MAURY USCG vessel records
← All vessels

OPR VESSEL

Built
1981
Last inspected
2 October 2019
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 October 2019
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF9387
Flag
VANUATU
Maury page id
psix-53047

Documentation record

Tonnage as PSIX records it310 - Convention (Subpart B), Gross Ton
93 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 11 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; 1 other recorded name; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SANDSHARK Offshore Supply Vessel · MISLE 205514 · 10 January 2016 · activity 5831631

Inspection history · 11

2 October 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6825301
22 July 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6763139
16 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6669411
15 January 2019 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6608416
28 November 2018 Administrative Inspection · Drydock Exam · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6589176
15 March 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6373045
15 March 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6394622
27 December 2016 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6062715
16 December 2016 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6059053
8 March 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5829172
10 January 2016 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5831631

Deficiency record · 11

01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 2 October 2019 Resolved
Dispensation shall not be granted to a Master or [name withheld] Vessel was granted a flag dispensation to sail with Engineer Officer of the watch instead of a [name withheld] shall provide documentation of a qualified [name withheld] that will be sailing with the ship prior to departure. STCW 2011 Article VIII
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2019
Resolved 3 October 2019
Resolution: Qualified Chief Engineer provided as required by Minimum Safe Manning Certificate.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 March 2018 Resolved
Identified a Doubler in the port side bulkhead between stern void/ballast #4, a crack on the centerline bulkhead ballast/void and two wasted areas in the rudder box inside the stern void. C/R and conduct NDT to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2018
Resolved 20 March 2018
Resolution: Witnessed NDT of inserts
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 15 March 2018 Resolved
Provide instructions for transfer procedures from main steering to auxiliary at the auxiliary steering station and prove proper operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 May 2018
Resolved 20 March 2018
Resolution: Witnessed steering test verified proceedures and operation.
Deck/Cargo › Ballast › Tank
Issued 15 March 2018 Resolved
Remove water from stern void.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2018
Resolved 19 March 2018
Resolution: Water removed found cracks in bulkhead issued 835 to make repairs.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 15 March 2018 Resolved
Prove proper operation of stern void bilge alarm.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 March 2018
Resolved 20 March 2018
Resolution: Verified proper operation
Navigation › Piloting/Steering › Marine Charts
Issued 15 March 2018 Resolved
Provide updated charts.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 15 March 2018
Resolved 20 March 2018
Resolution: Updated Charts onboard
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 15 March 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 15 April 2018
Resolved 21 June 2018
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 March 2018 Resolved
Drills not conducted due to the fire main main being contaminated with oil. Flush system and conduct drills tothe satisfaction of attending MI.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 20 March 2018
Resolved 22 March 2018
Resolution: Witnessed drills.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 December 2016 Resolved
Vessel does not have a VHF radio on emergency power. 47 CFR 80.905(a)(3).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 29 December 2016
Resolution: Witnessed operation of VHF radio on emergency power.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 28 December 2016 Resolved
Fire detection system has not been tested. 46 CFR 181.05-5 (Old T).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 29 December 2016
Resolution: Witnessed operation of fire detection system.
Fire Fighting › Fire Hoses › Condition
Issued 28 December 2016 Resolved
01 fire hoses has a hole. 46 CFR 181.15-10 (Old T).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2017
Resolved 29 December 2016
Resolution: Verified replacement of bad hose.

Recorded names · 1

M/V GEORGE EDWARD (2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.