Records from 1982 to 2012. Most recent: inspection, 7 May 2012.
Inspection history · 56
7 May 2012
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4304286
16 January 2012
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4313258
10 January 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4222039
20 December 2010
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3923999
12 August 2008
Deficiency Check · COC-MODU Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3297672
18 October 2006
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2803186
18 July 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2731318
10 January 2006
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2569406
5 November 2004
COC-MODU Renew
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2235323
25 March 2004
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2031222
18 February 2004
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2023341
11 February 2004
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2005253
25 January 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1735314
14 November 2002
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1709046
27 January 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481610
7 December 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075995
14 November 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376807
8 October 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1055224
1 December 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812491
17 November 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404875
17 December 1998
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1399010
16 November 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459455
7 July 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1128567
19 January 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1112019
16 January 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1111940
19 December 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1116516
2 December 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1422937
11 April 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 179979
4 April 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 86435
29 November 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413080
16 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1095481
22 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 158727
30 May 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 83091
1 December 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1385588
23 November 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 92726
15 December 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1149835
1 December 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411050
24 February 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 838007
11 February 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1162174
3 February 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1165454
27 January 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 851654
1 December 1993
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1471655
2 April 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 835247
8 February 1993
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1140499
2 February 1993
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 832052
19 January 1993
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1140491
2 December 1992
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 961358
18 May 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1254682
8 May 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379692
23 March 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1015097
13 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992907
13 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296836
10 May 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280421
11 January 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274178
22 October 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968902
29 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277458
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 16 January 2012
Resolved
The safe manning certificate requires 01 OS. Provide a valid Vanuatu certificate for an OS or AB. Ensure the same for the alternate crew. Code 0135.
Due 16 February 2012
Resolved 16 February 2012
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 16 January 2012
Resolved
The safe manning certificate requires 02 crew members to have Vanuatu Marine Radio Telephone Licenses currently there is only 01. Provide a valid Vanuatu Marine Radio Telephone License to meet Safe Manning. Ensure the same for the alternate crew. Code 0135.
Due 16 February 2012
Resolved 16 February 2012
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 16 January 2012
Resolved
Third party fire-fighting report calls out numerous deficiencies. Prove documentation showing all were repaired. Code 0720. Cite 46 CFR 109.223. Action 16a,c.
Due 30 January 2012
Resolved 25 January 2012
Documentation › Certificates/Documents › IOPP Certificate
Issued 16 January 2012
Resolved
IOPP certificate does not show the waste oil tank. Update IOPP certificate to show the waste oil tank. Code 0150.
Due 16 February 2012
Resolved 16 February 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 16 January 2012
Resolved
The operating instructions for the CO2 system refer to two #1 valves and two #2 valves. Update the instructions to eliminate the confusion on which valve to open for which space. Code 0725.
Due 16 February 2012
Resolved 7 March 2012
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 16 January 2012
Resolved
The rescue boat has not been released in at least six months. Unhook the rescue boat and conduct training on hooking the boat back up. Code 0615.
Due 16 February 2012
Resolved 16 February 2012
Fire Fighting › Means of Escape › Blocked
Issued 16 January 2012
Resolved
The means of escape from the thruster room is bolted shut. Provide proper means of escape from the thruster room. Code 0960.
Due 16 February 2012
Resolved 7 March 2012
Lifesaving › Launching Appliances › Winch Brake
Issued 20 December 2010
Resolved
Repair Bow limit switch on life boat #2.
Action required: 705 - Other - as specified
Resolved 24 February 2011
Resolution: Cleared per email from [name withheld] 24 Feb 2011.
Lifesaving › Lifebuoys › Size
Issued 20 December 2010
Resolved
Provide Bridge buoys for smoke life rings.
Action required: 705 - Other - as specified
Resolved 24 February 2011
Resolution: Cleared per email from [name withheld] 24 Feb 2011.
Fire Fighting › Fire Pumps › Arrangement
Issued 20 December 2010
Resolved
Repair/Replace fire pump #2 prior to drilling operations.
Action required: 705 - Other - as specified
Resolved 24 February 2011
Resolution: Cleared per email from [name withheld] 24 Feb 2011.
Communications › Alarms/Indicators › General Alarm
Issued 20 December 2010
Resolved
Repair purge alarm on drill floor.
Action required: 705 - Other - as specified
Resolved 20 December 2010
Resolution: Corrected while still onboard.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 12 August 2008
Resolved
Holes were located in aft bulkhead by centerline water tight door and starboard side. Repair bulkhead in order to maintain "A" structural fire protection.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 August 2008
Resolved 20 August 2008
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 12 August 2008
Resolved
Adjust or renew air supply relief valves in both life boats.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2008
Resolved 20 August 2008
Lifesaving › Lifeboat › Hull
Issued 12 August 2008
Resolved
Provide manufacturers' verification that apparent damage to both life boat hulls (iwo of transom where aft falls release mechanism support brace attaches to hull) are satisfactory for intended service.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 August 2008
Resolved 20 August 2008
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 18 October 2006
Resolved
Prove derrick camera and top drive console shutdown or alarm upon loss of purged air.
Condition: Unknown
Due 26 November 2006
Resolved 29 October 2006
Resolution: Unit proved operational by service tech.
Electrical › Electrical Distribution System (service)
Issued 11 February 2004
Resolved
Provide covers for junction boxes located in vessel's galley. LEGACY COMPONENT DESC: Junction Box
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 18 February 2004
Resolution: Received digital photos of cover installed on junction boxes.
Accommodation/Occupational Safety › Cooking Systems
Issued 11 February 2004
Resolved
Conduct general cleaning around and behind galley equipment.
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 18 February 2004
Resolution: Received digital photos of areas noted after cleaning.
Engineering › Lubricating Oil Storage/Transfer System
Issued 11 February 2004
Resolved
Make proper repairs to drill water pipe in dry bulk tank farm. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 18 February 2004
Resolution: Received digital photos of repairs to drill water pipe.
Pollution Prevention/Response › Prevention Equipment
Issued 11 February 2004
Resolved
Make proper repairs to plastic MSD pipe. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 18 February 2004
Resolution: Received digital photos of repairs to MSD.
Lifesaving › Lifebuoys
Issued 11 February 2004
Resolved
Provide bracket for waterlights in way of #2 lifeboat. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 18 February 2004
Resolution: Received digital photo of newly installed waterlight holder.
Fire Fighting › Structural - A Class Divisions
Issued 11 February 2004
Resolved
Properly install areas of loose A-60 insulation in main machinery space. LEGACY COMPONENT DESC: Decks - Machinery Spaces
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 25 March 2004
Resolution: Received digital photos from vessel rep showing insulation properly installed.
Lifesaving › Lifeboat
Issued 11 February 2004
Resolved
Replace retroreflective tape on both lifeboats as needed. LEGACY COMPONENT DESC: Markings
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 25 March 2004
Resolution: Received statement from vessel rep stating that the retro reflective tape had been renewed.
Lifesaving › Lifebuoys
Issued 11 February 2004
Resolved
Replace retroreflective material on all lifebuoys.
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 25 March 2004
Resolution: Received statement from vessel rep stating that retro reflective tape had been renewed.
Electrical › Lighting (emergency)
Issued 11 February 2004
Resolved
Make emergency light in the emergency generator room operational. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 18 February 2004
Resolution: Received statement from OIM that light had been properly repaired.
Pollution Prevention/Response › Prevention Equipment
Issued 14 November 2002
Resolved
Properly mount and provide containment for fueling station for the cementing unit.
Due 14 December 2002
Resolved 9 December 2002
Pollution Prevention/Response › Prevention Equipment
Issued 14 November 2002
Resolved
Provide oil transfer procedures prior to conducting oil transfers.
Action required: 703 - Prior to bunkering operations
Resolved 9 December 2002
Electrical › Lighting (service)
Issued 14 November 2002
Resolved
Repair broken E.Y.S. fitting on the #2 bug blower switch located on the drill floor. LEGACY COMPONENT DESC: Switch
Due 14 December 2002
Resolved 9 December 2002
Construction/Loadline › Penetrations
Issued 14 November 2002
Resolved
Crop and renew damaged exhaust ventilator located port side aft for the thruster room. LEGACY COMPONENT DESC: Pipe Flange
Due 14 December 2002
Resolved 9 December 2002
Engineering › Generator (propulsion/auxiliary-electric)
Issued 14 November 2002
Resolved
Provide [name withheld] evidence that the #1 generator jacket water pump has been renewed.
Due 14 December 2002
Resolved 9 December 2002
Lifesaving
Issued 14 November 2001
Resolved
crop and renew electrical riser/transit outboard (2ea) of each mud pump, air winch support by mud pumps, coming that supports catwalk stantions outboard of port mud pump, steps and landing fwd pipe rack.
Condition: Unknown
Due 14 November 2001
Resolved 14 November 2001
Lifesaving
Issued 14 November 2001
Resolved
Provide U1A data sheet and NDT report on the 2 drill floor air receivers toOCMI Morgan City.
Condition: Unknown
Due 14 November 2001
Resolved 14 November 2001
Lifesaving
Issued 14 November 2001
Resolved
Renew expired lifeboat drinking water in both boats.
Condition: Unknown
Due 14 November 2001
Resolved 14 November 2001
Documentation
Issued 14 November 2001
Resolved
provide radio operator license.
Due 7 January 2002
Resolved 20 May 2002
Electrical
Issued 17 November 1999
Resolved
PROVIDE DOCUMENTATION ON LOAD TEST FOR EMERGENCY BATTERIES.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Fire Fighting
Issued 17 November 1999
Resolved
PROVIDE FIRE DOOR FOR GALLEY.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Unknown
Issued 16 November 1998
Resolved
REPLACE CRACKED GLASS ON PORT CRANE OPERATOR'S STATION.
Condition: Unknown
Due 19 November 1998
Resolved 9 December 1998
Lifesaving
Issued 16 November 1998
Resolved
CONDUCT OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR UNDER A LOAD OF 110% OR AN ALTERNATE TEST ACCEPTABLE TO THE COGNIZANT OCMI.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Lifesaving
Issued 16 November 1998
Resolved
RE-REAVE INBOARD WINCH DRUM FOR LIFEBOAT #2, REPLACE FORWARD WINDOW ON LIFEBOAT #1.
Condition: Unknown
Due 22 November 1998
Resolved 9 December 1998
Fire Fighting
Issued 2 December 1997
Resolved
CORRECT DEFICIENCIES FROM GULF WIDE SAFETY SYSTEMS REPORT DTD 11/20/97, ie RECHARGE #1 CYLINDER IN ENGINE ROOM HALON SYSTEM.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Fire Fighting
Issued 2 December 1997
Resolved
PROVIDE FIREMANS PANTS OR LONG BOOTS FOR FIRE SUIT IN BREEZEWAY._x001C_
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Engineering
Issued 2 December 1997
Resolved
PROVE OPERATION OF REMOTE VENTILATION SHUTDOWN OUTSIDE ENGINE ROOM (PORT AND STARBOARD SIDES) FOR ENGINE ROOM VENTILATION. THEY ARE STICKING ALSO LABEL THE STARBOARD SHUTDOWN._x001C_
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 2 December 1997
Resolved
IMPLEMENT NEW 46 CFR 108 AND 109 REQUIREMENTS.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Engineering
Issued 2 December 1997
Resolved
PROVE OPERATION OF REMOTE VENTILATION SHUTDOWN IN TOOLPUSHERS OFFICE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Fire Fighting
Issued 2 December 1997
Resolved
PUT CHAINS ON NOZZLE TIPS OF BOTH FIRE STATIONS ON HELO DECK.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 2 December 1997
Resolved
REPLACE OR HAVE CLASS SOCEITY SURVEY DAVIT BLOCKS ON BOTH LIFEBOATS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 2 December 1997
Resolved
REPLACE ALL BAD SURVIVAL LIGHTS ON LIFE PRESERVERS.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Lifesaving
Issued 2 December 1997
Resolved
PROVIDE 3 PARACHUTE FLARES FOR RIG.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 2 December 1997
Resolved
REPAIR INTERIOR LIGHTS FOR NO # 1 LIFEBOAT.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 2 December 1997
Resolved
REPLACE PAINTED GASKET IN WATERTIGHT DOOR BETWEEN AIR COMPRESSOR ROOM AND BULK TANK ROOM.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Electrical
Issued 2 December 1997
Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR AUTOMATIC STARTUP.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 2 December 1997
Resolved
PROVE OPERATION OF FOG SIGNAL.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Lifesaving
Issued 29 November 1996
Resolved
HYDROSTATICALLY TEST AIR CYLINDERS IN ALL LIFEBOATS.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Lifesaving
Issued 29 November 1996
Resolved
RENEW WASTED LIFEBOAT STOP BLOCK SUPPORTS ON ALL LIFEBOATS.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Fire Fighting
Issued 29 November 1996
Resolved
MAKE REPAIRS AND/OR RENEW FIRE MAIN SYSTEM TO THE SATISFACTION OF THE CLASSIFICATION SOCIETY. RENEW FIRE MONITOR SUPPORT ON HELIPORT AND PROVE PROPER OPERATION OF HELIPORT FIRE MONITORS.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Electrical
Issued 1 December 1994
Resolved
REWIRE OR REMOVE EXPLOSION PROOF LIGHT OVER PORT MUDPIT. WIRING GOES THROUGH WATERTIGHT DOOR, HARDWIRE TO RECEPTACLE OR ADD EXPLOSION PROOF TYPEPLUG.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Lifesaving
Issued 1 December 1994
Resolved
REPAIR FORWARD LIMIT SWITCH ON #1 LIFEBOAT.
Condition: Unknown
Due 1 December 1994
Resolved 1 December 1994
Lifesaving
Issued 1 December 1994
Resolved
INSTALL SPARE BATTERIES IN FIREMAN'S OUTFITS.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Lifesaving
Issued 1 December 1994
Resolved
REPAIR EXHAUST FLAPPER ON LIFEBOAT #1 WHERE SPRING DOES NOT HOLD FLAPPER TIGHT.
Condition: Unknown
Due 1 December 1994
Resolved 1 December 1994
Electrical
Issued 1 December 1994
Resolved
PROVE PROPER OPERATION OF #2 GENERATOR LOW LUBE OIL PRESSURE SHUTDOWN.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 1 December 1994
Resolved
REPLACE NON-EXPLOSION PROOF JUNCTION BOXES AT FOLLOWING LOCATIONS IN SACK AREA: OVERHEAD IN MIDDLE OF SACK ROOM AND STBD SIDE UNDER PIPE RACK OVER MUDPIT.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 1 December 1994
Resolved
REPLACE BURNT OUT BULB ON EMERGENCY LIGHT PORT SIDE UPPER LEVEL AT LIFEBOAT.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 1 December 1994
Resolved
REPLACE BURNT OUT BULB ON EMERGENCY LIGHT BETWEEN ROOMS #5 AND #6 IN QUARTERS HALLWAY.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 1 December 1993
Resolved
REPAIR #2 GENERATOR LUBE OIL SHUTDOWN AND PROVE PROPER OPERATION.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Accommodation/Occupational Safety
Issued 1 December 1993
Resolved
INSTALL MISSING STROGBACK ON SHIP'S SERVICE AIR RECEIVER MANHOLE COVER IN COMPRESSOR ROOM.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Accommodation/Occupational Safety
Issued 1 December 1993
Resolved
FREE-UP AND PROVE PROPER OPERATION OF REMOTE EMERGENCY VENTILATION AND FUELTRANSFER PUMP SHUTDOWNS.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Electrical
Issued 1 December 1993
Resolved
PROVIDE TACHOMETER TO TEST ALL MAIN GENERATOR AND EMERGENCY GENERATOR OVERSPEED SHUTDOWNS.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Accommodation/Occupational Safety
Issued 1 December 1993
Resolved
INSTALL ASME APPROVED RELIEF VALVES WITH PROPER MARKING OF PRESSURE AT OR LESS THAN 100 PSI ON POTABLE AND SANITARY WATER TANKS.
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Documentation
Issued 2 April 1993
Resolved
SUBMIT REVISIONS TO OPERATING MANUAL TO MSO CORPUS CHRISTI PER LETTER OF 02APR93.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Documentation
Issued 2 December 1992
Resolved
SUBMIT OPERATING MANUAL TO [name withheld], TEXAS, TO REVIEW FOR COMPLIANCE WITH 46 CFR 109.121.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Unknown
Issued 2 December 1992
Resolved
TEST FOUR AIR RECEIVER RELIEF VALVES AND REPORT RESULTS OF TEST TO [name withheld], TEXAS
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Unknown
Issued 2 December 1992
Resolved
REPAIR/CALIBRATE GAS DETECTOR SYSTEM.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Electrical
Issued 2 December 1992
Resolved
ELIMINATE IMPROPER ELECTRICAL WIRE (SPLICE) REPAIR IN AFT DRILLING FP_x001C_ DROVIDE CLASS SOCIETY REPORT OF PROPER OPERATION OF GENERATOR AND OVERSPEEDCONTROL.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Unknown
Issued 2 December 1992
Resolved
REPAIR/ADJUST FOUR DRYBULK RELIEF VALVES TO RELIEVE AT OR BELOW 40 PSI.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Documentation
Issued 2 December 1992
Resolved
PROVIDE CURRENT DOCUMENTATION FOR RADIO TELEPHONY CERTIFICATE AND CLASSIFICATION CERTIFICATES, THE ONES ON BOARD VESSEL EXPIRED 01DEC92.
Condition: Unknown
Due 6 January 1993
Resolved 6 January 1993
Documentation
Issued 2 December 1992
Resolved
PROVIDE DOCUMENTATION OF LIFE BOAT WEIGHT TEST, AND PRESSURE VESSELS INTERNAL EXAMINATION, CONDUCTED AT THE DRYDOCK PERIOD.
Condition: Unknown
Due 7 January 1993
Resolved 7 January 1993
Accommodation/Occupational Safety
Issued 2 December 1992
Resolved
INSTALL CLOSING PANELS/DEVICES ON DECK EXHAUST VENTILATION DUCTS.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Unknown
Issued 2 December 1992
Resolved
REPAIR BROKEN SIGHT GLASS ON HYDRAULIC OIL TANK IN GENERATOR ROOM.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Unknown
Issued 2 December 1992
Resolved
MAKE PERMANENT REPAIRS TO WASTE OIL PUMP REMOTE SHUT DOWN.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Documentation
Issued 2 December 1992
Resolved
PROVIDE FIRE FIGHTING SERVICE REPORT CONDUCTED FOR THIS VESSEL.
Condition: Unknown
Due 6 January 1993
Resolved 6 January 1993
Electrical
Issued 2 December 1992
Resolved
INSTALL PROPER COVER ON ELECTRICAL JUNCTION BOX IN STARBOARD CRANE CAB.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Unknown
Issued 2 December 1992
Resolved
MAKE PERANENT REPAIRS TO HYDRAULIC LEAK AND CLEAN UP EXCESS OIL ON TOP OF RESEVOIR.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Unknown
Issued 2 December 1992
Resolved
CLEAN EXCESSIVE HYDRAULIC OIL LOCATED INSIDE STARBOARD CRANE CAB.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Electrical
Issued 2 December 1992
Resolved
JUNCTION BOX ON AFT DRILL FLOOR REQUIRES (E.Y.S.) PLUG.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Electrical
Issued 2 December 1992
Resolved
ELIMINATE IMPROPER ELECTRICAL WIRE (SPLICE) REPAIR IN AFT DRILLING FLOOR AREA.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Construction/Loadline
Issued 11 January 1983
Resolved
PROVIDE DRAWINGS APPROVED BY USCG DISTRICT EIGHT (MMT) FOR HATCH INSTALL- ATION AND COMPLY WITH ANY COMMENTS RECEIVED.
Condition: Unknown
Due 11 January 1983
Resolved 11 January 1983
Construction/Loadline
Issued 11 January 1983
Resolved
STENCIL SUBDIVISION BULKHEAD WATERTIGHT DOORS: KEEP CLOSED WHEN UNDER TOW.
Condition: Unknown
Due 11 January 1983
Resolved 11 January 1983
Unknown
Issued 11 January 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL BILL BAILEY, DN644637.
Condition: Unknown
Due 11 January 1983
Resolved 11 January 1983
Construction/Loadline
Issued 11 January 1983
Resolved
IN WAY OF NEW HATCH ON PORT MAIN DECK, REPAIR UNDERDECK LONGITUDINALS IN STORAGE ROOM.
Condition: Unknown
Due 11 January 1983
Resolved 11 January 1983
Electrical
Issued 29 September 1982
Resolved
(REQUIREMENT 1 CONTINUED) ACCEPTED.
Condition: Unknown
Due 29 September 1982
Resolved 29 September 1982
Unknown
Issued 29 September 1982
Resolved
HOOK LOAD IS RESTRICTED TO 250 TONS (500,000 LBS) UNTIL THE ADDITIONAL INFORMATION REQUESTED BY EIGHT COAST GUARD DISTRICT (MMT) IS REVIEWED AND
Condition: Unknown
Due 29 September 1982
Resolved 29 September 1982
Electrical
Issued 29 September 1982
Resolved
PROVIDE APPROVED DRAWINGS AND COMPLY WITH ALL COMMENTS ON APPROVAL LETTERS FOR THE FOLLOWING SYSTEMS (A) ELECTRICAL ONE LINE, (B) PROFESSIONAL
Condition: Unknown
Due 29 September 1982
Resolved 29 September 1982
Electrical
Issued 29 September 1982
Resolved
(REQUIREMENT 2 CONTINUED) ENGINEERS STAMPED DRAWINGS OF THE INDUSTRIAL SYSTEMS.
Condition: Unknown
Due 29 September 1982
Resolved 29 September 1982