MAURY USCG vessel records
← All vessels

PYTHON 252

Built
2009
Last inspected
29 October 2025
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 October 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9536222
5NA2036
949500
Flag
NIGERIA
Maury page id
psix-949500

Documentation record

Tonnage as PSIX records it1596 - Convention (Subpart B), Gross Ton
2755 - Dead Weight, Gross Ton
1089 - Displacement, Gross Ton
587 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 9 other vessels inspected with it; 1 other recorded name; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 9

Inspection history · 23

29 October 2025 ISPS Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8260457
27 October 2025 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8259219
21 October 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8256652
20 October 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8256011
14 October 2025 Administrative Inspection · PSC A
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8251976
2 June 2025 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8145139
8 January 2025 MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8042014
21 November 2024 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8038323
15 July 2024 Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7958479
24 January 2024 Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7854235
20 January 2022 Drydock Exam · Damage Survey · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7382847
7 December 2021 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7368213
29 October 2020 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7086777
28 October 2020 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7086719
5 June 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6968759
22 April 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6942337
28 February 2020 Appeal
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 6917516
10 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6832406
30 September 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6824687
23 August 2019 Construction Oversight · Initial Construction-Excluding Oversight · MARPOL Annex I Examination · MTSA/ISPS Verification · MARPOL Annex VI Survey · MARPOL Annex IV Survey · MARPOL Annex II Examination · Administrative Inspection · Ballast Water Examination · COI Inspection · MARPOL Annex V Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6792432
15 July 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6750406
18 September 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6553550
25 January 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6076964

Deficiency record · 8

01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 15 October 2025 Resolved
Every oil tanker of 150 gross tons and above and every ship other than an oil tankerof 400 gross tonnage and abover shall carry on board a shipboard oil pollution emergency plan approved by the Administration. Vessel did not have an approved SOPEP from current Flag Administration. - MARPOL ANNEX 1 Reg. 37.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2025
Resolution: Vessel was provided with a stamped SOPEP.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 15 October 2025 Resolved
A Certificate, called a Safety Management Certificate, shall be issued to every ship by the Administration or an organization recognized by the Administration. The Administration or organization recognized by it shall, before issuing the Safety Management Certificate, verify that the company and its shipboard management operate in accordance with the approved safety management system. Vessel did not have approved Safety Management Certificate issued by the Administration or organization. -SOLAS 74(20) Ch.IX Reg 4.3
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2025
Resolution: Vessel was provided with a valid SMC.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 October 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements: the doors shall be self-closing and be capable of closing with an angle of inclination of up to 3.5° opposing closure. Vessel "A" class division doors were unable to fully self-close to maintain division specified on Fire Control Plan. - SOLAS 74(20) Ch.II-2 Reg. 9.4.1.1.5.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2025
Resolution: Fire doors were attested by class to be satisfatorily repaired to conform with the Fire Control Plan.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 15 October 2025 Resolved
Ships shall be fitted with a system to automatically transmit the information specified in paragraph 5. Vessel’s LRIT does not have a conformance test required by MSC.1/Circ.1307. - SOLAS 74(20) Ch.V Reg. 19-1.4.1
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Resolved 20 October 2025
Resolution: Vessel was provided with a valid LRIT Conformance Report.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 15 October 2025 Resolved
Machinery spaces of category A shall be adequately ventilated to ensure that when machinery is operating at full power in all weather conditions, an adequate supply of air is maintained to the space. Ventilation to the main machinery space was found inoperable due to a bad breaker. - SOLAS 74(04) Ch.II-1 Reg.35
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2025
Resolution: Ventilation breaker was attested by Class to be satisfactoriy repaired.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 15 October 2025 Resolved
At least three two-way VHF radiotelephone apparatus shall be provided on every passenger ship and on every cargo ship of 500 gross tonnage and upwards. Such apparatus shall conform to performance standards not inferior to those adopted by the Organization as per resolution A.809(19). Vessel did not have spare batteries for VHF radios. - SOLAS 74(20) Ch.III Reg. 6.2.1.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2025
Resolution: RO attested that emergency batteries were provided to lifeboat radios.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2025 Resolved
Fire extinguishers shall be situated ready for use, which can be reached quickly and easily at any time in the event of a fire, and in such a way that serviceability is not impaired. Portable extinguishes within the CO2 room were piled onto one another and not properly secured. - SOLAS 74(09) Ch.II-2 Reg 10.3.2.4
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2025
Resolution: Ro attested that fire extinguishers were placed in a secure fashion.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 October 2020 Resolved
No repairs or alterations to the hull or machinery, or to equipment that affects the safety of the OSV, may be made without notice to the cognizant OCMI in the inspection zone where the repairs or alterations are to be made. Vessel suffered damage to their starboard side shell and starboard fuel day tank due to collision with DB THOR (IMO-8639455) during Hurricane ZETA. Vessel currently is aground in the mud at 29.09.7N 090-3.1W at Bayou Cochon. Master/Rep shall make reports to OCMI prior to movement to Bollinger Fourchon for repairs with plans to refloat the vessel, and transit plans to include timeline of movement, towing vessels, and configurations. Point of contacts shall also be provided for the towing vessels and any vessels used in refloating the HARVEY SEAS. Timely reports shall be made to the OCMI during the process and once the vessel has safely made it to Bollinger Fourchon. Vessel is only authorized to transit to Bollinger Fourchon for repairs and shall provide the local OCMI with a damage survey and repair proposal prior to effective repairs. The local OCMI will oversee the repair process and final examination of satisfactory repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 July 2024
Resolution: Issued DD/ISE/CTIE credit on 25 JUL 2024.

Recorded names · 1

HARVEY SEAS (2020). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.