Behind this panel: 14 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 14
10 July 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8163006
29 April 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8123415
20 August 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7984778
7 August 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7762626
10 April 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7664660
13 July 2022
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7506283
28 June 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7237901
14 April 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7174576
8 July 2020
COI Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6999496
27 June 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6727051
26 April 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6670429
9 August 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6506068
20 July 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6214166
18 April 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6126444
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 July 2025
Resolved
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:
(1) Charts of large enough scale to make safe navigation possible;
(2) U.S. Coast Pilot or similar publication;
(3) Coast Guard Light List;
(4) Tide tables; and
(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel did not have updated pubs and charts.
46CFR184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 14 August 2025
Resolution: Recieved photo evidence rectifying deficency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2025
Resolved
(b) Each...ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessels ring life buoys markings were faded.
46CFR185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 5 August 2025
Resolution: Recieved photo evidence rectifing this deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 August 2023
Resolved
"Portable fire extinguishers... The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection." Storage bracket for fire extinguisher on-board found by Marine Inspector to be inadequate and inconveniently located; replace brackets in accordance to manufacturer instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 August 2023
Resolved
Each ring life buoy on a vessel must... be approved in accordance w/ 46 CFR 160.050..." Retro-reflective material was observed to be ineffective at time of inspection; replace reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 August 2023
Resolved
"All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules." Vessel's stern navigation light was inoperable at the time of inspection. Vessel is restricted to daytime operations only until stern navigation light is operable.
Action required: 705 - Other - as specified
Resolved 8 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 July 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. MI discovered that the vessel's bilge pump was unable to dewater its engine space.
46 CFR 182.500(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2022
Resolution: Received video from operator showing vessel's bilge pump dewatering engine space. Bilge test was satisfactory
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 July 2022
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate prtection from causing fire, machinery failure, and personnel injury. MI discovered a significant water leak coming from a connnection hose/pipe on the vessel's engine.
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 25 July 2022
Resolution: Received video from operator showing no further water leak on the connection hose/pipe on vessel's engine.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 July 2017
Resolved
Provide 2017 Coast Pilot [name withheld], and Tide Table publications.
Due 21 August 2017
Resolved 28 July 2017
Resolution: Viewed satisfactory excerpts from 2017 Coast Pilot and Light List publications, with new 2017 Eldridge publication.
Documentation › Markings/Placards › Official Number (US)
Issued 20 July 2017
Resolved
Post recent COI on vessel.
Due 21 August 2017
Resolved 5 August 2017
Resolution: Received photo documentation of new COI posted aboard vessel.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 20 July 2017
Resolved
Secure lagging or remove from engine overhead.
Due 21 August 2017
Resolved 17 August 2017
Resolution: Received photo documentation of secured lagging above engine compartment.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 July 2017
Resolved
Perform Fireboy operational test with proper engine override in presence of CG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2017
Resolution: Observed satisfactory operational test of vessel Fireboy system, including engine override.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 20 July 2017
Resolved
Conduct sea trials in the presence of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2017
Resolution: Satisfactorily conducted sea trials with vessel, including ahead and astern propulsion.