MAURY USCG vessel records
← All vessels

ISABELLA ROSE

ISABELLA ROSE is a 1982 offshore supply vessel. The Coast Guard has recorded 17 inspections since 2016, most recently in April 2026, along with 43 deficiencies, 1 operational control and 2 casualty investigations between 2001 and 2011.

Records from 2001 to 2026. Most recent: inspection, 14 April 2026.

Built
1982
Last inspected
14 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH4138
Flag
UNITED STATES
Maury page id
psix-53865

Documentation record

Registered dimensions (L × B × D)118.7 ft × 32.0 ft × 11.5 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)118.7 ft × 32.0 ft × 11.5 ft
ITC tonnagegross 323 / net 96
BuilderMARINE FABRICATORS INC · GREEN COVE SPRINGS, FL, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOCKPORT, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 December 2025 · expires 31 January 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it323 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
96 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

17 inspections, each with its date, unit and type; 43 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; 1 other recorded name, with years; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

14 April 2026 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8334473
18 February 2026 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8296312
12 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8135698
8 May 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7904148
14 February 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7863352
17 May 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7690566
7 March 2022 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7406998
2 June 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7212986
27 January 2021 Deficiency Check · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7131510
22 April 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6942222
7 February 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6621903
15 January 2019 Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6610656
7 June 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6437234
2 February 2018 Type not recorded
No type recorded · USCGC SAILFISH (WPB 87356) · USCG Northeast District (CGD-NE) · Activity 6352018
9 March 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6102195
17 May 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5879891
8 January 2016 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5793975

Deficiency record · 43

11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 14 April 2026 Resolved
Each vessel must carry an auxiliary line that is at least 1,500 feet which has a breaking strength of at least 9,000 pounds force for the line-throwing appliance. Vessel's auxiliary line was not the required length of at least 1,500 feet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 17 April 2026
Resolution: 1500 ft of line provided.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 14 April 2026 Resolved
Vessel must have video and audio surveillance placed in passageways on to which doors from staterooms open and provide clear and conspicuous signs on board, notifying the crew of the presence of video and audio surveillance. Vessel was not equipped with audio and video surveillance and are waiting for the contracted company to install the equipment. 46 USC 4901
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2026
Resolved 4 May 2026
Resolution: Cameras installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 April 2026 Resolved
One length of fire hose shall be provided for each fire hydrant required. Vessel's fire hose ruptured while testing the fire pump from the aft deck fire station.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 April 2026
Resolved 14 April 2026
Resolution: New hose provided and stenceled.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 May 2025 Resolved
Each vessel must be equipped with one self-priming power-driven fire pump. The pump on board maintained necessary pressure, but was leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 14 May 2025
Resolution: Seal plate was replaced and new impeller and seal kit installed. Pump body and shaft cleaned, reassembled and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 May 2024 Resolved
Paint lockers and similar compartments must be constructed of steel or be wholly lined with steel. The paint locker located on the second weather deck was made of aluminum and not lined with steel. 46 CFR 127.220
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2024
Resolved 21 May 2024
Resolution: New steel paint locker ordered to replace aluminum one.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 May 2024 Resolved
Each hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss. The emergency escape trunk leading from the engine room to the main deck did not have a securing device on the hatch cover. 46 CFR 127.230 46 CFR 174.220(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2024
Resolved 9 May 2024
Resolution: Captaive chain replaced.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 8 May 2024 Resolved
Each general alarm bell must be identified by red letters at least 13 millimeters high that state the following: "GENERAL ALARM - WHEN BELL RINGS GO TO YOUR STATION." The General Alarm bells throughout the accommodations space did not contain required lettering. 46 CFR 131.810
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2024
Resolved 9 May 2024
Resolution: General alarm sign replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 May 2024 Resolved
Each lifefloat must be approved under approval series 160.027 and be equipped with the following:One self-igniting light attached to the lifefloat by a 12-thread manila or equivalent lanyard, at least 18 feet long. The line attached to the light was only approximately 8 feet long. 46 CFR 133.90(a)(4)(iv)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2024
Resolved 9 May 2024
Resolution: New approved 18 foot line added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 7 March 2022 Resolved
Exhaust pipe installations must conform to the requirements of NFPA 302. Exhaust trunk running though the aft operating station cabin had an exhaust leak. Repair leak.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2022
Resolved 17 March 2022
Resolution: Piping was welded to correct the leaak and exhaust lagging was added to replace saturated existing lagging.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 March 2022 Resolved
Buoyant apparatus shall be kept in good condition. The buoyant apparatus was cracked and missing potions of the outer coating. Repair or replace.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2022
Resolved 10 March 2022
Resolution: Buoyant apparatus was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 March 2022 Resolved
The float free link must be certified to meet 160.073 of this sub chapter. The weak link was missing the certification tag. Replace the weak link.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 10 March 2022
Resolution: Float free link was replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 7 March 2022 Resolved
Must have lights for the continuous illumination of the stowage position of life rafts.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 10 March 2022
Resolution: Lighting fixtured was re-worked and corrected to provide proper lighting.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 March 2022 Resolved
Two projectiles shall be of the buoyant type. Line throwing gun did not have to bouyant type projectiles.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 10 March 2022
Resolution: Vessel obtained two floating projectiles.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 June 2021 Resolved
Vessel required to have updated charts. Chart correction log last updated Dec 2020.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2021
Resolution: New charts provided and master will keep updated.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 2 June 2021 Resolved
Ventilation must be able to be secured from outside the space. E-stop for engine room ventilation not operable.
Action required: 10 - Deficiency Rectified
Resolved 2 June 2021
Resolution: Switch repaired prior to completion of inspection.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 June 2021 Resolved
Vessel required required EPIRB. Tamper seal on EIRB missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2021
Resolution: New EPIRB purchased and registered.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 February 2019 Resolved
LIFE FLOAT ARE REQURIED TO BE SERVICEABLE. VSL PORT LIFE FLOAT WAS DAMAGED. VSL MUST PROVIDE SUFFICIENT SERVICEABLE LIFE FLOATS.
Action required: 10 - Deficiency Rectified
Resolved 7 February 2019
Resolution: VSL PROVIDED NEW LIFE FLOAT TO REPLACE NON-SERVICEABLE LIFE FLOAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2019 Resolved
MACHINERY GUARDS ARE REQUIRED TO BE IN PLACE. VSL STBD ENGINE IS MISSING SHAFT GUARD. VSL MUST PROVIDE SHAFT GUARD FOR STBD ENGINE.
Action required: 10 - Deficiency Rectified
Resolved 7 February 2019
Resolution: VSL PROVIDED SHAFT GUARD FOR STBD MDE SHAFT
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 7 June 2018 Resolved
Diesel piping on starboard engine is leaking excessive fuel. Replace pipe to stop leaking.
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: Pipe replaced eliminating leak
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (air intake)
Issued 7 June 2018 Resolved
Air filters on all engines saturated in oil. All need replaced.
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: Air filters properly replaced.
Engineering › Steering Gear System › Helix Shaft
Issued 7 June 2018 Resolved
Packing glands on port and starboard shafts leaking profusely. Repair appropriately to stop leaking.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: Packing glands repaired to eliminate leaking.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 7 June 2018 Resolved
Emergency fuel shutdown not working.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: Shutdown was retested and found satisfactory.
Engineering › Steering Gear System › Rudder Stock
Issued 7 June 2018 Resolved
Rudder posts leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: Rudder posts repaired eliminated leaking
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 7 June 2018 Resolved
General alarm not operable on emergency power.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: General alarm tested and is operational.
Construction/Loadline › Penetrations › Gasket
Issued 7 June 2018 Resolved
Gasket on engine room door worn. Replace gasket.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: Gasket replaced properly.
Engineering › Steering Gear System › Cable
Issued 7 June 2018 Resolved
Replace cable in engine room from steering box to remote/local box.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 June 2018
Resolved 12 June 2018
Resolution: Cable replaced properly
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 7 June 2018 Resolved
Port engine hose, near bottom, kinked and is too long.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 June 2018
Resolved 12 June 2018
Resolution: Hose fixed to apppropriate size.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 March 2017 Resolved
COI expired 14FEB17 and had been operating
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2018
Resolution: Vessel had annual exam.
Construction/Loadline › Structures › Superstructure
Issued 10 March 2017 Resolved
Missing window in aft operating station
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Installed new window.
Engineering › Steering Gear System › Rudder
Issued 10 March 2017 Resolved
Rudder compartment leak near port & starboard packing at rudders
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Both greease fittings were rusted out and water was leaking into rudder room. Tap and Die of new threads were complete with new fitting. Rudders had no leakage in rudder room.
Engineering › Steering Gear System › Hydraulic Hose
Issued 10 March 2017 Resolved
Hydraulic hose leak starboard side rudder.
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Tightened hose fitting and tested SAT.
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 March 2017 Resolved
Ventilation remote stopping station stuck in one position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Replaced switch and operated. Test Sat
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2017 Resolved
Electrical cabling under operation console requires maintenance and contains wire nuts. Remove wire out of port generator junction box and seal. Deteriorated cable in starboard generator battery box w/wire nuts. Electrical splicing on cable near plug at bottom of latterwell to engine room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Wire nuts have been removed and all wires have proper terminal connections. Cleaned up wiring and removed existing wiring not in use.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 10 March 2017 Resolved
Fire extinguisher located by galley missing servicing tag
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2017
Resolution: Third party came and retested extinguisher and placed inspection tag on extinguisher.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2017 Resolved
Cable on bow thruster to solenoid require crimped connectors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Wire nuts have been removed and all wires have proper terminal connections.
Engineering › Pressure Vessel › Shell Plate
Issued 10 March 2017 Resolved
Corrosion and grease inside forward pressure vessel; needs to be hydrostatically tested at 1.5 times the MAWP.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Third party conducted UT shots and hydrotested pressure vessel to 1 1/2 times MAWP. Viewed tech reports, all Sat
Engineering › Diesel Engine (propulsion-reduction gear) › Connecting Rod
Issued 10 March 2017 Resolved
Repair and connect fuel rack solenoid on starboard engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2017
Resolution: Diesel Tech rep came out to fix solenoid. Tech said it was a after market engine was not manufactured that way. Vessel not required to have soleniod for push button shutdowns from pilot house.
Construction/Loadline › Hull › Bracket
Issued 10 March 2017 Resolved
Maintenance of lifebuoy bracket - rusted at the bolts on the rail both port and starboard side of wheelhouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Welded new bracket. Sat
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 10 March 2017 Resolved
Rescue platform needs to be shortened so as to not be fully submerged when vessel is loaded.
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Shorted rescue platform. Tested Sat.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 March 2017 Resolved
For the Standby Vessel Endorsement: vessel is missing 01 life preserver, needs 04 unexpired rockets for launching appliances; leaking fire monitors require maintenance.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2017
Resolution: Purchased lifejacket. Counted all required life jackets and number matched requirements.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 9 March 2017 Resolved
Shaft packing leaking significantly on starboard and port shafts
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2017
Resolution: Tightened shaft packing, no leaks.
Lifesaving › Lifefloat › Paddle
Issued 17 May 2016 Resolved
required vsl to replace all broken or worn paddles
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 18 May 2016
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 May 2016 Resolved
required vsl to go through and replace worn and painted retroreflextive material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 18 May 2016

Casualty record · 2

2 November 2001Major Marine Casualty · role: Involved in a Marine Casualty · activity 166058
21 March 2011Routine · role: Involved in a Marine Casualty · activity 3975601
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

EMILY BORDELON (2001–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.