MAURY USCG vessel records Sign in
← All vessels

SIR GAWAIN

SIR GAWAIN is a 1974 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1981, most recently in February 2026, along with 53 deficiencies, 1 operational control and 2 casualty investigations between 2016 and 2017.

Records from 1981 to 2026. Most recent: inspection, 27 February 2026.

Built
1974
Last inspected
27 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ3022
Flag
UNITED STATES
367110450
Maury page id
psix-48005

Inspections, by type

…with no type recorded18
Years with a record 41 calendar years (1981–2026)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)94.0 ft × 25.0 ft × 2.8 ft
Registered tonnagegross 76 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIVERSAL IRON WORKS INC · HOUMA, LA, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALVESTON, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 24 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ3022MMSI 367110450 · active · compulsorily equipped · granted 2 December 2016, expires 2 December 2026
WDD2065MMSI 367110450 · expired · compulsorily equipped · granted 29 April 2006, cancelled 2 July 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDA3681MMSI 366801070 · expired · compulsorily equipped · granted 21 February 2001, cancelled 23 April 2011 · licensed under a name not among this hull’s recorded names (not shown)
WYT8668MMSI not assigned · expired · compulsorily equipped · granted 23 September 1998, cancelled 7 March 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 12

Inspection history · 74

27 February 2026 COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8317618
13 March 2025 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8093181
27 February 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8092687
25 March 2024 In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7884646
25 February 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7869744
14 February 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7636856
18 January 2023 Damage Survey · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7623321
10 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7447630
24 February 2021 COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7145668
2 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7104870
16 March 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6927569
10 March 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6924018
14 December 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6874930
12 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6661381
22 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6359430
5 January 2018 Drydock Exam · Examination of Repairs · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6344465
21 March 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6153255
9 March 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6101945
19 October 2016 Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6025910
18 October 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6032751
1 March 2016 DAPI Audit · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5820486
28 September 2011 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4156602
22 January 2010 Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3667914
7 May 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3469434
12 December 2007 Internal Structural Exam · Hull Examination · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3134900
23 April 2007 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2913990
28 February 2007 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2879427
25 January 2007 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2861717
31 January 2006 Examination of Repairs · Deficiency Check · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2576544
16 February 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2293531
16 September 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2197577
10 May 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2064263
29 April 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2055195
5 February 2003 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1740087
13 January 2003 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1729774
20 December 2002 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1729548
28 February 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1490110
9 March 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059753
1 February 2001 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417210
20 October 2000 Permit to Proceed · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1463619
19 October 2000 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 150339
24 March 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376085
29 April 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447941
2 April 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375340
30 September 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409768
25 November 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 132286
31 July 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422723
4 March 1996 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377668
11 July 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409321
6 September 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 865375
17 August 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466362
30 August 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1135206
19 August 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354440
18 March 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461502
15 September 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 25935
27 August 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393868
11 February 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 20279
26 December 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 646269
3 September 1991 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 937539
4 September 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914519
10 April 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232785
6 September 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199696
12 September 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349761
9 September 1987 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316322
2 April 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326717
17 February 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016536
29 January 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310287
11 September 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313412
20 September 1985 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300226
19 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976700
26 September 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965110
6 January 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277347
15 January 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273038
16 January 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271174

Deficiency record · 53

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 March 2024 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. MI observed the installed lower life float to be in poor condition. The vivid red-orange color was found faded and exterior surface damage i.e. cracking and buoyant material separation was found in several areas. The lower life float is to be replaced with survival craft in good working order and of adequate capacity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 26 March 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 March 2024 Resolved
An interconnected detection and alarm system must: Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. MI's found a smoke detector wrapped in a plastic shower cap in the main cabin by the base of the ladder leading to the operating station, and an interconnected smoke detector was missing in the engine room.
Action required: 10 - Deficiency Rectified
Resolved 25 March 2024
Resolution: Plastic cover removed and an interconnected smoke detector was installed in the engine room (tested satisfactory).
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 25 March 2024 Resolved
The Watchmen monitoring device must: Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards. System did not function properly when tested.
Action required: 10 - Deficiency Rectified
Resolved 25 March 2024
Resolution: The watchman system was troubleshot, reset and tested satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 March 2020 Resolved
Vessesl that operate in salt water must be examined in accordance with the intervals set forth in Table 91.40-3(a) of this section. When Table 91.40-3(a) indicateds a 2.5 year examination interval, it menas a vessel must undergo two examinations within any five year period. No more than three years may elapse between any two examinations. Vessel failed to meet the required dry dock dates noted on its Certificate of Inspection. Vessel is restricted from operations until a dry dock examination is completed by a USCG Marine Inspector. 46 CFR 91.40-3(a) 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2020
Resolution: Completed satisfactory drydock.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 April 2019 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Vessel did not have adequate lighting in machinery space to allow escape to the emergency escape route. Vessel is required to install adequate lighting to the satisfaction of the attending marine inspector. 46 CFR 183.432(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 16 April 2019
Resolution: Verified adequate emergency lighting was added to the engine room escape route.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 April 2019 Resolved
Each vessel must be marked as required by part 67, subpart I, of this chapter. Vessel did not have home port marked on the stern of the vessel. Vessel is required to mark the stern of the vessel with the home port.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2019
Resolved 16 April 2019
Resolution: Home port name has been added to the stern.
Lifesaving › Lifefloat › Serviceable
Issued 1 March 2016 Resolved
Both life floats has worn and deteriorated materials to include grab lines. Replace or make serviceable. Correct prior to carrying pax or conducting operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2016
Resolved 10 March 2016
Resolution: O/O replaced two damaged life floats with two new 15 man approved life floats.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 1 March 2016 Resolved
Water pump housing and connection to exhaust manifold has corroded and developed a hole which allows fresh water to leak out. Make repairs to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 10 March 2016
Resolution: Both MDE had there corroded cooling water pump housing and holed exhaust manifold replaced with new item (replaced in kind). All tested sat.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 1 March 2016 Resolved
All fuel tank topside goose neck vent flame screens are clogged. Remove and clean or replace as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 10 March 2016
Resolution: O/O replaced flame screens on all fuel tank vents.
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 1 March 2016 Resolved
Ports sided fuel tank gooseneck vent is not properly aligned over its spill containment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 10 March 2016
Resolution: Vent containment repaired.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 March 2016 Resolved
Portside life ring's bossing line is not properly attached.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 10 March 2016
Resolution: Life ring replaced with new approved life ring.
Deck/Cargo › Ballast › Piping
Issued 1 March 2016 Resolved
Ballast tank manifold piping is leaking excessively into the engine room bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 10 March 2016
Resolution: Newly constructed ballast tank manifold was installed on board and NDT'd, all tested sat.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 1 March 2016 Resolved
Main fuel supply pipeline is holed and improperly repaired with soft patch. Replace fuel pipeline with approved pipe and properly NDT to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 10 March 2016
Resolution: Verified replacement of damaged section of pipeline and witnessed satisfactory NDT. All sat.
Documentation › Logs/Records › Logbook (official)
Issued 7 May 2009 Resolved
Log Man Overboard, Abandon Ship, and Fire Drills and monthly EPIRB checks.
Action required: 705 - Other - as specified
Resolved 13 May 2010
Resolution: Vsl is using a stamp to track drills and safety equipment maintenance.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 7 May 2009 Resolved
Maintain Lifesaving Equipment Maintenance Records
Action required: 705 - Other - as specified
Resolved 13 May 2010
Resolution: Vsl is using a stamp to track drills and safety equipment maintenance.
Engineering › Diesel Engine (auxiliary) › Block
Issued 3 April 2008 Resolved
Renew and/or Repair Port Generator expansion tank at the cap.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 4 April 2008
Resolution: Expansion tank renewed.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 3 April 2008 Resolved
Install lock on switchboard panel face, install dielectric matte in front of switchboard, and demonstrate power availability lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 4 April 2008
Resolution: Screws installed, matte installed and lights are working
Communications › Radio Communications › Emergency Source of Power
Issued 3 April 2008 Resolved
Demonstrate Radio's on Emergency Power.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 4 April 2008
Resolution: Radio''s demonstrated on battery power.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 3 April 2008 Resolved
Install "Blanks" in Panel Boards as necessary through-out ship.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 4 April 2008
Resolution: Blanks installed.
Stability › Watertight Integrity › General
Issued 3 April 2008 Resolved
Install "Rubber Gaskets" in all watertight closures.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 4 April 2008
Resolution: Rubber gaskets installed and doors adjusted.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 3 April 2008 Resolved
Provide current compass deviation table and post at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 4 April 2008
Resolution: Compass deviation table posted.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 3 April 2008 Resolved
Provide Emergency Broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 4 April 2008
Resolution: Posted placard.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 April 2008 Resolved
Install Life Jacket donning placard for the 01 deck.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 4 April 2008
Resolution: Posted placard.
Operations/Management › Drills/Instruction › Not Conducted
Issued 3 April 2008 Resolved
Conduct all Drills and log, attending Marine Inspector will run all drills to determine proficiency.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 4 April 2008
Resolution: Drills conducted all sat.
Documentation › Logs/Records › Logbook (official)
Issued 3 April 2008 Resolved
Log all entries; Crew list, Passenger list, and prior to leaving port.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 4 April 2008
Resolution: New log started and Crew Listed.
Electrical › Electric Generation Source (service) › Generator
Issued 23 April 2007 Resolved
The starboard generator was due for an armature cleaning.
Due 31 May 2007
Resolved 2 May 2007
Operations/Management › Drills/Instruction › Abandon Ship
Issued 23 April 2007 Resolved
The required quarterly drills were not properly documented.
Action required: 705 - Other - as specified
Resolved 2 May 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 January 2006 Resolved
Correct short in stern light assembly or renew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2006
Resolution: Stern Light assembly renewed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 31 January 2006 Resolved
Provide bilge alarm for rudder compartment
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2006
Stability › Watertight Integrity › General
Issued 31 January 2006 Resolved
Correctly seal forward engine room bulkhead wire penetrations
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2006
Engineering › Fuel Oil Service System › Filter
Issued 31 January 2006 Resolved
Remove all petcocks from fuel system
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2006
Electrical › Electric Generation Source (service) › Generator
Issued 31 January 2006 Resolved
Make proper repairs to chaffed wires in port generator wiring harness
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 31 January 2006 Resolved
Label all lifesaving equipment with full vessel name
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 31 January 2006 Resolved
Provide proper OSHA approved rescue harness
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 January 2006 Resolved
Demonstrate all drills (fire/abandon ship/man overboard) to the satisfaction of attending marine inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2006
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 31 January 2006 Resolved
Provide dogging wrench for engine room escape trunk
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2006
Engineering › Fuel Oil Service System › Piping
Issued 31 January 2006 Resolved
Install double hose clamps throughout vessel's piping systems.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2006
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 31 January 2006 Resolved
Label location of stove/range disconnect at range.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2006
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 31 January 2006 Resolved
Demonstrate successful air test (1.5 psi) on port cargo fuel tank bulkhead insert
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2006
Documentation › Certificates/Documents
Issued 29 April 2004 Resolved
Provide FCC Radio Operator permit no later than 29 May 2004. LEGACY COMPONENT DESC: FCC Radio Operator Permit
Action required: 705 - Other - as specified
Due 29 May 2004
Resolved 27 May 2004
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 27 February 2003 Resolved
INSTALL BATTERY BOX COVER FOR BATTERY IN ENGINEROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2003
Resolved 27 February 2003
Navigation › Piloting/Steering › Compass Deviation Table
Issued 27 February 2003 Resolved
PROVIDE 2002 LIGHT LIST AND ALL ASSOCOATED CORRECTIONS.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2003
Resolved 27 February 2003
Fire Fighting › Fire Pumps
Issued 28 February 2002 Resolved
REPLACE FIRE PUMP DISCHARGE GAUGE WITH 100 PSI GAUGE. LEGACY COMPONENT DESC: GAUGE
Due 28 February 2002
Resolved 28 February 2002
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 February 2002 Resolved
PROVIDE ONE ADDITIONAL NOT UNDER COMMAND LIGHT.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2002
Resolved 28 February 2002
Construction/Loadline › Structures › Door
Issued 28 February 2002 Resolved
INSTALL GASKETS IN ALL WATER TIGHT DOORS.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2002
Resolved 28 February 2002
Engineering › Bilge Water Management System
Issued 28 February 2002 Resolved
REMOVE ALL OILY WASTES IN ENGINE ROOM BILGES. LEGACY COMPONENT DESC: WASTE OIL IN BILGES
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2002
Resolved 28 February 2002
Engineering
Issued 1 February 2001 Resolved
Demonstrate proper operation of starboard main engine shutdown in wheelhouse to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Electrical
Issued 1 February 2001 Resolved
Demonstrate proper operation of engine room blower remote shutdown to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 20 October 2000 Resolved
Make permanent repairs to hull and superstructure to the satisfaction of attending inspector.
Condition: Unknown
Due 20 October 2000
Resolved 20 October 2000
Lifesaving
Issued 24 March 2000 Resolved
DEMONSTRATE PROPER OPERATION OF BOTH ELECTRICAL GENERATOR OVERSPEED PROTECTION DEVICES, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Lifesaving
Issued 24 March 2000 Resolved
REWIRE BRIDGE MAIN ENGINE AND BILGE ALARM SYSTEM TO ALLOW EACH ADDITIONAL INCOMING ALARM TO SOUND WARNING BUZZER AND LIGHT ALARM INDICATOR, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Engineering
Issued 24 March 2000 Resolved
PROVIDE EMERGENGY MAIN ENGINE SHUTDOWNS AT THE PILOT HOUSE CONTROL STATION,TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Documentation
Issued 17 August 1994 Resolved
PROVIDE ONBOARD A VALID FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 17 August 1994
Resolved 17 August 1994

Casualty record · 2

18 October 2016Routine · role: Involved in a Marine Casualty · activity 6032751
21 March 2017Routine · role: Transiting Vicinity of Primary Subject · 1 injured · activity 6153255
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEAOPS 1 (2016–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.