Records from 1982 to 2008. Most recent: inspection, 28 May 2008.
Inspection history · 44
28 May 2008
Hull Examination · Deficiency Check · Re-Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3220501
12 July 2007
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2992602
29 June 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2801477
27 June 2006
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2693026
11 July 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2443193
29 June 2004
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2073351
1 June 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2085481
16 December 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1964860
24 July 2002
Administrative Inspection · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1650979
9 July 2002
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1643060
12 June 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1472985
10 July 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399424
26 July 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423224
27 June 1998
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1463394
26 June 1998
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1473234
28 October 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 104152
25 November 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 132286
1 July 1996
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1353964
1 July 1996
Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1459325
5 July 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357229
4 May 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1180369
30 June 1994
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398092
8 July 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1395956
9 July 1992
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 946257
15 April 1992
Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267220
16 September 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 937500
21 August 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 941120
18 July 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 939267
31 July 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 910364
19 July 1990
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 926359
4 January 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 923044
18 August 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1198262
20 July 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 897918
20 July 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208707
11 October 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1194705
21 July 1988
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1340999
20 August 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002734
23 July 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030368
24 July 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997090
31 December 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307500
25 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983584
26 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974660
4 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281685
6 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971592
Fire Fighting › Means of Escape › Emergency Lighting
Issued 28 May 2008
Resolved
Place emergency light in the fwd engine room, crew quarters fwd, and fwd passenger compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2008
Documentation › Markings/Placards › Warning Signs
Issued 28 May 2008
Resolved
Label stove disconnect in engine room
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 20 June 2008
Engineering › Generator (propulsion-electric) › Winding
Issued 28 May 2008
Resolved
Clean excess oil under both generators
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 May 2008
Resolved
Place cover on light above range.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 20 June 2008
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 July 2007
Resolved
Galley receptacle needed a cover put on.
Due 12 August 2007
Resolved 24 July 2007
Resolution: Cover replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 July 2007
Resolved
Stern light was inoperable,
Due 12 July 2007
Resolved 12 July 2007
Resolution: Discrepancy was corrected during the course of inspection.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 12 July 2007
Resolved
E/R supply vent closures were stiff and difficult to use after being painted. Securing pins were difficult to install.
Due 12 August 2007
Resolved 24 July 2007
Resolution: Worked ventilation enclosures, and verified proper mounting in case of fire.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 12 July 2007
Resolved
Clothes dryer in E/R needs duct and lint catch installed.
Due 12 August 2007
Resolved 24 July 2007
Resolution: Dryer in E/R had lint catch installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 July 2007
Resolved
MDE's need to have a machinery guard installed on the front side of all 4 engines.
Due 12 August 2007
Resolved 6 August 2007
Resolution: Machinery guards installed on front of MDE''s.
Electrical › Electric Generation Source (service) › Generator
Issued 12 July 2007
Resolved
STBD MDG needs a minor repair to an oil/fuel line. Both MDG's need to be cleaned.
Due 12 August 2007
Resolved 24 July 2007
Resolution: Repaired and cleaned MDG''s.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 July 2007
Resolved
Lagging missing off 4 inch section of #2 MDE exhaust near water injection point.
Due 12 August 2007
Resolved 24 July 2007
Resolution: Lagging on #2 MDE renewed.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 12 July 2007
Resolved
Main fuel piping manifold needs installed piping to reduce the length of fuel hose to <30" in total length.
Due 12 August 2007
Resolved 6 August 2007
Resolution: Reduced flexible fuel hose on main fuel piping manifold to meet Shipping regulations.
Documentation
Issued 12 June 2001
Resolved
NO WRITTEN PROCEDURES
Condition: Unknown
Due 12 June 2001
Resolved 20 June 2001
Lifesaving
Issued 27 June 1998
Resolved
Route of clothes dryer vent inappropriate, allowed lint to collect on dryerelectrical system
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Electrical
Issued 27 June 1998
Resolved
Incandescent lights under navigation console not protected
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Engineering
Issued 27 June 1998
Resolved
Port air compressor could not provide pressure over 50 psi to port receiver
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Electrical
Issued 27 June 1998
Resolved
P/S generators output Hz frequency needed adjustment (62/63 Hz vice 60 Hz)
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Lifesaving
Issued 27 June 1998
Resolved
Newly installed refrigerator and washing machine not secured to cradle
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Engineering
Issued 27 June 1998
Resolved
Fueling station not stenciled
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Lifesaving
Issued 27 June 1998
Resolved
Missing flame screen to paint locker vent
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Electrical
Issued 27 June 1998
Resolved
Permanent use of temp electrical outlet "multiplier" (3-1)
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Engineering
Issued 27 June 1998
Resolved
Machinery guards around moving parts to #1 and #3 MDEs insufficient
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Fire Fighting
Issued 27 June 1998
Resolved
Protective glass to fire pump pressure guage broken
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Lifesaving
Issued 27 June 1998
Resolved
Excessive flammables stored outside paint locker
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Lifesaving
Issued 27 June 1998
Resolved
Excessive debris under navigation console
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Navigation
Issued 27 June 1998
Resolved
Missing plug to air supply system drain (Navigation controls)
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Lifesaving
Issued 27 June 1998
Resolved
Rescue platform missing side support cable (1 of 2)
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Electrical
Issued 27 June 1998
Resolved
Emergency batteries missing movement minimizing blocks inside storage box
Condition: Unknown
Due 27 June 1998
Resolved 24 July 1998
Construction/Loadline
Issued 26 June 1998
Resolved
Excessive sea growth in channels to sea valve housings
Condition: Unknown
Due 26 June 1998
Resolved 24 July 1998
Construction/Loadline
Issued 26 June 1998
Resolved
(Steering compt) Unfinished fit-up welds in P/S fwd w/t blkhds (orig construction)
Condition: Unknown
Due 26 June 1998
Resolved 24 July 1998
Navigation
Issued 26 June 1998
Resolved
2 small fractures in port rudder mount/base
Condition: Unknown
Due 26 June 1998
Resolved 24 July 1998
Construction/Loadline
Issued 26 June 1998
Resolved
Excessive trash in engineroom bilge (plastic containers, cable ties)
Condition: Unknown
Due 26 June 1998
Resolved 24 July 1998
Construction/Loadline
Issued 26 June 1998
Resolved
Small thru-hull puncture in way of port side stem_x001C_ Excessive gouge in hull plate in way of fwd fuel tank, port side, 4' abv keel
Condition: Unknown
Due 26 June 1998
Resolved 24 July 1998
Documentation
Issued 5 July 1995
Resolved
PROVIDE COPY OF VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 5 July 1995
Resolved 5 July 1995
Construction/Loadline
Issued 18 July 1991
Resolved
CROP OUT AND RENEW 18" X 24" SECTION OF CORNER WRAP FROM DECK ON STBD SIDE AND 18" AREA OF ASSOCIATED DECK PLATE.
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Unknown
Issued 20 July 1989
Resolved
REPAIR/PEPLACE PIPING NEXT TO FLEX JOINT WHERE EXHAUST SYSTEM IS LEAKING ONINBOARD PORT PROPULSION ENGINE.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
REPLACE BATTERY TRAY (LOCATED AFT OF ENG. PORT SIDE OF ENGINE ROOM) FOR GENERATOR STARTING BATTERIES.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Navigation
Issued 23 July 1987
Resolved
FREE UP TOREPEAK BILGE SUCTION VALVE.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Lifesaving
Issued 23 July 1987
Resolved
MARK THE EMERGENCY EXITS FROM THE E.R. AND THE LOWEWR ACCOMENDATION SPACES WITH EMERGENCY EXIT KEEP CLEAR.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Accommodation/Occupational Safety
Issued 23 July 1987
Resolved
VENT THE CLOTHES DRYER OUTSIDE THE E.R. OR PROVIDE METHOD TO COLLECT LINT.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Electrical
Issued 23 July 1987
Resolved
PROVIDE PROTECTIVE COVER TO BATTERY FOR (P) GENERATOR.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Deck/Cargo
Issued 23 July 1987
Resolved
STENCIL F.O. TRANSFER PUMP REMOTE SHUT DOWN.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Lifesaving
Issued 23 July 1987
Resolved
TIE STACKED LIFERAFTS TOGETHER (WITH LOOP AROUND BODY OF RAFT) OR PROVIDE FLOAT FREE LINK FOR EACH RAFT. PROVIDE A NEW LINK FOR THE (P) SET OF RAFTS.SECURE PADDLES TO EACH INDIVIDUAL RAFT.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987