Inspection history · 45
20 April 2022
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7434482
10 September 2018
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6583407
28 September 2017
ORV Letter of Designation · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6284998
7 October 2015
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5738312
6 October 2015
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5737578
18 August 2015
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5219090
16 July 2014
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4922860
17 June 2014
Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4890537
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200444
2 September 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3583514
22 July 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3275757
19 June 2007
Internal Structural Exam · Hull Examination · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2947945
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806429
27 July 2006
Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2726225
18 August 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2466867
16 May 2005
Re-Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2358950
12 July 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2130495
3 June 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2087271
11 March 2004
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2023294
28 May 2003
Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1803656
14 June 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1632024
1 December 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 90846
22 May 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408740
12 August 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 72706
29 June 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393484
17 July 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 149062
15 June 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466617
14 June 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372463
13 June 1997
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437259
18 December 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762025
4 December 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 196339
12 June 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374654
19 June 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414462
1 April 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 134736
14 June 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422381
17 June 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405397
18 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 661599
15 March 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2895
15 March 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 10734
15 March 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 113670
15 March 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 131398
15 March 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 142574
21 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 73116
17 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 157969
26 June 1992
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470640
Stability › Intact Stability (when using lifting gear) › General
Issued 7 October 2015
No resolution recorded
Provide documentation attesting that the onboard truck crane and A-frame have been approved for lifting operations by USCG taking into account 46CFR170.125 Vesselis prohibited from conducting any lifting operations using onboard truck crane and A-frame.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 October 2015 — due date passed with no resolution recorded
Construction/Loadline › Structures › Deck Plating
Issued 7 October 2015
No resolution recorded
Submit plans/documentation to USCG Marine Safety Center for approval of aft deck modifications that have been made to accommodate installation of A-frame and placement of securing of on board crane.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 November 2015 — due date passed with no resolution recorded
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 18 August 2015
Resolved
46 CFR 176.700(a) Provide documentation to Marine Safety Center (MSC) for replacement of 41 seats with 2 accommodation spaces for 8 racks.
Due 1 September 2015
Resolved 25 August 2015
Resolution: Letter sent to MSC (see documents)
Engineering › Generator (propulsion-electric) › Winding
Issued 18 August 2015
Resolved
46 CFR 182.100 Properly protect moving parts on port generator with guard.
Due 1 September 2015
Resolved 18 August 2015
Resolution: fabricated and installed guard.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 August 2015
Resolved
46 CFR 185.702(d)/720/722/728 Properly conduct and log maintenance and inspections for life floats (weekly/monthly), EPIRB (monthly), and VGP.
Due 19 August 2015
Resolved 18 August 2015
Resolution: Updated procedures to include appropriate checks/documentation
Engineering › Generator (propulsion-electric) › Wiring
Issued 18 August 2015
Resolved
46 CFR 183.100 Properly cover all openings in switchboard for generators.
Due 18 August 2015
Resolved 18 August 2015
Resolution: covered
Engineering › Generator (propulsion-electric) › Winding
Issued 18 August 2015
Resolved
46 CFR 182.430(b) Prove proper operation of stbd generator exhaust/ventilation.
Due 18 August 2015
Resolved 18 August 2015
Resolution: exhaust leak secured
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 16 July 2014
Resolved
#'s 1/2/3/6 main diesel engines would not shut down after the emergency shut down from the bridge was activated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2014
Resolution: Replaced air solenoids, tested, sat
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 16 July 2014
Resolved
Battle lantern face engine room escape route was not working.
Action required: 705 - Other - as specified
Resolved 21 July 2014
Resolution: Renewed battery and lamp, tested, sat
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 July 2014
Resolved
Several "E" lights were too dim and did not illuminate escape routes appropriately
Action required: 705 - Other - as specified
Resolved 21 July 2014
Resolution: Crew replaced bulbs with brighter, sat
Communications › Alarms/Indicators › Fire Alarm
Issued 16 July 2014
Resolved
Fire alarm sensors in the engine room were not working and crew did not know how to test them properly
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2014
Resolution: All engine room alarms were tested, sat
Communications › Public Address System › Loudspeaker
Issued 16 July 2014
Resolved
PA system did not work under emergency power, internally
Due 11 August 2014
Resolved 21 July 2014
Resolution: Tested PA system on emrgency power, all sat
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 16 July 2014
Resolved
Port generator's overspeed did not work
Due 11 August 2014
Resolved 21 July 2014
Resolution: Replaced solenoid, tested overspeed, sat
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 July 2014
Resolved
Did not have alcohol test strips onboard
Due 11 August 2014
Resolved 21 July 2014
Resolution: Purchased new alcohol test strips, sat
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 July 2014
Resolved
Did not have or know information on drug testing.
Due 11 August 2014
Resolved 21 July 2014
Resolution: Vessel worked with company on training and DAPI program manager.
Documentation › Logs/Records › Logbook (official)
Issued 16 July 2014
Resolved
Vessel was not logging drills properly or the testing of the EPIRB
Due 12 October 2015
Resolved 19 August 2015
Lifesaving › Lifefloat › Paddle
Issued 19 June 2007
Resolved
Secure oars in center of floats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2007
Lifesaving › Lifefloat › Painter
Issued 19 June 2007
Resolved
Provide proper lenght of painter.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2007
Lifesaving › Lifefloat › Float Free
Issued 19 June 2007
Resolved
Provide slats between floats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2007
Electrical › Electric Supply System (service) › Battery Charger
Issued 19 June 2007
Resolved
Provide drip tray over battery charger.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2007
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 23 May 2005
Resolved
Provide Ballast Water Management Plan prior to 07 JUN2005.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2005
Resolved 7 June 2005
Resolution: Reviewed plan and found satisfactory.
Engineering › Pressure Vessel › Shell Plate
Issued 11 March 2004
Resolved
Make two outboard pressure vessels (S/Ns 101897 & 101894) available for internal inspection. External condition of PVs, and PV mountings satisfactory. LEGACY COMPONENT DESC: Internal exam
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 12 July 2004
Engineering › Pressure Vessel
Issued 3 July 2003
Resolved
Complete internal inspection of all three pressure vessels. LEGACY COMPONENT DESC: Internal Inspection
Action required: 705 - Other - as specified
Due 3 August 2003
Resolved 11 March 2004
Resolution: Completed external and internal exam of one pressure vessel (built 1997). Conducted external exam of two other PVs, but could not conduct adequate internal exams due to location of inspection ports. Cleared deficiency, but re-issued for two older PVs.
Stability › Watertight Integrity
Issued 6 June 2003
Resolved
Adjust Rudder Room escape hatch. LEGACY COMPONENT DESC: Emergency Escape Hatch
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2003
Resolved 23 June 2003
Engineering › Fuel Oil Service System › Hose
Issued 6 June 2003
Resolved
Replace port generator fuel hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2003
Resolved 23 June 2003
Communications › Radio Communications
Issued 6 June 2003
Resolved
Provide back-up power to single side band radio. LEGACY COMPONENT DESC: Single Side Band Radio
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2003
Resolved 23 June 2003
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 6 June 2003
Resolved
Renew water cooling hoses on stbd and center main engines.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2003
Resolved 23 June 2003
Electrical › Electrical Distribution System (service)
Issued 14 June 2002
Resolved
PILOT HOUSE BREAKERS NOT LABELED PROPERLY. LEGACY COMPONENT DESC: LABELING
Due 14 June 2002
Resolved 14 June 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 14 June 2002
Resolved
NO LUBE OIL TANK VENT INSTALLED ON OIL TANK IN ENGINE ROOM.
Due 14 June 2002
Resolved 14 June 2002
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Silencer (exhaust)
Issued 14 June 2002
Resolved
CRACK LOCATED ON PORT MAIN ENGINE EXHAUST OVERBOARD.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2002
Resolved 14 June 2002
Electrical › Electrical Distribution System (emergency)
Issued 14 June 2002
Resolved
AMMETER ON STARBOARD BATTERY CHARGER INOPERABLE. LEGACY COMPONENT DESC: BATTERY CHARGER
Due 14 June 2002
Resolved 14 June 2002
Stability › Watertight Integrity
Issued 14 June 2002
Resolved
ENGINE ROOM AND STEERING ROOM COMPARTMENT DOORS OUT OF ADJUSTMENT. LEGACY COMPONENT DESC: DOORS
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2002
Resolved 14 June 2002