Records from 2016 to 2024. Most recent: inspection, 10 September 2024.
Inspection history · 18
10 September 2024
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8000191
5 May 2024
COC-TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7906608
7 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7824846
2 September 2023
COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7781135
2 September 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7783131
28 August 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7778917
25 April 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7675601
19 April 2023
COC-TVE Annual · PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7669544
18 March 2022
PSC B · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7408978
8 August 2017
COC-TVE Annual · Ballast Water Examination · Deficiency Check · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6229343
21 March 2017
NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6109184
21 March 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6123720
21 March 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6153255
19 March 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6107370
7 June 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5900251
7 June 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5900305
20 April 2016
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5845092
2 March 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5825138
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 5 May 2024
Resolved
The venting system shall be provided with devices to prevent the passage of flame in to the cargo tanks.
PSCO observed all P/V vales on cargo deck to have gaps and openings as well as paint covering flame arrestors.
74 SOLAS II-2/4.5.3.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 September 2024
Resolution: Received class report attesting to proper operation of all P/V valves.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 19 April 2023
Resolved
The owner or operator of a foreign flagged tank vessel may submit certification that the vapor control system (VCS) meets the requirements of this part. The ship's high pressure in cargo tank alarms were set at 15.4 kpa and were above the 11.7 kpa maximum as required by the vapor emissions control manual (VECS).
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 19 April 2023
Resolved 19 April 2023
Resolution: Ships crew adjusted tanks high pressure alarms to 11.7 kpa
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 19 April 2023
Resolved
the venting arrangements shall be so designed and operated to ensure that neither pressure/vacuum in cargo tanks shall exceed design parameters. Found the # 3p, 5p, and 6s pressure vacuum valves to be freely passing vapors through the vacuum side of the valve.
74solas(04)II-2/11.6.1
Action taken: 60 c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 April 2023
Resolved 19 April 2023
Resolution: Ships crew cleaned and refit valves
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 19 April 2023
Resolved
The ship shall be designed, constructed, and maintained in compliance with the structural requirements of class society. Found the starboard hawsepipe's safety rail fractured and broken, creating a fall hazard.
74solas(20)II-1/3-1
Action taken: 17 ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2023
Resolved 22 April 2023
Resolution: accepted class report
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 19 April 2023
Resolved
Davit launched liferafts shall be stowed within reach of lifting hooks. port side life raft is of the davit launched type, but no davit is on board. PSCO raising concern that the raft may not be suitable for launching of the raft without the davit.
74solas(20)III/13.5
Action taken: 50 ac
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2023
Resolved 25 April 2023
Resolution: Based on objective evidence RO attest that the def is now ractified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 19 April 2023
Resolved
Ship shall be designed and maintained in compliance with the structural requirements of class society. Found the #4p, 6P, 4s, 6s, 8s, 3s ballast vent covers wasted with poor gasketing, creating a down flooding hazard.
74solas(20)II-1/3-1
Action taken: 50 ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2023
Resolved 25 April 2023
Resolution: Based on objective evidence RO attest that the def is now ractified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 March 2022
Resolved
Door frames in 'A' class divisions shall provde resistace to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. Two 'A' class door frames does not provide resistance to smoke.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 March 2022
Resolved 18 March 2022
Resolution: sill replaced, corrected on the spot
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 March 2022
Resolved
Hold back hooks not subject to central control station release are prohibited. Hold back hooks were installed on three fire doors for galley.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 March 2022
Resolved 18 March 2022
Resolution: hooks taken off
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 18 March 2022
Resolved
Befor the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immeadiate use. Painter lines on both life rafts were not conected to the weak link.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 March 2022
Resolved 18 March 2022
Resolution: properly installed
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 August 2017
Resolved
Fire doors in main vertical zone bulkheads, galley boundries, and stairway enclosures shall satisfy the following requirements: the doors shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. 03 "A" class doors in the galley were not capable of self-closing. 74SOLAS(2014) II-2/9.4.1.1.5.1
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 14 August 2017
Resolution: Ship provided Class Report attesting to the repairs conducted to the fire doors in the Galley.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 August 2017
Resolved
Fire doors in main vertical zone bulkheads, galley boundries, and staiway enclosures shall satisfy the following requirements: hold-back hooks not subject to central control station release are prohibited. 03 "A" class doors in galley had prohibited hold-back hooks. 74SOLAS(2014)
Action required: 15 - Rectify deficiencies by next port
Resolved 14 August 2017
Resolution: Received Class Report attesting to the removal of all three hold-back hooks for the doors in the Galley.