Records from 2016 to 2022. Most recent: inspection, 6 March 2022.
Inspection history · 44
6 March 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7407899
14 February 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7396124
1 March 2020
ISPS Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6920223
29 February 2020
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7091023
18 February 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6910441
18 February 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6911110
9 January 2020
Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6885845
18 December 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6874060
16 December 2019
ISPS III Exam · PI Safety Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6874020
18 October 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6834710
3 September 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6802888
22 July 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6754917
14 June 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6709816
11 June 2019
Deficiency Check · ISPS III Exam · Ballast Water Examination · PI Safety Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6710934
10 June 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6709803
24 April 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6666692
17 February 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6625312
28 January 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6616141
11 January 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6609168
4 December 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6591041
2 November 2018
Ballast Water Examination · PI Safety Exam · ISPS III Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6573197
30 October 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6571225
14 September 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6540553
31 July 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6496658
22 June 2018
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6452137
18 June 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6447966
23 May 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6420421
21 April 2018
PI Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6395422
19 April 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6394709
23 March 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6377140
28 February 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6363459
22 November 2017
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6311346
20 November 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6309826
13 October 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6284114
6 October 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6282637
14 August 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6235147
5 July 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6193656
27 May 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6156865
23 March 2017
Deficiency Check · In-Service Inspection · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6110072
17 March 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6106704
20 January 2017
ISPS I Exam · PI Safety Exam · Administrative Inspection · Ballast Water Examination · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6073858
22 July 2016
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5949209
27 April 2016
ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5864083
30 March 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5843588
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 January 2022
Resolved
9101- In General- Each person who has notice of the terms of an order issued under this sub-part must comply with that order. The vessel CARIB TRADER II was found on January 12th, 2022 to be in significant non-compliance with meeting the security requirements as required by ISPS and MTSA per the COTP order issued to the vessel on 14OCT2021. Vessel did not secure access points to the vessel failing to meet the COTP order requirements.
-33CFR160.105
Action required: 10 - Deficiency Rectified
Resolved 12 January 2022
Resolution: PSCOs notified vessel agent of the expectations of the Captain of the Port Order. Agent hired private security.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 February 2021
Resolved
9101- In General- Each person who has notice of the terms of an order issued under this sub-part must comply with that order. The vessel CARIB TRADER II was found on February 19th, 2021 to be in significant non-compliance with meeting the security requirements as required by ISPS and MTSA per the COTP order issued to the vessel on 06NOV2020. Vessel did not secure access points to the vessel and had restricted spaces unsecured, failing to meet the COTP order requirements.
-33CFR160.105
Action required: 10 - Deficiency Rectified
Resolved 19 February 2021
Resolution: Vessel integrated COTP amendment 1 orders and was found to be in compliance with armed guards.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 January 2020
Resolved
Every oil fuel suction pipe from a storage, settling or daily service tank above the double bottom shall be fitted with a cock or valve capable of being close from outside outside the space concerned. The number 3 and emergency generator quick closing valves failed to close from remote location.
60SOLAS Ch.2 Reg.69(c)
Action required: 10 - Deficiency Rectified
Resolved 9 January 2020
Resolution: The Chief Engineer adjusted both quick closing valves and were tested and observed multiple times by PSCO.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 20 December 2019
Resolved
Any ship of 400 gross tonnage and above but less than 10,000 gross tonnage shall be fitted with oil filtering equipment complying with paragraph 6 of this regulation… The Administration shall have regard to the specification recommended by the Organization. Every access of the 15 PPM bilge alarm beyond the essential requirements of 4.2.8 requires the breaking of a seal. The Oil Content Meter is designed to the specifications of MEPC 107(49), but lacked the presence of a tamper evident seal.
MARPOL Annex I Regulation 14.1,
14.6, MEPC 107 (49)
Action required: 30 - Ship detained
Due 20 December 2019
Resolved 9 January 2020
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 December 2019
Resolved
Objective evidence discovered during an expanded ISM exam revealed the following nonconformities: The vessel failed to fully implement the requirements of the ISM Code through their SMS procedures as evident by the following deficiencies indicating that the ship and/or company are not meeting the SMS requirements. Recommend an external audit.
The company should establish procedures… for key shipboard operations concerning the safety of personnel, ship, and the protection of the environment. Vessel’s SMS requires Chief Engineer to “understand the measurements of gauges and instruction.” The Chief Engineer was unfamiliar with the procedures to properly record soundings as well as how to perform the operational test of the OWS and was unable to access the history of the Oil content meter as required by MEPC 107(49).
SOLAS IX/3.1 ; ISM Code Part A Reg. 7
Action required: 30 - Ship detained
Due 20 December 2019
Resolved 9 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 December 2019
Resolved
After any survey of the ship has been completed no change shall be made… without the sanction of the Administration. The main propulsion engine governor has been disconnected and is controlled manually via a nylon string.
60 SOLAS I/11
Action required: 30 - Ship detained
Due 20 December 2019
Resolved 9 January 2020
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 20 December 2019
Resolved
Every ship of 400 GT and above shall be subject to an annual survey, including a general inspection of the structure, equipment, systems, etc., to ensure they have been maintained and that they remain satisfactory. IOPP is endorsed as having oil filtering equipment with an automatic stopping device, which the equipment does not. Additionally, the IOPP is endorsed that the separating equipment is approved to Res. MEPC 107 (49), when it is approved to Res. A.393. Further, no oil residue tanks are endorsed on the IOPP.
MARPOL Annex I, 6.1.4
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2019
Resolved 9 January 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 December 2019
Resolved
Each operation... shall be fully recorded without delay in the Oil Record Book Part I, so that all entries in the book appropriate to that operation are completed. Entries in the Oil Record Book for the collection of oil residues recorded tank soundings rather than volumes onboard as specified in Appendix III.
MARPOL Annex I Regulation 17.4
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2019
Resolved 9 January 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 December 2019
Resolved
…all electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. PSCOs observed dead end wiring in two locations coming off of the emergency generator.
60 SOLAS Ch 2/27(a)(i)(1)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2019
Resolved 9 January 2020
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 14 June 2019
Resolved
10104- Gyro Compass- All Ships of 500 GT and upwards shall have...a gyrocompass being clearly readable by the helmsman at the main steering position. Vessels gyrocompass is not operational. Vessel notified company and requested technician on 12JUN19. - 74SOLAS(14Cons.) V/19.2.5.1
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 28 June 2019
Resolution: Vessel subject to requirements of 74 Solas. Vessel not required to have a gyrocompass. New certificate was issued to reflect that no gyrocompass is installed onboard.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 14 June 2019
Resolved
10104- Gyro compass- All ships of 500 GT and upwards shall have a gyro compass repeater to supply heading info to emergency steering. Repeater at emergency steering inoperable due to gyrocompass being not operational. -74SOLAS(14 Cons.) V/19.2.5.2
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 28 June 2019
Resolution: Vessel subject to requirements of 74 Solas. Vessel not required to have a gyrocompass. New certificate was issued to reflect that no gyrocompass is installed onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 June 2019
Resolved
02108-Electrical Installations In General- ...All electrical apparatus shall be so constructed and installed that danger of injury in ordinary handling shall not exist. Multiple wires in battery room were frayed and disconnected presenting electrical hazard to crew. -60SOLAS II/27(a)(i(1)
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 28 June 2019
Resolution: Wires were removed/repaired. Battery room was found in good order.
14 - Pollution Prevention › 141 - MARPOL Annex I › Standard discharge connection
Issued 14 June 2019
Resolved
14110-Standard Discharge Connection- To enable pipes of reception facilities to be connected with the ships discharge pipeline...Both lines shall be fitted with a standard discharge connection. Vessel was unable to produce standard discharge connection. Vessel states that they use a transfer hose directly into the tank to transfer oily residues. IOPP states that vessel is not provided with a standard discharge connection. -2017MARPOL Annex 1/13
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 28 June 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 28 January 2019
Resolved
The company should clearly define the master's responsibility with regard to... issuing appropriate ordersa nd instructions in a clear and simple manner; verifying that the specified requirements are observed. Master and [name withheld] gave direct orders to not stow cargo in accommodation areas and out of the way of lifesaving appliances. PSCO observed cargo stored in the aforementioned locations.
74 SOLAS (14 CONS) IX/3.1
ISM 5.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 31 January 2019
Resolved 31 January 2019
Resolution: Master held training with loading crew to assert authority to direct cargo operations and cargo was cleared out of accommodation areas and surrounding the lifesaving appliances.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangements rescue boats
Issued 28 January 2019
Resolved
All lifesaving appliances shall be kept in working order and available for immediate use before the ship leaves port and at all times during the voyage. PSCO observed cargo stored along path to bow blocking access to emergency firepump. Additionally, cargo was stored in/around the house blocking access to liferaft.
60 SOLAS III/4(c)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 January 2019
Resolved 31 January 2019
Resolution: Master had loading crew clear obscuring cargo. PSCO observed unobscured embarkation stations and weatherdecks.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 November 2018
Resolved
0999-Other(Safety In General)-All the Life-Saving appliances shall be kept in working order and available for immediate use before the ship leaves port and at all times during the voyage. Starboard life boat was not able to be launched in a timely manner. In addition, Engine room EEBD was found to be expired. 60 SOLAS 3/4(c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 November 2018
Resolved 10 November 2018
Resolution: Crew members retrained for proper operation of lifeboat davit and blockage was cleared, allowing the lifeboat to be lowered in a timely manner. EEBD replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 November 2018
Resolved
1282-Manholes Flush Scuttles-All openings in the exposed weather deck shall have coamings of ample height and strength and shall be provided with efficient means for expeditiously closing them weather tight. Maintenence cover coaming was found to be wasted and not weather tight. 60 SOLAS 2/17(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2018
Resolved 10 November 2018
Resolution: Wasted areas of the cover coaming were cut out and replaced with new steel and welded so it was weather tight.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 5 November 2018
Resolved
1680-Radio Log (Diary)-A record shall be kept to the satisfaction of the Administration and as required by radio regulations, of all incidents connected with the radiocommunication service. Monthly GMDSS test was not documented. 74 SOLAS (14)IV/17
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 10 November 2018
Resolution: PSCO verified training completed for GMDSS operators and witnessed check list placed in the GMDSS logbook to ensure no checks would be missed.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 5 November 2018
Resolved
2120-Garbage-Each discharge into the sea or to a reception facility or a completed incineration shall be promptly recorded in the Garbage Record Book. Garbage discharges to reception facilities were improperly recorded and showed CAT A, B, and C waste being incinerated. No incinerator on board. MARPOL ANNEX V 10.3.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 10 November 2018
Resolution: PSCO examined training record for master and questioned him on proper procedures to fill out the logbook correctly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 November 2018
Resolved
0999-Other (Safety in General)-A vessel owner or operator required to have a response plan shall conduct excercises as necessary to ensure that the plan will function in an emergency. The following are minimum exercise requirements for vessels: Q1 notification exercises, wihich must be conducted quarterly. Q1 quartaly notifications have not been done since DEC 17. 33 CFR 155.1060(a)(1)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 November 2018
Resolved 5 November 2018
Resolution: QI notification made
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 5 November 2018
Resolved
0925-Muster and Drills-Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire fighting systems and appliances that they may be called to use during fire drill. SCBA low on air alarmed, crew was unaware of alarm meaning and Chief Mate continued to have fire team advance to space. 74 SOLAS (14)II-2/15.2.2.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 November 2018
Resolved 5 November 2018
Resolution: Fire Drill re-ran satisfactorily
Communications › Visual Communication › Signalling Lamp
Issued 21 April 2018
Resolved
1551. All Ships of 150 gross toonage and upwards shall be fitted with a dayligh signalling lamp not solely dependent upon the ships power supply. Battery for the signalling lamp could not provide power. 74 Solas(14)V/19.2.2.2 16BC
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2018
Resolved 22 June 2018
Resolution: Vessel replaced signalling lamp and PSCO found it satisfactory
Lifesaving › Lifeboat › Propulsion Engine
Issued 13 October 2017
Resolved
0610 - All life-saving appliances shall be kept in working order and available for immediate use before the ship leaves port and at all times during the voyage. Vessel's starboard side lifeboat sail is torn and damaged. (Due to vessel's keel laid date, it is required that if it does not have an engine that it must have a sail as a means of propulsion.) - 60 SOLAS III/4(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2017
Resolved 22 November 2017
Resolution: Flag Surveyor report dated 31OCT2017 attested to the repairs of sail for lifeboat.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 13 October 2017
Resolved
1599 - From the main steering position, the horizontal field of vision extend over an arc from right ahead to at least 60 degrees on each side of the ship. Bridge visibility was obstructed by forward uppermost containers. - 74 SOLAS (14 Cons.) V/20.1.5
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 13 October 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 October 2017
Resolved
0190 - Crew members with enclosed space entry or rescue responsibilities shall participate in enclosed space entry drills to be held on board the ship once every two months. Drills were conducted once every three months. - 74 SOLAS (14 Cons) III/19.3.3
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 13 October 2017
Construction/Loadline › Hull › Hull Plating
Issued 23 March 2017
Resolved
ICLL 2005 (cons) Annex 1 Reg 1 - The Administration shall satisfy itself that the general structural strength of the hull is sufficient. Forward starboard ballast tank in cargo hold area is compromised with holes as reported by Customs Agent. Seawater is visibly flowing into the tank.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2017
Resolved 7 April 2017
Deck/Cargo › Ballast › Tank
Issued 23 March 2017
Resolved
SOLAS 60 Ch 1/10 - The hull, machinery, and equipment survey of a cargo ship shall be such to ensure that the structure is in all respects satisfactory for the service for which the ship is intended. Fuel oil and ballast tanks indicate cross-contamination of contents from undetermined source.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2017
Resolved 7 April 2017
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 February 2017
Resolved
1499 Other auxillary machinery - After any survey of the ship has been completed no change shall be made in the equipment covered by the survey without the sanction of the Administration. Batteries for the emergency generator were removed from their cradle and placed on an unstable platform in the form of two five gallon buckets. 74SOLAS(14 Cons.)CH I/Reg. 11(b) 17bc
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2017
Resolution: A steel box was installed to house the batteries.
Accommodation/Occupational Safety › Ventilation › General
Issued 25 January 2017
Resolved
0999 - Other (safety in general) - The condition of the ship shall be maintained to ensure it is fit to proceed to sea without danger to persons of board, and defects which affect safety shall be reported to the administration at the earliest opportunity. Significant exhaust leak due to wasted pipe exhaust venting into the emergency generator room - 74 SOLAS (14) Ch. I/Reg. II
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2017
Resolution: USCG Examiners verified flag attestation clearing deficiency.
Construction/Loadline › Penetrations › Weld
Issued 25 January 2017
Resolved
1299 - Other (Load Lines) - After any survey of the ship, no changes shall be made covered by the survey. The vessel conducted incomplete hull repair overhead machinery space workshop on the starboard side of vessel - ICLL 66 Article 15
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2017
Resolution: USCG Examiners verified flag attestation clearing deficiency.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 25 January 2017
Resolved
2120 - Garbage - Every ship 400 GT and above shall be provided with a Garbage Record Book and shall be in the form specified in the appendix to this annex. Vessel entries for discharge of garbage ashore in the Garbage Record Book were incomplete from April 2016 to present - MARPOL (11 Cons.) Annex V/Reg. 10.3 MEPC.201(62)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 November 2017
Resolution: Flag Surveyor letter dated 14AUG2017 attesting to the Garbage Record Book completed up to date.
Lifesaving › Lifeboat Equipment › Rocket Parachute Flare
Issued 25 January 2017
Resolved
0611 - Lifeboat Inventory - Every lifeboat shall carry four parachute signals of approved type. Lifeboat number two was found missing one parachute flare - 60 SOLAS Ch. III/Reg. II(a)(xiv)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2017
Resolution: USCG Examiners verified flag attestation clearing deficiency.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 30 March 2016
Resolved
Every ship shall be provided with a satellite emergency position indicating beacon. Vessels EPIRB is not onboard and is at servicing facility. Vessel provided order receipt. 74SOLAS(14) CH.IV/7.1.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2016
Resolution: Vessel now has EPIRB and is in working condition.
Construction/Loadline › Structures › Superstructure
Issued 30 March 2016
Resolved
In machinery spaces, two means of escape shall be provided from each engine room. The deck plate located in the engine room emergency escape route was found wasted. 60SOLAS Reg.68(ii)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2016
Resolution: The deck plate in the engine room emergency escape route has been replaced.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 30 March 2016
Resolved
Every ship when in a port of another contracting government is subject to control by oficers duly authorized by such government. Vessels Load Line certificate, SOLAS equipment, construction, and radio certificate, and International oil pollution prevention certificate are expired. 74SOLAS(14) I/19(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2016
Resolution: All required vessel certificates are now up to date.