Records from 1984 to 2026. Most recent: inspection, 14 April 2026.
Inspection history · 49
14 April 2026
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8334473
18 February 2026
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8296312
12 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8135698
8 May 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7904148
14 February 2024
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7863352
17 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7690566
7 March 2022
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7406998
2 June 2021
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7212986
27 January 2021
Deficiency Check · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7131510
22 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6942222
7 February 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6621903
15 January 2019
Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6610656
7 June 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6437234
2 February 2018
Type not recorded
No type recorded · USCGC SAILFISH (WPB 87356) · USCG Northeast District (CGD-NE) · Activity 6352018
9 March 2017
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6102195
17 May 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5879891
8 January 2016
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5793975
29 October 2014
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 5018115
7 March 2014
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4811224
14 February 2012
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4243504
18 January 2011
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3926763
7 December 2010
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3906336
9 March 2010
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3691984
18 February 2009
Examination of Repairs · Periodic Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3423692
7 November 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3426710
25 April 2008
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3191970
5 April 2007
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2902309
7 March 2006
Internal Structural Exam · Hull Examination · Re-Inspection · Cargo Tank Internal · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2598417
28 April 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2339068
7 April 2005
In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2328798
25 February 2004
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2012742
24 February 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1748587
1 May 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1611238
28 March 2002
Examination of Repairs
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1475599
4 November 2001
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1076305
2 November 2001
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 166058
23 March 2001
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397605
8 May 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453754
20 October 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 215360
25 May 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799695
18 March 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384077
27 January 1997
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 764441
2 December 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 190408
28 January 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 95223
31 August 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 667926
20 August 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 124317
17 July 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293425
5 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287625
25 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974054
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 14 April 2026
Resolved
Each vessel must carry an auxiliary line that is at least 1,500 feet which has a breaking strength of at least 9,000 pounds force for the line-throwing appliance.
Vessel's auxiliary line was not the required length of at least 1,500 feet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 17 April 2026
Resolution: 1500 ft of line provided.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 14 April 2026
Resolved
Vessel must have video and audio surveillance placed in passageways on to which doors from staterooms open and provide clear and conspicuous signs on board, notifying the crew of the presence of video and audio surveillance.
Vessel was not equipped with audio and video surveillance and are waiting for the contracted company to install the equipment.
46 USC 4901
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2026
Resolved 4 May 2026
Resolution: Cameras installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 April 2026
Resolved
One length of fire hose shall be provided for each fire hydrant required.
Vessel's fire hose ruptured while testing the fire pump from the aft deck fire station.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 April 2026
Resolved 14 April 2026
Resolution: New hose provided and stenceled.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 May 2025
Resolved
Each vessel must be equipped with one self-priming power-driven fire pump. The pump on board maintained necessary pressure, but was leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 14 May 2025
Resolution: Seal plate was replaced and new impeller and seal kit installed. Pump body and shaft cleaned, reassembled and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 May 2024
Resolved
Paint lockers and similar compartments must be constructed of steel or be wholly lined with steel. The paint locker located on the second weather deck was made of aluminum and not lined with steel.
46 CFR 127.220
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2024
Resolved 21 May 2024
Resolution: New steel paint locker ordered to replace aluminum one.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 May 2024
Resolved
Each hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss. The emergency escape trunk leading from the engine room to the main deck did not have a securing device on the hatch cover.
46 CFR 127.230
46 CFR 174.220(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2024
Resolved 9 May 2024
Resolution: Captaive chain replaced.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 8 May 2024
Resolved
Each general alarm bell must be identified by red letters at least 13 millimeters high that state the following: "GENERAL ALARM - WHEN BELL RINGS GO TO YOUR STATION." The General Alarm bells throughout the accommodations space did not contain required lettering.
46 CFR 131.810
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2024
Resolved 9 May 2024
Resolution: General alarm sign replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 May 2024
Resolved
Each lifefloat must be approved under approval series 160.027 and be equipped with the following:One self-igniting light attached to the lifefloat by a 12-thread manila or equivalent lanyard, at least 18 feet long. The line attached to the light was only approximately 8 feet long.
46 CFR 133.90(a)(4)(iv)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2024
Resolved 9 May 2024
Resolution: New approved 18 foot line added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 7 March 2022
Resolved
Exhaust pipe installations must conform to the requirements of NFPA 302.
Exhaust trunk running though the aft operating station cabin had an exhaust leak. Repair leak.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2022
Resolved 17 March 2022
Resolution: Piping was welded to correct the leaak and exhaust lagging was added to replace saturated existing lagging.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 March 2022
Resolved
Buoyant apparatus shall be kept in good condition. The buoyant apparatus was cracked and missing potions of the outer coating. Repair or replace.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2022
Resolved 10 March 2022
Resolution: Buoyant apparatus was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 March 2022
Resolved
The float free link must be certified to meet 160.073 of this sub chapter.
The weak link was missing the certification tag. Replace the weak link.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 10 March 2022
Resolution: Float free link was replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 7 March 2022
Resolved
Must have lights for the continuous illumination of the stowage position of life rafts.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 10 March 2022
Resolution: Lighting fixtured was re-worked and corrected to provide proper lighting.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 March 2022
Resolved
Two projectiles shall be of the buoyant type. Line throwing gun did not have to bouyant type projectiles.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2022
Resolved 10 March 2022
Resolution: Vessel obtained two floating projectiles.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 June 2021
Resolved
Vessel required to have updated charts. Chart correction log last updated Dec 2020.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2021
Resolution: New charts provided and master will keep updated.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 2 June 2021
Resolved
Ventilation must be able to be secured from outside the space. E-stop for engine room ventilation not operable.
Action required: 10 - Deficiency Rectified
Resolved 2 June 2021
Resolution: Switch repaired prior to completion of inspection.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 June 2021
Resolved
Vessel required required EPIRB. Tamper seal on EIRB missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2021
Resolution: New EPIRB purchased and registered.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 February 2019
Resolved
LIFE FLOAT ARE REQURIED TO BE SERVICEABLE. VSL PORT LIFE FLOAT WAS DAMAGED. VSL MUST PROVIDE SUFFICIENT SERVICEABLE LIFE FLOATS.
Action required: 10 - Deficiency Rectified
Resolved 7 February 2019
Resolution: VSL PROVIDED NEW LIFE FLOAT TO REPLACE NON-SERVICEABLE LIFE FLOAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2019
Resolved
MACHINERY GUARDS ARE REQUIRED TO BE IN PLACE. VSL STBD ENGINE IS MISSING SHAFT GUARD. VSL MUST PROVIDE SHAFT GUARD FOR STBD ENGINE.
Action required: 10 - Deficiency Rectified
Resolved 7 February 2019
Resolution: VSL PROVIDED SHAFT GUARD FOR STBD MDE SHAFT
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 7 June 2018
Resolved
Diesel piping on starboard engine is leaking excessive fuel. Replace pipe to stop leaking.
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: Pipe replaced eliminating leak
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (air intake)
Issued 7 June 2018
Resolved
Air filters on all engines saturated in oil. All need replaced.
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: Air filters properly replaced.
Engineering › Steering Gear System › Helix Shaft
Issued 7 June 2018
Resolved
Packing glands on port and starboard shafts leaking profusely. Repair appropriately to stop leaking.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: Packing glands repaired to eliminate leaking.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 7 June 2018
Resolved
Emergency fuel shutdown not working.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: Shutdown was retested and found satisfactory.
Engineering › Steering Gear System › Rudder Stock
Issued 7 June 2018
Resolved
Rudder posts leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: Rudder posts repaired eliminated leaking
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 7 June 2018
Resolved
General alarm not operable on emergency power.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: General alarm tested and is operational.
Construction/Loadline › Penetrations › Gasket
Issued 7 June 2018
Resolved
Gasket on engine room door worn. Replace gasket.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 12 June 2018
Resolution: Gasket replaced properly.
Engineering › Steering Gear System › Cable
Issued 7 June 2018
Resolved
Replace cable in engine room from steering box to remote/local box.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 June 2018
Resolved 12 June 2018
Resolution: Cable replaced properly
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 7 June 2018
Resolved
Port engine hose, near bottom, kinked and is too long.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 June 2018
Resolved 12 June 2018
Resolution: Hose fixed to apppropriate size.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 March 2017
Resolved
COI expired 14FEB17 and had been operating
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2018
Resolution: Vessel had annual exam.
Construction/Loadline › Structures › Superstructure
Issued 10 March 2017
Resolved
Missing window in aft operating station
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Installed new window.
Engineering › Steering Gear System › Rudder
Issued 10 March 2017
Resolved
Rudder compartment leak near port & starboard packing at rudders
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Both greease fittings were rusted out and water was leaking into rudder room. Tap and Die of new threads were complete with new fitting. Rudders had no leakage in rudder room.
Engineering › Steering Gear System › Hydraulic Hose
Issued 10 March 2017
Resolved
Hydraulic hose leak starboard side rudder.
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Tightened hose fitting and tested SAT.
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 March 2017
Resolved
Ventilation remote stopping station stuck in one position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Replaced switch and operated. Test Sat
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2017
Resolved
Electrical cabling under operation console requires maintenance and contains wire nuts. Remove wire out of port generator junction box and seal. Deteriorated cable in starboard generator battery box w/wire nuts. Electrical splicing on cable near plug at bottom of latterwell to engine room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Wire nuts have been removed and all wires have proper terminal connections. Cleaned up wiring and removed existing wiring not in use.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 10 March 2017
Resolved
Fire extinguisher located by galley missing servicing tag
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2017
Resolution: Third party came and retested extinguisher and placed inspection tag on extinguisher.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2017
Resolved
Cable on bow thruster to solenoid require crimped connectors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Wire nuts have been removed and all wires have proper terminal connections.
Engineering › Pressure Vessel › Shell Plate
Issued 10 March 2017
Resolved
Corrosion and grease inside forward pressure vessel; needs to be hydrostatically tested at 1.5 times the MAWP.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Third party conducted UT shots and hydrotested pressure vessel to 1 1/2 times MAWP. Viewed tech reports, all Sat
Engineering › Diesel Engine (propulsion-reduction gear) › Connecting Rod
Issued 10 March 2017
Resolved
Repair and connect fuel rack solenoid on starboard engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2017
Resolution: Diesel Tech rep came out to fix solenoid. Tech said it was a after market engine was not manufactured that way. Vessel not required to have soleniod for push button shutdowns from pilot house.
Construction/Loadline › Hull › Bracket
Issued 10 March 2017
Resolved
Maintenance of lifebuoy bracket - rusted at the bolts on the rail both port and starboard side of wheelhouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Welded new bracket. Sat
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 10 March 2017
Resolved
Rescue platform needs to be shortened so as to not be fully submerged when vessel is loaded.
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 17 March 2017
Resolution: Shorted rescue platform. Tested Sat.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 March 2017
Resolved
For the Standby Vessel Endorsement: vessel is missing 01 life preserver, needs 04 unexpired rockets for launching appliances; leaking fire monitors require maintenance.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2017
Resolution: Purchased lifejacket. Counted all required life jackets and number matched requirements.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 9 March 2017
Resolved
Shaft packing leaking significantly on starboard and port shafts
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2017
Resolution: Tightened shaft packing, no leaks.
Lifesaving › Lifefloat › Paddle
Issued 17 May 2016
Resolved
required vsl to replace all broken or worn paddles
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 18 May 2016
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 May 2016
Resolved
required vsl to go through and replace worn and painted retroreflextive material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 18 May 2016
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 24 January 2011
Resolved
Demonstrate proper operation of both generators overspeed
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2011
Resolution: Both generators overspeed operating properly.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 24 January 2011
Resolved
Demonstrate proper emergency steering test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2011
Resolution: Proper emergency steering test demonstrated by crew.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 February 2009
Resolved
Provide adequate "E" lighting for main board and from rudder compartment.
Due 2 April 2009
Resolved 3 March 2009
Resolution: New light installed for rudder compartment and main board light repositioned to meet requirement.
Fire Fighting › Fire Hydrants › Condition
Issued 18 February 2009
Resolved
Repair leaking fire main rise valve, aft quarter, port main deck.
Due 2 April 2009
Resolved 2 March 2009
Resolution: Valve repaired.
Fire Fighting › Nozzles › Condition
Issued 18 February 2009
Resolved
Replace two [02] faulty / worn nozzles.
Due 2 April 2009
Resolved 3 March 2009
Resolution: Two new nozzles put into service.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 18 February 2009
Resolved
Demonstrate proper operation of the R.A.I.
Due 2 April 2009
Resolved 3 March 2009
Resolution: R.A.I. repaired and operating properly.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 25 April 2008
Resolved
Install an emergency light in the forward exit of engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2008
Resolution: Emergency light installed.
Engineering › Pressure Vessel › Relief Valve
Issued 25 April 2008
Resolved
Renew all pressure relief valves on all pressure vessels.
Due 25 May 2008
Resolved 2 March 2009
Resolution: Pop-offs were all replaced.
Navigation › Piloting/Steering › Marine Charts
Issued 25 April 2008
Resolved
Provide updated charts for area of operation.
Due 25 May 2008
Resolved 2 March 2009
Resolution: Charts for area of operations were available and corrected.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 April 2005
Resolved
Master to ensure compliance with stability ltr dated 12MAY82, cargo VCG not to exceed 3.0', prior to departure from dock.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2005
Resolved 7 April 2005
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 February 2003
Resolved
PROVIDE FIRE SAFETY PLAN FOR APPROVAL TO THE OCMI OF MORGAN CITY, LA.
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 27 February 2003
Lifesaving › Hand Flares › Storage
Issued 24 February 2003
Resolved
PAINT AND LABEL FLARE BOX WITH BRIGHT COLOR.
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 27 February 2003
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 May 2002
Resolved
PROPERLY REPAIR 110V BREAKER PANEL AT ENG ROOM ENT
Condition: Improper Installation
Due 1 May 2002
Resolved 1 May 2002
Construction/Loadline › Structures › Ventilators
Issued 1 May 2002
Resolved
PROVIDE AND MAKE READY FOR IMMEDIATE USE, VENT COVERS FOR ALL ENGINE ROOM AND ACCOMODATION VENT INTAKES.
Condition: Improper/Lack of Maintenance
Due 1 May 2002
Resolved 1 May 2002
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 May 2002
Resolved
ADD 01 ADDITIONAL EMERGENCY EGRESS LIGHT AT THE ENGINE ROOM ESCAPE AND AT THE FWD ENGINE ROOM LADDER
Condition: Improper Installation
Due 1 May 2002
Resolved 1 May 2002
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 May 2002
Resolved
PROVIDE UPDATED NAVIGATION PUBLICATIONS.
Due 1 May 2002
Resolved 1 May 2002
Pollution Prevention/Response › Prevention Equipment
Issued 30 April 2002
Resolved
POST DISCHARGE PLACARDS LEGACY COMPONENT DESC: PLACARDS
Due 1 May 2002
Resolved 1 May 2002
Engineering
Issued 8 May 2000
Resolved
PROVIDE F/O TRANSFER PROCEDURES AS PER 33CFR 155.750.
Condition: Unknown
Due 8 May 2000
Resolved 8 May 2000
Fire Fighting
Issued 8 May 2000
Resolved
PROVIDE FOR APPROVAL FIRE CONTROL PLAN AS PER 46CFR 91-55-5 (d).
Condition: Unknown
Due 8 May 2000
Resolved 8 May 2000
Engineering
Issued 8 May 2000
Resolved
COMPLETE HYDRO OF FUEL TRANSFER HOSES TO 1.5 TIMES M.A.W.P.
Condition: Unknown
Due 8 May 2000
Resolved 8 May 2000
Navigation
Issued 18 March 1999
Resolved
PROVIDE AN UPDATED MAGNETIC COMPASS DEVIATION TABLE.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Documentation
Issued 18 March 1999
Resolved
PROVIDE THE STABILITY LETTER DATED 25MAY84 BY MSO JACKSONVILLE ONBOARD.
Condition: Unknown
Due 22 March 1999
Resolved 22 March 1999
Unknown
Issued 5 July 1985
Resolved
EFFECT PERMANENT REPAIRS TO DAMAGED PORT ENGINE ROOM MAIN DECK ESCAPE HATCH
Condition: Unknown
Due 5 July 1985
Resolved 5 July 1985
Unknown
Issued 5 July 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL SALLEE DN648049
Condition: Unknown
Due 5 July 1985
Resolved 5 July 1985
Unknown
Issued 5 July 1985
Resolved
REPLACE IN KIND STEEL CABLE FOR FUEL OIL REMOTE SHUT DOWN VALVE.
Condition: Unknown
Due 5 July 1985
Resolved 5 July 1985
Unknown
Issued 5 July 1985
Resolved
MAKE REPAIRS TO ANCHOR WINCH AND DEMONSTRATE PROPER OPERATION OF ANCHOR WINCH. THE ABOVE REPAIRS ARE TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT USCG MARINE INSPECTOR PRIOR TO 05AUG85.
Condition: Unknown
Due 5 July 1985
Resolved 5 July 1985