MAURY USCG vessel records
← All vessels

AMECS 1

Built
1967
Last inspected
16 August 2020
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 16 August 2020
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 30 calendar years (1986–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

234031
Flag
UNITED STATES
Tonnage
641 - Regulatory (Subpart C or D), Gross Ton 641 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-234031
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

PACIFIC PATRIOT Towing Vessel · MISLE 79831 · 12 December 2019 · activity 6877313HARBOR ADMIRAL Towing Vessel · MISLE 37730 · 24 May 2016 · activity 5886857

Inspection history · 56

16 August 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7034877
12 December 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6877313
25 July 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6782736
24 May 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5886857
5 July 2012 Internal Structural Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4368842
14 February 2012 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4244260
15 July 2011 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4082544
6 July 2010 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3787531
12 January 2010 Cargo Tank Internal · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3662591
14 July 2009 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3548270
30 July 2008 MTSA Verification · Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3289770
25 October 2007 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3087172
26 September 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3066996
17 July 2007 Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2993614
5 July 2006 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2702470
6 July 2005 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2415951
9 February 2005 Internal Structural Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2289585
12 November 2004 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2239860
14 October 2004 MTSA Verification
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2220891
8 September 2004 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2191646
5 August 2004 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2161315
23 February 2004 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2012483
23 February 2004 Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2013754
18 September 2003 Periodic Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1922577
24 July 2002 Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1648929
26 September 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1418987
4 October 2000 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1451612
6 September 2000 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 822486
10 August 2000 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 821855
10 July 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1435076
8 October 1999 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1121091
5 August 1999 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 775388
21 July 1999 Re-Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440168
22 September 1998 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1392973
10 July 1998 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440032
1 October 1997 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 784427
21 August 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1452326
31 July 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1414848
11 July 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1402277
7 July 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1430086
29 August 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1177415
11 July 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1354858
21 July 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1451878
1 September 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 959132
21 July 1992 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1266080
21 July 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1356139
14 August 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1250685
14 August 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 905908
11 December 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1233049
22 November 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1229569
7 September 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 888440
31 August 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1351088
3 November 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1328793
20 October 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1324716
23 September 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1008495
3 September 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1321030

Deficiency record · 55

Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 30 July 2008 Resolved
Provide containment for fuel tank vent and fill piping prior to loading fuel. NLT 30SEP08
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 26 August 2008
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 26 September 2007 Resolved
Provide amended transfer procedures to include changes for monitoring open hatches in the transfer system description. A flame screen must be provided for any hatch that will be open during cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2007
Resolved 25 October 2007
Construction/Loadline › Hull › Hull Plating
Issued 17 July 2007 Resolved
Re-new all metal plating, sideshell, hull & structural members under .280" as indicated on the gauging report provided on 24JUL07.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2007
Resolved 7 September 2007
Resolution: All bottom and side shell hull repairs completed and tested.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 July 2005 Resolved
Replace wasted shoretie connection junction box in E/R companionway.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 9 August 2005
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 6 July 2005 Resolved
Replace wasted pump switch box on E/R aft bulkhead.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 18 August 2005
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 6 July 2005 Resolved
Install pressure-vacuum (PV) valves on all cargo tank vents, or have PV valves readily available for installation if Grade C cargo is to be carried.
Action required: 705 - Other - as specified
Due 11 August 2005
Resolved 13 July 2005
Resolution: Deficiency deleted - reduced cargo carrying authority to Grade D&E.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 5 August 2004 Resolved
Renew wasted hinge on cargo tank *8.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 8 September 2004
Deck/Cargo › Holds/Tanks › Ventilation Air Intake
Issued 5 August 2004 Resolved
Renew vent pipe for stern rake.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 8 September 2004
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 5 August 2004 Resolved
Renew hatch cover for port entrance to forward rake.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 8 September 2004
Deck/Cargo › Holds/Tanks › Coaming
Issued 5 August 2004 Resolved
Renew plugs for containment areas as needed around cargo tank vents and cargo manifold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 8 September 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 5 August 2004 Resolved
Repair wastage on vent pipe for quarters on starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 8 September 2004
Electrical › Electric Generation Source (service) › Generator
Issued 5 August 2004 Resolved
Repair starboard generator and prove operation of overspeed trips for both generators.
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 8 September 2004
Engineering › Compressed Air System (control) › Valve
Issued 5 August 2004 Resolved
Renew safety relief valve for air receiver.
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 9 September 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 August 2004 Resolved
Secure safety covers for rotating machinery in machinery space.
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 8 September 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 August 2004 Resolved
Remove daisy chained power strips in galley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 8 September 2004
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 5 August 2004 Resolved
Renew hatch cover for port void space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 8 September 2004
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 5 August 2004 Resolved
Renew top rung on ladder in port void spoce.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 8 September 2004
Electrical
Issued 6 September 2000 Resolved
Install motor controller for air compressor in engine room.
Condition: Unknown
Due 5 October 2000
Resolved 5 October 2000
Electrical
Issued 10 August 2000 Resolved
Prove proper operation of overspeed shutdowns on both generators.
Condition: Unknown
Due 10 August 2000
Resolved 10 August 2000
Accommodation/Occupational Safety
Issued 10 July 2000 Resolved
Prove proper operation of relief valve on air receiver in engine room.
Condition: Unknown
Due 10 July 2000
Resolved 10 July 2000
Electrical
Issued 10 July 2000 Resolved
Provide overcurrent protection for air compressor.
Condition: Unknown
Due 10 July 2000
Resolved 10 July 2000
Electrical
Issued 10 July 2000 Resolved
Prove proper operation of overspeed shutdown on both generators.
Condition: Unknown
Due 10 July 2000
Resolved 10 July 2000
Accommodation/Occupational Safety
Issued 21 July 1999 Resolved
Crop and renew wasted hand railing on top of house.
Condition: Unknown
Due 21 August 1999
Resolved 8 August 1999
Construction/Loadline
Issued 21 July 1999 Resolved
Crop and renew wasted unidentified pipe in #8 stbd. cargo tank forward overhead at the through hull fitting.
Condition: Unknown
Due 21 August 1999
Resolved 8 August 1999
Construction/Loadline
Issued 21 July 1999 Resolved
Make internal of stbd. integral water tank avialable for inspection.
Condition: Unknown
Due 21 August 1999
Resolved 8 August 1999
Engineering
Issued 21 July 1999 Resolved
Prove proper operation of port generator overspeed.
Condition: Unknown
Due 21 August 1999
Resolved 8 August 1999
Deck/Cargo
Issued 10 July 1998 Resolved
Repair female piping conections for overfill containment for all tanks. Fittings are corroded and don't allow positive seal when plug is installed.
Condition: Unknown
Due 28 July 1998
Resolved 30 July 1998
Construction/Loadline
Issued 10 July 1998 Resolved
Replace cover on electrical junction box for bilge pump on stbd. bulkhead.
Condition: Unknown
Due 28 July 1998
Resolved 30 July 1998
Engineering
Issued 10 July 1998 Resolved
Replace existing fuel hose from fuel tank to machinery with approve hose ormetallic piping.
Condition: Unknown
Due 28 July 1998
Resolved 30 July 1998
Deck/Cargo
Issued 10 July 1998 Resolved
Repair or submit proposal to take out of commision both 4cyl. cargo pump engines.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Lifesaving
Issued 10 July 1998 Resolved
Mark all tank covers with "DANGER KEEP OUT" in 3" letters.
Condition: Unknown
Due 28 July 1998
Resolved 30 July 1998
Deck/Cargo
Issued 10 July 1998 Resolved
Install machinery guard over port pump to engine coupling.
Condition: Unknown
Due 28 July 1998
Resolved 30 July 1998
Deck/Cargo
Issued 10 July 1998 Resolved
Update cargo tranfer diagram to reflect blank flanging and placing two cargo pumps permanently out of commission.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Construction/Loadline
Issued 21 July 1992 Resolved
Scale and remove debris from after rake, make ready for inspection. Tanks 9 and 10 are not to be used for oil recovery.
Condition: Unknown
Due 5 August 1992
Resolved 5 August 1992
Electrical
Issued 14 August 1990 Resolved
INSTALL DRIP SHIELDS OVER THE TWO BATTERY CHARGERS LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Navigation
Issued 14 August 1990 Resolved
PROVIDE AND INSTALL NAVIAGATION LIGHTS THAT MEET THE CRITERIA OF THE 72 COLREGS.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Construction/Loadline
Issued 22 November 1989 Resolved
PERMANENTLY WELD 2-INCH DRAIN LINE PENETRATION OF FORWARD CARGO PUMPROOM BULKHEAD.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Deck/Cargo
Issued 22 November 1989 Resolved
PROVIDE GUARDS FOR COUPLING ON THE FOLLOWING: GENERATOR ROOM- #3 & #4 6-71 PUMP PRIME MOVER, BILGE TRANSFER PUMP, HYDRAULIC SYSTEM COOLING PUMP. CARGO PUMP ROOM- #4 PUMP AND BILGE TRANSFER PUMP.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Construction/Loadline
Issued 22 November 1989 Resolved
REPAIR TWO BROKEN DOGS ON PORT HOLE IN HEAD.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Electrical
Issued 22 November 1989 Resolved
REPAIR WIRING IN JUNCTION BOX AT GENERATOR ROOM LADDER AND PROVIDE OUTSIDE COVER FOR SHORE TIE.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Fire Fighting
Issued 22 November 1989 Resolved
CONDUCT ANNUAL SERVICING OF ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Deck/Cargo
Issued 22 November 1989 Resolved
RESTENCIL ALL TANK TOPS "DANGER KEEP OUT."
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Accommodation/Occupational Safety
Issued 22 November 1989 Resolved
PROVIDE PLANS FOR PROPERLY DESIGNED PAINT LOCKER OR REMOVE ALL PAINT.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Deck/Cargo
Issued 22 November 1989 Resolved
STENCIL EMERGENCY FUEL SHUT-OFF AND CARGO PUMP SHUTDOWNS.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Deck/Cargo
Issued 22 November 1989 Resolved
PROVIDE RECORDS ON BARGE OF RECENT PUMP RELIEF AND PRESSURE GAUGE TESTS.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Electrical
Issued 22 November 1989 Resolved
PROVIDE PLANS FOR NEWLY INSTALLED BATTERY CHARGERS, BATTERY BANKS, AND ASSOCIATED WIRING.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Construction/Loadline
Issued 22 November 1989 Resolved
MAKE REACH ROD PASSING THROUGH CARGO PUMP ROOM OVERHEAD VAPORTIGHT AND OPERABLE, OR BLANK OFF.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Documentation
Issued 20 October 1987 Resolved
PROVIDE APPROVED OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 20 October 1987
Resolved 20 October 1987
Electrical
Issued 20 October 1987 Resolved
REPAIR LEAKY FUEL SHUT-OFF VALVES AND DEMONSTRATE.
Condition: Unknown
Due 20 October 1987
Resolved 20 October 1987
Deck/Cargo
Issued 20 October 1987 Resolved
MARK ALL CARGO TANK HATCHES "DANGER-KEEP OUT."
Condition: Unknown
Due 20 October 1987
Resolved 20 October 1987
Electrical
Issued 20 October 1987 Resolved
PROVIDE GLASS LIQUID LEVEL INDICATOR WITH MECHANICAL PROTECTION AT STBD LUBE OIL TANK.
Condition: Unknown
Due 20 October 1987
Resolved 20 October 1987
Electrical
Issued 20 October 1987 Resolved
DEMONSTRATE OPERATION OF PORT AND STBD GENERATOR OVERSPEED TRIPS.
Condition: Unknown
Due 20 October 1987
Resolved 20 October 1987
Documentation
Issued 20 October 1987 Resolved
PROVIDE VALID CERTIFICATE OF FINANCIAL RESPONSIBILTY.
Condition: Unknown
Due 20 October 1987
Resolved 20 October 1987
Construction/Loadline
Issued 20 October 1987 Resolved
REMOVE ALL PAINT FROM VESSEL OR PROVIDE AN ACCEPTABLE PAINT LOCKER.
Condition: Unknown
Due 20 October 1987
Resolved 20 October 1987
Documentation
Issued 20 October 1987 Resolved
PROVIDE EVIDENCE OF CHANGING OF ADDRESS ON CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 20 October 1987
Resolved 20 October 1987

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.