Records from 1993 to 2008. Most recent: operational control imposed, 10 September 2008.
Inspection history · 111
3 September 2008
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3317012
18 August 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3302249
16 August 2008
ILO-147 Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3299975
16 August 2008
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3300109
30 July 2008
MARPOL Annex I Examination · ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3283276
9 July 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3263047
30 June 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3253009
30 June 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3253421
13 February 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3147960
4 February 2008
COC-CVE Annual · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3141386
20 November 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3099866
12 November 2007
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3094807
1 July 2007
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2979298
5 June 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2953218
9 May 2007
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2925277
12 February 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam · COC-CVE Annual · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2870658
11 October 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2798289
10 October 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2816832
28 August 2006
MARPOL Annex I Examination · ISPS III Exam · Deficiency Check · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2765918
2 August 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2733965
23 May 2006
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2656958
14 March 2006
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2607954
27 February 2006
STCW 95 Exam · Ballast Water Examination · MARPOL Annex I Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2591778
9 December 2005
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2548590
23 November 2005
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2553663
5 August 2005
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2452637
1 August 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2447705
29 July 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2444417
19 July 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2431779
18 July 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2430722
20 June 2005
Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2398380
24 May 2005
MARPOL Annex I Examination · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2366903
7 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2305808
27 December 2004
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2264959
21 December 2004
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2262935
27 September 2004
COC-CVE Annual
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2206062
21 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2174903
28 June 2004
COC-CVE Quarterly · ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2113835
8 April 2004
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2040001
25 March 2004
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2031639
12 December 2003
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1963331
18 November 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1949803
7 November 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1956568
26 September 2003
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1913496
29 August 2003
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1890749
5 July 2003
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1835833
26 May 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1802070
16 April 2003
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1774291
14 April 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1774637
27 March 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1763709
4 October 2002
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1684577
8 April 2002
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1602091
14 January 2002
Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1478141
27 November 2001
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1075949
15 October 2001
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1458005
16 July 2001
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1401524
2 May 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 729199
23 April 2001
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1450618
12 April 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 6406
26 February 2001
Quarterly Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1455958
23 October 2000
Control Verification · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1452727
18 September 2000
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1450518
22 May 2000
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1466690
28 February 2000
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1442962
24 January 2000
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 814951
1 November 1999
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1397275
13 October 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 53527
30 August 1999
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1459536
14 June 1999
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 809433
7 June 1999
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 806389
22 February 1999
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1442790
24 November 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 807269
9 November 1998
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 803278
13 October 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 729198
28 September 1998
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 804715
23 September 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 67777
15 June 1998
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 792575
31 March 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1388494
2 March 1998
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1424538
20 January 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 412073
12 January 1998
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1110461
4 January 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 186946
13 November 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 100285
13 November 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 124102
13 November 1997
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1383694
16 September 1997
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1396796
19 August 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 783505
12 August 1997
MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1421381
21 May 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1448918
29 April 1997
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1457444
21 January 1997
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1407813
26 November 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1392564
5 November 1996
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1355993
31 October 1996
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1411370
17 October 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1398558
8 October 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 719295
4 October 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 396110
4 October 1996
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1357756
3 October 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 106404
9 August 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1363753
29 July 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1087831
21 June 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 392676
21 June 1996
Quarterly Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1078525
19 May 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 392470
19 March 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 391651
19 March 1996
Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1085482
8 February 1996
Administrative
Administrative · Marine Safety Center (MSC) · Activity 1185065
27 October 1995
Administrative
Administrative · Marine Safety Center (MSC) · Activity 1187084
21 March 1993
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1362762
18 March 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 104827
16 February 1993
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 356433
Electrical › Electric Generation Source (emergency) › Switch
Issued 16 August 2008
Resolved
The Transitional Power Unit is inoperable
Action required: 705 - Other - as specified
Due 16 August 2008
Resolved 16 August 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 August 2008
Resolved
Trash getting full and should be removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2008
Resolved 5 September 2008
Personnel › Certificates/Documents/Licenses › License, First Assistant Engineer
Issued 4 February 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 7 February 2008
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifeboat › Carriage Requirement
Issued 12 November 2007
Resolved
Lifeboat/tender must be operationally ready according to SOLAS at all times. #9 Lifeboat is not operationally ready.
Due 12 December 2007
Resolved 19 November 2007
Resolution: Def corrected
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 November 2007
Resolved
Insects were found in galley spaces. Galley needs to be fumigated, as necessary to rid of insects.
Due 19 November 2007
Resolved 19 November 2007
Resolution: Def corrected
Construction/Loadline › Structures › End Bulkhead
Issued 12 November 2007
Resolved
Possible dead end corridors on deck 3, passage way for cabins 3081-3090. needs to be addressed by classification Society in writing to coast guard.
Due 19 November 2007
Resolved 19 November 2007
Resolution: Def corrected
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 1 July 2007
Resolved
Control Pitch Propeller is satisfactory with a load of 90%. Not operational with 100% load.
Action required: 705 - Other - as specified
Due 16 September 2007
Resolved 25 September 2007
Resolution: Class faxed in survey results. Repairs have been made and CPP is at 100%.
Electrical › Electrical Distribution System (emergency) › Switch
Issued 5 June 2007
Resolved
Emergency batteries for transitional power in operable, installed temporary generator to serve as transitional power until battery service is repaired. Replacement parts to arrive on 06/07/07.
Action required: 705 - Other - as specified
Due 7 June 2007
Resolved 13 August 2007
Resolution: Received class report of repairs.
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 11 October 2006
Resolved
One of main engines was reported inoperable, condition unknown at this time.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 November 2006
Resolved 9 May 2007
Resolution: Engines repairs were made and class survey was given attesting to repairs
Lifesaving › Launching Appliances › Davit
Issued 28 August 2006
Resolved
#10 LIFEBOAT DAVIT PULLEYS ARE SEIZED.
Action required: 705 - Other - as specified
Due 28 August 2006
Resolved 9 May 2007
Resolution: Lifeboat 10 and 9 were put out of commission and the pax count was reduced. COC and PSSC were changed and endorsed accordingly.
Engineering › Steering Gear System › Ram Seal
Issued 2 August 2006
Resolved
The pilot cylinder for the steering gear system is leaking.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2006
Resolution: Recieved a class report stating the pilot cylinder seal was replaced. The steering was tested satisfactory.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 19 December 2005
Resolved
Vessel still has not repaired the transitional power inverter. Additional portable generator on board and tested. Generator must be running while vessel is under way.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 29 December 2005
Resolution: Cleared 01 requirement "Transitional Power Test" from repair proposal plan dated 2NOV2005. See narrative act # 2558627.
Fire Fighting › Automatic Sprinkler System › Piping
Issued 19 December 2005
Resolved
Vessel not in compliance with RFSA, no sprinkler system instlalled. Vessel recieved two extensions and as on 23 NOV 05 can not carry passengers until system is completed and tested to satisfaction of Class and USCG.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2005
Resolved 19 December 2005
Resolution: System completed and tested by class and USCG
Construction/Loadline › Hull › Hull Plating
Issued 9 December 2005
Resolved
large inset on port side below l/b# 4. Have class attest to the structural integrity of the plate.
Action required: 705 - Other - as specified
Due 30 December 2005
Resolved 12 December 2005
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 29 July 2005
Resolved
Transitional source of power is inoperable. provide class report to attest to repairs and proper operation of transitional power.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 July 2005
Resolved 23 November 2005
Resolution: Re-issued see activity 2553663
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 18 July 2005
Resolved
Notice of Arrival, General - Unknown Cause/Condition (33CFR160.212(a)(3)(ii))
Action required: 705 - Other - as specified
Due 18 July 2005
Resolved 18 July 2005
Fire Fighting › Structural - Main Vertical Zones › General
Issued 21 December 2004
Resolved
Rolling fire screen door is inoperable in gally
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2004
Resolved 27 December 2004
Fire Fighting › Structural - Main Vertical Zones › General
Issued 21 December 2004
Resolved
Fire screen door 1137 not closing properly and is wasted at the bottom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2004
Resolved 27 December 2004
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 21 December 2004
Resolved
Door jam for fire screen door in way of the galley is not sealed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 December 2004
Resolved 27 December 2004
Lifesaving › Lifeboat › Propulsion Engine
Issued 21 December 2004
Resolved
Lifeboat number 7 will not operate forward or astern.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 December 2004
Resolved 21 December 2004
Resolution: Renewed fuel filter and conducted operational test of lifeboat. all sat.
Documentation › Certificates/Documents › Passenger Ship Safety Certificate
Issued 21 December 2004
Resolved
Vessels maximum number of passengers is reduced by 180 untill proper repairs are made to lifeboat #7 are completed
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 December 2004
Resolved 21 December 2004
Electrical › Electric Generation Source (emergency) › Generator
Issued 27 September 2004
Resolved
1430. Secondary means of starting generator make proper repairs and have flag state attest to proper operation. Provide report to Sector Miami. 50.
Due 27 October 2004
Resolved 28 October 2004
Resolution: Second set of batteries were installed.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 1 April 2004
Resolved
Provide Flag State report addressing satisfactory repairs to the tiller of lifeboat number 2. Vessel shall reduce passenger capacity from 900 to 792 until Flag State approves repairs to lifeboat number 2.
Due 31 May 2004
Resolved 27 September 2004
Operations/Management › Vessel Safety Management
Issued 25 March 2004
Resolved
CONDUCT SMS EXTERNAL AUDIT BY DIRECT REPRESENTATIVE OF FLAG STATE ADMINSTRATION REGARDING MAINTENANCE RECORDS FOR STRUCTURAL AND ACTIVE FIRE PROTECTION AND FAMILIARIZATION WITH EMERGENCY PROCEDURES BY CREW. FOR EXAMPLE, MAINTENANCE LOGS FOR SPRINKLER SYSTEM DOES NOT MATCH ENGINE ROOM OR BRIDGE LOGS LEGACY COMPONENT DESC: External Certification/Verification/Control
Due 12 April 2004
Resolved 8 April 2004
Operations/Management › Drills/Instruction
Issued 25 March 2004
Resolved
CONDUCT ABANDON SHIP DRILL (INCLUDING LOWERING OF LIFEBOATS) TO THE SATISFACTION OF ATTENDING USCG INSPECTOR. LEGACY COMPONENT DESC: Abandon Ship
Due 1 April 2004
Resolved 1 April 2004
Fire Fighting › Structural Fire Protection - General
Issued 25 March 2004
Resolved
PROPERLY REPAIR FSD 230C AND 1130 C.
Due 1 April 2004
Resolved 8 April 2004
Fire Fighting › Fixed Fire Detection System
Issued 25 March 2004
Resolved
PROVIDE REPORT FROM TECHNICIAN ADDRESSING SATISFACTORY OPERATION OF ALL SMOKE DETECTORS AND MANUAL CALL POINTS. SOME SMOKE DETECTORS, WHEN ACTIVATED, WERE NOT IDENTIFIED CORRECTLY BY THE AUTRONICA FIRE DETECTION SYSTEM. TECHNICIAN MUST ALSO LIST ALL THE SMOKE DETECTORS THAT WERE REPAIRED TO ENSURE LEGACY COMPONENT DESC: Detector/Call Point Grouping
Due 1 April 2004
Resolved 8 April 2004
Electrical › Electrical Distribution System (service)
Issued 25 March 2004
Resolved
PROPERLY REMOVE OR COVER EXPOSED WIRES IN THE FOLLOWING ITEMS: IWO FIRE HYDRANT LOCKER 123, DRESSIN ROOMS, COMPART MENT 438C (AC CONDENSER ROOM).
Due 1 April 2004
Resolved 8 April 2004
Fire Fighting › Means of Escape
Issued 25 March 2004
Resolved
ENSURE NO COMBUSTIBLES ARE STOWED UNDERNEATH STAIRWAYS. LEGACY COMPONENT DESC: Enclosed Stairway
Due 1 April 2004
Resolved 8 April 2004
Fire Fighting › Grease Extraction Hood
Issued 25 March 2004
Resolved
PROVIDE GREASE TRAP ON MAIN GALLEY. LEGACY COMPONENT DESC: Grease Traps
Due 1 April 2004
Resolved 8 April 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 25 March 2004
Resolved
PROPERLY SECURE CO2 BOTTLES IN DISCO BAR. LEGACY COMPONENT DESC: Tanks
Due 1 April 2004
Resolved 8 April 2004
Electrical › Electrical Distribution System (service)
Issued 25 March 2004
Resolved
PROVIDE COVERS TO THE FOLLOWING ELECTRICAL PANELS: COMAPRTMENT (452C) AND E.L. LOCKER (597 C). LEGACY COMPONENT DESC: Covers
Due 1 April 2004
Resolved 8 April 2004
Electrical › Lighting (emergency)
Issued 26 September 2003
Resolved
Emergency Lighting Batteries not proper wired, dead end wires and boxes rotted. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Construction/Loadline › Structures
Issued 26 September 2003
Resolved
Bulkhead wasted to battery room. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Electrical › Electrical Distribution System (service)
Issued 26 September 2003
Resolved
Electrical hazard in passenger open stairway. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Cable
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Electrical › Electrical Distribution System (service)
Issued 26 September 2003
Resolved
Fan room fwd on 2nd deck has improper stowage of spare parts on wooden shelves and dead end wiring. This fan room opens into two stairways. Ensure there is no storage and the all electrical hazards are properly repaired to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Fire Fighting › Structural Fire Protection - General
Issued 26 September 2003
Resolved
Locker in stairway has fire dampers inside. Provide sign to keep locker clear, NO STOWAGE, and repair lighting in locker. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Fire Fighting › Structural Fire Protection - General
Issued 26 September 2003
Resolved
Carpet running under fire screen door; survey all doors and ensure mental threshold is properly installed. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Electrical › Electrical Distribution System (service)
Issued 26 September 2003
Resolved
Wiring to bandstand improper and a fire hazard, remove all house hold surge protectors and provide properly wire outlets for the equipment. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Fire Fighting › Structural Fire Protection - General
Issued 26 September 2003
Resolved
Local release switch not operating properly to fire screen door number 539C. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Fire Fighting › Structural Fire Protection - General
Issued 26 September 2003
Resolved
Vessel to demonstrate general closing of fire screen and water tight doors from the bridge at next inspection to the satisfaction of the attending Marine Inspector
Due 28 December 2003
Resolved 15 December 2003
Resolution: Cleared on board 10/20/03, CHK.
Electrical › Electrical Distribution System (service)
Issued 26 September 2003
Resolved
Photo Lab in complete disarray, with electrical hazard and combustible material laying about. Photo Lab not properly reflected on the fire control plan. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Fire Fighting › Means of Escape
Issued 26 September 2003
Resolved
Signage throughout the vessel is excessive, out of date, and not correct, possibly causing confusion for passengers. Ensure all signage complies with IMO requirements properly indicating exit, emergency exits, and lifeboat/raft muster stations. (Red lifeboat sign not acceptable as exit sign.) Make
Due 28 December 2003
Resolved 15 December 2003
Fire Fighting › Means of Escape
Issued 26 September 2003
Resolved
"YOU ARE HERE" signs not up to date. Up date signs and place on each stairway landing, to the satisfaction of the attending Marine Inspector.
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Documentation › Safety/Response Plans/Programs
Issued 26 September 2003
Resolved
Ventilation Closures not on fire control plan throughout the vessel. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Fire Control Plans
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 26 September 2003
Resolved
Fire station numbering does not match Fire Control Plan. Survey all Fire Stations ensure they are properly reflected on the fire control to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Fire Control Plans
Due 28 December 2003
Resolved 27 September 2004
Documentation › Safety/Response Plans/Programs
Issued 26 September 2003
Resolved
Hospital Isolations rooms are being utilized as Massage Rooms. Return spaces to original, and have fire control plan properly reflect the spaces as is, including proper escape routes, to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Fire Control Plans
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Documentation › Safety/Response Plans/Programs
Issued 26 September 2003
Resolved
Several cabins have been changed to offices and are not properly indicated on the fire control plan, nor have they been approved by class, return all such spaces to original or have them approved by class and added to the fire control plan, to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Fire Control Plans
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Documentation › Safety/Response Plans/Programs
Issued 26 September 2003
Resolved
Stowage space added next to pump room, space appears to be added and not on fire control plan. Return to original or have them approved by class and added to the fire control plan, to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Fire Control Plans
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 26 September 2003
Resolved
Fire control safety plans are not up to date and are missing several items. Provide accurate and approved plans with proper escape routes, all fire fighting equipment properly labeled and all spaces properly identified. These approved plans must be provided to this office within thirty days. LEGACY COMPONENT DESC: Fire Control Plans
Due 28 December 2003
Resolved 27 September 2004
Documentation › Safety/Response Plans/Programs
Issued 26 September 2003
Resolved
Daft stops not indicated on the fire control plans, prove proper installation of draft stops in all spaces greater than 14m with false overheads, i.e.: Crew lounge, and mess room. Have fire control plan up-dated to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Fire Control Plans
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Electrical › Lighting (emergency)
Issued 26 September 2003
Resolved
In accordance with SOLAS 74 amended (2001 Edition) Chapter: 11-2 Regulation: 42-2.4.7 and Chapter:11-1 Regulation: 42.2.1.6 ensure that all stowage spaces for firefighter's outfits have emergency lighting.
Condition: Improper Installation
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Personnel › Training
Issued 26 September 2003
Resolved
Life raft drill was not properly completed due to the removable of several improperly packed life rafts. Drill to be conducted in two weeks time.
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Fire Fighting › Miscellaneous Items
Issued 26 September 2003
Resolved
Low Location Lighting (LLL) Photo-luminescent tape throughout the vessel peeling off the bulkhead and not properly glued. In addition ambient light questionable especial in lower deck. Survey light and replace tape and lighting as needed. Make permanent and proper repairs to the satisfaction of t
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Fire Fighting › Structural Fire Protection - General
Issued 26 September 2003
Resolved
Door to laundry to ironing room, out of adjustment, (gaps in door frame), also repair the lock to allow escape from the space. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Fire Fighting › Structural Fire Protection - General
Issued 26 September 2003
Resolved
Bulkhead in ironing room has holes drilled in it (A-0 boundary) Make permanent and proper repairs to the satisfaction of the attending Marine Inspector and survey all boundaries in the area for the same. LEGACY COMPONENT DESC: Structural Bulkhead Construction
Due 20 October 2003
Resolved 20 October 2003
Resolution: Cleared on board 10/20/03, CHK.
Fire Fighting › Combustible Materials
Issued 29 August 2003
Resolved
Crew Identification badges in wood box mounted in stairway. Introducing wood into the vessel is not allowed by SOLAS and the box cannot be mounted in the stairway. Provide proper box and mount outside of stairway to the satisfaction of Class LEGACY COMPONENT DESC: Furniture/Furnishings
Condition: Improper Installation
Due 22 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Lifesaving › Lifeboat
Issued 29 August 2003
Resolved
Improper Repairs to gunwale of life boats, have repairs approved by manufacture or certified repair facility. LEGACY COMPONENT DESC: Hull
Due 22 September 2003
Resolved 29 September 2003
Resolution: Cleared on board, CHK
Lifesaving › Lifeboat
Issued 29 August 2003
Resolved
Keel of lifeboats have putty along center line (possible improper repairs). Investigate the use of putty and if repairs, have repairs approved by manufacture or certified repairs facility. LEGACY COMPONENT DESC: Hull
Due 22 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Lifesaving › Lifeboat
Issued 29 August 2003
Resolved
Grab rails on bottom of life boats replaced with line, replace as original or as per SOLAS to satisfaction of Class
Due 22 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Lifesaving › Lifeboat
Issued 29 August 2003
Resolved
Rudder mounting brackets wasted and missing, Make permanent and proper repairs to the stratification of Class. LEGACY COMPONENT DESC: Rudder/Tiller/Steering
Due 22 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Construction/Loadline › Structures
Issued 29 August 2003
Resolved
Decking on embarkation deck is rotting and numerous repairs have been made. Due to the amount of moister in the old wood decking the condition of the steel under deck is in question. Prove proper condition of steel to Class as well as the existing repairs. Any repairs most meet new SOLAS and be no LEGACY COMPONENT DESC: Deck Plating
Due 22 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Construction/Loadline › Structures
Issued 29 August 2003
Resolved
Deck above embarkation deck appears to be cracking and sagging. Make permanent and proper repairs to the stratification of Class and have class attest to the over all condition of bulkhead. LEGACY COMPONENT DESC: Deck Plating
Due 22 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Lifesaving › Launching Appliances
Issued 29 August 2003
Resolved
Hand crank guide wasted and may impede operation. Make permanent and proper repairs to the satisfaction of Class. LEGACY COMPONENT DESC: Hand Gear
Due 22 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Stability › Watertight Integrity
Issued 29 August 2003
Resolved
Water tight door to fan room on embarkation deck, wasted and repaired with putty. Replace door or make permanent and proper repairs to the satisfaction of Class.
Due 28 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Construction/Loadline › Structures
Issued 29 August 2003
Resolved
Port side bulk head just fwd of Embarkation wasted and holed. Make permanent and proper repairs to the stratification of Class and have class attest to the over all condition of bulkhead. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Electrical › Electrical Distribution System (service)
Issued 29 August 2003
Resolved
Wiring on embarkation deck improper. Ensure all cable runs are protected from chaffing, remove old wasted conduit. Ensure all watertight fixtures are water tight without an excess of putty or plastic. Make permanent and proper repairs to the satisfaction of Class.
Due 22 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Fire Fighting › Combustible Materials
Issued 29 August 2003
Resolved
Wood steps have been added to almost of doorways on upper deck, wood may not be introduced to vessel, especially in stairways. Replace the wood with approved material and make permanent and proper repairs to the stratification of Class
Condition: Improper Installation
Due 22 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Lifesaving › Lifeboat
Issued 29 August 2003
Resolved
Lifeboat/tenders 9&10 have been removed for repairs, the passenger count reduced and new Certificate of Compliance (COC) issued. Once lifeboat/tenders are returned to the vessel and before passenger count is increased, make vessel available for annual inspection to renew the COC.
Due 22 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Documentation › Safety/Response Plans/Programs
Issued 29 August 2003
Resolved
At least one week prior to annual inspection for the renewal of the COC, Scheduled 22 September, 2003) provide this office with an up to date working copy of the Fire Control Plans, Safety Plan and Structural Fire Protection plans LEGACY COMPONENT DESC: Fire Control Plans
Due 15 September 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Fire Fighting › Structural - A Class Divisions
Issued 16 April 2003
Resolved
Remove holdback on FSD 552C to the Bakery. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 30 April 2003
Resolved 23 September 2003
Resolution: Cleared on board, CHK
Fire Fighting › Means of Escape
Issued 16 April 2003
Resolved
Provide reflective arrows for escape routes from engine room. LEGACY COMPONENT DESC: Escape Route Signs
Due 30 April 2003
Resolved 28 September 2003
Resolution: Cleared on board, CHK
Lifesaving › Lifebuoys
Issued 4 October 2002
Resolved
Replace smoke/light signals on lifebuoys on bridge wings. LEGACY COMPONENT DESC: Self-Activitating Smoke Signals
Due 7 January 2003
Resolved 10 March 2003
Engineering › Generator (propulsion-electric)
Issued 4 October 2002
Resolved
Provide report of repair to #3 generator fuel oil line pinhole leak leading to secondary filter.
Due 14 October 2002
Resolved 10 March 2003
Engineering › Generator (propulsion-electric)
Issued 4 October 2002
Resolved
Provide report of repair to #1 generator lube oil line leak aft end of engine room (presently using temporary clamp).
Due 14 October 2002
Resolved 10 March 2003
Lifesaving › Lifeboat
Issued 8 April 2002
Resolved
Replace all retro-reflective tape on all lifeboats. Retro-reflective material should be IAW IMO 658(16). LSA Code 1.2.2.7. LEGACY COMPONENT DESC: Markings
Due 15 October 2002
Resolved 10 March 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 8 April 2002
Resolved
Remove BBQ (prope grill) from under STBD life raft station.
Due 8 April 2002
Resolved 8 April 2002
Engineering › Fuel Oil Service System › Valve
Issued 14 January 2002
Resolved
a loss of a plug on a fuel oil regulating valve in the pipeline located between the fuel oil booster pump and the starboard main engine. Approx. 2.5 cu meters of fuel had leaked out to the engine room tank tops. The plug was found on the tank tops and replaced in the fuel oil regulating valve.
Due 14 January 2002
Resolved 14 January 2002
Resolution: Bureau Veritas (Class) was on board and performed a satisfactory pressure test. The fuel oil on the tank tops was pumped into the sludge tank and cleaning of the tank tops commenced.
Engineering
Issued 15 October 2001
Resolved
Repair/replace auxiliary engine cooling water piping for sea water system.
Condition: Unknown
Due 15 October 2001
Resolved 15 October 2001
Fire Fighting
Issued 15 October 2001
Resolved
Replace suction piping to #1 fire pump, IAW SOLAS II-2.
Condition: Unknown
Due 15 October 2001
Resolved 15 October 2001
Lifesaving
Issued 15 October 2001
Resolved
Repair/replace port side sewage overboard check valve. Remove cement patchfor survey.
Condition: Unknown
Due 15 October 2001
Resolved 15 October 2001
Unknown
Issued 15 October 2001
Resolved
Prove proper operation of Oily Water Separator, IAW MARPOL I.
Condition: Unknown
Due 15 October 2001
Resolved 15 October 2001
Unknown
Issued 23 April 2001
Resolved
Clean grease on air condition ducts in main galley.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Lifesaving
Issued 23 April 2001
Resolved
Remove/replace plastic/combustible waste receptacles throughout ship, or provide approval of current receptacles (expemption letter) from Flag Administration.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Fire Fighting
Issued 23 April 2001
Resolved
Provide proper IMO symboligy for all fire fighting equipment and manual call points IAW Fire Control Plan and SOLAS 74/78 II-2 Reg. 28.1.10.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Fire Fighting
Issued 23 April 2001
Resolved
Replace door on cabin # 2086 IAW Fire Control Plan and remove all combustible materials being stored.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Fire Fighting
Issued 23 April 2001
Resolved
Remove accordion-type partition made of combustible materials in Captain's cabin, or replace with non-combustible partition or B-15 boundary IAW SOLAS60, Ch II, Part D, Reg 48.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Lifesaving
Issued 23 October 2000
Resolved
Repair brake on liferaft crane.
Condition: Unknown
Due 23 October 2000
Resolved 2 November 2000
Documentation
Issued 18 September 2000
Resolved
Vessel has means to secure containers in hold. Vessel is to provide a Cargo Securing Manual or letter from Class that vessel may not carry containers.
Condition: Unknown
Due 18 September 2000
Resolved 18 September 2000
Documentation
Issued 18 September 2000
Resolved
Provide for review, for the Coast Guard, procedure for disposing of photo lab used chemicals, presently no disposal plan is used.
Condition: Unknown
Due 18 September 2000
Resolved 18 September 2000
Navigation
Issued 18 September 2000
Resolved
Provide a non-slip surface around the steering gear station.
Condition: Unknown
Due 18 September 2000
Resolved 18 September 2000
Fire Fighting
Issued 18 September 2000
Resolved
Replace all the cracked and broken glass panels on the aft exterior weatherdecks on Officers deck and boat decks.
Condition: Unknown
Due 18 September 2000
Resolved 18 September 2000
Lifesaving
Issued 22 May 2000
Resolved
Repair/replace broken (rotted) lifelines under keel on lifeboats #7 & #8.
Condition: Unknown
Due 23 May 2000
Resolved 24 May 2000
Accommodation/Occupational Safety
Issued 22 May 2000
Resolved
Finish welding pipes at Frame #22 (auxiliary e/r (pump room)) to seal openings where the pipes run through the overhead.
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Electrical
Issued 22 May 2000
Resolved
Provide/repair covers missing from overhead flourescent lights in engine room spaces.
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Accommodation/Occupational Safety
Issued 22 May 2000
Resolved
Repair damaged/rotted "elbow" in sewage pipeline in e/r near forward bulkhead.
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Accommodation/Occupational Safety
Issued 22 May 2000
Resolved
Clean laundry ducts and provide written procedures & schedule for cleaning laundry ducts.
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Documentation
Issued 22 May 2000
Resolved
Provide Class Report addressing resolution of repairs to lifelines on lifeboats #7 & #8.
Condition: Unknown
Due 23 May 2000
Resolved 24 May 2000
Lifesaving
Issued 28 February 2000
Resolved
Prior to departure provide 13 SOLAS approved children's lifejackets for a total of 120 children's lifejackets onboard (as required).
Condition: Unknown
Due 28 February 2000
Resolved 29 February 2000
Lifesaving
Issued 1 November 1999
Resolved
By 15NOV99, place waterlights on all lifejackets onboard (those stored in cabins).
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Lifesaving
Issued 1 November 1999
Resolved
By 15NOV99, update SOLAS training manual to reflect the Russian-style lifejackets.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Lifesaving
Issued 1 November 1999
Resolved
By 01DEC99, provide certification for Russian lifejackets (showing that jackets are SOLAS or IMO approved).
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Documentation
Issued 1 November 1999
Resolved
By 15NOV99, provide vessel/CG SAR plan approved by the flag state/class society.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Lifesaving
Issued 1 November 1999
Resolved
By 15NOV99, replace the expired sea-sickness pills in the lifeboats.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Lifesaving
Issued 22 February 1999
Resolved
Provide light for children's lifejackets which do not have lights. Until item is completed, vessel is not allowed to carry more than 70 children.
Condition: Unknown
Due 22 February 1999
Resolved 26 February 1999
Construction/Loadline
Issued 9 November 1998
Resolved
Prior to 09 December 1998, provide & install a reach rod & handwheel extending well above the engine room platform for the machinery space bilgesuction non-return valve in accordance with SOLAS 1960, Chapter II, Part A,Regulation 18 (iii).
Condition: Unknown
Due 9 November 1998
Resolved 9 November 1998
Lifesaving
Issued 31 March 1998
Resolved
Provide Flag approve written plan addressing passenger emergency egress in vicinity of Maranda dining room and portside passageway to veranda bar and giftshop.
Condition: Unknown
Due 31 March 1998
Resolved 1 April 1998
Lifesaving
Issued 31 March 1998
Resolved
Provide written plan addressing means of identifing special needs passengers in case of computer failure.
Condition: Unknown
Due 31 March 1998
Resolved 1 April 1998
Navigation
Issued 2 March 1998
Resolved
Prior to 15MAR98, provide proper checklist for arrival/departure testing ofsystems as required by 33 CFR 164 and SOLAS.
Condition: Unknown
Due 17 March 1998
Resolved 26 March 1998
Fire Fighting
Issued 13 November 1997
Resolved
Prior to 01 December 1997, provide documentation of satisfactory post installation tests of low level lighting. SOLAS 1974 (amended), Chapter II-2, Reg. 41-2.4.7.
Condition: Unknown
Due 13 November 1997
Resolved 13 November 1997
Fire Fighting
Issued 13 November 1997
Resolved
Prior to 03 November 1997, provide documentation from vessel's classification society addressing compliance with new installed smoke detection and alarm system to SOLAS 1974 (amended) Chapt II-2/13. SOLAS 1974 (amended), Chapt II-2/42-2.2.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Fire Fighting
Issued 13 November 1997
Resolved
Prior to 01 December 1997, provide written proposal for bringing galley range hood vents into compliance with SOLAS 74 (amended), Chapt. II-2, Reg.41-2.4.3.
Condition: Unknown
Due 13 November 1997
Resolved 13 November 1997
Electrical
Issued 13 November 1997
Resolved
Prior to 20 November 1997, prove the proper operation of the vessel's temporary "transitional" power system. SOLAS 1960, Chapt. II, Reg. 25.
Condition: Unknown
Due 13 November 1997
Resolved 17 November 1997
Documentation
Issued 12 August 1997
Resolved
DENOTE WORKING LANGUAGE OF CREW IN THE SHIPS LOG._x001C_ (ONE TIME LOG ENTRY)
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Construction/Loadline
Issued 12 August 1997
Resolved
ADJUST FIRE SCREEN DOORS; 1122C, 224C, 443C, AND AFT VIRANDA DINING ROOM ENTRANCE DOOR.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Navigation
Issued 12 August 1997
Resolved
AT NEXT DRY-DOCK OR NLT 30 JAN 98, REPAIR HYDRAULIC OIL LEAK IN WAY OF MAINSTEERING GEAR.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Documentation
Issued 12 August 1997
Resolved
PROVIDE FLAG STATE APPROVED SEARCH AND RESCUE PLAN.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Fire Fighting
Issued 5 November 1996
Resolved
MODIFY THE SALOON SPACE WHICH HAS DIRECT ACCESS TO THE ADJOINING STAIRWAY IN ACCORDANCE WITH USCG MARINE SAFETY CENTER LETTER DATED 18 OCTOBER 1996.
Condition: Unknown
Due 5 November 1996
Resolved 5 November 1996
Lifesaving
Issued 17 October 1996
Resolved
Ensure all life rafts are stowed in a float free arrangement IAW SOLAS 1974(amended), Chaotper III, Reg. 23 and 38.
Condition: Unknown
Due 17 October 1996
Resolved 17 October 1996
Fire Fighting
Issued 17 October 1996
Resolved
Ventilation system noted on fire control plan is not identified IAW SOLAS 1974 (amended), Chapter II-2, Reg. 20.
Condition: Unknown
Due 17 October 1996
Resolved 17 October 1996
Fire Fighting
Issued 17 October 1996
Resolved
Install duplicate fire control plan on weather deck IAW SOLAS 1974 (amended), Chapter II-2, Reg. 20.
Condition: Unknown
Due 17 October 1996
Resolved 17 October 1996
Lifesaving
Issued 17 October 1996
Resolved
Correct muster list to indicate officer responsibile for maintaining life- saving equipment IAW SOLAS 1974 (amended), Chapter III, Reg. 53.
Condition: Unknown
Due 17 October 1996
Resolved 17 October 1996
Lifesaving
Issued 17 October 1996
Resolved
Update training manual to show proper donning of new lifejackets on board.
Condition: Unknown
Due 17 October 1996
Resolved 17 October 1996
Lifesaving
Issued 17 October 1996
Resolved
Properly lable boxes containing lifejackets IAW SOLAS 1974 (amended), Chapter III, Reg.7.
Condition: Unknown
Due 17 October 1996
Resolved 17 October 1996
Electrical
Issued 4 October 1996
Resolved
Provide adequate emergency lighting in the movie theater to the satisfaction of the classification society. The space shall not be used until the lights are installed and approved.
Condition: Unknown
Due 5 October 1996
Resolved 8 October 1996
Engineering
Issued 4 October 1996
Resolved
Provide survey report from classification society on behalf of the [name withheld] attesting to the shaft alley heavy fuel oil tank top. Approximately 24 inches of heavy fuel oil was noted in the bilges. Scourceunknown.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Construction/Loadline
Issued 4 October 1996
Resolved
Repair or replace all watertight door alarm bells. SOLAS 60, Chapter II, Regulation 13.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Documentation
Issued 4 October 1996
Resolved
Prior to departure, make the vessel comply with the load line regulation for the C1 marking, this may require the vessel to show stability calculations for the GM change of stability in the C1 condition. SOLAS 74 (amended), Chapter II-1, Regulation 13.
Condition: Unknown
Due 4 October 1996
Resolved 7 October 1996
Fire Fighting
Issued 4 October 1996
Resolved
Prior to departure, provide all SCBA bottles and fireman's outfits that areinterchangable with required spare charges. SOLAS 74 (amended), Chapter II-2, Regulation 17.
Condition: Unknown
Due 4 October 1996
Resolved 7 October 1996
Documentation
Issued 4 October 1996
Resolved
Provide for review crew medical certificates for the entire crew within 2 years. ILO 147.
Condition: Unknown
Due 2 November 1996
Resolved 7 October 1996
Lifesaving
Issued 4 October 1996
Resolved
Prior to departure, prove proper operation of the number 4 lifeboat engine.SOLAS 74 (amended), Chapter III, Regulation 19.
Condition: Unknown
Due 4 October 1996
Resolved 7 October 1996
Lifesaving
Issued 4 October 1996
Resolved
Prior to departure, service all inflatable life rafts except the 9 new Viking rafts received on board 03OCT96. SOLAS 74 (amended), Chapter III, Regulation 19.8.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Electrical
Issued 4 October 1996
Resolved
Provide emergency lighting for the forward exits of the show lounge to the satisfaction of the classification society.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Lifesaving
Issued 4 October 1996
Resolved
Prior to departure, repair or replace the 406 MHz, Category 1 EPIRB.
Condition: Unknown
Due 4 October 1996
Resolved 7 October 1996
Electrical
Issued 4 October 1996
Resolved
Provide emergency lighting for the fire equipment lockers and the shaft alley.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Electrical
Issued 4 October 1996
Resolved
Prior to departure, prove proper operation of all emergency lights in all required locations. SOLAS 60, Regulation 25.8.
Condition: Unknown
Due 4 October 1996
Resolved 7 October 1996
Lifesaving
Issued 4 October 1996
Resolved
Provide a crew training manual in accordance with SOLAS 74 (amended), Chapter III, Regulation 51.17.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Construction/Loadline
Issued 4 October 1996
Resolved
Provide the vessel's criterion number.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Lifesaving
Issued 4 October 1996
Resolved
Prior to departure, provide the number of certified lifeboatmen assigned toeach lifeboat. SOLAS 60, Chapter III, Regulation 31.
Condition: Unknown
Due 4 October 1996
Resolved 7 October 1996
Engineering
Issued 4 October 1996
Resolved
Prior to departure, pump all machinery space bilges and dirty oil residue tank to an approved shore side facility.
Condition: Unknown
Due 4 October 1996
Resolved 7 October 1996
Fire Fighting
Issued 4 October 1996
Resolved
Prior to departure, demonstrate a satisfactory fire drill. SOLAS 74 (amended), Chapter XI, Regulation 4.
Condition: Unknown
Due 4 October 1996
Resolved 7 October 1996
Documentation
Issued 4 October 1996
Resolved
Prior to bunkering, provide oil transfer procedures for review. 33 CFR 155.720.
Condition: Unknown
Due 5 October 1996
Resolved 8 October 1996
Engineering
Issued 4 October 1996
Resolved
Prior to departure, prove proper operation of the vessel's oil water separator. MARPOL 73/78, Annex 1, Regulation 16.
Condition: Unknown
Due 4 October 1996
Resolved 7 October 1996
Lifesaving
Issued 21 June 1996
Resolved
MAKE REPAIRS TO #4 AND #6 LIFEBOAT GRAB RAILS.
Condition: Unknown
Due 29 July 1996
Resolved 29 July 1996
Electrical
Issued 21 June 1996
Resolved
REMOVE DEAD END WIRING IN VICINITY OF FIRE DOORS 216C,_x001C_ 23C, 1103C AND 1105C.
Condition: Unknown
Due 21 July 1996
Resolved 23 July 1996
Accommodation/Occupational Safety
Issued 21 June 1996
Resolved
PRIOR TO DEPARTURE REMOVE OCCUPANT FROM CLOSET LOCATED IN COMPARTMENT FD1105C AND REMOVE ALL COMBUSTABLES.
Condition: Unknown
Due 22 June 1996
Resolved 1 July 1996
Electrical
Issued 21 June 1996
Resolved
PRIOR TO DEPARTURE REMOVE BUNDLE OF WIRE THROUGH PROJECTION ROOM WINDOW ANDINSTALL FLAG APPROVED WIRING.
Condition: Unknown
Due 22 June 1996
Resolved 1 July 1996
Electrical
Issued 21 June 1996
Resolved
PRIOR TO DEPARTURE PROVIDE LIGHT COVERS FOR TWO LIGHTS LOCATED BEHIND DOOR 510C.
Condition: Unknown
Due 22 June 1996
Resolved 1 July 1996
Lifesaving
Issued 21 June 1996
Resolved
PRIOR TO DEPARTURE PERFORM AN ADEQUATE LIFEBOAT AND FIREDRILL
Condition: Unknown
Due 22 June 1996
Resolved 1 July 1996
Accommodation/Occupational Safety
Issued 21 June 1996
Resolved
PROPERLY AFFIX SIGNS THAT INDICATE CABIN NUMBERS CURRENTLY HANGING BY WIRE.(DOORS 4007-4028)
Condition: Unknown
Due 28 June 1996
Resolved 8 July 1996
Accommodation/Occupational Safety
Issued 21 June 1996
Resolved
REPLACE/REPAIR DOOR LOCK ON AFT DOOR IN POKER BAR.
Condition: Unknown
Due 28 June 1996
Resolved 8 July 1996
Lifesaving
Issued 21 June 1996
Resolved
REMOVE ALL COMBUSTIBLE MATERIAL BEHIND FORE DOORS #216C, 46C AND 37C. ALSO REMOVE CURTAIN FROM FIRE DOOR 1130C.
Condition: Unknown
Due 28 June 1996
Resolved 8 July 1996
Accommodation/Occupational Safety
Issued 21 June 1996
Resolved
PROVE PROPER OPERATION OF FIRE DOORS 1128C, 1107C, 36C, 43C, 37C, 215C, 316C, 315C, 544C, 412C, 58C AND 310C.
Condition: Unknown
Due 22 June 1996
Resolved 8 July 1996
Fire Fighting
Issued 21 June 1996
Resolved
PROVE PROPER OPERATION OF FIRE DAMPERS #33 AND 26.
Condition: Unknown
Due 22 June 1996
Resolved 8 July 1996
Accommodation/Occupational Safety
Issued 21 June 1996
Resolved
ADJUST ONE CLOSURE DOG ON WATERTIGHT DOOR 1102C PORT MAIN DECK.
Condition: Unknown
Due 28 June 1996
Resolved 8 July 1996
Navigation
Issued 21 June 1996
Resolved
PRIOR TO DEPARTURE CURRENTLY CORRECT BRITISH ADMIRALTY CHARTS WITH BRITISH ADMIRALITY CORRECTIONS.
Condition: Unknown
Due 21 June 1996
Resolved 23 July 1996
Fire Fighting
Issued 21 June 1996
Resolved
PRIOR TO CARRYING PASSENGERS IN U.S. WATERS, AFTER MAINTENANCE PERIOD (JULY1996), PROVE PROPER OPERATION OF ALL FIRE DOORS TO A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 29 July 1996
Resolved 29 July 1996
Documentation
Issued 21 June 1996
Resolved
PROVIDE COPY OF CORRECTIVE ACTIONS REQUIRED BY USPNS INSP DATED 5/10/96.
Condition: Unknown
Due 7 October 1996
Resolved 7 October 1996
Lifesaving
Issued 19 March 1996
Resolved
DEMONSTRATE LIFEBOAT DRILL WITH THE STBD SIDE BOATS.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Lifesaving
Issued 19 March 1996
Resolved
PROVIDE FLAG STATE APPROVED GENERAL ARRANGEMENTS & FIRE CONTROL PLANS TO THE MARINE SAFETY CENTER, WASH, D.C. SHOWING RECENT MODIFICATIONS (MODS SINCE LAST PLAN SUBMITTAL IN 1993).
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Lifesaving
Issued 19 March 1996
Resolved
PROVIDE FLAG STATE DOCUMENTATION INDICATING ACTUAL CAPACITY OF ALL LIFEBOATS & COMPARE UKRAINE CAPACITIES WITH NVIC 3-79 & ADJUST ACCORDINGLY.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Accommodation/Occupational Safety
Issued 19 March 1996
Resolved
PROVIDE PLAN WITH COMPLIANCE/TARGET DATES FOR ITEMS NOTED BY USPHS (14 ITEM)
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Construction/Loadline
Issued 19 March 1996
Resolved
MARK NAME OF VESSEL AND HOMEPORT IN LATIN ON BOW AND STERN OF THE VESSEL.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Lifesaving
Issued 21 March 1993
Resolved
EXIT SIGN BY CABIN 3006 IS POINTING IN WRONG DIRECTION - CORRECT LIFESAVINGPLAN ALSO.
Condition: Unknown
Due 22 March 1993
Resolved 2 April 1993
Lifesaving
Issued 21 March 1993
Resolved
EXIT SIGN BY CABIN 2012 IS POINTING IN WRONG DIRECTION - CORRECT LIFESAVINGPLAN ALSO.
Condition: Unknown
Due 23 March 1993
Resolved 2 April 1993
Fire Fighting
Issued 21 March 1993
Resolved
FIRE SCREEN DOORS IN EGRESS ROUTES FROM CAFE (AFT DINING AREA, UPPER DECK) SWING AGAINST EGRESS, RELOCATE DOORS SUCH THAT THEY SWING IN THE DIRECTION OF EGRESS AND MAINTAIN PROPER FIRE BOUNDARIES. RELOCATED DOORS SHALL NOT BLOCK OTHER EXITS OR EMERGENCY EQUIPMENT.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Lifesaving
Issued 21 March 1993
Resolved
PROVIDE EMERGENCY EGRESS SIGNAGE TO CLEARLY SHOW ROUTES TO THE EMBARKATION DECKS. PROVIDE ADDITIONAL SIGNS, ARROWS AND LIGHTS SUCH THAT ALL EGRESS ROUTES ARE CLEARLY INDICATED. REMOVE ALL SIGNS CAPABLE OF CAUSING CINFUSION ON THE PART OF PERSONS SEEKING EMERGENCY EGRESS.
Condition: Unknown
Due 22 March 1993
Resolved 2 April 1993
Fire Fighting
Issued 21 March 1993
Resolved
VERANDA BAR GLASS DOOR SWINGS IN POSITION PARTIALLY BLOCKING EGRESS TO AFT STAIRS. RELOCATE GLASS DOORS.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Lifesaving
Issued 21 March 1993
Resolved
LUBRICATE ALL WIRE ROPES ATTACHED TO LIFEBOAT AND LIFERAFT DAVITS BY NEW ORLEANS.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Fire Fighting
Issued 21 March 1993
Resolved
PROVIDE AN "A" CLASS SEPARATION OF STAIRS FROM REFRESHMENT STORE ROOM. AIRCONDITIONER BREACHES STAIR BOUNDARY.
Condition: Unknown
Due 21 March 1993
Resolved 2 April 1993
Lifesaving
Issued 21 March 1993
Resolved
REMOVE LOCKS FROM ALL GLASS DOORS THAT PROHIBIT EVACUATION WITHOUT A KEY.
Condition: Unknown
Due 21 March 1993
Resolved 2 April 1993
Lifesaving
Issued 21 March 1993
Resolved
ENSURE SHOW LOUNGE ON DECK 1 EXIT SIGNS ARE VISISBLE. FORWARD BLKHD PORT & STARBOARD SIDES, EXITS ARE BLOCKED BY RED CURTAINS. REMOVE CURTAINS.
Condition: Unknown
Due 21 March 1993
Resolved 2 April 1993
Lifesaving
Issued 21 March 1993
Resolved
EXIT SIGN BY CABIN 4016 IS POINTING IN WRONG DIRECTION - CORRECT LIFESAVINGPLAN ALSO.
Condition: Unknown
Due 22 March 1993
Resolved 2 April 1993
Lifesaving
Issued 21 March 1993
Resolved
REPAIR GLASS WINDOWS IN LIFEBOAT NUMBER 10 BY NEW ORLEANS.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Lifesaving
Issued 21 March 1993
Resolved
REMOVE OIL AND WATER FROM BILGES OF ALL LIFEBOATS PRIOR TO ENTRY LOS ANGELES.
Condition: Unknown
Due 22 March 1993
Resolved 2 April 1993
Lifesaving
Issued 21 March 1993
Resolved
REPLACE ENGINE FAN BELT FOR LIFEBOAT NUMBER 6 PRIOR TO ENTRY LOS ANGELES.
Condition: Unknown
Due 22 March 1993
Resolved 2 April 1993
Lifesaving
Issued 21 March 1993
Resolved
REPAIR HATCH COVER FOR LIFEBOAT NUBMER 10 TEMPORARILY UNTIL NEW ONE RECEIVED FROM GERMANY.
Condition: Unknown
Due 22 March 1993
Resolved 2 April 1993
Lifesaving
Issued 21 March 1993
Resolved
PROVIDE DOCUMENTATION OF FLAG ACCEPTANCE OF REPAIRS TO HULL OF LIFEBOAT #9 BY PROVIDING USCG MSO S.F. BAY WITH THE ABS REPORT.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Lifesaving
Issued 21 March 1993
Resolved
REMOVE COMBUSTIBLES IN PROVISION STORE STAIRWAY PRIOR TO ENTRY LOS ANGELES.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 21 March 1993
Resolved
OBTAIN A CLASSIFICATION SOCIETY REPORT STATING THE NUMBER 2 DAVIT FALLS ARESATISFACTORY AND PROVIDE REPORT TO MSO S. F. BAY. IF REPORT IS NOT RECEIVED BY 09 APR 93, THE FALLS MUST BE REPLACED IN NEW ORLEANS.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Fire Fighting
Issued 21 March 1993
Resolved
PROVIDE DOCUMENTATION FROM FLAG ADMIN/CLASS SOCIETY THAT ALL FIRE HOSES ON BOARD HAVE BEEN TESTED AND ARE IN SATISFACTORY CONDITION BY PROVIDING COPY OF ABS REPORT.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Fire Fighting
Issued 21 March 1993
Resolved
TEST ALL FIRE HOSES, WITH THE EXCEPTION OF THE MACHINERY SPACE FIRE HOSES, IN THE PRESENCE OF A MARINE INSPECTOR IN NEW ORLEANS AND NO LATER THAN 30 APR 93.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Lifesaving
Issued 21 March 1993
Resolved
REPLACE AS NECESSARY THE GREASE FITTINGS LOCATED ON THE 10 SETS OF LIFEBOATDAVITS AND GREASE DAVITS PRIOR TO ENTRY LOS ANGELES.
Condition: Unknown
Due 22 March 1993
Resolved 2 April 1993
Lifesaving
Issued 21 March 1993
Resolved
CONDUCT A LIFEBOAT DRILL WITH THE STARBOARD LIFEBOATS DURING NEXT U.S. PORTCALL IN THE PRESENCE OF A USCG MARINE INSPECTOR (LOS ANGELES).
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993