Records from 1985 to 2024. Most recent: inspection, 6 February 2024.
Inspection history · 96
6 February 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7861586
1 October 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3860927
29 September 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3860159
5 September 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3836705
26 March 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3702493
2 February 2010
Type not recorded
No type recorded · USCGC SHAMAL (WPC 13) · Activity 3679525
5 May 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3466978
5 May 2009
ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3467881
16 March 2009
ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3434063
29 January 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3401063
29 January 2009
ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3401559
8 December 2008
ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3376483
4 December 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3374060
3 December 2008
ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3372588
1 December 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3372220
26 October 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3352095
23 October 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3350280
24 September 2008
PI Safety Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3331591
23 September 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3330768
23 September 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3330985
13 September 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3325157
10 September 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3322036
24 July 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3282160
21 July 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3275133
28 April 2008
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3194015
18 April 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3187289
18 April 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3191136
25 March 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3172030
20 March 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3168554
14 January 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3130376
14 January 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3130834
13 January 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3129591
28 November 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3105664
21 November 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3102245
20 November 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3101702
11 October 2007
Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3077720
10 October 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3077443
18 September 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3060311
7 September 2007
MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3051581
23 May 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2938727
4 April 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2901526
14 March 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2889272
30 January 2007
PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2863815
25 July 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2724216
12 July 2006
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2710604
12 April 2006
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2623270
23 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2608389
29 November 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2542767
18 November 2005
Deficiency Check · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2536927
2 July 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2411291
29 June 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2408118
26 June 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2404204
13 April 2005
PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2333063
2 March 2005
ISPS I Exam · PI Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2302196
1 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2301272
11 December 2003
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1961671
19 September 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1908354
16 September 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1906069
4 August 2003
Administrative Inspection · Periodic Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1866107
30 July 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1861852
1 July 2003
Deficiency Check · Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1831931
15 May 2003
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1793884
9 April 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1771037
31 January 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1738004
29 January 2003
Type not recorded
No type recorded · USCGC BLUEFIN (WPB 87318) · USCG East District (CGD-E) · Activity 1736803
27 January 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1735733
3 January 2003
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 1725996
27 November 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1711575
26 November 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1711135
28 October 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1697352
25 October 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1696207
24 July 2002
Administrative Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1651184
13 May 2002
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1616204
23 October 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 294625
20 September 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 293598
5 December 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 397947
3 October 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 396645
28 June 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 392692
15 June 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 526590
26 May 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 391642
4 May 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 513286
22 February 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 388208
31 July 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 381140
17 July 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 532641
24 May 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 19513
11 May 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 378293
1 April 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 648324
10 August 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 353222
19 October 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 648325
12 August 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 454554
5 April 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 343038
10 October 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 318964
6 July 1986
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 309989
10 April 1986
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 308064
11 December 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 471909
1 July 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 302975
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 30 December 2008
Resolved
Provide proper STCW Certifications for Chief Mate
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2009
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 30 December 2008
Resolved
Provide proper STCW Certifications for Chief Engineer
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2009
Resolution: Received faxed copy of chief engineers liscences, endorsements and approved application for STCW.
Personnel › Certificates/Documents/Licenses › STCW Certificate, Navigation Watch Rating
Issued 30 December 2008
Resolved
Provide STCW Certification for an additional AB for regulation II/4. Carlile Reid is acceptable for meeting one of two Deck Ratings Required.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2009
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 8 December 2008
Resolved
Master does not have Flag endorsement for position and GMDSS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 8 December 2008
Resolved
Chief Mate does not have Flag State endorsement for GMDSS. Provide Flag State endorsement for GMDSS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 8 December 2008
Resolved
Provide Flag State endorsement for Chief Engineer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2008
Resolution: This office received Confirmation of Receipt for Flag State endorsement.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 8 December 2008
Resolved
Provide Flag State endorsement for Second Engineer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 December 2008
Resolved
Fire and Abandon Ship drills are not being conducted monthly.
Action required: 705 - Other - as specified
Due 7 January 2009
Resolved 18 December 2008
Stability › Watertight Integrity › Coaming
Issued 8 December 2008
Resolved
A 26"x18" hole exists on starboard side coaming between cargo holds #4 and #5. Provide Flag State report attesting to repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 8 December 2008
Resolved
Starboard side emergency battery enclosure is wasted and needs to be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 December 2008
Resolved
Replace Fire Control Plan on Port Side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 8 December 2008
Resolved
The ship's Aldis lamp is inoperable. Provide Flag State report attesting to the proper operation of the Aldis.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Personnel › Certificates/Documents/Licenses › MMD, Able Seaman
Issued 8 December 2008
Resolved
Does not obtain a STCW Certificate for that position.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2008
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 8 December 2008
Resolved
Port side Anchor and chain are missing. Provide anchor and chain to the satisfaction of Flag
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 24 September 2008
Resolved
Lighting fixtures (2) and wiring in hold #6 damaged due fire.
Action required: 705 - Other - as specified
Due 10 October 2008
Resolved 24 September 2008
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 24 September 2008
Resolved
Marine fire caused damage to cargo hold. Vsl to have flag state attest to damage and structural integrity of cargo holds.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2008
Resolution: Flag state report received; noted that "only paint and smoke damage" but no structural damage.
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 April 2008
Resolved
ACCUMULATOR BATTERIES SHOULD BE SUITABLY HOUSED, AND COMPARTMENTS USED PRIMARILY FOR THEIR ACCOMODATION SHOULD BE PROPERLY CONSTRUCTED AND EFFICIENTLY VENTILATED. (CCSSC,CH.2,PART E,2.27.9.2)
Action required: 705 - Other - as specified
Resolved 26 June 2008
Engineering › Feedwater/Condensate Water System › Pump
Issued 28 April 2008
Resolved
MOVING PARTS OF MACHINERY WHICH ARE EXPOSED TO CAUSE ACCIDENTS SHOULD BE PROPERLY GUARDED. (CCSSC,CH.2,PART B,2.12.6)
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2008
Resolved 26 June 2008
Stability › Weathertight Integrity › General
Issued 28 April 2008
Resolved
6 CARGO HATCH COVERS ARE HOLED AND WASTED. GASKETS ARE ALSO MISSING AND DETERIORATED ALLOWING WATER TO ENTER INTO CARGO HOLD. (ILLC 66/2005, ANNEX I, REG. 15)
Action required: 705 - Other - as specified
Resolved 26 June 2008
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 28 April 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 26 June 2008
Documentation › Certificates/Documents › International Load Line Certificate
Issued 28 April 2008
Resolved
INTERNATIONAL LOADLINE CERTIFICATE DOES NOT HAVE ANNUAL ENDORSEMENT. (ILLC 66/2005, ART 19)
Action required: 705 - Other - as specified
Resolved 26 June 2008
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 28 April 2008
Resolved
CARIBBEAN CARGO SHIP SAFETY CERTIFICATE DOES NOT HAVE ANNUAL ENDORSEMENT.
(CCSSC,CH.1,PART B,1.10)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2008
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 28 April 2008
Resolved
RECOMEND THIRD PARTY ISM AUDIT. (REFERENCE DEFICIENCIES 5,6,7,8) (SOLAS 74,CH IX, REG 5;
ISM CODE)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2008
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 14 January 2008
Resolved
Vessel failed to provide accurate crew list as required in 33 CFR Part 160, Subpart C. This is a significant element required to be submitted with the Advance Notice of Arrival.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 January 2008
Stability › Watertight Integrity › General
Issued 11 October 2007
Resolved
Forward bulkhead of cargo bay #1 has visible wasted areas measuring 2-3 inches on deck. Provide report from flag state explaining the cause of water in void space #8.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2007
Resolution: Received Flag report verifying repairs were made.
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 7 September 2007
Resolved
Chief Mate did not have a GMDSS endorsement from Flag State.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 7 September 2007
Resolved
Excessive oily waste in the engineering spaces. The waste must be pumped from the engine room by an approved disposal company. Provide receipt to USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2007
Resolution: Vsl provided receipts for oily waste removal. Inspectors verified work in engine room walk thru.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 September 2007
Resolved
Replace sea water cooling pipe for #3 ships service diesel generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2007
Resolution: Pipe was replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2007
Resolved
Missing light covers in engine room space.
Due 14 September 2007
Resolved 20 September 2007
Resolution: Light covers were replaced
Lifesaving › Visual Distress Signals (General) › Expired
Issued 7 September 2007
Resolved
Expired SART battery.
Due 14 September 2007
Resolved 20 September 2007
Resolution: New battery was purchase and SART was in compliance with regs.
Stability › Weathertight Integrity › General
Issued 7 September 2007
Resolved
Weather tight integrity of all hatch covers wasted. Weather stripping missing, and/or improperly maintained
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2007
Resolution: #4 Hatch cover was replaced and all holes were patched and tested by hose for weather tight integrity satisfactory
Navigation › Piloting/Steering › Compass Deviation Table
Issued 14 March 2007
Resolved
Compass deviation table not posted on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2007
Resolved 4 April 2007
Resolution: CG visually inspected
Navigation › Piloting/Steering › Marine Charts
Issued 14 March 2007
Resolved
Charts on bridge have not been corrected.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2007
Resolved 4 April 2007
Resolution: CG visually inspected
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2007
Resolved
Exposed wiring and electric cords run throughout galley and overhead.
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 4 April 2007
Resolution: CG visually inspected
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 March 2007
Resolved
Missing panel on main switchboard in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2007
Resolved 4 April 2007
Resolution: CG visually inspected
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 30 January 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2007
Resolved 22 February 2007
Resolution: New chief engineer onboard has valid license/endorsement for position.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 30 January 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2007
Resolved 22 February 2007
Resolution: Proof of endorsement from flag provided.
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 30 January 2007
Resolved
SECOND ASSISTANT ENGINEER DOES NOT POSESS A VALID MEDICAL FITNESS DOCUMENT.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2007
Resolved 22 February 2007
Resolution: Valid medical certificate provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 12 July 2006
Resolved
Flag admin to attend and verify proper operation of ME and submit report to CG. Surveyor must submit authorizaion to act upon behalf of Flag Admin. Prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2007
Resolution: Recieved survey from flag attesting to proper repairs to Maine Engine.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 12 July 2006
Resolved
Vsl to complete and submit CG 2692 regarding ME fire and failure prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2007
Resolution: CG inspectors verified 2692 submitted to CG.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 12 April 2006
Resolved
Vessel does not have enough food on board to feed the crew while underway. Provide sufficient food for crew prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2006
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 7 December 2005
Resolved
The following forms do not have the correct company address for container shipping terminal inc: ISSC, continuous synopsis record, safety management cert, document of compliance, and ship security plan. also, list correct phone number for CSo in ship security plan. Make proper corrections.
Action required: 15 - Rectify deficiencies by next port
Resolved 12 April 2006
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 7 December 2005
Resolved
Provide new Caribbean Cargo Ship Record of Equipment and ship information form.
Action required: 15 - Rectify deficiencies by next port
Resolved 14 March 2007
Resolution: CG inspectors conducted PSC exam and verified all documents are in compliance with regulations.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 29 November 2005
Resolved
Vessels safety management certificate expired. Full Term certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2005
Resolution: Vessel has been issued a full term SMC.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 29 November 2005
Resolved
Vessel is not to permitted to conduct cargo operations after 1 January, 2006, until a drydock has been completed.
Action required: 705 - Other - as specified
Due 1 January 2006
Resolved 14 March 2007
Resolution: CG inspectors recieved copy of drydock report onboard vessel.
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 18 November 2005
Resolved
Provide medical certificate for oiler.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2005
Resolution: Oiler has a valid medical certiifcate.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 18 November 2005
Resolved
EPIRB is inoperable repair/replace battery for proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2005
Resolution: Replaced battery in EPIRB.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 November 2005
Resolved
Resupply first aid kit for ship.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2005
Resolution: First aid kit re supplied.
Navigation › Piloting/Steering › Marine Charts
Issued 18 November 2005
Resolved
Update and correct all charts onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2005
Resolution: Charts are up to date.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 November 2005
Resolved
Provide updated Light List
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2005
Resolution: Light list up to date.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 29 June 2005
Resolved
Vessel sumbitted NOA on 25 JUN 05 w/ incomplete vessel security information. Issued COTP Order denying entry to U.S. waters. Vessel failed to comply with COTP Order and entered U.S. waters.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 November 2005
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 13 April 2005
Resolved
Vessel does not have a valid SMS. Provide schedule for the implementation of SMS approved by the Administration.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Engineering › Steering Gear System › Ram Seal
Issued 13 April 2005
Resolved
Stearing Gear Pumps leaking and have no form of containment.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Electrical › Electric Generation Source (service) › Generator
Issued 13 April 2005
Resolved
No. 1 Generator has a lube oil leak and containment is full of oil. Renew leaking oil line.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 April 2005
Resolved
No. 3 Generator's seawater cooling line is wasted and holed. Crop and renew.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 April 2005
Resolved
Main seawater line after seachest valve on the port and starboard side is wasted. Crop and renew.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 April 2005
Resolved
Vessel has no record of conducting drills within the last month. Conduct drills and provide records.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2005
Resolved 27 April 2005
Lifesaving › Lifeboat Equipment › Food Ration
Issued 13 April 2005
Resolved
Ten or more food rations on port and starboard lifeboats (twenty or more total) are not sealed properly. Provide replacement food rations.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 13 April 2005
Resolved
Two CO2 fire extinguishers are no charged. Recharge and provide service report.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Lifesaving › Lifeboat › Hull
Issued 13 April 2005
Resolved
Port side lifeboat has a 4" X 2" hole. Make permanent/proper repairs to hole.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Fire Fighting › Means of Escape › Blocked
Issued 13 April 2005
Resolved
Both Engine room emergency exits are padlocked from the outside. Provide locking mechanism that allows escape.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Deck/Cargo › Cargo Stowage › General
Issued 13 April 2005
Resolved
Vehicles loaded as cargo are not properly drained of fuel, making them HAZMAT. Vehicles must be removed and drained of gasoline.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 13 April 2005
Resolved
AB seamen has expired medical certificate. Provide new certificate with valid med exam.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 13 April 2005
Resolved
Engineering officer has expired medical certificates. Provide new certificate with current med exam.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Deck/Cargo › Cargo Stowage › General
Issued 13 April 2005
Resolved
Cargo is not loaded IAW the Cargo Securing Manual. Have flag State attest to the use of ratchet straps as securing devices.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Personnel › Training › Familiarization Training
Issued 13 April 2005
Resolved
Provide training to bridge personell on the operation of the AIS. Provide record that training has conducted.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2005
Resolved 27 April 2005
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 2 March 2005
Resolved
Vessels 500 GT and above required to have ISM on board. SMC and DOC not present.
Due 2 April 2005
Resolved 18 November 2005
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 2 March 2005
Resolved
Master, Chief Mate, and 3rd Engineer not in possesion of flag state STCW 95 Endorsements.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 March 2005
Fire Fighting › Fire Main › Condition
Issued 2 March 2005
Resolved
Fire main piping holed and wasted near pump discharge.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 November 2005
Lifesaving › Inflatable Liferafts › Not on Board
Issued 2 March 2005
Resolved
Vsl required inflatable liferaft on port and starboard side of vsl due to raft on starboard side is not readily transferable on the same single deck.
Action required: 15 - Rectify deficiencies by next port
Resolved 12 April 2006
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 2 March 2005
Resolved
Vsl flag state registry and tonnage certificates all display varying tonnages. Provide proper and correct certificates prior to entry of US port. Unable to determine if vsl is CCSSC or SOLAS applicable vessel.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 March 2005
Lifesaving › Rocket Parachute Flares › General
Issued 2 March 2005
Resolved
Vsl missing two approved flares on bridge.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 December 2003
Resolved
Oily water seperator not functional. Repair or remove unit to the satisfaction of the certificate issuing authority no later than 10 Jan 04. Retain all oily bilge water on board with the exception to discharge to an approved reception facility, until repairs can be made. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 18 November 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 10 December 2003
Resolved
Remove and/or correctly terminate dead-end wiring throughout ship. I.E. In engine room and workshop.
Due 10 January 2004
Resolved 18 November 2005
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 10 December 2003
Resolved
Vessel's oil transfer procedures records not satisfactory. Correct and prove proper record-keeping NLT 10 FEB 04.
Action required: 705 - Other - as specified
Due 10 February 2004
Resolved 18 November 2005
Lifesaving › Lifeboat Equipment
Issued 4 August 2003
Resolved
Food rations in lifeboats have become airborne (4 stbd & 5 port). Replace all nine with new rations. LEGACY COMPONENT DESC: Food Ration
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2003
Resolution: Cleared on Board, CK
Lifesaving › Inflatable Liferafts
Issued 4 August 2003
Resolved
Hydrostatic release improperly installed on liferaft. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2003
Resolution: Cleared on Board, CK
Accommodation/Occupational Safety › Occupational Safety
Issued 4 August 2003
Resolved
Remove all oil on deck in way of forward ground tackle.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2003
Resolution: Cleared on Board, CK
Electrical › Lighting (service)
Issued 4 August 2003
Resolved
Electrical instillations in cargo hold are unsafe. Properly install all lights with permanent wiring and provide covers for each light.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 September 2003
Resolution: Cleared on board, CHK
Stability › Watertight Integrity
Issued 4 August 2003
Resolved
Properly and permanently repair all wasted vent pipes around cargo hatches.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2003
Resolution: Cleared on Board, CK
Pollution Prevention/Response › Prevention Equipment
Issued 4 August 2003
Resolved
Containment around fuel vents on both sides of cargo hatches improperly installed. Provide permanent containment. LEGACY COMPONENT DESC: Fixed Containment
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2003
Resolution: Cleared on Board, CK
Accommodation/Occupational Safety › Occupational Safety
Issued 4 August 2003
Resolved
remove oil from deck within motor room (fwd).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2003
Resolution: Cleared on Board, CK
Deck/Cargo › Holds/Tanks
Issued 4 August 2003
Resolved
Excessive wastage throughout cargo holds and cargo hatches. Provide flag state surveyors report addressing overall condition of holds and hatches. Numerous bulkheads, frames, and pipes observed wasted with holes.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 September 2003
Resolution: Cleared on Board, CHK
Pollution Prevention/Response › Prevention Equipment
Issued 4 August 2003
Resolved
Pump all oily bilge water ashore to proper reception facility and provide receipts. LEGACY COMPONENT DESC: oily bilges
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2003
Resolution: Cleared on Board, CK
Construction/Loadline › Penetrations
Issued 4 August 2003
Resolved
Provide flag state surveyors report addressing Chief engineer's documentation that there is a rising level of water in engine room bilges. C/E suspects possible free communication between aft peak tank and bilges.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2003
Resolution: Cleared on Board, CK
Engineering › Bilge Water Management System
Issued 4 August 2003
Resolved
Properly repair severely wasted bilge well suction piping for the aftermost bilge well located on the port side of the aft cargo hold. LEGACY COMPONENT DESC: Piping
Action required: 15 - Rectify deficiencies by next port
Resolved 18 September 2003
Resolution: Cleared on Board, CHK
Engineering › Fuel Oil Service System
Issued 4 August 2003
Resolved
Properly install metallic flame shields below the RAYCOR fuel filters located on the port side of the engine room, forward. Remove bucket full of fuel from below the fuel filters. LEGACY COMPONENT DESC: Filter
Action required: 15 - Rectify deficiencies by next port
Resolved 11 December 2003
Engineering › Freshwater System (jacketwater cooling)
Issued 4 August 2003
Resolved
Salt water piping to main engine, holed and wasted. Make permanent and proper repairs to the satisfaction of the attending USCG. LEGACY COMPONENT DESC: Piping
Action required: 15 - Rectify deficiencies by next port
Resolved 18 September 2003
Resolution: Cleared on Board, CHK
Engineering › Freshwater System (jacketwater cooling)
Issued 4 August 2003
Resolved
Salt water piping and hoses to generators, holed and wasted. Make permanent and proper repairs to the satisfaction of the attending USCG. Marine Inspector. LEGACY COMPONENT DESC: Piping
Action required: 15 - Rectify deficiencies by next port
Resolved 18 September 2003
Resolution: Cleared on Board, CHK
Accommodation/Occupational Safety › Occupational Safety
Issued 4 August 2003
Resolved
Stairway (steps) wasted leading to engineering space wasted and unsafe. Make permanent and proper repairs to the satisfaction of the attending USCG. Marine Inspector.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 September 2003
Resolution: Cleared on Board, CHK
Accommodation/Occupational Safety › Occupational Safety
Issued 4 August 2003
Resolved
Decking on 01 deck in way of stairway wasted, and unsafe. Make permanent and proper repairs to the satisfaction of the attending USCG. Marine
Action required: 15 - Rectify deficiencies by next port
Resolved 18 September 2003
Resolution: Cleared on Board, CHK
Personnel › Manning/Qualifications
Issued 1 July 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2003
Engineering › Generator (propulsion-electric)
Issued 1 July 2003
Resolved
Repair fuel leak on main generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 1 July 2003
Resolved
Provide cover to main switch board, covers on vessel but not in use.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 1 July 2003
Resolved
Repair two light fixtures: (i) behind main switchboard & (ii) in eng. room tool shop. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Due 1 August 2003
Resolved 14 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 1 July 2003
Resolved
Provide non-conductive material to deck behind main switchboard.
Due 1 August 2003
Resolved 14 July 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 1 July 2003
Resolved
Properly stow CO2 bottle in eng. room tool shop. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Unknown
Due 1 August 2003
Resolved 14 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 1 July 2003
Resolved
Properly terminate exposed electric cables IWO emergency steering.
Due 1 August 2003
Resolved 14 July 2003
Engineering › Sea-water System (primary cooling)
Issued 1 July 2003
Resolved
Repair two soft patches: (i) Seawater suction pipe for main engine and (ii) in ballast pipe IWO manifolds. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2003
Engineering
Issued 1 July 2003
Resolved
Provide adequate connection from ballast pump to manifold, current rubber hose is tied using improvised rubber knot. LEGACY COMPONENT DESC: Ballast piping
Due 1 August 2003
Resolved 14 July 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 1 July 2003
Resolved
Provide two cover for rotating machinery: (i) main fire pump and (ii) ballast pumps. LEGACY COMPONENT DESC: Covers to rotating machinery
Due 1 August 2003
Resolved 14 July 2003
Fire Fighting › Fire Pumps
Issued 1 July 2003
Resolved
Provide adequate handle for valve on fire main pipe; handle is half broken. LEGACY COMPONENT DESC: Valve on pipe
Due 1 August 2003
Resolved 14 July 2003
Personnel › Certificates/Documents/Licenses
Issued 1 July 2003
Resolved
Provide valid medical certificates for all crew members.
Due 1 August 2003
Resolved 14 July 2003
Fire Fighting › Emergency Fire Pumps
Issued 1 July 2003
Resolved
1. Ensure adequate pressure from aux. fire pump 2. Fix water leak on hydrants and hose connections. LEGACY COMPONENT DESC: Pressure
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2003
Operations/Management › Drills/Instruction
Issued 1 July 2003
Resolved
Complete fire/abandon ship drills. Must have cleared following issues prior to drills: manning & aux. fire main pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2003
Fire Fighting
Issued 1 July 2003
Resolved
Repair smoke detector in Eng. Room tool shop. LEGACY COMPONENT DESC: Smoke detector
Due 1 August 2003
Resolved 14 July 2003
Deck/Cargo › Ballast
Issued 31 January 2003
Resolved
Vessel is required to return to dock in the Port of Miami, due to stability concerns. Vessel is unable to deballast #11C ballast tank and has insufficient stability in present condition. LEGACY COMPONENT DESC: Dedicated Clean Ballast Tanks
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2003
Deck/Cargo › Ballast
Issued 31 January 2003
Resolved
Upon deballasting #11C tank, make tank available for class/flag exam for possible free communication with #6 STBD ballast tank. LEGACY COMPONENT DESC: Dedicated Clean Ballast Tanks
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2003
Deck/Cargo › Ballast
Issued 31 January 2003
Resolved
Class/Flag to address inability of the ballast pump to obtain suction from the #11C ballast tank. LEGACY COMPONENT DESC: Pumps
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2003
Documentation › Certificates/Documents
Issued 31 January 2003
Resolved
Provide Flag State endorsement for an updated Vessel Stability Book and Graph reflecting the current conditions of the vessel prior to loading at the next U.S. Port. LEGACY COMPONENT DESC: Intact Stability Booklet
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2003
Resolution: Naval architect Fabio Fjardo, revised stability data and Neotech, flag rep approved.
Lifesaving
Issued 27 January 2003
Resolved
Mount light fixtures in way of embarkation area for STBD lifeboat.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 April 2003
Stability
Issued 27 January 2003
Resolved
Have flag state address all watertight integrity issues (i.e. hatch covers, cargo hatch covers, wasted gaskets, etc...) and provide proposal for repairs to MSO Miami.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Engineering › Generator (propulsion-electric)
Issued 27 November 2002
Resolved
Remove putty/redhand and marlin from cooling water intake line #1 generator and make proper repair to same.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: Properly repaired.
Construction/Loadline › Structures
Issued 27 November 2002
Resolved
Make weathertight stbd bulkhead in way of stbd lifeboat area approx 1" from deck is wasted.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: Properly repaired.
Construction/Loadline › Structures
Issued 27 November 2002
Resolved
Repair/replace stbd ladder rungs leading from bridge to lifeboat deck.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: Repaired.
Electrical › Electric Supply System (service)
Issued 27 November 2002
Resolved
Properly run wiring to light fixtures on mooring deck aft leading from engine room vent to lighting fixtures and junction box.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: Properly wired.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 27 November 2002
Resolved
Make hatch on port side bulkhead of A/C room weathertight.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: Properly repaired.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 27 November 2002
Resolved
Secure A/C panel and provide light fixture cover on light in same space.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: Properly repaired.
Lifesaving › Buoyant Smoke Signals
Issued 27 November 2002
Resolved
Replace line on both port and stbd light/smoke appliances. Current line is rotten.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: Line replaced.
Construction/Loadline › Structures
Issued 27 November 2002
Resolved
Replace/repair port ladder leading to navigation lights on deck above pilot house.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: Ladder replaced.
Lifesaving › Lifeboat
Issued 27 November 2002
Resolved
Replace retro tape on port and stbd lifeboat.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: Tape replaced.
Lifesaving › Lifeboat
Issued 27 November 2002
Resolved
Replace grab line on stbd side lifeboat.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: Grabline replaced.
Lifesaving › Lifeboat
Issued 27 November 2002
Resolved
Mount light fixture in way of embarkation area for stbd lifeboat.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Construction/Loadline
Issued 27 November 2002
Resolved
Service ALL roller chalks on both fwd and aft mooring deck.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: All roller chalks serviced.
Construction/Loadline
Issued 27 November 2002
Resolved
Provide gasket and bolts for both port and stbd access covers to chain locker.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: Equipment provided.
Engineering
Issued 27 November 2002
Resolved
Remove flammables and oiled boxes from engine room.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2003
Resolution: Flammables removed.
Construction/Loadline › Markings
Issued 24 July 2002
Resolved
Show loadline markings and mark of assigning authorities IAW international conference of Laodline, 1966 and loadline certificate. LEGACY COMPONENT DESC: Load Line Mark
Action required: 705 - Other - as specified
Due 27 January 2003
Resolved 27 January 2003
Personnel › Certificates/Documents/Licenses
Issued 24 July 2002
Resolved
Show proof that all crew members onboard have applied for ST.Vincent endorcements to STCW 95 certificates and A.B's and oil hold STCW 95 Certificates. LEGACY COMPONENT DESC: STCW Endorsement
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2002
Resolved 24 July 2002
Lifesaving › Buoyant Smoke Signals
Issued 24 July 2002
Resolved
Replace both Ikaros model MKII man-overboard smoke signal made by Hansson Pyrotech AB due to safety issues associated with device.
Action required: 705 - Other - as specified
Due 24 October 2002
Resolved 27 January 2003
Resolution: Not required to do this any longer.
Fire Fighting › Miscellaneous Items
Issued 24 July 2002
Resolved
Remove rubbish from on top of fire dampers/hatch covers leading into engine room at centerline under boat deck. LEGACY COMPONENT DESC: Fire Dampers
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2002
Resolved 6 February 2024
Resolution: All items removed from top of fire dampers leading into engine room.
Lifesaving › Lifeboat
Issued 24 July 2002
Resolved
Remove pipes and hoses from ladders (fwd of pilot house) leading to lifeboats. LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2002
Resolved 6 February 2024
Resolution: Pipes and hoses removed from ladders. (fwd of pilot house)
Fire Fighting › Fire Hoses
Issued 24 July 2002
Resolved
Remove rope securing starboard fire box (stbd on super structure) and provide proper closure for securing. LEGACY COMPONENT DESC: Box
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2002
Resolved 8 August 2002
Resolution: Rope has been removed securing starboard fire box.
Fire Fighting › Nozzles
Issued 24 July 2002
Resolved
Provide nozzle in port fire box amidships. LEGACY COMPONENT DESC: Location
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2002
Resolved 8 August 2002
Resolution: Nozzls provided in port fire box amidships.
Documentation › Safety/Response Plans/Programs
Issued 24 July 2002
Resolved
Update fire control plan to show where all fire equipment is stored (i.e. international shore connection, fire ax etc...). Noted equipment on plan not in correct place. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 24 August 2002
Resolved 27 January 2003
Resolution: Fire plan matches equipment.
Stability › Watertight Integrity
Issued 24 July 2002
Resolved
Have flag state address all watertight integrity issues (i.e. hatch covers, cargo hatch covers, wasted gaskets etc...) and provide proposal for repairs to MSO Miami.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2002
Resolved 27 January 2003
Documentation › Logs/Records
Issued 24 July 2002
Resolved
Provide MSO Miami copies of surveys conducted for 2000 dry dock period and March 2002 Annual survey. LEGACY COMPONENT DESC: Dry dock and annual surveys
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2002
Resolved 8 August 2002
Resolution: survey provided dry dock March 2002 Annual survey.
Documentation › Logs/Records
Issued 24 July 2002
Resolved
Have Flag State provide report to USCG MSO Miami attesting that vessel meets all requirements in CCSSC (Lifesaving, fire fighting, machinary etc..). LEGACY COMPONENT DESC: Surveyors report
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2002
Resolved 27 January 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 13 May 2002
Resolved
Have vessel fumigated to rid of insects.
Due 13 June 2002
Resolved 24 July 2002
Operations/Management › Navigation Safety
Issued 13 May 2002
Resolved
Make corrections to U.S. Coast Pilot [name withheld] and Coast Guard Light List. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 13 June 2002
Resolved 24 July 2002
Lifesaving
Issued 13 May 2002
Resolved
Prove proper operation of daylight signalling lamp.
Due 13 June 2002
Resolved 24 July 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 13 May 2002
Resolved
Provide proof of inspection of fixed CO2 System- las inspection APR00.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2002
Resolution: def cleared
Fire Fighting › Fire Main
Issued 13 May 2002
Resolved
Fix leaks to fire main pump, priming pump (generator) and ballast water pump in engine room.
Due 13 June 2002
Resolved 27 January 2003
Resolution: Leaks fixed.
Operations/Management
Issued 13 May 2002
Resolved
Provide Ballast Water management plan.
Due 13 June 2002
Resolved 24 July 2002
Fire Fighting › Emergency Fire Pumps
Issued 13 May 2002
Resolved
Prove proper operation of emergency fire pump in presence of USCG Inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2002
Personnel › Manning/Qualifications
Issued 13 May 2002
Resolved
Man vessel IAW Minimum Safe Manning document. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2002
Operations/Management › Drills/Instruction
Issued 13 May 2002
Resolved
Perform Fire and Abandon ship drills in presence of USCG Inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2002
Resolution: def corrected
Deck/Cargo
Issued 20 September 2001
Resolved
Have Flag provide tonnage measurements and a letter stating that they except 296.53 as the vessel's tonnage vise 1747, prior to loading/departure.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Lifesaving
Issued 20 September 2001
Resolved
Replace light on main deck, portside lifebuoy.
Condition: Unknown
Due 21 September 2001
Resolved 20 September 2001
Documentation
Issued 20 September 2001
Resolved
Provide International Sewage Prevention Certificate on board.
Condition: Unknown
Due 28 September 2001
Resolved 25 October 2001
Fire Fighting
Issued 20 September 2001
Resolved
Provide proper ventilation for CO2 room.
Condition: Unknown
Due 26 October 2001
Resolved 26 October 2001
Lifesaving
Issued 20 September 2001
Resolved
Conduct abandon ship drill in presence of USCG Marine Inspectors
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Fire Fighting
Issued 20 September 2001
Resolved
Provide flange and bolts for International Shore Connection.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Fire Fighting
Issued 20 September 2001
Resolved
Make repairs to emergency fire pump. Provide Class surveyor's report attesting to proper operation.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Lifesaving
Issued 20 September 2001
Resolved
Submit to USCG annual freight vessel exam, prior to loading/departure.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Lifesaving
Issued 20 September 2001
Resolved
Have surveyor provide report attesting that vessel is ready for US Coast Guard inspection, prior to loading/departing.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Deck/Cargo
Issued 20 September 2001
Resolved
Provide all original certificates onboard vessel for US Coast Guard inspection, prior to loading/departure.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Documentation
Issued 20 September 2001
Resolved
Commence logging in Bridge Log. Last entry made 09SEP01.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Documentation
Issued 20 September 2001
Resolved
Provide line diagram for lube/fuel oil transferred in oil transfer procedures.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Accommodation/Occupational Safety
Issued 20 September 2001
Resolved
Provide lighting in crew berthing adjacent to galley.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Electrical
Issued 20 September 2001
Resolved
Remove all bare wires in bridge.
Condition: Unknown
Due 21 September 2001
Resolved 20 September 2001
Electrical
Issued 20 September 2001
Resolved
Repair exhaust leak on generator #1.
Condition: Unknown
Due 28 September 2001
Resolved 20 September 2001
Electrical
Issued 20 September 2001
Resolved
Repair fuel oil leak on mainsupply line (from tank to manifold) on generators #2 and #3.
Condition: Unknown
Due 28 September 2001
Resolved 20 September 2001
Deck/Cargo
Issued 20 September 2001
Resolved
provide Oiler's medical certificate, prior to returning to US.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Accommodation/Occupational Safety
Issued 3 October 1996
Resolved
GALLEY SINK DRAIN PIPE BROKEN ON OVERHEAD OVER AFT CENTER MAIN DECK. ALL DRAINAGE FROM GALLEY SINKS EMPTYING ON MAIN DECK CREATING SLIPPING HAZARD.
Condition: Unknown
Due 25 October 1996
Resolved 9 December 1996
Construction/Loadline
Issued 3 October 1996
Resolved
STEPS ON LADDER AFT OF PILOT HOUSE WASTED, NEED REPAIR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 October 1996
Resolved 9 December 1996
Lifesaving
Issued 28 June 1996
Resolved
LAST ANNUAL DID NOT REQUIRE CREW PERFORMANCE OF FIRE DRILL.
Condition: Unknown
Due 1 July 1996
Resolved 8 August 1996
Documentation
Issued 28 June 1996
Resolved
PROVIDE MEDICAL CERTIFICATES FOR MENDOZA AND GENIUS
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Documentation
Issued 26 May 1996
Resolved
PROVIDE MEDICAL CERTIFICATES FOR ALL CREW MEMBERS (MENDOZA, ANTHONY, & GENIUS)
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Electrical
Issued 26 May 1996
Resolved
PROVIDE PERMANENT EMERGENCY LIGHTING OVER LIFEBOAT AND LIFERAFT LAUNCHING STATIONS.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Lifesaving
Issued 26 May 1996
Resolved
PROVIDE TRAINING MANUAL FOR LIFESAVING APPLIANCES AS REQUIRED BY SOLAS 74, CHAPTER III, REGULATION 51
Condition: Unknown
Due 27 May 1996
Resolved 3 June 1996
Lifesaving
Issued 26 May 1996
Resolved
INCLUDE INSTRUCTIONS FOR ALL TEN (10) CREW MEMBERS ON THE MUSTER LIST AS REQUIRED BY SOLAS 74, CHAPTER III, REGULATION 53
Condition: Unknown
Due 27 May 1996
Resolved 3 June 1996
Lifesaving
Issued 26 May 1996
Resolved
PROVIDE SERVICING INFORMATION ON SECOND LIFERAFT
Condition: Unknown
Due 27 May 1996
Resolved 3 June 1996
Lifesaving
Issued 26 May 1996
Resolved
PROVIDE ALL LIFEJACKETS WITH THE REQUIRED WHISTLES, WATER LIGHTS, REFLECTIVE MATERIAL AND SHIP'S NAME AS REQUIRED BY SOLAS 74, CHAPTER III, REGULATION 27.2.2
Condition: Unknown
Due 27 May 1996
Resolved 27 May 1996
Fire Fighting
Issued 26 May 1996
Resolved
REPAIR OR REPLACE TWO BROKEN FIRE HOSES
Condition: Unknown
Due 27 May 1996
Resolved 27 May 1996
Accommodation/Occupational Safety
Issued 11 May 1995
Resolved
REPAIR/REPLACE ALL WASTED WEATHERDECK STAIRS IAW ILO-147.
Condition: Unknown
Due 11 June 1995
Resolved 29 May 1995
Accommodation/Occupational Safety
Issued 11 May 1995
Resolved
PROVE PROPER OPERATION OF TYPE II MARINE SANITATION DEVICE TO USCG INSPECTOR.
Condition: Unknown
Due 11 May 1995
Resolved 29 May 1995
Navigation
Issued 11 May 1995
Resolved
PROVIDE PROPER NAVLIGHTS IAW COLREGS 72
Condition: Unknown
Due 11 May 1995
Resolved 29 May 1995
Documentation
Issued 11 May 1995
Resolved
PROVIDE COPY OF SAFE MANNING CERTIFICATE WITHOUT 600 MILE RESTRICTION FROM FLAG STATE REP
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Engineering
Issued 11 May 1995
Resolved
COMPLETE INSTALLATION OF OILYWATER SEPARATOR AND PROVIDE CLASS CERTIFICATION OF PROPER INSTALLATION
Condition: Unknown
Due 11 May 1995
Resolved 29 May 1995
Navigation
Issued 11 May 1995
Resolved
PROVIDE MANEUVERING FACT SHEET ON BRIDGE IAW 33CFR 164.35(g)
Condition: Unknown
Due 11 June 1995
Resolved 19 June 1995
Electrical
Issued 11 May 1995
Resolved
PROVIDE PROPER LIGHT COVERS FOR ALL LIGHTS IN ENGINE ROOM
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Documentation
Issued 11 May 1995
Resolved
PROVI9DE VALID IOPP CERTIFICATE FROM CLASS
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Accommodation/Occupational Safety
Issued 11 May 1995
Resolved
INSTALL OVERBOARD STOP VALVE TO MARINE SANITATION DEVICE. SYSTEM SHALL NOTBE USED AND INTAKE VALVE TO SEWAGE TANK SHALL BE CLOSED UNTIL REQUIREMENTS ARE ME.
Condition: Unknown
Due 11 May 1995
Resolved 29 May 1995
Deck/Cargo
Issued 11 May 1995
Resolved
PROVIDE CONTAINMENT FOR LEAKING HYDRAULIC EQUIPMENT FORWARDOR REPAIR ALL LEAKS.
Condition: Unknown
Due 11 June 1995
Resolved 19 June 1995
Navigation
Issued 11 May 1995
Resolved
PROVIDE BLOCK DIAGRAM/OPERATING INSTRUCTIONS FOR STEERING GEAR CHANGE OVER ON THE BRIDGE.
Condition: Unknown
Due 11 June 1995
Resolved 29 May 1995
Documentation
Issued 11 May 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Navigation
Issued 11 May 1995
Resolved
SUBMIT LETTER OF DEVIATION TO DEPART WITH AN INOPERABLE GYROCOMPASS.
Condition: Unknown
Due 11 May 1995
Resolved 29 May 1995
Navigation
Issued 11 May 1995
Resolved
PROVIDE CURRENT; US COAST PILOT, COAST GUARD LIGHT LIST, TIDAL CURRENT TABLES.
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Navigation
Issued 11 May 1995
Resolved
PROVIDE UPDATED CHARTS TO BE CURRENT WITH LOCAL NOTICE TO MARINERS.
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Lifesaving
Issued 11 May 1995
Resolved
PROVIDE EVIDENCE THAT LIFERAFT HYDROSTATIC RELEASE HAS BEEN SERVICED AND TESTED.
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Deck/Cargo
Issued 11 May 1995
Resolved
PROVIDE FAX COPY OF SAT REPORT OF CARGO GEAQR SURVEY FROM CLASS (ANNUAL SURVEY)
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Documentation
Issued 10 October 1987
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 May 1995
Resolved 29 May 1995