tide Table publications.
Due 21 August 2017
Resolved 28 July 2017
Resolution: Viewed satisfactory excerpts from 2017 Coast Pilot and Light List publications, with new 2017 Eldridge publication.
Documentation › Markings/Placards › Official Number (US)
Issued 20 July 2017
Resolved
Post recent COI on vessel.
Due 21 August 2017
Resolved 5 August 2017
Resolution: Received photo documentation of new COI posted aboard vessel.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 20 July 2017
Resolved
Secure lagging or remove from engine overhead.
Due 21 August 2017
Resolved 17 August 2017
Resolution: Received photo documentation of secured lagging above engine compartment.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 July 2017
Resolved
Perform Fireboy operational test with proper engine override in presence of CG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2017
Resolution: Witnessed satisfactory engine override using Fireboy system, and new override switch.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 July 2017
Resolved
Prove proper operation of high water visual alarm.
Due 21 August 2017
Resolved 28 July 2017
Resolution: Visually inspected proper operation of the high water alarm, including audible and visual alarm.