MAURY USCG vessel records
← All vessels

JEAN RUTH

Built
1976
Last inspected
6 August 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 6 August 2026
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 21 calendar years (1992–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI9648
143700
Flag
UNITED STATES
Maury page id
psix-143700

Documentation record

Registered dimensions (L × B × D)49.4 ft × 18.0 ft × 8.5 ft
Registered tonnagegross 50 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSHERMAN SHIPYARD, INC. · PANAMA CITY, FL, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMIAMI, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 25 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 30

6 August 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8456725
3 January 2026 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8356722
17 November 2025 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8269090
2 October 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8012403
13 August 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7980369
14 August 2023 COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7767761
12 August 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7766352
29 June 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7813743
14 October 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7577167
12 October 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7332380
16 July 2021 Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7258780
15 December 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7112221
11 October 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6832695
26 June 2018 Initial Certification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6456244
29 November 2017 Industry Initiated Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6315303
16 May 2014 Industry Initiated Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4859961
9 May 2012 Administration
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4311870
6 May 2011 Administration
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4283737
10 December 2009 Administration
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3677946
29 September 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3071856
1 September 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3067285
6 December 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2835305
5 December 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 144379
26 August 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 161925
26 March 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 60880
14 March 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 51548
3 September 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 41444
24 May 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 19513
24 September 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 140579
14 February 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 160393

Deficiency record · 6

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 November 2025 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. The breaker panel in the machinery space needs to be properly labeled. 46 CFR 143.400(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2025
Resolved 19 November 2025
Resolution: Breaker panel properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 17 November 2025 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. A guard needs to be installed on the generator to protect from the hazards from the rotating belts. 46 CFR 144.820
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2025
Resolved 25 November 2025
Resolution: Protective guard installed.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 2 October 2024 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. 3 of the 4 securing devices on both the port and starboard side Watertight doors are inoperable. Repair seized dogging devices. 46 CFR 140.610
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 October 2024
Resolution: Received pictures from operator clearing deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2024 Resolved
Each distribution panel or switchboard on a towing vessel must be: Totally enclosed and of the dead-front type. Electrical panel on bridge is missing a front cover. 46 CFR 143.560
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 October 2024
Resolution: Received pictures from operator clearing deficiency.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 October 2024 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Remove standing water from starboard battery box and properly cover the generator battery box which is missing a protective case. 46 CFR 143.400 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 October 2024
Resolution: Received pictures from operator clearing deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 August 2023 Resolved
A towing vessel may not be operated without having on board a valid COI issued by the Coast Guard. Vessel was found to be in operation with current COI expired as of 20 July 2023. The renewal inspection must be completed prior to operations. 46 CFR 136.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2023

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.