Records from 1992 to 1999. Most recent: operational control imposed, 20 September 1999.
Inspection history · 31
15 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 432816
9 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 432690
21 May 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 805025
18 May 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 428808
18 July 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 395813
16 July 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 393279
28 April 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 390679
16 April 1996
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 390199
21 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 386194
21 December 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 874084
6 July 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 438976
6 July 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 863299
1 July 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1439515
29 June 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 669149
19 June 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 367790
18 June 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 112360
18 March 1994
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 854548
28 February 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 364712
7 February 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 364411
22 December 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 113804
22 December 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 850730
24 November 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1447297
22 November 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 478498
22 July 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 359655
11 June 1993
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1148354
21 April 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 80675
21 April 1993
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1135994
20 April 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 357870
20 April 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 502536
1 February 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1163204
15 October 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1242678
Engineering
Issued 15 September 1999
No resolution recorded
#2 MAIN ENGINE LUBE OIL PURIFIER AND LUBE OIL COOLER DISMANTELED. MUST BE REPAIRED PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 15 September 1999 — due date passed with no resolution recorded
Documentation
Issued 15 September 1999
Resolved
OIL RECORD BOOK DOES NOT REFLECT TRANSFER OF OIL ON 14SEP99. SHIPS CREW EDUCATED ON RECORD KEEPING.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Construction/Loadline
Issued 15 September 1999
No resolution recorded
TRANSFER PIPING NOT IDENTIFIED BY CREW. CREW CONDUCTED AN UNAPPROVED, OVER THE TOP OF DECK TRANSFER OF SLOPS TO # 4 CARGO TANK. CREW MUST FAMILIARIZE THEMSELVES WITH BILGE AND SLOP OIL PROCEDURES.
Condition: Unknown
Due 15 September 1999 — due date passed with no resolution recorded
Engineering
Issued 15 September 1999
No resolution recorded
AUTO CONTROLS FOR CARGO HEATING BOILER IN CONTRO ROOM INOP. MUST BE REPAIRED PRIOR TO CARRIAGE OF CARGOS THAT MUST BE HEATED.
Condition: Unknown
Due 15 September 1999 — due date passed with no resolution recorded
Lifesaving
Issued 9 September 1999
Resolved
PORT AND STARBOARD LIFEBOAT DO NOT START WITHOUT STARTER FLUID.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Fire Fighting
Issued 18 May 1999
Resolved
CONDUCT FIRE DRILL TO THE SATISFACTION OF CG INSPECTOR
Condition: Unknown
Due 22 May 1999
Resolved 2 June 1999
Navigation
Issued 18 May 1999
Resolved
SECOND INDEPENDENT RADAR INOP.
Condition: Unknown
Due 19 May 1999
Resolved 2 June 1999
Navigation
Issued 18 May 1999
Resolved
AUTO PILOT ALARM NOT INSTALLED.
Condition: Unknown
Due 19 May 1999
Resolved 2 June 1999
Deck/Cargo
Issued 18 May 1999
Resolved
NO TEST GAS ONBOARD FOR EXPLOSIVE METER.
Condition: Unknown
Due 19 May 1999
Resolved 2 June 1999
Deck/Cargo
Issued 18 May 1999
No resolution recorded
CARGO HOSES ARE NOT MARKED, TESTED, AND CAPPED.
Condition: Unknown
Due 19 May 1999 — due date passed with no resolution recorded
Navigation
Issued 18 May 1999
Resolved
GMDSS NOT INSTALLED ONBOARD.
Condition: Unknown
Due 19 May 1999
Resolved 21 May 1999
Documentation
Issued 18 May 1999
No resolution recorded
CLASS TO ADDRESS CARGOES LISTED ON CERT OF FITTNESS REQUIRING CLOSED GAUGING, TEMPERATURE PROBES, ETC. GAUGING/TEMPERATURE SYSTEMS ARE TO BE REPAIRED IF REQUIRED FOR CARGOES ON COF.
Condition: Unknown
Due 19 May 1999 — due date passed with no resolution recorded
Engineering
Issued 18 May 1999
Resolved
PROVICE CLASS APPROVAL FOR EMERGENCY START AIR COMPRESSER INSTALLED
Condition: Unknown
Due 19 May 1999
Resolved 21 May 1999
Construction/Loadline
Issued 18 May 1999
Resolved
GENERAL SERVICE PUMP IS OUT OF SERVICE AND REMOVED.
Condition: Unknown
Due 19 May 1999
Resolved 2 June 1999
Navigation
Issued 18 May 1999
Resolved
PROVE PROPER OPERATION OF STEERING SYSTEM.
Condition: Unknown
Due 19 May 1999
Resolved 21 May 1999
Navigation
Issued 18 May 1999
Resolved
PROVE PROPER OPERATION OF STEERING LOSS OF POWER ALARMS ON THE BRIDGE.
Condition: Unknown
Due 22 May 1999
Resolved 2 June 1999
Documentation
Issued 18 May 1999
Resolved
DOCUMENT OF COMPLIANCE AND SAFETY MANAGEMENT CERT INVALID DUE TO INCORRECT OWNER/OPERATOR.
Condition: Unknown
Due 19 May 1999
Resolved 21 May 1999
Fire Fighting
Issued 18 May 1999
Resolved
EMERGENCY FIRE PUMP MISSING COUPLING GUARD.
Condition: Unknown
Due 25 May 1999
Resolved 2 June 1999
Construction/Loadline
Issued 18 May 1999
Resolved
WATER TIGHT DOOR ON STERN DECK LEADING INTO GALLEY IS WARPED AND WONT CLOSEPROPERLY._x001C_
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Construction/Loadline
Issued 18 May 1999
Resolved
WTD TO PAINT LOCKER WILL NOT CLOSE PROPERLY
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Engineering
Issued 18 May 1999
Resolved
OIL AND WATER LEAKS FROM MAIN ENGINE ARE BEING DRAINED INTO TWO 55 GAL DRUMS LOCATED AND THE FWD AND AFT END OF MAIN ENGINE. DRUMS NEED REMOVED AND LEAKS REPAIRED.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Engineering
Issued 18 May 1999
Resolved
AUTO CONTROLS FOR CARGO HEATING BOILER ARE INOP & PARTIALY REMOVED.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Deck/Cargo
Issued 18 May 1999
Resolved
INSTALLED CARGO TANK CLOSED GAUGING SYSTEM IN CARGO CONTROL ROOM INOP.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Navigation
Issued 18 May 1999
Resolved
ARPA INOPERATIVE AND MISSING COMPLIANCE STATEMENT.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Documentation
Issued 18 May 1999
Resolved
OUTSTANDING CLASS REQUIREMENTS FROM INSP FEB 98 NEED ADDRESSED.
Condition: Unknown
Due 15 October 1999
Resolved 15 September 1999
Engineering
Issued 18 May 1999
Resolved
NUMEROUS SALT WATER PUMPS IN ENGINE ROOM HAVE EXCESSIVE PACKING LEAKS
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Engineering
Issued 18 May 1999
Resolved
CEMENT PATCH ON SHIPS SERVICE GENERATOR SALT WATER PIPING AFTER SKIN VALVE.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Engineering
Issued 18 May 1999
Resolved
#2 MAIN ENGINE LUBE OIL PURIFIER AND LUBE OIL COOLER DISMANTLED.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Fire Fighting
Issued 16 July 1996
Resolved
Obtain verification of fitness of fire pump discharge valve, prior to departure from the Port of Tacoma. Bottom condition appears wasted._x001C_ Solas 60 I/11
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Engineering
Issued 16 July 1996
Resolved
Check the weld at the fwd stbd corner of the engine control room deck, prior to departure from the Port of Tacoma. Signs of minor leakage from adjacent fuel tank were noted. Solas 60 I/11
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Engineering
Issued 16 July 1996
Resolved
Make permanent repairs to the 1) leak on the boiler feed pump discharge pipe near the bilge discharge valve, 2) leaking S/W discharge cooling line for the A/C at the T-connection located above and behind the compressor L/Otank, prior to departure from the Port of Tacoma. Solas 60 I/11
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Fire Fighting
Issued 16 July 1996
Resolved
Make permanent repairs to the leak in the fire main piping in the engine room located above and to the port of the #1 L/O pump, prior to departure from the Port of Tacoma._x001C_ Solas 60 I/11
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Engineering
Issued 16 July 1996
Resolved
Make permanent repairs to leaking heavy fuel oil line for the M/E located overhead above the #1 air compressor, prior to the next U.S. port after sailing foreign. Solas 60 I/11
Condition: Unknown
Due 22 May 1999
Resolved 2 June 1999
Fire Fighting
Issued 16 July 1996
Resolved
Make permanent repairs to the wasted, leaking section of the fire main piping in the engine room, lower level, stbd side fwd, next to the_x001C_ hydrant, prior to departure from the Port of Tacoma._x001C_ Solas 60 I/11
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Construction/Loadline
Issued 16 July 1996
Resolved
Make permanent repairs to the approx. 3 mm sideshell fracture, port side atframe 52, and the 6 mm sidesell fracture, stbd side at frame 64, prior to departing the Port of Tacoma. _x001C_ ICLL 66 I/1
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Engineering
Issued 16 July 1996
Resolved
Make permanent repairs to 1) leaking F/W cooler S/W outlet pipe for #3 generator 2) patched S/W inlet line patched at the connection to the F/W cooler for the #3 generator 3) leaking and wasted tail piece of valve at port side M/E F/W cooler cover, prior to departure from Port of Tacoma.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Construction/Loadline
Issued 16 July 1996
Resolved
Maintain temporary cement box installed for the wasted and leaking F/W evaporator overboard pipe adjacent to the hull and conduct permanent repairs no later than the next scheduled drydock (April 1997)._x001C_ ICLL Annex I, I/22
Condition: Unknown
Due 30 July 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 16 July 1996
Resolved
Maintain engine room to minimize oil residue (particularly in the fuel/lube oil purifier compartment, around the M/E and the fuel/lube oil pumps), identify and correct all oil leaks, prior to the next U.S. port call after sailing foreign. Solas 60 I/11
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Engineering
Issued 16 July 1996
Resolved
Make permanent repairs to 1) rubber clamped S/W outlet line from the M/E S/W cooling pump and apparent leaking section above clamped area, 2) multiple patches on wasted filling line for heavy fuel oil outboard of transfer pump suction valve at lower engine level, fwd center. Solas I/11
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Engineering
Issued 16 July 1996
Resolved
Replace the missing sight glass on the #2 oil purifier, prior to the next U.S. port call after sailing foreign._x001C_ Solas 60 I/11
Condition: Unknown
Due 22 May 1999
Resolved 2 June 1999
Deck/Cargo
Issued 16 July 1996
Resolved
Make permanent repairs to the hydraulic leak on the anchor windlass supply/return piping, prior to the next U.S. port after sailing foreign._x001C_ _x001C_ 33 CFR 151.10
Condition: Unknown
Due 22 May 1999
Resolved 2 June 1999
Engineering
Issued 16 July 1996
Resolved
Return to proper operation the inoperative #1 L/O purifier._x001C_ Solas 60 I/11
Condition: Unknown
Due 22 May 1999
Resolved 2 June 1999
Engineering
Issued 16 July 1996
Resolved
Return to proper operation the dismantled diesel oil transfer pump, prior to the next U.S. port call after sailing foreign._x001C_ Solas 60 I/11
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Documentation
Issued 16 April 1996
Resolved
VESSEL HAD AN EXPIRED IOPP CERTIFICATE._x001C_ _x001C_
Condition: Unknown
Due 28 April 1996
Resolved 28 April 1996
Navigation
Issued 16 April 1996
Resolved
VESSELS ARPA RADAR WAS MISSING A REQUIRED LABEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 April 1996
Resolved 28 April 1996
Navigation
Issued 1 July 1994
Resolved
PROVE OPERATION OF STEERING GEAR AS REQUIRED BY SOLAS 74 II-I/29.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Electrical
Issued 1 July 1994
Resolved
CORRECT ALL FUEL LEAKS ON THE CENTER GENERATOR AND CONNECT FUEL RETURN PIPING-REMOVE BUCKETS.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Fire Fighting
Issued 1 July 1994
Resolved
PROVE OPERATION OF EMERGENCY FIRE PUMP PRESSURE FROM TWO HYDRANTS AS PER SOLAS 74 II-2/4 PRIOR TO LEAVING THE PORT OF WILMINGTON.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Deck/Cargo
Issued 1 July 1994
Resolved
PROVE OPERATION OF THE HIGH LEVEL AND OVERFILL ALARMS FOR #3 STBD AND #6 CENTER TANKS PRIOR TO LOADING CARGO.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Fire Fighting
Issued 1 July 1994
Resolved
RENEW OR PROVE SATISFACTORY CONDITION OF ALL FLEX LOOPS ON THE MACHINERY SPACE FIXED CO2 SYSTEM.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Fire Fighting
Issued 1 July 1994
Resolved
MAKE PERMANENT REPAIRS TO FIRE MAIN IN THE ENGINE ROOM AT THE FIRE PUMP DISCHARGE AND ON THE 6 INCH LINE FWD BHD PORTSIDE ENGINEROOM.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Electrical
Issued 1 July 1994
Resolved
PROVIDE CLASS SOCIETY APPROVAL OF PROPER SWITCH FOR PORT EMERGENCY CARGO SHUTDOWN.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Lifesaving
Issued 1 July 1994
Resolved
CLEAN ALL EXCESSIVE FUEL OIL AND LUBE OIL OFF PIPES AND MACHINERY IN THE ENGINE ROOM.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Documentation
Issued 19 June 1994
Resolved
OIL RECORD BOOK HAD (19) NINETEEN PAGES THAT WERE COMPLETED BUT THE MASTER DID NOT SIGN THEM.
Condition: Unknown
Due 27 December 1995
Resolved 27 December 1995
Deck/Cargo
Issued 24 November 1993
Resolved
PROVE PROPER OPERATION OFTHE #6 CENTER TANK HIGH LEVEL ALARM.
Condition: Unknown
Due 24 November 1993
Resolved 24 November 1993
Deck/Cargo
Issued 24 November 1993
Resolved
PROVIDE LOW POINT DRAIN PLUG FOR VAPOR RECOVERY SYSTEM PIPING PRIOR TO ENTRY INTO NEXT U.S. PORT.
Condition: Unknown
Due 24 November 1993
Resolved 24 November 1993
Construction/Loadline
Issued 24 November 1993
Resolved
MAKE PERMANENT REPAIRS TO EMERGENCY FIRE PUMP COMPARTMENT BULKHEAD PRIOR TOENTRY INTO NEXT U. S. PORT.
Condition: Unknown
Due 24 November 1993
Resolved 24 November 1993