MAURY USCG vessel records Sign in
← All vessels

VISION

VISION is a 2002 unclassified. The Coast Guard has recorded 27 inspections since 2002, most recently in February 2017, along with 27 deficiencies and 4 casualty investigations between 2002 and 2012.

Records from 2002 to 2017. Most recent: inspection, 14 February 2017.

Built
2002
Last inspected
14 February 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8975823 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA8613
Flag
UNITED STATES
368265610
Maury page id
psix-38069

Inspections, by type

…with no type recorded7
Years with a record 12 calendar years (2002–2017)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it325 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
97 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDN2816MMSI 368265610 · active · compulsorily equipped · granted 1 July 2022, expires 1 July 2032
WDA8613MMSI 366856230 · expired · compulsorily equipped · granted 29 March 2012, cancelled 6 August 2022
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GRACE Passenger (Inspected) · MISLE 38068 · 31 December 2002 · activity 1747227SEABULK ST TAMMANY Freight Ship · MISLE 454931 · 31 December 2002 · activity 1747227

Inspection history · 27

14 February 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6109311
16 March 2016 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5834614
18 March 2014 Deficiency Check · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4817679
7 March 2014 Internal Structural Exam · Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4811216
24 August 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4125242
4 August 2011 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4117068
3 March 2010 Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3688414
27 March 2008 Deficiency Check · Hull Examination · Examination of Repairs · Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3172043
12 June 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2959674
12 June 2007 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2959768
29 May 2007 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2944854
12 April 2006 Examination of Repairs · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2623185
3 February 2006 Examination of Repairs · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2582247
10 August 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2455633
7 September 2004 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2200836
27 August 2004 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2178488
26 August 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2177803
29 March 2004 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2033639
3 July 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1833761
14 January 2003 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1677059
14 January 2003 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1730740
31 December 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1747227
26 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1700961
3 September 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1670158
28 August 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1670065
31 May 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1626600
14 May 2002 Hull Examination · Initial Certification · Deadweight Survey · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1616753

Deficiency record · 27

Communications › Radio Communications › VHF Radiotelephone
Issued 16 March 2016 Resolved
Emergency power for radios was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Resolution: A new battery was installed and all radios were tested using emergency power.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 March 2016 Resolved
Waterlight was not labeled with vessels name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Resolution: Crew stenciled vessel name on waterlight.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 18 March 2014 Resolved
Vent shut downs pressure switches missing 2 screws in each switch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2014
Resolution: Screws replaced 4 total.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 March 2014 Resolved
Wires not supported every 24 inches by metal clips in engine room and rudder room.
Action required: 705 - Other - as specified
Resolved 18 March 2014
Resolution: Metal clips/ wire ties placed in required areas.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 March 2014 Resolved
Overboard remote valve would not stop flow when 15 ppm indicated.
Action required: 705 - Other - as specified
Resolved 18 March 2014
Resolution: Overboard remote valve replaced, test conducted, all sat.
Fire Fighting › Ventilation Systems › Fans
Issued 4 April 2008 Resolved
Show Proper operation of ventillation remote shutdown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2008
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 27 March 2008 Resolved
Install drip shields on electrical controller boxes
Action required: 705 - Other - as specified
Resolved 8 April 2008
Electrical › Electric Supply System (service) › Cable
Issued 27 March 2008 Resolved
Install permenant electrical cable for Fuel Oil Transfer Pum[
Action required: 705 - Other - as specified
Resolved 8 April 2008
Construction/Loadline › Hull › Side Shell
Issued 12 June 2007 Resolved
Vsl has a small leak/tear in the stbd fuel tank #3 (side shell). Vsl to make repairs to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 27 June 2007
Construction/Loadline › Hull › Strut/Cross Tie
Issued 3 February 2006 Resolved
Renew or repair as original strut, strut barrel, propeller shaft, and cutlass bearings to the satisfaction of the attending marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 February 2006
Resolved 7 February 2006
Resolution: Replaced/renewed strut, strut barrel, propeller, and shaft to include cutlass bearings on port outboard side of vessel. All repairs were made to the satisfaction of the attending marine inspector.
Construction/Loadline › Hull › Hull Plating
Issued 27 August 2004 Resolved
Vessel struck buoy at sea penetrating hull in accomodation spaces. Issued PTP to Mobile, AL for repairs.
Condition: Damaged By Earlier Event
Due 27 September 2004
Resolved 7 September 2004
Electrical › Electric Generation Source (service)
Issued 7 April 2004 Resolved
Prove proper operation of the port and starboard generator overspeed shutdowns as required by 46 CFR 183.320(f). LEGACY COMPONENT DESC: Over speed shut downs
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 7 April 2004
Resolution: Witnessed the proper operation of the port and starboard generator over speed shut downs.
Electrical › Electric Generation Source (service)
Issued 7 April 2004 Resolved
Provide label proving that the port and starboard generators are designed for an ambient temperature of 50 degrees C or derate to 80 percent full load rating as required by 46 CFR 183.320(b). LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 7 April 2004
Resolution: Caterpillar technicians provided labels for the port and starboard generators proving that they are designed for an ambient temperature of 50 degrees C.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 7 April 2004 Resolved
Repair exhaust leak on the #4 main diesel engine as required by 46 CFR 182.430(b). LEGACY COMPONENT DESC: Spark Arrestor (exhaust)
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 7 April 2004
Resolution: Inspected and tested the repair to the #4 main diesel engine exhaust leak.
Accommodation/Occupational Safety › Occupational Safety
Issued 7 April 2004 Resolved
Remove all fuel from engine room bilge as required by 46 CFR 176.830(b). LEGACY COMPONENT DESC: Fuel in bilges
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 7 April 2004
Resolution: Inspected the removal of all fuel from the engine room bilge.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 7 April 2004 Resolved
Provide a schematic diagram of the CO2 system and instructions detailing alternate methods of releasing the extinguishing agent should the local manual release or stop valve controls fail to operate as required by 46 CFR 185.612(a). LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 7 April 2004
Resolution: Vessel installed a schematic diagram of the CO2 system.
Electrical › Electrical Distribution System (service)
Issued 7 April 2004 Resolved
Properly secure the M30 cable at junction box located on the port bulkhead in the ship service generator space passageway as required by 46 CFR 183.340(b)(4). LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 7 April 2004
Resolution: Inspected the proper securing of the M30 cable at junction box on the port bulkhead in the ship service generator space passageway.
Fire Fighting › Fire Pumps
Issued 7 April 2004 Resolved
Prove proper operation of the fire pump as required by 46 CFR 181.300(b). LEGACY COMPONENT DESC: Operational test
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 7 April 2004
Resolution: Inspected the installation and tested the new fire oump.
Engineering › Bilge Water Management System
Issued 7 April 2004 Resolved
Prove proper operation of the bilge pump as required by 46 CFR 182.520(a). LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 7 April 2004
Resolution: Inspected and tested the new bilge pump.
Navigation › Collision/Grounding Avoidance
Issued 7 April 2004 Resolved
Prove proper operation of the upper not under command light as required by the navigation rules. LEGACY COMPONENT DESC: NUC Lights
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 7 April 2004
Resolution: Witnessed the proper operation of the upper not under command light.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Weld several missing welds as marked in the fore peak and chain locker. LEGACY COMPONENT DESC: Weld
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 2 April 2004
Resolution: Inspected satisfactory repairs of the fore peak and chain locker.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Crop and renew fore peak suction valve reach rod. LEGACY COMPONENT DESC: Fore peak reach rod
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 2 April 2004
Resolution: Inspection the installation of a new fore peak reach rod and tested.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Gouge and weld crack located on overhead longitudinal frame outboard of port potable water tank as marked. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 2 April 2004
Resolution: Inspected the repair of the crack out board of the port potable water tank.
Construction/Loadline › Penetrations
Issued 30 March 2004 Resolved
Crop and renew fuel return line pipe collar where it penetrates the #3 starboard fuel oil tank bulkhead and air test. LEGACY COMPONENT DESC: Pipe Flange
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 2 April 2004
Resolution: Inspected the installation of a new pipe collar for the fuel return pipe penetration into the #3 starboard fuel oil tank and witnessed an air test of the #3 fuel oil tank.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Crop and renew as original the port inboard strut, starboard inboard strut, and the starboard outboard strut. LEGACY COMPONENT DESC: Strut/Cross Tie
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 2 April 2004
Resolution: Inspected the installation of new port and starboard inboard and starboard outboard struts.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Install new shaft cutlass bearings for all four shafts. LEGACY COMPONENT DESC: Cutlass Bearings
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 2 April 2004
Resolution: Inspected the installation of new shaft cutlass bearings for all four shafts.
Construction/Loadline › Hull
Issued 30 March 2004 Resolved
Remove and have both propellers re-conditioned. LEGACY COMPONENT DESC: Propellers
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 2 April 2004
Resolution: Inspected the installation of re-conditioned propellers.

Casualty record · 4

26 October 2002Routine · role: Involved in a Marine Casualty · activity 1700961
31 December 2002Routine · role: Involved in a Marine Casualty · activity 1747227
26 August 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2177803
20 October 2012Routine · role: Involved in a Marine Casualty · activity 4477096
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GULF VISION (2002–2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.