Inspection history · 44
18 August 2026
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8467398
24 June 2026
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8412957
10 June 2026
In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8397647
9 May 2026
Administrative Inspection · Vessel Attendance
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8369753
9 March 2026
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8320361
29 October 2025
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8261454
22 September 2025
Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8238879
8 July 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8179118
14 December 2024
Appeal
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8047856
27 September 2024
Annual Inspection · Deficiency Check · Appeal
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7997842
22 November 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7828567
22 November 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7831566
28 September 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7800595
31 July 2023
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7757840
21 September 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7563906
14 July 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7507110
6 March 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7407899
31 January 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7388080
17 December 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7369092
18 August 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7290032
28 June 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7238485
13 April 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7172451
24 February 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7144002
14 January 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7123857
14 December 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7111382
11 October 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7074712
15 September 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7058194
23 August 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7038207
2 July 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6991317
31 May 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6962527
24 April 2020
Administrative Inspection · Initial Certification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6943584
8 November 2019
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6852330
27 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6524393
20 December 2012
DAPI Audit · Industry Initiated Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4504976
25 March 2010
Industry Initiated Exam · Administration
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3702684
9 February 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3414544
8 January 2009
Administration
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3391189
2 July 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2981783
20 October 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2804602
14 September 2006
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2777936
4 April 2006
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2617284
9 January 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2285933
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980960
3 July 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 56028
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2026
Resolved
A towing vessel that is: A towing vessel that is certificated for limited coastwise, coastwise, oceans, or beyond 3 nautical miles from shore,... must be equipped with: An approved 160-B semi-portable fire-extinguishing system to protect the engine room.
MI observed 160-B semi-portable extinguishing hose too short to reach the engine room.
46 CFR 142.315(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 24 June 2026
Resolution: 02 Semi-portable extinguishers with longer hoses
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 June 2026
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route.
MI observed several bolts missing from the potable water tank cover.
46 CFR 144.320(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 24 June 2026
Resolution: added new bolts and replaced other old ones.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 June 2026
Resolved
Each towing vessel must be operated in compliance with:The Maritime Transportation Security Act of 2002 (46 U.S.C. Chapter 701).
MI observed welder personnel on board who was not signed into the vessels security log book.
46 CFR 140.660(a)
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 10 June 2026
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 May 2026
Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section.
Repair corroded portions of firemain and correct leaks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 10 June 2026
Resolution: MIs attended vessel and witnessed repairs to firemain.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 May 2026
Resolved
Each towing vessel must have a means to monitor and control the amount of thrust, rudder angle, and (if applicable) direction of thrust, at each operating station.
Restore engine RPM for the bridge and the engine room for port MDE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 10 June 2026
Resolution: MIs attended vessel and witnessed RPM gagues operational.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 May 2026
Resolved
Survival craft must be stowed in accordance with the requirements of § 199.130 of this chapter, as far as is practicable on existing towing vessels.
Life raft is not stowed IAW 199.130.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2026
Resolved 24 June 2026
Resolution: Welded modified liferaft structure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 May 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Possible turbo failure on one of the main engines. Vessel operating on one main engine. Vessel shall conduct satisfactory repairs and conduct operational test to attending Coast Guard Marine Inspector prior to get underway after mooring in Jacksonville.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2026
Resolution: Replaced entire turbo/housing and tested sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 May 2026
Resolved
Vessel is required assist tug(s) of sufficient size and power to the satisfaction of the St. Johns River Bar Pilots while transiting inbound on the St. Johns River.
Action required: 705 - Other - as specified
Resolved 10 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 1 October 2024
Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. Stanchions that are utilized to support ladder and deck for entering/exiting the engine room and stanchion in forward engine room by main distribution panel are being utilized as pressure vessels. These pressure vessels are not rated IAW 46 CFR 143.300(c),cannot be properly inspected IAW 46 CFR 143.300(b), and cannot be completely drained to prevent wastage.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 30 June 2026
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 September 2024
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Fuel oil leak found in overhead above starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2024
Resolution: Tightened pipe.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 27 September 2024
Resolved
Each towing vessel must be fitted with a general alarm that has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light... Engine room general alarm is equipped with a yellow flashing light.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2024
Resolved 17 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2024
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Pressure vessel relief valves have not been tested as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2024
Resolved 17 October 2024
Resolution: Replaced valves with new
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The following deficiencies were identified:
* Top distribution panel on main switchboard has openings exposing live electrical components.
* Transformer breaker on main switchboard broken
* Back of main switchboard is enclosed with a piece of plywood.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2024
Resolved 17 October 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2024
Resolved
Electrical equipment must be marked with its respective current and voltage ratings. Distribution panels in engine room switchboard missing required markings.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2024
Resolved 17 October 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 September 2024
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Flammable liquids / aerosols found stored in engine room and on second deck.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2024
Resolved 30 September 2024
Resolution: Removed flammable liquids from vessel
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 September 2024
Resolved
Each watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT HATCH—KEEP CLOSED”. All water tight hatches on main deck missing required markings.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2024
Resolved 30 September 2024
Resolution: Labeled all hatches
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 27 September 2024
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Opening for engine room ventilator can only be secured by entering the engine room and can not be utilized in case of fire.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2024
Resolved 28 October 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 September 2024
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. On the stern of the vessel, installed bulwarks are 24" from the main deck and flush with deck above steering flat. This does not provide adequate protection to the crew.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 January 2026
Resolution: Handrails over 36 inches on the port and stbd side were installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 September 2023
Resolved
All fire-suppression and detection equipment and systems on board a towing vessel must be maintained in accordance with the attached nameplate, manufacturer's approved design manual, or as otherwise provided in any TSMS applicable to the vessel. Fire pump was excessively leaking when powered. Renew mechanical seal to prevent leaks.
46 CFR 142.240(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2023
Resolved 1 October 2023
Resolution: Mechanical seal replaced. Test Sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: No dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 28 September 2023
Resolution: Reviewed technical report and witnessed proper functionality.