Records from 2001 to 2010. Most recent: operational control imposed, 2 February 2010.
Inspection history · 175
27 January 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3670766
27 January 2010
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3671421
27 January 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3671432
22 January 2010
PI Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3654927
22 January 2010
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3668047
18 December 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3653936
24 April 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3459661
24 April 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3460118
23 April 2009
PI Safety Exam · ISPS I Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3459071
26 March 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3438667
26 March 2009
PII Safety Exam · ISPS I Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3440752
28 December 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3385767
24 December 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3384628
23 December 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3384259
15 December 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3380146
15 November 2008
PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Deficiency Check · Loadline Exam · ISM Exam · ILO-147 Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3363952
21 September 2008
PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3329424
18 September 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3327568
12 August 2008
NPV Safety Exam · PII Safety Exam · Administrative Inspection · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3296853
21 July 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3274741
30 June 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3253080
28 June 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3250357
29 May 2008
MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PI Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3221024
26 May 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3217930
8 May 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3201563
8 May 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3205515
1 April 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3175315
29 March 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3173528
22 March 2008
Type not recorded
No type recorded · Station Fort Pierce · USCG Southeast District (CGD-SE) · Activity 3169302
19 March 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3167840
22 October 2007
MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3084370
1 September 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3067285
15 October 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2800876
13 October 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2799798
3 October 2006
MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2792387
18 July 2006
Type not recorded
No type recorded · Maritime Safety & Security Team Miami (91114) · Activity 2716874
17 July 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2715650
3 July 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2699458
8 May 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2647825
6 May 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2642423
24 April 2006
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2632726
22 April 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2630820
16 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2603789
27 February 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2592794
17 February 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2587460
31 January 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2576960
30 January 2006
Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2575810
30 January 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2576295
30 January 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2576338
21 January 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2570464
5 January 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2561560
14 December 2005
ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2551150
10 December 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2548034
8 December 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2548438
4 November 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2528261
15 October 2005
PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2515132
13 October 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2513903
6 October 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2508928
29 September 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2510038
26 September 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2501957
7 September 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2487472
30 August 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2479567
28 August 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2476840
18 August 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2466450
16 August 2005
PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2464538
9 August 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2457098
8 August 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2456282
6 August 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2453478
27 July 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2466463
26 July 2005
PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2440633
19 July 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2431706
15 July 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2448031
6 July 2005
PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2417060
2 July 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2425118
21 June 2005
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2397641
16 June 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2392279
16 June 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2392492
14 June 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2389866
3 June 2005
Random ISPS/MTSA/PSC · PI Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2378042
1 June 2005
PI Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2375530
23 May 2005
Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2366647
23 May 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2373841
21 May 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2363960
6 May 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2353088
3 May 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2348346
23 April 2005
PI Safety Exam · ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2340477
16 April 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2337454
12 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2332644
25 March 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2326592
21 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2316120
11 March 2005
MARPOL Annex I Examination · PI Safety Exam · MARPOL Annex V Examination · Random ISPS/MTSA/PSC
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2307871
5 March 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2304283
1 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2301816
18 February 2005
PI Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2295256
18 February 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2295277
14 February 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2302623
12 February 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2291154
14 January 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2302681
12 January 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2273667
30 December 2004
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2266712
20 December 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2262527
18 December 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2261650
8 December 2004
PI Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2255724
26 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2248760
25 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2247838
22 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2246004
19 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2244618
4 November 2004
PI Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2234708
13 October 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2219991
10 October 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2217511
26 September 2004
PI Safety Exam · Random ISPS/MTSA/PSC
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2205194
19 September 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2199251
17 September 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2198377
18 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2169613
16 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2167615
30 July 2004
PII Safety Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2150112
30 July 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2150282
27 July 2004
Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2146327
16 July 2004
ISPS II Exam
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2135201
15 July 2004
PI Safety Exam
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2139320
6 July 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2123599
28 June 2004
PI Safety Exam
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2113992
21 June 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2106191
19 June 2004
Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2103368
7 June 2004
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2091320
1 June 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2085046
28 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2080999
16 May 2004
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2068890
14 May 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2071079
11 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2064783
10 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2063891
19 April 2004
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2047652
11 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2042312
10 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2041341
24 March 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2054294
23 March 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2029543
6 March 2004
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2019497
2 February 2004
Periodic Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1999056
25 January 2004
Periodic Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1992426
14 January 2004
Periodic Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1983827
9 January 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1980972
19 November 2003
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1950814
4 November 2003
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1941861
3 October 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1920482
2 September 2003
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1894435
7 August 2003
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1902124
31 July 2003
Periodic Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1863465
21 July 2003
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1853001
3 July 2003
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1834411
27 June 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1828451
20 May 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1797664
6 May 2003
Deficiency Check · Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1787507
3 May 2003
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1806951
2 May 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1784842
2 May 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1784957
2 May 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1784978
10 April 2003
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1771984
18 March 2003
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1758864
27 January 2003
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1735873
14 December 2002
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1719378
8 December 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1715979
26 November 2002
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1711069
25 November 2002
Type not recorded
No type recorded · GROUP BOSTON · USCG Northeast District (CGD-NE) · Activity 1756337
19 November 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1708057
7 November 2002
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1704333
2 November 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1699845
18 October 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1691943
26 September 2002
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1680631
26 September 2002
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1680919
22 September 2002
Type not recorded
No type recorded · USCGC VIGOROUS (WMEC 627) · Activity 1679745
20 June 2002
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1635469
4 June 2002
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1625929
18 January 2002
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1479914
24 November 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 295724
2 November 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 295140
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 27 January 2010
Resolved
Main shaft seperated from the shaft stop link causing the shaft to slip out resulting in flooding throught the shaft seal. SOLAS 60 Ch.1 Reg11
Action required: 705 - Other - as specified
Resolved 6 February 2010
Resolution: Received flag state survey report attesting to repair of the shaft and seal.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 27 January 2010
Resolved
Vessel lost anchor in Port Everglades Anchorage
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2010
Resolved 8 February 2010
Resolution: Received flag state inspection report attesting to proper installation of two anchors onboard.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 24 December 2009
Resolved
Daytime signalling lamp onboard does not have a proper electrical connection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 December 2009
Resolved
Lifeboats are in need of nonskid covering the exterior embarkation deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2010
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 24 December 2009
Resolved
Lights are 8 years expired or are not present..
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2010
Resolution: Vessel rep came to secotr to show lights, and also purchase order.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 24 December 2009
Resolved
Original not onboard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2010
Stability › Watertight Integrity › General
Issued 24 December 2009
Resolved
Cargo loading door in aft section of shp missing gaskets and not able to close by a2 inch gap.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2010
Stability › Watertight Integrity › General
Issued 24 December 2009
Resolved
Port side hawsing pipe leaking water from exterior by means of deteriated temporary patch allowing water intrusion into forepeak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2010
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 24 December 2009
Resolved
there is a pipe running from the dirty bilge tank to the ows overboard discharge. Vessel must remoe immediately
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2010
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 24 December 2009
Resolved
Rudder angle indicator is off by 10 - 15 degrees between the bridge and the emergency steer control station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2010
Documentation › Certificates/Documents › IOPP Certificate
Issued 24 December 2009
Resolved
Current IOPP Suppelmental Form does not reflect specification of the OWS, Oil Content Meter on board and correct maximum throughput. Provide certificate with actual specfications. MARPOL 73/78 Annex I Reg 7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2010
Personnel › Certificates/Documents/Licenses › License, Master
Issued 24 December 2009
Resolved
Contracting governments undertake for it's national ships that all ships be sufficiently manned. Vessel does not have a master or second engineer onboard in accordance with the minimum safe manning document. Solas 2004 cons. V/14.1, 17(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2010
Resolution: Vessel rep came to sector to show valid flag state endorsements for master and 2AE.
Lifesaving › Immersion Suits › Not on Board
Issued 24 December 2009
Resolved
An immersion suit complying, with the requirements of section 2.3 of the code shall be provided for every crewmember. All crew does not have and immersion suit. Solas 2004 cons III/7.3, 17(b)(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2010
Resolution: Vessel rep came to sector and showed proper immersion suits.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 24 December 2009
Resolved
The cargo ship safety equipment certificate shall be issued in compliance with the relevant requirements of chps II-1, II-2, III, and V. The cargo ship safety equipment record of equipment does not reflect the relevant regulations and the vessel is not outfitted in accordance. Solas 2004 cons I/12(a)(iii)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2010
Resolution: Vessel rep came to sector so show updated Safety Equipment cert.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2009
Resolved
A cement patch has been employed to stop sea water from entering the vessel through the hull in the lower cargo hold on the starboard side. This patch is evidence that the hull is not of sufficient structural strength for the draught corresponding to the freeboard assigned. Action taken 30(b).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2009
Resolution: Received administrative report for deficiency, and the boarding team verified that deficiency has been corrected.
Fire Fighting › Automatic Sprinkler System › Piping
Issued 23 April 2009
Resolved
A temporary patch has been placed on a water service pipe in the sprinkler system in the upper cargo hold amidships on the starboard side. Action taken 17(b).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2009
Resolution: Received administrative report for deficiency, and the boarding team verified that deficiency has been corrected.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 26 March 2009
Resolved
Main engine common fuel pipe to high pressure pumps between #5 and #6 High pressure pump is an unapproved temporary repair. Provide flag attestation to proper repair.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2009
Resolution: Received survey from administration stating deficiency has been rectified.
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 March 2009
Resolved
Main engine raw water heat exchanger is holed and wasted in three places. Provide flag state attestation to proper permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2009
Resolution: Received survey from administration stating deficiency has been corrected.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 26 March 2009
Resolved
Main engine high pressure fuel pump pipes are not jacketed . Provide flag state attestation to permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2009
Resolution: Received survey from administration stating deficiency has been rectified.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 18 November 2008
Resolved
Port Anchor hawse pipe at deck level has hole due to chain chaffeage. Make repairs as to class approval. ICLL 66, Annex I/1 17(a)(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2008
Resolution: Repairs were made as to class and CG marine inspector''s approval.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 18 November 2008
Resolved
Hole in Class 'A' division bulkhead forward/port between engine room and lower cargo hold has been altered and is no longer in compliance with structural fire protection regulations. SOLAS 60 Ch. 2 Reg. 38 70(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 March 2009
Resolution: Corrected class A division bulkhead.
Construction/Loadline › Hull › Hull Plating
Issued 18 November 2008
Resolved
Make repairs to patch located in forepeak, starboard side, deck level to approval of class. SOLAS 60 Ch. 1 Reg. 11 17(a)(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2008
Resolution: Repairs were made as to class and CG marine inspector''''s approval.
Construction/Loadline › Markings › Load Line Mark
Issued 15 November 2008
Resolved
VESSEL HAD PARTS OF THE HULL REMOVED AND A STEEL PLATE PATCHES PLACED THAT COVERED THE LOAD LINE MARKINGS. LOAD LINE DOES NOT MATCH CERTIFICATE. PLIMSOL WAS INTACT. DEFICIENCY MUST BE RECTIFIED TO SATISFACTION OF CLASS.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2009
Resolution: Received class report indicating deficiency has been corrected.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 15 November 2008
Resolved
CONTAINMENT AROUND DAY TANK FUEL VENT IS WASTED THROUGH. RECTIFY TO SATISFACTION OF USCG.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 March 2009
Resolution: Containment around tank replaced and corrected.
Lifesaving › Launching Appliances › Davit
Issued 15 November 2008
Resolved
RESCUE BOAT DAVIT LIMIT SWITCH BRAKET WAS BROKEN. LIMIT SWITCH WAS UNABLE TO BE CONTACTED AND DAVIT WAS UNABLE TO STOP PRIOR TO FULL SECURED POSITION. RECTIFY TO SATISFACTION OF CLASS.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 April 2009
Resolution: Received class report stating deficiency has been corrected.
Stability › Watertight Integrity › General
Issued 15 November 2008
Resolved
Bulkhead between the main deck cargo hold and fore peak is waisted through near deck of space. Rectify to satisfaction of class and USCG.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2008
Resolution: Wasted bulkead was repaired to satisfaction of class and USCG marine inspectors.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 November 2008
Resolved
Bulkhead around chain locker wasted with holes. Rectify to satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2008
Resolution: Holes were repaired to satisfaction of class.
Construction/Loadline › Structures › Deck Plating
Issued 15 November 2008
Resolved
Forward of deck between the forepeak and forepeak tank wasted with a hole. Rectify to satisfaction to class and USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2008
Resolution: Hole was repaired to satisfaction of class and USCG marine inspector.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 18 September 2008
Resolved
NTVRP has not been submitted IAW title 33 USC part 1321 (j)(5).
Action required: 15 - Rectify deficiencies by next port
Resolved 19 September 2008
Resolution: Received notice from the Vessel Response Plan webpage www.e-vrp.com that the vessel is now in a "pending status". The COTP order is now rescinded.
Construction/Loadline › Structures › Deck Plating
Issued 12 August 2008
Resolved
Vessel's lower cargo hold watertight deck plating is excessively worn causing sea water leaks from the ballast tank. In addition, sea water is leaking through 03 plate access covers from the ballast tank into the lower cargo hold. Provide report from Flag/Administration approving temporary repairs and addressing a permanent solution.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2008
Resolution: Received Flag report approving temporary repairs and addressing a permanent solution.
Construction/Loadline › Hull › Bottom Plating
Issued 12 August 2008
Resolved
Vessel provided document detailing temporary repairs conducted by divers to 04 holes and 02 cracks on the outer hull in way of #4 center ballast tank below water line. Provide report from vessel Flag/Administration approving temporary repairs and addressing a permanent solution.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2008
Resolution: Recieved Flag report approving temporary repairs and addressing permanent solution.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 August 2008
Resolved
Unapproved 110 volt wiring and splicing was discovered in various crew cabins, thus creating a potential fire hazard. Vessel must replace/repair current configuration to the satisfaction of the administration.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2008
Resolution: Vessel removed current configuration to the satisfaction of the administration. USCG boarding team went on board to verify and recieved Flag report approving current configuration.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 12 August 2008
Resolved
The International Safety Management Manual is not written in a language understood by the vessel Master. Vessel shall provide a copy of the ISM Manual in the working language of the Master.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2008
Resolution: Recieved Flag report addressing ISM issues. Chief mate is designated as Designated Person On board in regards to the safety management system.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 29 May 2008
Resolved
Provide written proof of annual servicing for portable fire extinguishing appliances.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2008
Resolved 10 June 2008
Resolution: Received certificate of inspection from Fire Protections Plous, INC.
Lifesaving › Inflatable Liferafts › Servicing
Issued 29 May 2008
Resolved
Provide written proof of annual survicing for liferafts.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2008
Resolved 10 June 2008
Resolution: Received certificate of re-inspection from Survitec group for the inflatable liferafts.
Engineering › Steering Gear System › Follow-up Assembly
Issued 29 May 2008
Resolved
Conduct steering gear test. While onboard steering gear system was inop due to maintenance.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2008
Resolved 10 June 2008
Resolution: Installed repaired solenoid and successfully tested the steeing system.
Engineering › Bilge Water Management System › Piping
Issued 22 October 2007
Resolved
Bilge piping is deteriorating and needs to be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2007
Resolution: Received faxed copy of surveyor report attesting to the repairs.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 22 October 2007
Resolved
Main switchboard covers need to be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2007
Resolution: Received faxed copy of surveyor report attesting to the repairs.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 3 October 2006
Resolved
Emergency fire pump has a severe exhaust leak creating an operational hazard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2006
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 3 October 2006
Resolved
Unable to test emergency fire pump due to exhaust leak
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2006
Lifesaving › Rescue Boat › Construction
Issued 3 October 2006
Resolved
Vessel purchased a new rescue boat and the admin has not approved the operational condition of the boat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2006
Fire Fighting › Fire Pumps › Cylinder Barrel
Issued 30 January 2006
Resolved
Emergency fire pump engine has a blown head gasket and not able to be started. Demonstrate proper operation of the emergency fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2006
Resolution: Witnessed operation while onboard.
Construction/Loadline › Hull › Stringer
Issued 30 January 2006
Resolved
Frame #52 starboard side lower deck, has frame wasted at the deck. Make repairs to the satisfaction of Class prior to next US Port after going foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 February 2006
Construction/Loadline › Markings › Load Line Mark
Issued 30 January 2006
Resolved
Paint the load line deck reference mark.
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 27 February 2006
Resolution: Received copy of new Load Line Certificate issued on 20FEB06 and approved by surveyor.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 13 October 2005
Resolved
vessel did not provide advance notice of arrival before entering COTP providence zone.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2006
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 3 June 2005
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 17 June 2005
Resolved 16 June 2005
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 3 June 2005
Resolved
Emergency Fire Pump unable to provide pressure to supply fire main. Prove proper operation of Emergency Fire Pump, to the satisfaction of USCG Inspector, prior to departing COTP NY.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2005
Resolved 4 June 2005
Resolution: Vessel repaired emergency fire pump and proved its proper operation to the satisfaction of USCG Inspector.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 11 March 2005
Resolved
A review of the notice of Arrival found that the vessel did not properly list accurately the last five (5) ports. Properly provide update to National Vessel Movement Center of last ports, prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2005
Resolved 14 March 2005
Operations/Management › Drills/Instruction › Fire
Issued 11 March 2005
Resolved
Crew was not to demonstrate a satisfactory fire drill, conduct satisfactory fire drill in the presence of the USCG.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2005
Resolved 11 March 2005
Resolution: A second drill was conducted satisfactory.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 March 2005
Resolved
During the abandon ship drill found the sea painter, and frapping lines tangled. Makes lines in port lifeboat ready for immediate service.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2005
Resolved 11 March 2005
Resolution: Lines were properly stowed.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 11 March 2005
Resolved
Emergency fire pump missing guard over shaft, provide guard over shaft to the satisfaction of the attending Classification Surveyor.
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 23 April 2005
Resolution: Guard has been provided.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 11 March 2005
Resolved
Exhaust for emergency fire pump is leaking excessively into the forepeak area. Repair the exhaust leak to the satisfaction of the attending Classification Surveyor.
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 23 April 2005
Resolution: Exaust leak in forepeak area has been resolved with repair.
Lifesaving › Lifeboat › Non-skid Surface
Issued 11 March 2005
Resolved
Wooden decking is wasted, in port lifeboat. Port State Control Officer broke through wooden deck. Make repairs to the satisfaction of the attending Classification Surveyor.
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 23 April 2005
Resolution: Adequate repairs have been made to port lifeboat.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 11 March 2005
Resolved
Starboard side skin valve for the sewage system is not closing properly. Blank of this line until a new valve can be properly installed.
Action required: 15 - Rectify deficiencies by next port
Due 15 March 2005
Resolved 23 April 2005
Resolution: New valve has been installed.
Lifesaving › Launching Appliances › Block
Issued 11 March 2005
Resolved
Port forward lifeboat block is twisted and makes it difficult to properly attach frapping lines. Reverse block 180 degrees.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2005
Resolved 11 March 2005
Lifesaving › Inflatable Liferafts › Servicing
Issued 11 March 2005
Resolved
Prior to departure provide service report for liferaft.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2005
Resolved 14 March 2005
Resolution: Received liferaft service report.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 8 December 2004
Resolved
Continuous Synopsis Record (CSR) list, that the vessel has no Document of Compliance. Vessel document issued by PMDS. Provide proof that (CSR) has been sent to Flag Administration for amendment.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2004
Resolved 9 December 2004
Resolution: Received confirmation that the vessel has submitted amendment for the CSR.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 8 December 2004
Resolved
2nd Officer, Aslan Baiazit, has no Panama STCW endorsement, provide proof that application has been submitted to Flag.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 8 December 2004
Resolution: Flag Administration faxed a copy of application.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 8 December 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 8 December 2004
Resolution: Flag faxed endorsement application.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 8 December 2004
Resolved
Demonstrate proper operation of emergency fire pump. Fire pump did not have significant pressure. Demonstrate to the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2004
Resolved 8 December 2004
Resolution: Before leaving vessel, they demonstrated proper pressure.
Operations/Management › Vessel Traffic Service › Reporting Requirements
Issued 8 December 2004
Resolved
Notice of arrival did not include an accurate count of the last five (5) ports. Captain provided an accurate count of the last ten (10) ports while on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 8 December 2004
Resolution: Captain provided an accurate list of last ten (10) ports while on board.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 November 2004
Resolved
Remove fresh water flush line running into oil monitoring device. Permanently remove valve from fresh water line and remove hose from cap on monitoring device used to releive pressure.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2004
Resolved 10 November 2004
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 30 July 2004
Resolved
Renew gasket from air scavanger to #3 cylinder, solas 74/78 II 26.1. Repair crack in air scavenger in the vicinity of #4 cylinder, Solas 74/78 II 26.1. Repair to the satisfaction of administration/ or surveyor acting on behalf of administration prior to next US port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 August 2004
Resolution: Repaired crack in air scavenger in th vicinity of #4 cylinder.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 15 July 2004
Resolved
Fuel oil containment is inadequate. A hole was cut in the containment barrier to allow a pipe to pass through the containment area. The containment does not meet the regulations of 1/2 barrel due to this.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 July 2004
Engineering › Compressed Air System (control) › Piping
Issued 15 July 2004
Resolved
A crack was observed in the air scavenger piping in the vacinity of the #4 Cylinder.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 July 2004
Engineering › Steering Gear System › Solenoid Valve
Issued 15 July 2004
Resolved
Minor hydraulic leak on steering gear solenoid valve. Vessel must repair leak.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 July 2004
Engineering › Compressed Air System (control) › Valve
Issued 15 July 2004
Resolved
Replace gasket from air scavenger to #3 cylinder.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 July 2004
Construction/Loadline › Penetrations › Gasket
Issued 28 June 2004
Resolved
Replace gaskets on the following doors and hatches; Main cargo hatch, engine room hatch from vehicle deck, STBD aft WTD, port forepeak air vent.
Condition: Improper/Lack of Maintenance
Due 12 July 2004
Resolved 15 July 2004
Resolution: Replaced gaskets on the above doors and hatches.
Fire Fighting › Fire Hoses › Location
Issued 28 June 2004
Resolved
Exchange fire hoses for potable water hoses. Fire hoses must be dedicated solely to fire stations and conspicuously located.
Condition: Placed in Improper Service
Due 12 July 2004
Resolved 15 July 2004
Resolution: Vessel bought new firehose to increase amount of hoses onboard.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 28 June 2004
Resolved
Replace and update deviation card for magnetic compass. Improper date was placed on card.
Condition: Improper/Lack of Maintenance
Due 12 July 2004
Resolved 15 July 2004
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 28 June 2004
Resolved
Install threaded cap on potable water tank in engine room.
Condition: Improper/Lack of Maintenance
Due 12 July 2004
Resolved 15 July 2004
Resolution: Installed threaded cap on potable water tank in engine room.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 28 June 2004
Resolved
Install non-conductive matting at switchboard. Also install non-conductive railing.
Condition: Improper/Lack of Maintenance
Due 12 July 2004
Resolved 15 July 2004
Resolution: Installed non-conductive matting and railing at switchboard.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 14 May 2004
Resolved
Vessel has been screened and is identified as a priority 1, this condition poses a potential hazard to the port of New York. Vessel must complete a Port State Control boarding prior to entering the Port of New York.
Action required: 705 - Other - as specified
Resolved 17 May 2004
Resolution: Vessel completed a Port State Control exam and cleared to enter Port.
Construction/Loadline › Hull
Issued 4 November 2003
Resolved
Repair drainage holes in lower aft hold, no later than 25 NOV 03, or in lieu of repair provide class attestation to the satisfactory drainage in lower hold.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 November 2003
Resolved 11 March 2004
Resolution: Cleared.
Construction/Loadline › Structures
Issued 2 September 2003
Resolved
Make Permanent repairs to wasted frames in lower cargo deck upon vessels return to BOSMS or NLT 10SEP03.
Condition: Improper/Lack of Maintenance
Due 10 September 2003
Resolved 11 March 2004
Resolution: Cleared.
Construction/Loadline › Structures
Issued 2 September 2003
Resolved
Make Permanent repairs to wasted bulkhead located in lower cargo hold under cargo ramp starboard side aft. Make repairs upon return to BOSMS or NLT 10SEP03. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Due 10 September 2003
Resolved 11 March 2004
Resolution: Cleared.
Electrical › Electrical Distribution System (service)
Issued 31 July 2003
Resolved
Provide cover for junction box on portside aft bulkhead on ro-ro deck. Have the flag state or certificate issuing authority address ventilation near the junction box. LEGACY COMPONENT DESC: Junction Box
Due 15 August 2003
Resolved 7 August 2003
Fire Fighting › Miscellaneous Items
Issued 31 July 2003
Resolved
Adjust door to firefighting dear locker on starboard boat deck. Door is hard to open making access to fire fighting equipment difficult.
Due 15 August 2003
Resolved 7 August 2003
Personnel › Certificates/Documents/Licenses
Issued 6 May 2003
Resolved
None of the crew had Panamanian Endorsements or could provide proof of application. LEGACY COMPONENT DESC: STCW Endorsement
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2003
Fire Fighting › Emergency Fire Pumps
Issued 6 May 2003
Resolved
Provide safe access to the forward area where the anchor windless and emergency fire pump is located, area is blocked by vehicles. LEGACY COMPONENT DESC: Location
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2003
Navigation › Collision/Grounding Avoidance
Issued 6 May 2003
Resolved
Starboard running light has clear lens with green cellophane paper as a diffuser. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2003
Fire Fighting › Fire Hydrants
Issued 6 May 2003
Resolved
Fire station #16 blocked by equipment. LEGACY COMPONENT DESC: Location/Position
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2003
Construction/Loadline › Structures
Issued 6 May 2003
Resolved
Bottom of chain locker is wasted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2003
Pollution Prevention/Response
Issued 6 May 2003
Resolved
When emergency fire pump was started, charged hose sprayed a sheen of oil, also a overboard for pump discharge a additional sheen of oil. Vessel to determine cause of sheen of oil.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2003
Construction/Loadline › Structures
Issued 6 May 2003
Resolved
Hatch cover for lower level located forward port side is missing securing bolts. LEGACY COMPONENT DESC: Manhole
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2003
Pollution Prevention/Response › Prevention Equipment
Issued 10 April 2003
Resolved
NEEDS AUDIBLE ALARM INSTALLED. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 6 May 2003
Navigation
Issued 10 April 2003
Resolved
2 GLASS WINDOWS ON THE BRIDGE ARE SHATTERED FROM UNKNOWN CAUSE. THE MASTER STATED THAT THEY WOULD BE REPLACED UPON THEIR ARRIVAL IN PORT EVERGLADES IN FT. LAUDERDALE, FL. LEGACY COMPONENT DESC: 2 BRIDGE GLASS WINDOWS
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 May 2003
Construction/Loadline › Markings
Issued 18 March 2003
Resolved
Loadline and draft markings on hull need to be pained in contrasting colors to the color of the hull. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 April 2003
Resolved 10 April 2003
Resolution: LOADLINE IS NOW PROPERLY PAINTED ON VESSEL.
Engineering › Generator (propulsion-electric)
Issued 26 November 2002
Resolved
Properly replace machinery gurads to both generators in way of belts and pulleys. LEGACY COMPONENT DESC: Belt Guards
Condition: Unknown
Due 26 December 2002
Resolved 14 December 2002
Fire Fighting › Fire Pumps
Issued 26 November 2002
Resolved
Make satisfactory repairs to leaking valve on emergency fire pump day tank. LEGACY COMPONENT DESC: valve
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2002
Resolved 27 November 2002
Resolution: repaired temporarily using Liquid Teflon sealing compound.
Construction/Loadline › Structures
Issued 26 November 2002
Resolved
Replace/repair all Gaskets for all weathertight./watertight doors, aft cargo ramp, and main deck cargo ramp as needed, LEGACY COMPONENT DESC: Door
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 22 January 2003
Accommodation/Occupational Safety › Potable Water System
Issued 26 November 2002
Resolved
Makeproper repairs to potable water line behind STBD side Sewage tank.
Condition: Unknown
Due 26 December 2002
Resolved 14 December 2002
Construction/Loadline › Structures › Door
Issued 7 November 2002
Resolved
Replace gasket on weather tight door on port side of superstructure leading to main deck.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 9 November 2002
Resolved 8 November 2002
Resolution: Replaced gasket with new.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 7 November 2002
Resolved
Properly repair or replace stern tube packing for main propeller shaft due to excessive leakage.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 9 November 2002
Resolved 8 November 2002
Resolution: Tightened shaft packing gland and reduced leakage.
Operations/Management › Mandatory Ship Reporting Systems
Issued 18 October 2002
Resolved
Failed to provide required advance 24 hour notice of arrival LEGACY COMPONENT DESC: Advance notice of arrival
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2002
Resolved 26 November 2002
Resolution: deficiency cleared.
Lifesaving › Lifebuoys
Issued 27 September 2002
Resolved
Evenly distribute, through out the vessel, all the ring buoys that are all located on the bridge deck. LEGACY COMPONENT DESC: Stowage
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2002
Stability › Weathertight Integrity
Issued 27 September 2002
Resolved
Hatch cover leading into the forecastle is missing securing bolts, install all bolts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2002
Pollution Prevention/Response › Prevention Equipment
Issued 27 September 2002
Resolved
Oil containment around vents is being used a stowage for paint and other items. Clean out all containments.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2002
Deck/Cargo › Cargo Stowage
Issued 26 September 2002
Resolved
Vessel to provide a Cargo Securing Manual (CSM). CSM onboard does not match the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2002
Resolution: Received Class approval.
Lifesaving › Lifeboat Equipment
Issued 26 September 2002
Resolved
Replace the boat oars in starboard lifeboat, present oars are broken and have mushrooms growing on them. LEGACY COMPONENT DESC: Oar
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2002
Lifesaving › Lifeboat Equipment
Issued 26 September 2002
Resolved
Replace the boat hooks in starboard lifeboat, present hooks are broken and have mushrooms growing on them. LEGACY COMPONENT DESC: Boat Hook
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2002
Lifesaving › Lifeboat
Issued 26 September 2002
Resolved
Apply retro reflective tape to bottom of lifeboats. LEGACY COMPONENT DESC: Markings
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2002
Fire Fighting › Fire Main
Issued 26 September 2002
Resolved
Repair fire main starboard main car deck, line is ruptured. Rupture is approximately half way back of car deck. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2002
Personnel › Manning/Qualifications
Issued 26 September 2002
Resolved
Provide proof of proper manning. First engineer's Panamanian endorsement is for a Second Engineer and the Second Officer has no Panamanian endorsement. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2002
Engineering
Issued 26 September 2002
Resolved
Remove excess oil from the engine room bilge and provide receipts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2002
Fire Fighting › Emergency Fire Pumps
Issued 26 September 2002
Resolved
Emergency fire pump is not easily accessible. The location of the emergency fire pump is up forward and is blocked by loaded cars. Remove cars. LEGACY COMPONENT DESC: Location
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2002
Construction/Loadline › Structures
Issued 26 September 2002
Resolved
Chain locker covers are missing, reinstall the covers. LEGACY COMPONENT DESC: Door
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2002
Documentation › Certificates/Documents
Issued 26 September 2002
Resolved
Provide proof of last two dry dockings. LEGACY COMPONENT DESC: Cargo Ship Safety Construction Certificate
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 September 2002
Fire Fighting › Structural Fire Protection - General
Issued 26 September 2002
Resolved
Flag authority to approve the location of the paint stores that is located under the starboard lifeboat.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 October 2002
Fire Fighting › Structural Fire Protection - General
Issued 26 September 2002
Resolved
Flag authority to approve the location of the paint stores that is in the same space as the emergency fire pump.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 October 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 26 September 2002
Resolved
Wipe up all the oil in and around the emergency fire pump space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 26 September 2002
Resolved
Install coupling guard fro the emergency fire pump. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 September 2002
Engineering › Sea-water System (primary cooling)
Issued 26 September 2002
Resolved
Repair the piping for the seawater intake for the #1 ships service generator. Present pipe has soft patches and is holed and leaking. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2002
Engineering › Sea-water System (primary cooling)
Issued 26 September 2002
Resolved
Repair the piping for the seawater intake for the main diesel engine. Present pipe has soft patches made of coffee cans and duct tape. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2002
Engineering › Fuel Oil Service System
Issued 26 September 2002
Resolved
Fuel oil separator cover is held in place by a jerry-rigged bar. The installed wing nuts are broken. Vessel to make proper repairs to the securing devices.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 October 2002
Electrical › Lighting (service)
Issued 26 September 2002
Resolved
Remove the household lights above the shaft in the lower level of the aft engine room. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 October 2002
Stability › Watertight Integrity
Issued 26 September 2002
Resolved
Hatch cover is open leading to the lower hold in main car deck. Hatch cannot be closed due to the securing chain in way. Chain was relocated while onboard and hatch is able to close.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2002
Fire Fighting › Fire Hydrants
Issued 26 September 2002
Resolved
Crew has removed the fire hydrant on the lowest vehicle deck starboard side. Crew to reinstall. LEGACY COMPONENT DESC: Location/Position
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 October 2002
Fire Fighting › Grease Extraction Hood
Issued 26 September 2002
Resolved
Clean out the entire galley exhaust duct. Ducting is full of grease.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2002
Lifesaving › Liferaft Equipment
Issued 26 September 2002
Resolved
Provide inspection report tube for lifeboats in accordance with the LSA Code 4.2.7.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 November 2002
Resolution: Deficiency cleared.
Fire Fighting › Miscellaneous Items
Issued 26 September 2002
Resolved
Clean areas around all fire fighting equipment. Fire fighting equipment blocked by propane bottles, cylinders of oxygen and acetylene, and containers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2002
Operations/Management › Drills/Instruction
Issued 26 September 2002
Resolved
Crew is to demonstrate proper fire and boat drill prior to departing Port of New York. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2002
Operations/Management › Vessel Safety Management
Issued 26 September 2002
Resolved
Vessel to make non-conformity report to Antartida Marine Corp. Vessel is to provide copy of report to the Coast Guard. This should also include the correspondence back from Management Company. LEGACY COMPONENT DESC: Reports and Analysis
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2002
Fire Fighting
Issued 26 September 2002
Resolved
Flag authority to examine the fire control plans and ensure that the plans are in accordance with SOLAS.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 November 2002
Resolution: Deficiency cleared
Lifesaving › Lifeboat
Issued 26 September 2002
Resolved
Some of the sheaves on the port lifeboat davit do not roll. Vessel to make permanent and proper repairs and demonstrate proper lowering of port lifeboat to the satisfaction of the Flag.
Action required: 15 - Rectify deficiencies by next port
Resolved 26 November 2002
Resolution: Deficiency cleared
Lifesaving › Lifeboat
Issued 26 September 2002
Resolved
Wire falls on the port lifeboat slide against the davit when being lowered and is being chaffed. Flag surveyor to examine the clearance of the falls against the davit arm.
Action required: 15 - Rectify deficiencies by next port
Resolved 26 November 2002
Resolution: Deficiency cleared
Accommodation/Occupational Safety
Issued 2 November 2001
Resolved
PROPERLY LABEL AND PLACARD MARINE SANITATION DEVICE IAW 33 CFR 159.51 AND 159.59.
Condition: Unknown
Due 3 November 2001
Resolved 18 January 2002
Construction/Loadline
Issued 2 November 2001
Resolved
MAKE PERMANENT REPAIRS TO LOAD LINE IN REGARDS TO RAISING OR INDENTING MARKS IAW ICLL ANNEX 1 REG 8.
Condition: Unknown
Due 25 November 2001
Resolved 25 November 2001
Electrical
Issued 2 November 2001
Resolved
PROVIDE COVERS FOR 220 V. ELECTRICAL CABLES ON SECOND CARGO DECK IAW SOLAS 60 CHAP. 2 REG 27(a)(ii)(1).
Condition: Unknown
Due 3 November 2001
Resolved 18 January 2002
Electrical
Issued 2 November 2001
Resolved
PROVIDE LIGHT COVERS FOR LIGHT FIXTURES THROUGHOUT VESSEL IAW SOLAS 60 CHAP. 2 REG 27(a)(i)(1).
Condition: Unknown
Due 3 November 2001
Resolved 18 January 2002
Electrical
Issued 2 November 2001
Resolved
PROVIDE GUARDS TO BACK OF MAIN ELECTRICAL SWITCHBOARD IAW SOLAS 60 CHAP 2 REG 27 (a)(ii).
Condition: Unknown
Due 25 November 2001
Resolved 25 November 2001