MAURY USCG vessel records Sign in
← All vessels

WMT

WMT is a 1983 offshore supply vessel. The Coast Guard has recorded 85 inspections since 1983, most recently in March 2025, along with 56 deficiencies, 1 operational control and 2 casualty investigations between 2011 and 2022.

Records from 1983 to 2025. Most recent: inspection, 24 March 2025.

Built
1983
Last inspected
24 March 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM8672
Flag
UNITED STATES
368245430
Maury page id
psix-55295

Inspections, by type

…with no type recorded11
Years with a record 38 calendar years (1983–2025)
The 85 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)123.9 ft × 28.1 ft × 6.8 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderQUEEN CRAFT · PANAMA CITY, FL, UNITED STATES · built 1983
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 July 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM8672MMSI 368245430 · active · compulsorily equipped · granted 22 March 2022, expires 22 March 2032
WDE5081MMSI 367361780 · cancelled · compulsorily equipped · granted 19 May 2018, cancelled 16 September 2021
WRC4038MMSI 366710000 · expired · compulsorily equipped · granted 19 February 1998, cancelled 19 July 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 10

Inspection history · 85

24 March 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8087301
19 February 2025 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8060339
4 April 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7890115
11 April 2023 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7635298
15 February 2023 Appeal
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7637949
10 February 2023 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7624692
27 December 2022 Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7613863
10 August 2022 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7530225
19 April 2022 Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7433667
31 March 2022 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7404064
9 November 2021 Construction Oversight
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7345347
9 September 2021 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7308565
1 September 2021 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7307572
2 June 2021 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7213291
22 February 2021 Drydock Exam · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7144026
12 March 2020 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6928437
6 February 2019 Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6622436
28 January 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6617160
15 November 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6307100
2 June 2017 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6167258
23 January 2017 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6073477
6 January 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6071661
11 January 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5794937
14 June 2012 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4344621
5 August 2011 Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4105710
1 August 2011 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4103127
1 August 2011 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4105191
9 December 2010 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3904563
10 September 2010 Annual Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3847068
18 December 2008 Internal Structural Exam · Hull Examination · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3377561
6 December 2008 Permit to Proceed
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3375403
12 June 2008 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3234806
6 June 2007 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3026612
14 May 2007 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2999772
7 September 2006 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2772018
20 April 2005 Hull Examination · Re-Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2338980
1 July 2004 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2117788
29 June 2004 Annual Inspection · Internal Structural Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2115996
22 June 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2106628
19 June 2003 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1820885
22 April 2003 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1782606
18 June 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1632378
9 April 2002 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1602756
6 November 2001 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1466811
20 September 2001 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1410655
24 August 2000 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1424976
8 November 1999 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1469615
3 September 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785095
24 June 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1430707
27 August 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400835
14 November 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446559
3 November 1997 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1422926
16 April 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1102779
18 March 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1404328
25 November 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 132286
27 July 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1394579
27 June 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1355857
15 September 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 40662
14 July 1995 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459952
27 July 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414353
7 July 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356713
10 August 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 847359
15 July 1993 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 847097
19 March 1993 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 833952
25 August 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457061
4 September 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1308066
30 August 1991 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1254190
9 August 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939741
9 August 1991 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1250849
18 March 1991 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239550
29 August 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925822
27 September 1989 Examination of Repairs · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1328671
24 September 1989 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1329059
2 September 1989 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1039389
23 February 1989 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041623
17 August 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037518
5 May 1988 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1200529
20 August 1987 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1338797
16 August 1986 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 989127
7 January 1986 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1303280
13 August 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986388
5 February 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 979276
13 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282155
7 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965123
16 August 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969762

Deficiency record · 56

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 March 2025 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. WTB at frame 16 is not watertight. Make bulkhead penetrations watertight to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2025
Resolved 14 April 2025
Resolution: Vessel sealed WTB.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 24 March 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Galley ventilation hood fan and ducting were coated in grease. Filter was not present for galley range ventilation assembly. Clean hood assembly, fan, and ducting from excess grease and install filter to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2025
Resolved 14 April 2025
Resolution: Vessel cleaned range duct and installed new grease filter.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 April 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Unless otherwise stated in this section, each item of equipment carried, whether required under this section or not, must be secured by lashings, stored in lockers, compartments, brackets, or have equivalent mounting or storage arrangements that do not: (1) Reduce survival craft capacity; (2) Reduce space available to the occupants; (3) Interfere with launching, recovery, or rescue operations; or (4) Adversely affect seaworthiness of the survival craft. Port upper and both starboard life floats securing straps for pendants, lifelines, and float net were wasted beyond repair. Vessel operator has a spare (12) person life float that will be installed on the port side with a (15) person life float. Float free link is a 21 or more persons. Vessel is restricted to 27 persons on board until life floats are serviced to satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 April 2024
Resolution: Vessel installed (1) 15 person, and (2) 22 person life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 April 2024 Resolved
The float-free link required by § 180.130(a)(1) must be: (1) Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant. Both life float stacks were missing manufacturer certification tag. Replace both float-free linkage assemblies to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 April 2024
Resolution: Float free links replaced and include (1) 11-20 person, and (1) 21 or more person.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 February 2023 Resolved
Submit Repair proposal for hull from frames 6-17 (Galley bilge/crew accommodation space) centerline from keel on both PORT/STBD sides. Repair for credit dry dock. 46CFR177.01-5
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 February 2025
Resolved 10 March 2025
Resolution: Satisfactory repairs completed at 2025 drydock. Ref. Misle Activity 8060339.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 April 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure. While underway, vessel crew observed the shaft from 01 of the vessel’s 04 main propulsion engines moving in and out of the vessel's stern tube. Diagnose shaft failure and submit comprehensive repair proposal to this office via e-mail for review.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2022
Resolution: Diagnosed shaft failure and submited comprehensive repair proposal to this office for review. Conducted SAT seatrial after repair and submiited objective evidence. See documents section (WMT EMAIL 4_20_2022.pdf & WMT Corrective Action final.pdf)
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 31 March 2022 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Public address speaker on aft deck not functional. Repair or replace and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 7 April 2022
Resolution: Vessel repaired speaker.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2022 Resolved
Vessel installed new engine control system. Limited DVTP/QFAs were provided on board but were not approved by MSC and did not represent the installed system (test procedures listed functions not installed and installation did not match referenced control box ports/functions). In accordance with CVC Policy 17-07, submit the following for review: (1) A limited QFA of the vessel’s propulsion engine control system (throttle), documenting system compliance to CVC Policy 17-07. The limited QFA should only consider loss of power to the control system. (2) A propulsion control drawing should be submitted with an installation/operational test protocol. This test protocol is an abridged document intended to show compliance with 46 CFR.184.620. Following MSC review, demonstrate power loss functions in accordance with approved procedures in the prsence of an attending USCG marine inspector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: MSC reveiw complete. Vessel demonstrated functions.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 3 September 2021 Resolved
Vessel was not issued a Load Line Exemption Certificate prior to an international voyage.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 17 September 2021
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 22 February 2021 Resolved
The inspected vessel does not have an installed Digital Selective Calling (DSC) radio function installed. Properly install radio function and provide proof.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 2 June 2021
Resolution: DSC function was operable on VHF radio.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 February 2021 Resolved
The door alarm at the operating station does not signal for the Engine Room and Lazerrete opening. Properly install door alarms to alert the operating station when these doors are open/closed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 2 June 2021
Resolution: Watertight door indicators for the generator room and lazarette were satisfactory at the operating station.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 January 2017 Resolved
life line worn
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 13 January 2017
Lifesaving › Lifefloat › Lifeline
Issued 6 January 2017 Resolved
worn
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 13 January 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 January 2017 Resolved
No servicing certificates
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 13 January 2017
Fire Fighting › Fire Main › Condition
Issued 6 January 2017 Resolved
fire main did not work
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 13 January 2017
Resolution: Fire main was blocked by growth. Vessel was put in dry dock and growth removed.
Construction/Loadline › Structures › Ventilators
Issued 10 September 2010 Resolved
Repair broken exhaust hanger, stbd generator at next hull exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2010
Resolved 18 December 2010
Communications › Public Address System › Loudspeaker
Issued 12 June 2008 Resolved
Install additional speaker in passenger area and repair speaker in berthing area
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 June 2008 Resolved
Install addtional emergency lighting for Gen room escape route.
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 30 June 2008
Construction/Loadline › Hull › Stringer
Issued 14 May 2007 Resolved
Repair fractured weld as marked between aft engine room bulkhead and starboard centerline stringer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2007
Stability › Unintentional Flooding › General
Issued 14 May 2007 Resolved
Repair frozen reach rod and valve for collision bulkhead.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 April 2005 Resolved
Provide (1) emergency light for Generator Room, (1) for Steering Compartment emergency escape, and (2) for both Engine Room emergency escapes.
Action required: 705 - Other - as specified
Due 21 May 2005
Resolved 21 April 2005
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 21 April 2005 Resolved
Provide ventilation louver for radio back-up battery.
Action required: 705 - Other - as specified
Due 21 May 2005
Resolved 21 April 2005
Engineering › Steering Gear System › Hydraulic Hose
Issued 29 June 2004 Resolved
Hoses worn through outer layer, replace hoses.
Action required: 705 - Other - as specified
Due 29 July 2004
Resolved 19 July 2004
Resolution: Received email photos of replacement hoses installed on steering system
Engineering › Diesel Engine (propulsion-reduction gear) › Waste Heat Recovery
Issued 29 June 2004 Resolved
Port inboard MDE expansion tank has soft patch in expansion tank, remove soft patch and properly repair.
Action required: 705 - Other - as specified
Due 29 July 2004
Resolved 29 June 2004
Resolution: Received email photo or permanent repair to expansion tank
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 June 2004 Resolved
Port side MDE exhaust piping hangers broken, repair hangers.
Action required: 705 - Other - as specified
Due 29 July 2004
Resolved 29 June 2004
Resolution: Received email confirmation of weld repairs to broken pipe hangers
Construction/Loadline › Hull › Hull Plating
Issued 29 June 2004 Resolved
8" crack in weld seam in way of peak tank, starboard side 3' above waterline, starting 3" fwd of collision bulkhead. Crop and repair using 18"x18" insert.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2004
Resolved 30 June 2004
Resolution: Cropped and renewed damaged area with 18"x18" plate insert and 3'' longitudinal stiffener.
Construction/Loadline › Hull › Weld
Issued 22 April 2003 Resolved
Reweld 03 fractures in stern corner stbd side, as identified by CG inspector.
Action required: 705 - Other - as specified
Due 22 May 2003
Resolved 22 April 2003
Resolution: Owner rewelded stern corner fractures, stbd side.
Construction/Loadline › Markings
Issued 18 June 2002 Resolved
EMERGENCY FUEL SHUTOFFS NOT STENCILED. LEGACY COMPONENT DESC: EMERGENCY FUEL SHUTOFF
Due 18 June 2002
Resolved 18 June 2002
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 18 June 2002 Resolved
NO DIAMOND DAY SHAPE AVAILABLE.
Due 18 June 2002
Resolved 18 June 2002
Documentation › Manuals/Policy Documentation
Issued 18 June 2002 Resolved
NAVIGATIONAL PUBLICATIONS OUT OF DATE. LEGACY COMPONENT DESC: NAVIGATION PUBLICATIONS
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 18 June 2002
Stability › Watertight Integrity
Issued 18 June 2002 Resolved
BILGE ALARMS NOT CONNECTED TO INDEPENDANT CIRCUITS. LEGACY COMPONENT DESC: BILGE ALARMS
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 18 June 2002
Construction/Loadline › Structures
Issued 6 November 2001 Resolved
Repair fractured weld/base metal at port side stern wrapper.
Condition: Unknown
Due 5 January 2002
Resolved 9 April 2002
Construction/Loadline › Penetrations
Issued 6 November 2001 Resolved
Double clamp 4 flexible hose couplings on shaft logs.
Condition: Unknown
Due 5 January 2002
Resolved 9 April 2002
Construction/Loadline
Issued 24 August 2000 Resolved
Repair hole IWO watertight transverse bulkhead between passageway and engineroom.
Condition: Unknown
Due 24 August 2000
Resolved 29 August 2000
Construction/Loadline
Issued 24 August 2000 Resolved
Repair three(3) fractured welds as follows: 1. foward peak tank, stbd side.2. Steering gear compartment IWO port wrap around. 3. Generator room IWO tonnage panel.
Condition: Unknown
Due 24 August 2000
Resolved 29 August 2000
Deck/Cargo
Issued 24 August 2000 Resolved
Replace shackle pin for anchor line in foward peak tank.
Condition: Unknown
Due 25 September 2000
Resolved 29 August 2000
Lifesaving
Issued 24 June 1999 Resolved
DEMONSTRATE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PROPER OPERATION OF THE JASONS CRADLE AS A RESCUE APPARTATUS IN ACCORDANCE WITH 46CFR180.210 NLT 24JULY99.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 18 March 1997 Resolved
MAKE REPAIRS TO BROKEN SEAM WELD IN WAY OF PORT STERN WRAPPER PLATE AT FOURTH SIDE LONG.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Engineering
Issued 18 March 1997 Resolved
PROVIDE SIGHT GLASS GUARDS FOR ALL EXPANSION TANKS.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Engineering
Issued 18 March 1997 Resolved
PROVIDE PROPOSAL TO REPAIR EXCESSIVE OIL LEAKS FORM STBD MAIN AND STBD GEN SET.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Fire Fighting
Issued 18 March 1997 Resolved
PROVIDE FIRE EXTINGUISHER FOR PORT SIDE ENGINE ROOM.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Engineering
Issued 18 March 1997 Resolved
MAKE PERMANENT REPAIRS TO STBD DAY TANK IN WAY OF SOFT PATCH.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Navigation
Issued 27 June 1996 Resolved
PROVIDE MAGNETIC DEVIATION TABLE.
Condition: Unknown
Due 27 June 1996
Resolved 27 June 1996
Construction/Loadline
Issued 7 July 1994 Resolved
CROP AND RENEW SIDE SHELL PORT SIDE GENERATOR ROOM IN WAY OF TEMPORARY REPAIRS MADE TO REMOVED DECK DRAIN.
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Construction/Loadline
Issued 7 July 1994 Resolved
CROP AND RENEW SIDE SHELL AND DOUBLER PLATE FOR BOTH PORT AND STRBD EXHAUSTPIPES.
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Electrical
Issued 15 July 1993 Resolved
REPLACE THE AMP METERS FOR THE #1 AND #2 GENERATORS.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Engineering
Issued 30 August 1991 Resolved
REMOVE ALL FUEL OIL TRANSFER PIPING AND ASSOCIATED EQUIPMENT TO ENSURE VESSEL IS NOT CAPABLE OF TRANSFERRING FUEL OIL TO OR FROM VESSELS._x001C_
Condition: Unknown
Due 30 August 1991
Resolved 30 August 1991
Accommodation/Occupational Safety
Issued 30 August 1991 Resolved
PROPOSED ALTERATIONS TO ENGINEROOM VENTILATION SYSTEM SHALL BE APPROVED BY THE COGNIZANT OFFICER IN CHARGE, MARINE INSPECTION. PROVIDE DRAWINGS, SKETCHES AND WRITTEN SPECIFICATIONS DEPICTING THE ALTERATIONS IN DETAIL FORAPPROVAL._x001C_
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Navigation
Issued 30 August 1991 Resolved
REPAIR #1 HYDRAUILIC STEERING PUMP._x001C_
Condition: Unknown
Due 30 August 1991
Resolved 30 August 1991
Accommodation/Occupational Safety
Issued 30 August 1991 Resolved
PROVE PROPER OPERATION OF STARBOARD ENGINEROOM POWER VENTILATOR AND REMOTE SHUTDOWN._x001C_
Condition: Unknown
Due 30 August 1991
Resolved 30 August 1991
Engineering
Issued 30 August 1991 Resolved
WHERE LIQUID LEVEL INDICATING GAGES ARE INSTALLED, THEY SHALL BE OF HEAT RESISTANT MATERIALS AND BE ADEQUATELY PROTECTED FROM MECHANICAL DAMAGE._x001C_
Condition: Unknown
Due 30 August 1991
Resolved 30 August 1991
Engineering
Issued 9 August 1991 Resolved
VESSEL PERMITTED TO PROCEED TO PANAMA CITY, FLORIDA TO COMPLETE REPAIRS TO STARBOARD CENTER MAIN ENGINE AND OTHER FIRE DAMAGE.
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Construction/Loadline
Issued 24 September 1989 Resolved
PRIOR TO RETURNING VSL TO SERVICE, MAKE PERMANENT REPAIRS TO VESSEL BOW WHERE HOLED. REPAIR TO BE COMPLETED TO THE MSO MORGAN CITY, LA ZONE, UNLESS OTHERWISE ARRANGED WITH THE INSPECTION DEPT.
Condition: Unknown
Due 24 September 1989
Resolved 24 September 1989
Deck/Cargo
Issued 16 August 1986 Resolved
PROVIDE AT LEAST TWO 450 POUND DANFORTH STANDARD ANCHORS ONBOARD THE VESSELWITH ANCHOR LINES WHICH HAVE AN APPROXIMATE BREAKING STRENGTH OF 29000 LBS.
Condition: Unknown
Due 16 August 1986
Resolved 16 August 1986
Unknown
Issued 13 August 1984 Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE M/V HELEN N, O.N. 660815. THE BELOW LISTED ITEM IS TO BE COMPLIED WITH BY 01OCT84.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Unknown
Issued 13 August 1984 Resolved
PROVIDE AN OIL TRANSFER PROCEDURE IN ACCORDANCE WITH 33 CFR 155.750.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984

Casualty record · 2

1 August 2011Routine · role: Involved in a Marine Casualty · activity 4105191
10 August 2022Routine · role: Involved in a Marine Casualty · activity 7530225
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

KERRIE D (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.