DOMINIC S

DOMINIC S is a 1978 offshore supply vessel. The Coast Guard has recorded 61 inspections since 1991, most recently in May 2025, along with 97 deficiencies and 3 casualty investigations between 2001 and 2021.

Records from 1991 to 2025. Most recent: inspection, 8 May 2025.

Built
1978
Last inspected
8 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL5085
163051
Flag
UNITED STATES
367424960
Maury page id
psix-163051

Inspections, by type

…with no type recorded11
Years with a record 31 calendar years (1991–2025)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)124.6 ft × 26.0 ft × 10.5 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)124.6 ft × 26.0 ft × 10.5 ft
ITC tonnagegross 236 / net 70
BuilderSCULLY BROS BOAT BUILDING · STEPHENSVILLE, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 8 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Regulatory (Subpart C or D), Net Ton
70 - Convention (Subpart B), Net Ton
87 - Regulatory (Subpart C or D), Gross Ton
236 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL5085MMSI 367424960 · active · compulsorily equipped · granted 17 March 2020, expires 17 March 2030
WDF2107MMSI 367424960 · expired · compulsorily equipped · granted 10 September 2009, cancelled 16 November 2019
WDB8028MMSI 366951750 · expired · compulsorily equipped · granted 26 May 2004, cancelled 26 July 2014 · licensed under a name not among this hull’s recorded names (not shown)
WAQ6011MMSI not assigned · expired · voluntarily equipped · granted 4 December 1995, cancelled 18 March 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 21

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

E.W. ELLEFSEN Industrial Vessel · MISLE 54783 · 28 October 2020 · activity 7086719CROSBY ENDEAVOR Towing Vessel · MISLE 140239 · 28 October 2020 · activity 7086719M/V ROLAND A FALGOUT Towing Vessel · MISLE 149093 · 28 October 2020 · activity 7086719STINGRAY Offshore Supply Vessel · MISLE 168505 · 28 October 2020 · activity 7086719GROUPER Offshore Supply Vessel · MISLE 173804 · 28 October 2020 · activity 7086719BAYLOR J TREGRE Towing Vessel · MISLE 458916 · 28 October 2020 · activity 7086719MR COLBY Offshore Supply Vessel · MISLE 486254 · 28 October 2020 · activity 7086719DB THOR Industrial Vessel · MISLE 800643 · 28 October 2020 · activity 7086719PYTHON 252 Offshore Supply Vessel · MISLE 949500 · 28 October 2020 · activity 7086719GLOBAL JULIE Passenger Barge (Inspected) · MISLE 375122 · 1 December 2001 · activity 90846FOOTPRINT Commercial Fishing Vessel · MISLE 156887 · 27 July 2000 · activity 133920SIR GAWAIN Passenger (Inspected) · MISLE 48005 · 25 November 1996 · activity 132286LONG ISLAND Offshore Supply Vessel · MISLE 49781 · 25 November 1996 · activity 132286MISS DEANNE E Passenger (Inspected) · MISLE 49827 · 25 November 1996 · activity 132286BAYOU 14 J Mobile Offshore Drilling Unit · MISLE 51211 · 25 November 1996 · activity 132286OPR VESSEL Offshore Supply Vessel · MISLE 53047 · 25 November 1996 · activity 132286TONY B. Passenger (Inspected) · MISLE 54133 · 25 November 1996 · activity 132286WMT Offshore Supply Vessel · MISLE 55295 · 25 November 1996 · activity 132286MISS ALLIE Passenger (Inspected) · MISLE 335762 · 25 November 1996 · activity 132286PAN PRODUCER Mobile Offshore Drilling Unit · MISLE 444428 · 25 November 1996 · activity 132286ISABELLA ROSE Offshore Supply Vessel · MISLE 53865 · 28 January 1994 · activity 95223

Inspection history · 61

8 May 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8131391
24 January 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7854234
26 January 2023 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7625832
6 April 2022 Deficiency Check · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7426094
16 December 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7369739
18 November 2021 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7353130
30 October 2020 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7088587
28 October 2020 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7086719
31 August 2020 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7046527
15 April 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6662454
13 March 2019 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6641900
18 December 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6599502
22 May 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6420250
25 May 2017 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6155018
25 April 2017 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6132422
19 November 2015 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5766944
26 January 2012 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4232397
23 January 2012 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4230178
1 February 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3937090
28 January 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3935012
24 November 2010 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3897609
29 January 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3402179
4 June 2008 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3227551
23 April 2007 MTSA Verification · Examination of Repairs · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2913497
19 October 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2803690
3 July 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2702512
7 June 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2382274
25 February 2005 MTSA Verification · Hull Examination · Ballast Water Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2368810
28 June 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2113778
28 June 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2113980
24 June 2004 Deficiency Check · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2124508
17 June 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1827218
8 May 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1789305
3 June 2002 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1615977
1 December 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 90846
23 August 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 31913
30 July 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1069571
21 May 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1065010
24 April 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464368
4 October 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1450530
29 September 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1055050
31 July 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448149
27 July 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 133920
25 February 2000 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1391222
5 May 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442828
30 July 1998 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1471835
29 July 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1437424
22 July 1998 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1129276
6 July 1998 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1441395
12 June 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 141768
8 May 1997 Hull Examination · Initial Construction-Excluding Oversight · COI Inspection · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1434657
25 November 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 132286
7 August 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1092845
9 July 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1086530
20 March 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1405876
26 January 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412908
17 February 1995 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401984
28 January 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 95223
12 February 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 830538
3 April 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225389
8 January 1991 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1222639

Deficiency record · 97

04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 24 January 2024 Resolved
ach vessel must be fitted with a general alarm that complies with subpart 113.25, including sounding in the galley and crew quarters. The general alarm in the galley that also alerts the crew quarters was disconnected.
Action required: 10 - Deficiency Rectified
Resolved 24 January 2024
Resolution: Reconnected the galley general alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 January 2024 Resolved
Main Propulsion is a vital system that is vital to the vessel's survivability and safety. Port and Starboard MDE had fuel leaks running down the engine.
Action required: 10 - Deficiency Rectified
Resolved 24 January 2024
Resolution: Company mechanic corrected fuel leaks.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 18 November 2021 Resolved
Ring, lines, and letters shall be painted in white or yellow on dark ground. Deck line was not painted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2021
Resolution: Deck line was painted prior to departure from vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 November 2021 Resolved
For each lifesaving appliance the maintenance must be logged for inspections, maintenance, and repair. Entries were missed for appliance inspections.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 November 2021 Resolved
Each vessel must carry adequate and up-to-date charts. Chart corrections were not being made.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2021
Resolution: Chart corrections made.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 November 2021 Resolved
Nonconductive mats must be on deck behind switchboard if accessible. No mat behind switchboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2021
Resolution: Nonconductive mat placed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2021 Resolved
Piping conveying gases where temperature exceeds 150 degrees Fahrenheit shall be insulated. Exhaust lagging missing on port generator.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2021
Resolution: Insulation added.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 18 November 2021 Resolved
Crew members shall demonstrate good judgment in an emergency; crew members did not demonstrate comms between the crew and the master during drills.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2021
Resolution: Extra training provided and re-conducted drills.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 November 2021 Resolved
Each vessel must take measures to minimize fire hazards; engine room bilges were filled with 6-12” of water.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2021
Resolution: Oil in bilges cleaned out.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 November 2021 Resolved
Each battery must be free from exposure to water; port generator battery box was filled with water.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 November 2021
Resolution: Water drained from battery box.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 October 2020 Resolved
Vessel shall be made available for inspection after an accident and the repairs, renewals, materials, and workmanship shall be satisfactory to the attending marine inspector. Vessel shall make appropriate repairs as recommended by the provided Central Maritime marine surveyor report, but ultimately to the satisfaction of the attending marine inspector. 46 CFR 126.110 46 CFR 127.210 (a)
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2020
Resolved 20 November 2020
Resolution: All repairs made to the satisfaction of the OCMI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 31 August 2020 Resolved
Each conductor of a control, interlock, or indicator circuit, such as a conductor for instruments, pilot light, ground-detector light or potential transformer, must be protected by an overcurrent device; vsl's port generator oil pressure light did not illuminate; provide proper operation per 46CFR129.380(b) to U.S. Coast Guard Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 31 August 2020
Resolution: Vessel replaced bulb and verified no short in system.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 15 April 2019 Resolved
Rudder angle indicators in operating station and aft steering station were inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2019
Resolved 16 April 2019
Resolution: All RAI were witnessed with a satisfactory rudder swing.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 15 April 2019 Resolved
Navigation light screens were painted white and not matt black.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2019
Resolved 16 April 2019
Resolution: Nav screen was painted matt black.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 April 2019 Resolved
Exhaust lines from MDE and generators were not properly lagged.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2019
Resolved 16 April 2019
Resolution: All appropriate exhaust lines were properly lagged.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 15 April 2019 Resolved
Missing auxillary line for impluse line throwing gun.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2019
Resolved 16 April 2019
Resolution: Auxiliary line was found onboard the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 April 2019 Resolved
Fire station in engine room missing nozzle on fire hose.
Action required: 10 - Deficiency Rectified
Due 15 April 2019
Resolved 15 April 2019
Resolution: Nozzle replaced prior to MI departure from vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 23 January 2012 Resolved
Nav charts for the area frm 2009 and not updated. Provide valid/current Marine charts
Action required: 705 - Other - as specified
Resolved 24 January 2012
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 January 2012 Resolved
Light list on board from 2010 - provide new.
Action required: 705 - Other - as specified
Resolved 24 January 2012
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 23 January 2012 Resolved
Tide tables and tide current expired, provide current version
Action required: 705 - Other - as specified
Resolved 24 January 2012
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 January 2012 Resolved
All fire extinguishers due for inspection no later than 29JAN2012
Action required: 705 - Other - as specified
Due 29 January 2012
Resolved 26 January 2012
Resolution: All portable fire extinguishers serviced and report submitted to USCG.
Communications › Alarms/Indicators › General Alarm
Issued 23 January 2012 Resolved
General alarm inoperable - fix
Action required: 705 - Other - as specified
Resolved 24 January 2012
Construction/Loadline › Structures › Machinery Space Opening
Issued 23 January 2012 Resolved
gasket on emergnecy access hatch on main deck wasted - replace and retest (chalk test) for proper fit.
Action required: 705 - Other - as specified
Resolved 24 January 2012
Construction/Loadline › Structures › Machinery Space Opening
Issued 23 January 2012 Resolved
Engine room access door in machinery space unable to close and seal - replace burst gasket and prope operationa (chalk test) - Additionally noted that operator had secured door open via tying the door open with line. Remove line and secure door while underway as per stability letter.
Action required: 705 - Other - as specified
Resolved 24 January 2012
Construction/Loadline › Penetrations › Pipe Flange
Issued 23 January 2012 Resolved
Goose neck vent on starboard side missing float ball - replace
Action required: 705 - Other - as specified
Resolved 24 January 2012
Navigation › Piloting/Steering › Magnetic Compass
Issued 23 January 2012 Resolved
Magnetic compass lighti inoperable - replace and prove operational
Action required: 705 - Other - as specified
Resolved 24 January 2012
Lifesaving › Lifebuoys › Serviceable
Issued 23 January 2012 Resolved
Label all ring buoys wiht name of the vessel, provide retro tape as needed and untie all ring buoys that are tied to the vessel.
Action required: 705 - Other - as specified
Resolved 24 January 2012
Construction/Loadline › Penetrations › Valve Flange
Issued 23 January 2012 Resolved
Forepeak remote vlave frozen - repair and prove operational and label
Action required: 705 - Other - as specified
Resolved 24 January 2012
Construction/Loadline › Markings › Load Line Mark
Issued 23 January 2012 Resolved
Loadline submerged - remove excess water and prove that Loadline installed on vessel as per certificate.
Action required: 705 - Other - as specified
Resolved 24 January 2012
Lifesaving › Lifefloat › Float Free
Issued 23 January 2012 Resolved
Reinstall life floats in a float free arangement. restow painter line to propely pan out.
Action required: 705 - Other - as specified
Resolved 24 January 2012
Lifesaving › Lifefloat › Serviceable
Issued 23 January 2012 Resolved
install slates between life flaots to prevent rotting on life floats.
Action required: 705 - Other - as specified
Resolved 24 January 2012
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 January 2012 Resolved
Emergency lighting for lifefloat embarkation broken - repair
Action required: 705 - Other - as specified
Resolved 24 January 2012
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 January 2012 Resolved
Emergency lighting for escape hatchin engine room inoperable, as was emergency lighting for machinery space - fix
Action required: 705 - Other - as specified
Resolved 24 January 2012
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 January 2012 Resolved
No COD on board - provide current document.
Action required: 705 - Other - as specified
Resolved 24 January 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 January 2012 Resolved
Provide a new light holder for ring buoy on starboard side and untie ring buoy from the vessel.
Action required: 705 - Other - as specified
Resolved 24 January 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 January 2012 Resolved
Renew protective cover for the exhaust on the starboard engine
Action required: 705 - Other - as specified
Resolved 24 January 2012
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 28 January 2011 Resolved
Provide engine RPM gauges for mde at operating station.
Action required: 705 - Other - as specified
Resolved 2 February 2011
Engineering › Pressure Vessel › Relief Valve
Issued 28 January 2011 Resolved
Renew/provide proper inspection of relief valves on air compressors
Action required: 705 - Other - as specified
Resolved 2 February 2011
Lifesaving › Line-Throwing Appliances › Lines
Issued 28 January 2011 Resolved
Provide auxiliary line for line throwing gun
Action required: 705 - Other - as specified
Resolved 2 February 2011
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 23 April 2007 Resolved
Provide loadline cert prior to next scheduled drydocking. See act # 2913497.
Action required: 705 - Other - as specified
Due 28 September 2010
Resolved 1 February 2011
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 June 2004 Resolved
FWD bilge alarm not operational.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2004
Resolved 6 July 2004
Resolution: Provided working alarm.
Communications › Alarms/Indicators › Rate of Turn Indicator
Issued 24 June 2004 Resolved
RPM gages not operational.
Due 6 July 2004
Resolved 6 July 2004
Resolution: Provided working RPM gages.
Lifesaving › Lifefloat › Serviceable
Issued 24 June 2004 Resolved
Properly service one lifefloat as indicated.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2004
Resolved 6 July 2004
Resolution: Serviced lifefloat.
Construction/Loadline › Hull › Weld
Issued 24 June 2004 Resolved
Fractured main deck iwo stbd side just aft fo amidships as indicated.
Due 6 July 2004
Resolved 6 July 2004
Resolution: Repairs made.
Engineering › Lubricating Oil Service System › Hose
Issued 24 June 2004 Resolved
Provide proper lube oil hose both port and stbd engines as indicated.
Due 6 July 2004
Resolved 6 July 2004
Resolution: Provided.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 24 June 2004 Resolved
Provide working ground detection at generator panel.
Due 6 July 2004
Resolved 6 July 2004
Resolution: Provided.
Navigation › Collision/Grounding Avoidance
Issued 17 June 2003 Resolved
Stern, Anchor, and FWD Mast lights not UL 1104 certified/approved. Stern light mounting broken and attached to mast. LEGACY COMPONENT DESC: Navigation Lights
Condition: Placed in Improper Service
Due 17 July 2003
Resolved 25 June 2003
Resolution: Provided certified NavLights with proper mounting. Stern light moved aft away for mast.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 June 2003 Resolved
Water lights for ring buoys and life floats not working properly and not mounted properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2003
Resolution: Provided working water lights with proper mounting.
Lifesaving › Line-Throwing Appliances
Issued 17 June 2003 Resolved
Missing auxiliary line. LEGACY COMPONENT DESC: Additional Equipment
Due 17 July 2003
Resolved 17 June 2003
Resolution: Provided.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 June 2003 Resolved
Rudder Angle Indicator not provided.
Condition: Unknown
Due 17 July 2003
Resolved 6 July 2004
Resolution: Provided
Electrical › Electric Generation Source (service)
Issued 3 June 2002 Resolved
DEMONSTRATE PROPER OPERATION OF BOTH SSDGEN OVERSPEED DEVICES LEGACY COMPONENT DESC: Overcurrent Device
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 July 2002
Resolved 25 June 2003
Resolution: Demonstrated.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 3 June 2002 Resolved
INSTALL FLAME SCREENS ON ENGIEN ROOM L/O TANK VENT.
Condition: Improper Installation
Due 3 June 2002
Resolved 3 June 2002
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 3 June 2002 Resolved
INSTALL REMOTE STOP FOR THE DIRTY OIL TRANSFER PUMP
Condition: Improper Installation
Due 3 June 2002
Resolved 3 June 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 3 June 2002 Resolved
INSTALL BULB GUARD/COVER FOR RANGE HOOD. LEGACY COMPONENT DESC: COVER FOR GALLEY HOOD
Due 3 June 2002
Resolved 3 June 2002
Communications › Internal Communications System
Issued 3 June 2002 Resolved
INSTALL VISUAL CALL INDICATOR FOR THE ENGINE ROOM INTERCOM PHONE STATION. LEGACY COMPONENT DESC: INTERCOM
Condition: Improper Installation
Due 3 June 2002
Resolved 3 June 2002
Communications › Alarms/Indicators › High Water Alarm
Issued 3 June 2002 Resolved
REPAIR BRIDGE AUDIBLE ALARM INDICATOR FOR THE BILGE HIGH WATER LEVEL ALARM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2002
Resolved 3 June 2002
Communications › Alarms/Indicators
Issued 3 June 2002 Resolved
INSTALL VISAUL ALARM INDICATOR FOR THE ENGINE ROOM ALARM PANEL. LEGACY COMPONENT DESC: VISUAL ALARM INDICATOR
Condition: Improper Installation
Due 3 June 2002
Resolved 3 June 2002
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 June 2002 Resolved
PROVIDE THE FOLLOWING NAUTICAL PUBLICATIONS: LIGHT LIST, COAST PILOTS, TIDAL CURRENTS, TIDES, AND NAVIGATION RULES.
Condition: Unknown
Due 3 June 2002
Resolved 3 June 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 June 2002 Resolved
REMOVE ALL EXTENSION CORDS SERVING AS PERMANENT WIRING UNDER THE P/H CONSLE AND ABOVE THE AFT P/H CONSOLE
Condition: Improper Installation
Due 3 June 2002
Resolved 3 June 2002
Construction/Loadline › Structures › Ventilators
Issued 3 June 2002 Resolved
PROVIDE VENT COVERS FOR THE 01 LEVEL EXHAUST AND INTAKE VENTS
Condition: Placed in Improper Service
Due 3 June 2002
Resolved 3 June 2002
Lifesaving › Buoyant Apparatus
Issued 3 June 2002 Resolved
PROVIDE PROPER SIZE WEAK LINK. LEGACY COMPONENT DESC: WEAKLINKS
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2002
Resolved 3 June 2002
Fire Fighting › Nozzles › Condition
Issued 3 June 2002 Resolved
repair or replace 1 fire hose nozzle.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2002
Resolved 3 June 2002
Electrical
Issued 24 April 2001 Resolved
PROVIDE EMERGENCY LIGHTING AT EMBARKATION STATION AS REQUIRED BY 46 CFR 133.110, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 May 2001
Resolved 22 May 2001
Navigation
Issued 24 April 2001 Resolved
PROVIDE RUDDER ANGLE INDICATORS AS REQUIRED BY 46 CFR 113.40-5, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 May 2001
Resolved 22 May 2001
Lifesaving
Issued 24 April 2001 Resolved
PROVIDE LINE THROWING APPLIANCE AS REQUIRED BY 46 CFR 133.170, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Lifesaving
Issued 24 April 2001 Resolved
PROVIDE GENERAL ALARM AS REQUIRED BY 46 CFR 129.530, EMERGENCY POWER, RED LIGHT IN E/R, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 May 2001
Resolved 22 May 2001
Construction/Loadline
Issued 24 April 2001 Resolved
PROVIDE BILGE PUMP SUCTION MUD BASKET AS REQUIRED BY 46 CFR 56.50-50(g), TOTHE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 May 2001
Resolved 22 May 2001
Construction/Loadline
Issued 24 April 2001 Resolved
PROVIDE TANK VENT CLOSURES AS REQUIRED BY 46 CFR 56.50-85(a)(7)(i)/(ii), TOTHE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 May 2001
Resolved 22 May 2001
Lifesaving
Issued 31 July 2000 Resolved
Replace line used in davit hoist (for stokes litter) with one of at least 3/8" diameter and with ultraviolet protection. District Eight policy letterdated 12NOV98.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Documentation
Issued 31 July 2000 Resolved
Submit for approval Fire Control plan for OCMI review and approval 46 CFR 127.110
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Engineering
Issued 31 July 2000 Resolved
Provide shutdown controls for each propulsion engine at the pilothouse 46 CFR 130.120.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Engineering
Issued 31 July 2000 Resolved
Provide an approved automation testing procedure manual 46 CFR 130.480.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Electrical
Issued 31 July 2000 Resolved
Provide internal communications from the pilot house to the engine room 46 CFR 130.110.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Lifesaving
Issued 31 July 2000 Resolved
Post emergency procedures in accordance with 46 CFR 131.340.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Navigation
Issued 31 July 2000 Resolved
Correct charts to latest Notice to Mariners 46 CFR 130.330.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Engineering
Issued 31 July 2000 Resolved
Flame screen required on combustible liquid vent on main deck.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Construction/Loadline
Issued 31 July 2000 Resolved
Repair/replace engine room scuttle hatch dog.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Lifesaving
Issued 5 May 1999 Resolved
DEMONSTRATE COMPLIANCE WITH 8TH COAST GUARD DISTRICT POLICY FOR "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" DATED 12NOV98 TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 5 June 1999
Resolved 17 June 1999
Construction/Loadline
Issued 5 May 1999 Resolved
INSTALL BILGE ALARMS IAW 46 CFR 130.460 TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 5 June 1999
Resolved 17 June 1999
Navigation
Issued 5 May 1999 Resolved
DEMONSTRATE PROPER OPERATION OF SINGLE SIDE BAND RADIO TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 5 June 1999
Resolved 17 June 1999
Navigation
Issued 5 May 1999 Resolved
INSTALL NAVIGATIONAL LIGHTING IAW 46 CFR 129.430, 111.75-17 (d), AND APPLICABLE NAV RULES TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 5 June 1999
Resolved 17 June 1999
Electrical
Issued 6 July 1998 Resolved
Install blank cover missing on engine room switch board pannel.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Electrical
Issued 6 July 1998 Resolved
Repair overspeed trip control on port generator.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Lifesaving
Issued 6 July 1998 Resolved
Install all ring buoys as required by COI and 46CFR.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Lifesaving
Issued 6 July 1998 Resolved
Install properly dated batteries as needed on required PFD's._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Engineering
Issued 6 July 1998 Resolved
Install new flame screen on port fuel vent.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Engineering
Issued 6 July 1998 Resolved
Fuel transfer hoses not hydro tested as required.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Deck/Cargo
Issued 6 July 1998 Resolved
Renew hydraulic hose on anchor winch.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Electrical
Issued 6 July 1998 Resolved
Repair E light located in engine room port side aft.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Construction/Loadline
Issued 6 July 1998 Resolved
Install dead covers as required on all of vessels portholes.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Lifesaving
Issued 8 May 1997 Resolved
PROVIDE ADDITIONAL RING LIFE BUOYS TO MEET THE REQUIREMENTS SETFORTH IN _x001C_ 46 CFR 133.70. FOUR OF THE REQUIRED EIGHT RING LIFE BUOYS SHALL BE PROVIDEDWITH WATERLIGHTS AND TWO WITH LINES. INSTALLATION OF THE RING BUOYS SHALL BE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Documentation
Issued 20 March 1996 Resolved
Obtain new stability letter for vessel from MSC. Submit to OCMI New_x001C_ Orleans a copy for file._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Navigation
Issued 26 January 1996 Resolved
Provide Radio Telephony Certificate from the FCC for passenger vessels.
Condition: Unknown
Due 26 January 1996
Resolved 26 January 1996
Engineering
Issued 26 January 1996 Resolved
Hyrdo test fuel transfer hoses and stencil MAWP and test date on hose I.A.W. 46/61.15-5 & 33/156.170.
Condition: Unknown
Due 26 January 1996
Resolved 26 January 1996
Lifesaving
Issued 26 January 1996 Resolved
Update life saving instructions/placards and post in a location accessible passengers.
Condition: Unknown
Due 26 January 1996
Resolved 26 January 1996
Documentation
Issued 26 January 1996 Resolved
Provide drug testing data on OCMI form A in accordance 46 CFR Part 16._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 February 1996
Resolved 2 April 1996
Lifesaving
Issued 8 January 1991 Resolved
PROVIDE FOUR (4) MORE PFDs TO INCREASE PAC ON TWELVE (12) HOURS OR LESS TO 16 PAC.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991

Casualty record · 3

1 December 2001Routine · role: Involved in a Marine Casualty · activity 90846
28 October 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7086719
16 December 2021Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 7369739
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

HELEN T. SKANSI (2001). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.