Records from 1992 to 2016. Most recent: inspection, 8 August 2016.
Inspection history · 64
8 August 2016
ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5965718
13 June 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5905588
13 June 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5906528
28 December 2015
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5788100
30 October 2015
Ballast Water Examination · ISPS II Exam · PI Safety Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5752618
13 October 2014
ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5004306
16 June 2014
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4890061
1 February 2012
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4236065
7 February 2011
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3940900
10 December 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3908125
22 March 2010
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3698162
20 January 2009
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3396791
27 September 2008
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3334089
23 September 2008
Deficiency Check · Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3330481
26 June 2007
Random ISPS/MTSA-No PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2974576
26 September 2006
Random ISPS/MTSA/PSC · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2787183
12 August 2006
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2744905
3 August 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2735186
19 August 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2468309
13 June 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2389085
17 February 2005
PII Safety Exam · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2294816
10 November 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2238708
1 July 2004
NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2117964
9 June 2004
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2093519
8 December 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1961218
6 December 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1960437
15 July 2003
Ballast Water Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1849132
20 November 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1706598
27 April 2002
Re-Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1608229
21 October 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 294880
4 September 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 293496
21 April 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 277130
21 April 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 277295
18 October 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 274459
18 October 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 433896
27 July 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 110749
27 March 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 427305
8 September 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 420217
25 February 1998
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 413248
2 December 1997
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 410972
3 November 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 724964
29 October 1997
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 679781
8 August 1997
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 679782
3 July 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 56028
3 July 1997
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 405430
2 July 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 679777
16 June 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 213150
22 May 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 403865
22 May 1997
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 512114
15 April 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 90241
11 April 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 66179
22 February 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 102547
23 December 1996
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 398812
3 July 1996
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 393428
22 May 1996
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 391361
23 October 1995
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 383961
31 July 1995
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 381281
20 June 1995
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 379668
4 May 1995
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 377966
10 November 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 372130
10 November 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1429966
28 October 1993
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 361917
17 June 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 498628
20 October 1992
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 353787
Engineering › Fuel Oil Service System › Tank
Issued 30 October 2015
Resolved
2545; The ship shall comply with the requirements of the International Safety Management Code. The ship's Safety Management System section 12 included procedures to ensure and reflect how non-conformities are reported and dealt with. However, there are no guidelines that are specific for how the Master is to generate non-conformities. PSC inspectors discovered what appears See Narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 6 November 2015
Resolution: Corrected to the satisfaction of Class.
Engineering › Fuel Oil Service System › Tank
Issued 30 October 2015
Resolved
2550; The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to t proceed to sea without danger to the ship or persons on board. Ballast water supply line was found to have a soft patch. Ballast valve #111 has been disassembled and must be operated manually. See Narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 6 November 2015
Resolution: Corrected to the satisfaction of Class.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 30 October 2015
Resolved
0615; Before a ship leaves port and at all times during the voyage all life-saving appliances shall be in working order and ready for immediate use. PSC inspectors witnessed 3 unsuccessful attempts to start the port side rescue boat engine. Engine was finally able to be started satisfactory on tow subsequent attempts, 74 SOLS (97) III / 19.2, 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2015
Resolved 6 November 2015
Resolution: Corrected to the satisfaction of Class.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 30 October 2015
Resolved
Deficiency #4; 2099; The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The fuel overflow tank has been fitted with a gooseneck leading to at homemade metal container, which has a rubber hose, See Narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 6 November 2015
Resolution: Corrected to the satisfaction of Class.
Engineering › Lubricating Oil Service System › Tank
Issued 30 October 2015
Resolved
2099; The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Main Engine cylinder oil reservoir is being manually filled by the crew using a hang pump and rubber hose. The tank is being filled, See Narrative.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 6 November 2015
Resolution: Corrected to the satisfaction of Class.
Electrical › Electric Generation Source (service) › Panelboard
Issued 30 October 2015
Resolved
0950; The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Control panels for actuator and HBS-M88 Bilge maneuvering systems were found open. Modifications have been made to the panels to keep, See Narrative
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 6 November 2015
Resolution: Corrected to the satisfaction of Class.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 30 October 2015
Resolved
2035; In all ships, fire control plans shall be kept up to date, and alterations being recorded thereon as soon as practicable, Two spare accommodation spaced have been relabeled as "Training and Running Machine Room". This is not reflected on the fire control plan, 74 SOLAS (97 cons) II-2/20.1, 10c.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 30 October 2015
Resolution: Spoke with Captain and [name withheld] about keeping current fire plan in case of an emergency.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 October 2015
Resolved
2515; The captain of the port of San Francisco questions the adequacy of the implementation of the vessel's Safety Management System under the International Safety Management Code. An external audit is recommended to be conducted within 30 days, 50c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 28 December 2015
Engineering › Steering Gear System › Ram
Issued 10 December 2010
Resolved
0936; The steering gear and components shall be of sound and reliable construction. Steering gear shall be capable of putting the rudder over from 35 deg on one side to 35 deg on the other side. During operational test of the steering gear, gear was unable to move rudder to 35 deg. Once the rudder hit desired degree it would continue to "drift" or "jog" up to 5 deg. SOLAS 97 II-1/29.2.1 70(a)(b)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 December 2010
Resolved 7 February 2011
Resolution: Received class report that steering gear control system was repaired and verified by class.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 20 January 2009
Resolved
2120; Mixed garbage was found in the containers port side aft deck which is the final collection point prior to disposal into the sea. The garbage plan does not address all of the containers for garbage in the engine room and the plan does not mention the responsibilities for the collection of medical waste which is the 3rd Officers responsibility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2009
Resolved 20 January 2009
Resolution: Discussed items with the Captain and [name withheld].
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 20 January 2009
Resolved
2510; The [name withheld] is using an non-approved ballast water handling log form. The form that he is using was given to him by a representative from California. He has been using this form instead of the one issued by the company which is located in he Ballast Plan. As pre ISM he must receive permission from the company to use this form instead of the one they originally issued.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 January 2009
Resolved 22 March 2010
Resolution: Item has been corrected to the satisfaction of Class.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 20 January 2009
Resolved
0950; Approved type rubber matting is missing from the emergency generator room. Several deck lights had water in their glass globes. One of the crewmembers has renewed the starboard navigation light but did not center the light when re-installed. Causing the light to be out of focus.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2009
Resolved 20 January 2009
Resolution: All items were addressed or corrected while we were on board.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 January 2009
Resolved
0900; In the forward Bos'n store the vent ducting to the paint locker is wasted and holed. There are leaks on the hydraulic system for the mooring winches. The air vent pipe for the hydraulic system has been jury-rigged by the crew and the crew also jury-rigged the wiring system to operate the welding machine. Items need to be addressed by Class prior to the vessels return from an overseas port.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 January 2009
Resolved 22 March 2010
Resolution: Item has been corrected to the satisfaction of Class.
Lifesaving › Lifeboat › Safety Belt
Issued 20 January 2009
Resolved
0610; Some seat belts in both lifeboats are being held in place by nuts and bolts. Some have also been sewn in place by the crew. The problems with the seat belts has not been reported to the company as per the ship’s SMS requirements. Class needs to inspect this prior to the vessels return from an overseas port.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 January 2009
Resolved 22 March 2010
Resolution: Item has been corrected to the satisfaction of Class.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 September 2008
Resolved
0710 - Numerous fire doors throughout the ship have hold back hooks and some do not close properly. All hold back hooks need to be removed and all self closing fire doors need to be adjusted to ensure all doors close properly. address to the satisfaction of class society and administration.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 September 2008
Resolved 28 October 2008
Resolution: Class Report From Korean Register of Shipping confirms all doors were checked and closing devices were replaced.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Foam Source
Issued 23 September 2008
Resolved
0710 - There is no certificate for the portable foam applicator unit. Address to the satisfaction of class the effectiveness of the foam making liquid. SOLAS 74 (AM) II-2/6.4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2008
Resolved 23 September 2008
Resolution: Class Report fron Korean Reister of Shipping confirms certificate was provided by attending class surveyor.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 23 September 2008
Resolved
1705 - SOPEP is missing local port contact information. Address to the satisfaction of Class/Flag
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 September 2008
Resolved 3 November 2008
Resolution: Class report from Korean Register of Shipping confirms local port contacts provided onboard.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 23 September 2008
Resolved
2120 Garbage management plan is not being adhered to. Receptacles are not designed in accordance with the garbage management plan. Plan indicates that green cans should be used for food. Blue cans and various others are used in the galley for food. Plan dose not say what to do with Haz mat waste. Spent florescent bulbs were found in galley and provision stores.Address to the satisfaction of Class/
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2008
Resolved 3 November 2008
Resolution: Class report from Korean Register of Shipping confirms Garbage Management Plan was revised.
Lifesaving › Inflatable Liferafts › Container Construction
Issued 23 September 2008
Resolved
0628 - The containers for port/ starboard life rafts are cracked in several places. Annual service certificate states last inspection was conducted in July of 2008. Repair or replace to the satisfaction of Class at approved servicing facility.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 September 2008
Resolved 27 September 2008
Resolution: Class report received confirming the replacing of the port and starboard life rafts.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 23 September 2008
Resolved
0950 - All high voltage panels with exception of the ECR switch board do not have any non-conducting matting Provide proof by class/flag of acceptance of non-conductive matting around all switch boards.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2008
Resolved 27 September 2008
Resolution: Class report received attesting to the installation of non-conductive matting around all switch boards.
Construction/Loadline › Structures › Door
Issued 23 September 2008
Resolved
0399 - The portside door to the bridge is wasted through. no reports of non-conformity have been submitted to the company no corrective action has been taken by the crew. Address to the satisfaction of Class/Flag
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2008
Resolved 3 November 2008
Resolution: Class report from Korean Register of Shipping confirms door was replaced.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 23 September 2008
Resolved
0630 - The crew did not pass abandon ship drill due to a faulty davit. Rectify to Class/Admin
Action required: 705 - Other - as specified
Due 24 September 2008
Resolved 24 September 2008
Resolution: Lowering test of lifeboat on both sides were carried out and renewed lashing line confirmed by attending class surveyor and found in order
Operations/Management › Drills/Instruction › Fire
Issued 23 September 2008
Resolved
2020 - Crew failed to demonstrate proficiency in fire fighting procedures during two separate drills. SOLAS 74 (AM) II/2 15 III/19.3.4 ISM "A" 8
Action required: 705 - Other - as specified
Due 24 September 2008
Resolved 24 September 2008
Resolution: All crews conducted fire drill attending class surveyor and found in order.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 26 September 2006
Resolved
Garbage Record Book does not reflect any garbage taken Ashore for the past 6 months. Correct to Satisfaction of C.G.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 November 2006
Resolution: Visually inspected garbage record book and found receipts were being maintained
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 26 September 2006
Resolved
Fire Fighting Training Manual is not provided in each Crew Mess Room, Recreation Room nor in each cabin. Correct to satisfaction of C.G. SOLAS 74AM II-2/15.2.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 November 2006
Resolution: Verified fire fighting manual was provided in crews mess and recreation room.
Navigation › Collision/Grounding Avoidance › Radar
Issued 26 September 2006
Resolved
Master did not report inoperable 3-CM radar to the Coast Guard and did not request a Letter Of Deviation prior to entering San Francisco Bay.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2006
Resolution: Satisfactory repairs and testing completed prior to completion of inspection.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 26 September 2006
Resolved
Ballast Water Training is not being conducted & documented on company provided form. In addition, sediment levels are not being recorded. Correct to satisfaction of C.G.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 November 2006
Resolution: reviewed ballast water training manual and found training and sediment levels were being recorded.
Construction/Loadline › Structures › Door
Issued 26 September 2006
Resolved
Water tight door in provision stores is not water tight; Dogs cannot be firmly closed. Correct to the satisfaction of Class and or the Administration.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 November 2006
Resolution: inspected water tight door in provision stores found to be watertight and dogs were able to move freely.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 September 2006
Resolved
All A-Class doors surrounding the galley are self-closing according to the Fire Plan; Hold Back Hooks must be removed.
Correct to satisfaction of Class and or the Administration.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 November 2006
Resolution: inspected all A-Class doors surrounding galley and found all hold back hooks were removed.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 14 June 2005
Resolved
The Garbage Management Plan does not clearly reflect what the crew burns in the incinerator. The [name withheld] needs to add or delete which items are incinerated.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 June 2005
Resolved 19 August 2005
Resolution: Received copy of the garbage management plan that states only pager and rags are being incinerated.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 June 2005
Resolved
All of the lifebuoys need to be re-stenciled with the name of the vessel.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 June 2005
Resolved 19 August 2005
Resolution: Received pictures of lifebuoys with new stenciling.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 June 2005
Resolved
There are three patches on the Oily Water Separator. Two are welded patches and one has been patched using Devcon. These were done during the shipyard availability in October 2004. However, there isn't any approval documentation from Classification Society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 June 2005
Resolved 19 August 2005
Resolution: Received class report from KR stating that the OWS was inspected and the patches found in good order.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 13 June 2005
Resolved
The Ballast Water Management Plan is not ship specific. The [name withheld] needs to address number of tanks and their capacity, number of ballast pumps and their capacity, training and sampling points.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 June 2005
Resolved 19 August 2005
Resolution: Received copies of modifications made to the vessel''s Ballast Water Management Plan addressing number and capacity of tanks and ballast pumps, training of crew and sampling points.
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 November 2004
Resolved
S-Band radar inoperable. X-Band radar functioning properly. LOD rescinded upon receiving a certified technician report.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2004
Resolution: Recieved documentation verifying satisfactory repair of radar.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 9 June 2004
Resolved
Garbage Plan must be updated to include: 1) A list of materials authorized to be burned in incinerator 2) information showing designated garbage stowing areas are onboard 3) type of segregation of garbage in receptacles/cans. Crew must show compliance with the updated plan. MARPOL 73/78 annex V/9
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 August 2004
Resolution: Garbage Plan displayed all aspects to be satisfactory.
Engineering › Feedwater/Condensate Water System › Valve
Issued 9 June 2004
Resolved
The gray water overboard line has a broken valve leading to an overboard discharge line which is covered with a cement box, not approved by Class Society. Class Society must inspect repairs and fax Class report to San Francisco Bay, before vessel departs from next U.S. Port (LA/LB). SOLAS II-1/26. LEGACY COMPONENT DESC: valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 August 2004
Resolution: The gray water overboard line valve was repaired and approved by class. Corrections found to be satisfactory.
Engineering › Feedwater/Condensate Water System › Piping
Issued 9 June 2004
Resolved
The General Service Pump #2 has a "c" clamp on the discharge line, which has not been approved by Class Society. Class Report showing satisfaction with repair and/or recommendation must be faxed to MSO San Francisco Bay, prior to vessel departure from next U.S. port (LA/LB). SOLAS II-1/26. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2004
Resolved 12 June 2004
Resolution: This was repaired to the satisfaction of the Classification Representative on June 12, 2004.
Fire Fighting
Issued 27 March 1999
Resolved
Fire doors were held back with latches. Doors did not close by themselves._x001C_Corrected on the spot.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Engineering
Issued 27 March 1999
Resolved
Fuel and oil vent flame screens warped.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Lifesaving
Issued 2 December 1997
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF PORTSIDE REMOTE LIFEBOAT DAVIT BRAKE RELEASE CABLE ASSEMBLY. _x001C_ SOLAS 74 REG. III/19.2_x001C_
Condition: Unknown
Due 27 February 1998
Resolved 27 February 1998
Navigation
Issued 3 July 1997
Resolved
Vessel failed to notify USCG of radar monitor casualty. Vessel issued a Letter of Warning.
Condition: Unknown
Due 3 July 1997
Resolved 3 July 1997
Navigation
Issued 3 July 1997
Resolved
Vessel's 3cm Radar monitor is not operating properly. Vessel required to provide documentation of repair prior to departure.
Condition: Unknown
Due 5 July 1997
Resolved 3 July 1997
Lifesaving
Issued 22 May 1997
Resolved
PROVIDE WEAKLINKS FOR BOTH PORT & STARBOARD LIFERAFTS. PAINTERS ARE PERMANENTLY ATTACHED TO VESSEL. CORRECT TO SATISFACTION OF CLASS OR PROVIDE ADEQUATE DOCUMENTATION OF REPAIR.
Condition: Unknown
Due 3 July 1997
Resolved 3 July 1997
Lifesaving
Issued 22 May 1996
Resolved
LIFEBUOYS ON BRIDGEWINGS NOT AT LEAST 4KG TO OPERATE WITH QUICK RELEASE IAWSOLAS CH III PART C SECTION II REGULATION 31.7.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Lifesaving
Issued 23 October 1995
Resolved
LIGHTS ON FOUR IMMERSION SUITS WERE INOPERATIVE. ALL FOUR WERE REPLACED.
Condition: Unknown
Due 23 October 1995
Resolved 13 November 1995
Fire Fighting
Issued 4 May 1995
Resolved
FIRE MAIN DRESSLER COUPLING AT CARGO HATCH NUMBER 4 WAS LEAKING. SOLAS, CHAPTER II-1 PART A, REGULATION 4.
Condition: Unknown
Due 28 June 1995
Resolved 28 June 1995