Records from 1997 to 2007. Most recent: inspection, 26 June 2007.
Inspection history · 41
26 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2974394
22 June 2007
PII Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2970597
17 April 2007
Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2909272
22 August 2006
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2756359
8 March 2006
Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2598835
18 July 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2430983
10 July 2005
Deficiency Check · Periodic Inspection
Physical examination · Activities Europe · Activity 2391360
17 February 2005
Administrative Inspection
Administrative · Activities Europe · Activity 2294303
11 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290836
27 September 2004
Administrative Inspection
Administrative · Activities Europe · Activity 2206097
29 June 2004
Type not recorded
No type recorded · Activities Europe · Activity 2293395
10 May 2004
MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2057938
8 May 2004
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Activities Europe · Activity 2026031
15 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1985892
11 November 2003
Type not recorded
No type recorded · Activities Europe · Activity 2311368
31 July 2003
Annual Inspection
Physical examination · Activities Europe · Activity 1831784
23 June 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1824493
11 April 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1822304
25 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1762748
31 December 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1747227
30 December 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1742278
12 December 2002
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1717730
24 April 2002
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1608427
18 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1606365
23 August 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1071178
11 March 2001
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451681
6 July 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1471410
19 July 1999
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1104005
9 July 1999
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1429184
13 April 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418512
9 December 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473403
24 October 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 24500
17 October 1998
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804998
15 October 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 54428
1 October 1998
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806630
30 September 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 48787
11 August 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398939
20 March 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 788318
20 February 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 45050
20 February 1998
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114865
11 June 1997
Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386021
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 22 June 2007
Resolved
Flag state endorsements for officers in accordance with STCW 95 I/2 not onboard vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2007
Resolution: Application for flag state endorsements for Chief Mate and Chief Engineer and actual Flag State Endorsement for Master were e-mailed to office.
Construction/Loadline › Markings
Issued 8 May 2004
Resolved
Permanently mark load lines. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2004
Resolved 12 June 2004
Resolution: Corrected
Documentation › Certificates/Documents › FCC SSL
Issued 8 May 2004
Resolved
Provide 2 GMDSS operators at all times. Report cleared via E-mail dated 10 Sep 04, Item remains open until cleared by attending Marine Inspector. See Activity 2206097
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2004
Resolved 10 July 2005
Resolution: Sighted GMDSS operater documents for master and Mate.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 8 May 2004
Resolved
Compass Deviation table to be updated. Report cleared via E-mail dated 10 Sep 04, Item remains open until cleared by attending Marine Inspector. See Activity 2206097
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2004
Resolved 10 July 2005
Resolution: Sighted new deviation table
Fire Fighting › Fire Hydrants › Location/Position
Issued 8 May 2004
Resolved
Fire station #13 in Engine Room port side to be moved forward 2 Frames to be more accessible. Report cleared via E-mail dated 10 Sep 04, Item remains open until cleared by attending Marine Inspector. See Activity 2206097
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 June 2004
Resolved 10 July 2005
Resolution: Sighted new locations
Engineering › Fuel Oil Service System › Valve, Control
Issued 8 May 2004
Resolved
Repair remote fuel shutoff valves from main deck. Report cleared via E-mail dated 10 Sep 04, Item remains open until cleared by attending Marine Inspector. See Activity 2206097
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2004
Resolved 10 July 2005
Resolution: Operational tested shutoff valve, Sat.
Engineering › Sea-water System (primary cooling)
Issued 8 May 2004
Resolved
Provide bracket for #3 Main Engine (Stbd inboard( for R/W discharge pipe to exhaust. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2004
Resolved 11 May 2004
Accommodation/Occupational Safety › Potable Water System › General
Issued 8 May 2004
Resolved
Repair hole in fwd water tank (weld only no epoxy material) Report cleared via E-mail dated 10 Sep 04, Item remains open until cleared by attending Marine Inspector. See Activity 2206097
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 June 2004
Resolved 10 July 2005
Resolution: Inspected and approved repair.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 8 May 2004
Resolved
Provide [name withheld] with copy of ABS Dry dock Report and Sea trails Report. LEGACY COMPONENT DESC: Class Documents
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2004
Resolved 10 July 2005
Resolution: Received copy of report. One class recommendation issue for fracture of main deck plating and has been extended to be due at Drydock 08 May 2007. Inspection note made for tracking of fracture.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 8 May 2004
Resolved
Total Number of Passenger reduced to 57 until new Lifejacket lights replaced. Report cleared via E-mail dated 10 Sep 04, Item remains open until cleared by attending Marine Inspector. See Activity 2206097
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 June 2004
Resolved 10 July 2005
Resolution: Sighted new Lights for a total of 80 Lifejackets.
Communications › Radio Communications
Issued 31 July 2003
Resolved
Vessel must have a GMDSS installed on board as per USCG MIO Europe Policy Letter dtd 09 Mar 00 (MSIB 1-00)
Due 31 October 2003
Resolved 8 May 2004
Resolution: GMDSS installed
Documentation
Issued 31 July 2003
Resolved
Ensure vessel has updated Tide and Current Tables.
Due 31 July 2003
Resolved 13 August 2003
Resolution: Received email from the Master [name withheld] attesting of corrective action.
Lifesaving › Lifejacket/PFD (Type I)
Issued 31 July 2003
Resolved
Provide and install USCG approved life jacket lights for 10 lifejackets. LEGACY COMPONENT DESC: Lights
Due 31 July 2003
Resolved 1 August 2003
Lifesaving
Issued 31 July 2003
Resolved
Ensure vessel has a rescue harness with a tag line for use in mand overboard rescues. Vessel is used as a platform
Due 31 August 2003
Resolved 26 August 2003
Resolution: Received email from the Master [name withheld] attesting of corrective action.
Engineering › Bilge Water Management System
Issued 31 July 2003
Resolved
Ensure engine room bilge alarm list functions properly.
Due 31 August 2003
Resolved 20 August 2003
Resolution: Received email from the Master [name withheld] attesting of corrective action.
Fire Fighting
Issued 11 March 2001
Resolved
PROVE PROPER OPERATION OF MAIN AND EMERGENCY FIRE PUMP.
Condition: Unknown
Due 11 March 2001
Resolved 11 March 2001
Engineering
Issued 11 March 2001
Resolved
PROVE PROPER OPERATION OF MAIN PROPULSION SYSTEM.
Condition: Unknown
Due 11 March 2001
Resolved 11 March 2001
Electrical
Issued 11 March 2001
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL ALARM FOR #1 AND #2 GENERATORS.
Condition: Unknown
Due 11 March 2001
Resolved 11 March 2001
Construction/Loadline
Issued 11 March 2001
Resolved
PROVE PROPER OPERTION OF OILY WATER SEPERATOR.
Condition: Unknown
Due 11 March 2001
Resolved 11 March 2001
Navigation
Issued 11 March 2001
Resolved
PROVIDE CURRENT COPY OF 46 CFR PARTS 166 TO 199.
Condition: Unknown
Due 11 March 2001
Resolved 11 March 2001
Construction/Loadline
Issued 9 July 1999
Resolved
MAKE REPAIRS TO 28" VERTICAL CRACK AT BOW STEM TO THE SATISFACTION OF CLASSSURVEYOR OR CG MARINE INSPECTOR PRIOR TO CONDUCTING OPERATIONS.
Condition: Unknown
Due 9 July 1999
Resolved 9 July 1999
Construction/Loadline
Issued 20 February 1998
Resolved
PROCEED DIRECTLY TO SUPERIOR SHIPYARD AND EFFECT PERMANENT REPAIRS TO DAMAGE SUSTAINED IN BOW PORTION OF VESSEL.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Fire Fighting
Issued 11 June 1997
Resolved
PROVIDE ONBOARD A FIRE DETECTION PANEL. NO PASSENGERS ALLOWED UNTIL INSTALLATION AND SAT TEST OF ALL ZONES.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Documentation
Issued 11 June 1997
Resolved
PROVIDE A VALID RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997