Records from 2008 to 2026. Most recent: inspection, 19 May 2026.
Documentation record
Registered dimensions (L × B × D)42.0 ft × 22.0 ft × 6.5 ft
Registered tonnagegross 40 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHIGGINS INC · NEW ORLEANS LA, UNITED STATES · built 1954
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 29 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Simplified, Gross Ton
32 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
19 May 2026
Deficiency Check · MSP Select Additional Oversight – Risk Assessment · MTSA Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8356846
14 January 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8063569
15 June 2023
Administrative Inspection · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7725686
18 July 2022
Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7507403
20 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6544895
24 May 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5886857
13 December 2011
Industry Initiated Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4208098
29 April 2011
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4004219
31 March 2010
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3715853
26 January 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3400337
20 January 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3397358
1 May 2008
DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3199559
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 May 2026
Resolved
Each integral fuel tank must have a vent that connects to the highest point of the tank, discharges on a weather deck through a bend of 180 degrees, and is fitted with a 30-by-30-mesh corrosion-resistant flame screen. MI found missing flame screen. Replace all screens and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 29 June 2026
Resolution: Received photos. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 May 2026
Resolved
When conducting an examination of a towing vessel as required by this subpart, the surveyor must determine whether any defect, deterioration, damage, or modifications of the hull and related structure and components may adversely affect the vessel’s seaworthiness or fitness or suitability for its route or service to include a visual examination of the external structure of the vessel to confirm that the condition is properly maintained. Fuel vent pipe was found with hole in it. Replave fuel vent pipe.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2026
Resolved 29 June 2026
Resolution: Received photos. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2026
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. MI found exposed circuit breakers in E/R. Enclose open breakers and label.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 29 June 2026
Resolution: Received photos. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 May 2026
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Add back-up paper charts to vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2026
Resolved 29 June 2026
Resolution: Received photos. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 May 2026
Resolved
Each towing vessel must be equippedwith navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. No day shapes where on vessel, add day shapes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2026
Resolved 29 June 2026
Resolution: Received photos. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 May 2026
Resolved
Vessels in lakes, bays, and sounds, or river service shall be fitted with such ground tackle and hawsers as deemed necessary by the Officer in Charge, Marine Inspection, depending upon the size of the vessel and the waters on which it operates.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2026
Resolution: Received photo of anchor onboard. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 September 2018
Resolved
NAME: Vsl is broadcasting incorrect Name (Letters Transposed), ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 July 2022
Resolution: AIS found to be operating properly.
Documentation › Logs/Records › Drug Test Records
Issued 31 March 2010
Resolved
Supervisors have no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 30 April 2010
Resolved 4 June 2010