Records from 1992 to 2025. Most recent: inspection, 10 July 2025.
Inspection history · 41
10 July 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8182024
29 April 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8123425
20 August 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7984764
8 August 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7762668
10 April 2023
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7664721
13 July 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7517694
28 June 2021
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7233967
14 April 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7174590
8 July 2020
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6999465
27 June 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6727050
26 April 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6670420
9 August 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6506006
20 July 2017
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6214153
18 April 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6126434
5 December 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4202040
14 July 2011
Deficiency Check · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4080813
7 July 2009
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3526475
6 August 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3291019
18 May 2006
MARPOL Annex V Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2652276
18 April 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2633235
16 May 2005
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2358914
29 June 2004
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2114734
13 April 2004
Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2043041
29 July 2003
Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1860296
30 August 2002
Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1668937
28 August 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1667958
1 May 2002
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1611571
17 May 2001
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1382289
21 June 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1373071
14 June 2000
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1450489
27 October 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 794045
9 September 1999
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1119098
1 September 1999
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1399174
29 April 1998
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 789448
16 April 1998
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 791236
27 August 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 783090
10 June 1996
Hull Examination · MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084328
3 May 1995
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1210740
3 June 1994
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 863559
21 May 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1142959
7 May 1992
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1267330
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 July 2025
Resolved
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:
(1) Charts of large enough scale to make safe navigation possible;
(2) U.S. Coast Pilot or similar publication;
(3) Coast Guard Light List;
(4) Tide tables; and
(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel did not have updated charts and publications.
46CFR184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 14 August 2025
Resolution: Recieved photo evidence recitifing the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2025
Resolved
(f) Ring life buoys shall be of first class workmanship and free from any defects materially affecting their appearance or serviceability. Vessels ring life buoy was damaged, needing to be replaced.
46CFR160.050-4(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 5 August 2025
Resolution: Recieved photo evidence rectifying defiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 August 2023
Resolved
"Portable fire extinguishers... The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection." Storage bracket for fire extinguisher on-board found by Marine Inspector to be inadequate and inconveniently located; replace brackets in accordance to manufacturer instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 28 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 August 2023
Resolved
"Each ring life buoy on a vessel must... be approved in accordance w/ 46 CFR 160.050..." Retro-reflective material was observed to be ineffective at time of inspection; replace reflective tape on life buoy
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 28 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 August 2023
Resolved
"Each life buoy w/ a floating waterlight must have a lanyard... securing the waterlight around the body of the ring life buoy." Identified an unattached waterlight that belonged to the vessel's ring life buoy; attach the waterlight back to the ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 28 August 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 August 2023
Resolved
"Electrical equipment on a vessel must be installed and maintained to... Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock" Marine Inspector observed exposed wiring requiring protection from the elements; provide protection to exposed area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 28 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 July 2022
Resolved
1) The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull and protection against fire in case of a sudden unexpected casualty. MI discovered that the insulation/fire protection was defective/damaged/exposed leading to a potential fire hazard in the vessel’s engine space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2022
Resolved 12 August 2022
Resolution: Vessel submitted satisfactor photographic evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2020
Resolved
08 lifejackets were found with deteriorated retroreflective or non solas approved tape.
46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 9 July 2020
Resolution: Received pictures of lifejackets with retro reflective material replaced with solas approved type.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2020
Resolved
Ring lifebuoy did not have dark in color and/or UV resistant lifeline attached and the floating waterlight battery was expired.
46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 29 July 2020
Resolution: Received photos and documentation for new throw line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 July 2020
Resolved
Bilge pump and high level float switch were not properly secured and the visual alarm was inoperable.
46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 29 July 2020
Resolution: Received photos and video of oeperable and properly mounted bilge float switch.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 July 2020
Resolved
Vessel representative could not proved documentation of pre-employment testing, EAP or MIS annual submission with DAPI documentation
46 CFR 16.210
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 29 July 2020
Resolution: Received DAPI paperwork.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 July 2017
Resolved
Provide 2017 Coast Pilot [name withheld], and Tide Table publications.
Due 21 August 2017
Resolved 28 July 2017
Resolution: Viewed satisfactory excerpts from 2017 Coast Pilot and Light List publications, with new 2017 Eldridge publication.
Documentation › Markings/Placards › Official Number (US)
Issued 20 July 2017
Resolved
Post recent COI on vessel.
Due 21 August 2017
Resolved 5 August 2017
Resolution: Received photo documentation of new COI posted aboard vessel.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 20 July 2017
Resolved
Secure lagging or remove from engine overhead.
Due 21 August 2017
Resolved 17 August 2017
Resolution: Received photo documentation of secured lagging above engine compartment.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 July 2017
Resolved
Perform Fireboy operational test with proper engine override in presence of CG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2017
Resolution: Witnessed satisfactory engine override using Fireboy system, and new override switch.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 July 2017
Resolved
Prove proper operation of high water visual alarm.
Due 21 August 2017
Resolved 28 July 2017
Resolution: Visually inspected proper operation of the high water alarm, including audible and visual alarm.
Documentation › Certificates/Documents › Stability Letter
Issued 5 December 2011
Resolved
Owner/Operator failed to submit stability certification compliance by 01DEC11. Issued CG-835 reducing maximum passengers allowed to 20 based on the assumed average weight per person of 185 pounds and in accordance with 46 CFR 178.320 amended by FR vol. 75, No. 239, USCG-2007-0030. Reduction will remain in effect until Owner/Operator submits stability certification compliance to Coast Guard
Action required: 705 - Other - as specified
Resolved 22 March 2012
Resolution: Addendum to Stability Letter created.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 July 2011
Resolved
Vessel must provide proof of pre-employment drug testing and enrollment in DAPI Program for all licensed operators. Non-enrolled operators may not carry passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2011
Resolution: Representative provided letter attesting to compliance with DAPI for license operators.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 14 July 2011
Resolved
Vessel must replace pre-engineered fire fighting bottle in engine compartment as discussed.
Action required: 705 - Other - as specified
Due 27 July 2011
Resolved 27 July 2011
Resolution: Pre-engineered fire fighting bottle in engien room was properly replace.
Lifesaving › Hand Flares › Not on Board
Issued 14 July 2011
Resolved
Vessel must provide three hand red and three hand orange smoke flares or suitable substitutes. Vessel is restricted to runs no more than 30 minutes from the dock.
Action required: 705 - Other - as specified
Due 27 July 2011
Resolved 27 July 2011
Resolution: Representative provided the correct number of flares required.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 July 2011
Resolved
Vessel must replace frayed battery wire as discussed in way of engine compartment.
Action required: 705 - Other - as specified
Due 27 July 2011
Resolved 27 July 2011
Resolution: Battery wire was properly repair.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 July 2011
Resolved
Vessel must properly dead end wires in forward compartment with either heat shrink or crimp-type end with electrical tape.
Action required: 705 - Other - as specified
Due 27 July 2011
Resolved 27 July 2011
Resolution: Wires were properly dead ended.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 July 2011
Resolved
The vessel did not have a valid USCG COI onboard
Due 14 July 2011
Resolved 14 July 2011
Resolution: COI Inspection completed
Communications › Radio Communications › VHF Radiotelephone
Issued 29 June 2004
Resolved
Provide current FCC safety certificate. Vessel is limited to less than 1000' from shore until this requirement is met.
Due 30 July 2004
Resolved 30 August 2004
Resolution: Received faxed copy of FCC Radio Safety Certificate.
Communications › Radio Communications › VHF Radiotelephone
Issued 29 June 2004
Resolved
Provide current FCC Marine Radio Operator permit. Vessel is limited to less than 1000' from shore until this requirement is met.
Due 30 July 2004
Resolved 30 August 2004
Resolution: Received fax copy of Operator Permit.
Lifesaving › Hand Flares › Not on Board
Issued 29 June 2004
Resolved
Provide signaling devices (distress) for vessel. (LBS 3 red hand flares and 3 orange day smokes). Vessel is limited to less than 1000' from shore until this requirement is met.
Due 7 July 2004
Resolved 14 July 2004
Resolution: Recvd fax from vessel rep showing the purchasing receipt for flares.
Operations/Management › Drug and Alcohol Testing
Issued 30 August 2002
Resolved
Provide proof of enrollment in a drug testing program. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Due 30 September 2002
Resolved 30 August 2002
Resolution: Received fax.
Lifesaving › Lifejacket/PFD (Type I)
Issued 30 August 2002
Resolved
Vessel is replace the required 3 child size life preservers prior to getting underway. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 30 August 2002
Resolved
Vessel is to have fire service technician reattend the vessel to ascertain the problem with the fixed halon system indicator gauge prior to sailing. LEGACY COMPONENT DESC: Tanks
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2002
Fire Fighting › Ventilation Systems
Issued 30 August 2002
Resolved
Vessel si to provide a positive means of closure for the engine room vents prior to sailing. LEGACY COMPONENT DESC: Ducts
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2002
Resolution: Received fax confirmation that closures had been fabricated.
Construction/Loadline
Issued 14 June 2000
Resolved
Make repairs to hull/deck connection where mechanical fasteners (screws) through rub rail have pulled out and damaged deck glass.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Construction/Loadline
Issued 14 June 2000
Resolved
Make proper repairs to skeg/lower rudder support; attachment to keel, renewbushing and correct bearing angle.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Construction/Loadline
Issued 14 June 2000
Resolved
Clear sea strainer of obstructions and renew screen.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Electrical
Issued 1 September 1999
Resolved
Renew improper automotive style snap-on connectors on wire located under the console with UL Marine grade crimp connectors.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Renew flexible lines for bilge and auxilery fire pump with lines suitable for use. Some of the installed lines are rated for "Sanitation".
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Fire Fighting
Issued 1 September 1999
Resolved
Renew FIREBOY fire extinguishing bottle with one sized apropriately for approx. 100cu.ft. engine space.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Fire Fighting
Issued 1 September 1999
Resolved
Provide approved FIREBOY controller to shutdown engine, with associated alarm/over ride panel._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Engineering
Issued 1 September 1999
Resolved
Renew deteriorated engine raw water intake flexible lines.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Lifesaving
Issued 1 September 1999
Resolved
Renew 60ft. line with dark or UV resistant line. Renew short connection tofloating waterlight, and add Type II retroreflective tape in 4 places on both sides.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Unknown
Issued 29 April 1998
Resolved
Provide proof of enrollment in drug testing consortium.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Documentation
Issued 29 April 1998
Resolved
Provide valid Master's license.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Documentation
Issued 3 May 1995
Resolved
PROVIDE PROOF OF ENROLLMENT IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 9 August 1995
Resolved 14 August 1995
Documentation
Issued 3 May 1995
Resolved
PROVIDE VALID FCC STATION AND INSTALLATION LICENSE.
Condition: Unknown
Due 9 August 1995
Resolved 14 August 1995