DISCOVERY SUN is a 1968 passenger vessel (inspected). The Coast Guard has recorded 133 inspections since 1986, most recently in January 2011, along with 98 deficiencies and 13 operational controls.

Records from 1986 to 2011. Most recent: operational control imposed, 28 January 2011.

Built
1968
Last inspected
27 January 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6815158 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
223209
Flag
PANAMA
—
Maury page id
psix-223209

Inspections, by type

…with no type recorded43
Years with a record 24 calendar years (1986–2011)
The 133 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it9903 - Regulatory (Subpart C or D), Gross Ton
11979 - Convention (Subpart B), Gross Ton
4005 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ISLAND ADVENTURE Passenger (Inspected) · MISLE 384482 · 13 February 2008 · activity 3147960REGAL EMPRESS Passenger (Inspected) · MISLE 221233 · 25 February 2005 · activity 2299349ASPHALT COMMANDER Tank Ship · MISLE 511750 · 25 February 2005 · activity 2299349GENCO PROVENCE Freight Ship · MISLE 733220 · 25 February 2005 · activity 2299349

Inspection history · 133

27 January 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3934686
27 January 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3937040
8 December 2010 ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3906210
8 December 2009 COC-CVE Annual · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3646755
4 April 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3446195
10 December 2008 ISPS II Exam · COC-CVE Annual · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3376928
22 November 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3367585
20 November 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3366553
20 November 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3367072
4 November 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3357133
1 October 2008 PII Safety Exam · COC-CVE Quarterly · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3334914
11 June 2008 COC-CVE Quarterly · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3232764
4 March 2008 ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3158213
13 February 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3147960
8 February 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3151018
12 December 2007 PII Safety Exam · Ballast Water Examination · MARPOL Annex II Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3113334
24 October 2007 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3085928
24 October 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3124074
10 July 2007 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2991291
6 June 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2953202
3 April 2007 ISPS III Exam · Ballast Water Examination · NPV Safety Exam · COC-CVE Quarterly · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2899905
3 January 2007 COC-CVE Annual
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2851116
3 October 2006 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2792805
12 July 2006 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2710560
5 July 2006 ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination · NPV Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2703755
21 June 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2687342
15 June 2006 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2686212
14 April 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2624744
3 April 2006 COC-CVE Quarterly · MARPOL Annex I Examination · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2615741
3 January 2006 ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2559546
4 October 2005 MARPOL Annex I Examination · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2507935
29 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2443907
6 July 2005 Ballast Water Examination · COC-CVE Quarterly · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2423718
29 May 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2372149
2 May 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2347406
21 April 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2339860
18 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2337119
18 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2339612
11 April 2005 Ballast Water Examination · MARPOL Annex I Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2330952
25 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2299349
3 January 2005 COC-CVE Annual
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2268181
6 October 2004 COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2215495
10 August 2004 Random ISPS/MTSA/PSC
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2161889
8 August 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2162035
30 July 2004 COC-CVE Quarterly
Type not classified · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2150639
30 June 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2116000
5 May 2004 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2060028
5 April 2004 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2038020
9 January 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1980920
5 January 2004 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1974831
9 September 2003 Certificate of Compliance · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1900713
28 July 2003 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1859861
27 February 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1751214
28 January 2003 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1735740
4 October 2002 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1684712
2 October 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1683587
19 September 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1677853
8 August 2002 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1658230
3 July 2002 Security Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1643832
4 February 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1483813
31 January 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1482901
18 September 2001 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1418963
4 June 2001 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1065378
21 March 2001 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1370054
8 October 2000 Quarterly Examination · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1452719
19 June 2000 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1424940
28 March 2000 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1455835
11 January 2000 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1365494
27 September 1999 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1441565
22 July 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1102975
19 July 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1104997
16 July 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1098896
28 June 1999 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1438861
14 June 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 809435
30 March 1999 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1410068
11 January 1999 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1426162
7 December 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 807273
19 October 1998 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 801744
6 July 1998 MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1378404
30 March 1998 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1458502
5 January 1998 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1427445
6 October 1997 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1364425
13 July 1997 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1380926
3 July 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 15975
1 April 1997 Control Verification · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1394704
16 January 1997 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1439815
26 November 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 873939
10 October 1996 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1374759
30 July 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1434427
2 July 1996 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1355860
29 June 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 131335
25 June 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1392494
3 April 1996 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1424205
6 December 1995 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1187963
25 October 1995 Administrative
Administrative · Marine Safety Center (MSC) · Activity 873981
12 September 1995 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 881959
30 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 184418
30 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 191558
30 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 765369
16 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 382130
6 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 381518
26 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 381001
24 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 22327
7 June 1995 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1400183
5 April 1995 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 858132
20 February 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 945336
24 April 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 915284
26 March 1991 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 997819
2 January 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 905094
22 October 1990 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1218758
31 July 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 926785
10 April 1990 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1214389
10 January 1990 Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1221125
1 December 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 926124
1 December 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 926602
3 August 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1206802
25 April 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1347535
7 February 1989 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1032052
23 January 1989 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1031055
16 January 1989 Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1201992
7 October 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1193787
13 July 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1208129
6 April 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 992725
9 March 1988 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1336428
13 January 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1014305
7 October 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1015347
1 July 1987 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1026855
1 April 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1023274
1 April 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1023283
15 October 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1016805
16 July 1986 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 992849
9 April 1986 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 997073
9 January 1986 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 990102

Deficiency record · 98

Engineering › Diesel Engine (propulsion-direct drive) › Piston Ring
Issued 27 January 2011 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Starboard main engine had a crankcase explosion due to blow through on cylinder #13. Provide class report attesting to repairs. (SOLAS 2009 I/II)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2011
Resolution: Received class report 28JAN11 attesting to proper repairs.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 8 December 2010 Resolved
Cruise Director's Office is missing escape markings
Due 8 December 2010
Resolved 8 December 2010
Fire Fighting › Means of Escape › Emergency Lighting
Issued 8 December 2010 Resolved
Low level photoluminescent strips on decks 5,4 and 3 do not show light reactivity. Recomend test survey.
Action required: 705 - Other - as specified
Due 8 January 2011
Resolved 9 June 2011
Resolution: Class report attest to repairs.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 8 December 2010 Resolved
Waste reptacles onboard other than those carrying wet waste or bottles and cans are not constructed of non-combustible material.
Action required: 705 - Other - as specified
Due 8 January 2011
Resolved 9 June 2011
Resolution: Deficiency was written using Solas 04, and not the appropriate Solas 60.
Fire Fighting › Means of Escape › Mimic Plans
Issued 8 December 2010 Resolved
Office in main galley, deck 6, starboard side constitutes a room-in-room arrangment and does not have equivalent level of safety as 2 direct escape routes. Vessel must provide equivalent level of safety by installing alarm in galley or window in door, or discontinue using space as office.
Action required: 705 - Other - as specified
Due 8 January 2011
Resolved 9 June 2011
Resolution: Class attest to repairs.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 December 2010 Resolved
In AC Room Storage and Garbage Room, lights are missing from receptacles and light covers are broken or missing.
Due 8 December 2010
Resolved 8 December 2010
Fire Fighting › Water Fog Applicators › Condition
Issued 8 December 2010 Resolved
Smoke detector 1024 in the steering gear space is not functional. Further, a hi-fog sprinkler head in the garbage room is bent, painted over, and is missing an ampule.
Due 8 December 2010
Resolved 8 December 2010
Fire Fighting › Structural - A Class Divisions › Store-rooms
Issued 8 December 2010 Resolved
"A" class deck boundary overhead generator storage space and also overhead electrical locker forward of the galley are both missing insulation.
Due 8 December 2010
Resolved 8 December 2010
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 24 October 2007 Resolved
Echo depth sounder inoperable. CG needs to be notified of inop depth sounder prior to departure and entry into US waters.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2008
Resolution: Def corrected
Lifesaving › Lifeboat › Handholds/Handrails
Issued 3 April 2007 Resolved
Hand rails on #2 lifeboat are rusted and derailed. Padeyes are loose as well. All life-saving appliances shall be in working order and ready for immediate use. Recommend class survey lifeboats for operational readiness.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 6 June 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 3 April 2007 Resolved
Tween deck forward laundry space emergency lighting did not work when power was de-energized.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 6 June 2007
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 3 January 2007 Resolved
Lifejackets locker deck 6 portside missing required markings
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 3 January 2007
Resolution: Corrected on the spot
Engineering › Fuel Oil Service System › Valve
Issued 3 January 2007 Resolved
Quick closing F/O tank is missing key from the break glass
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 3 January 2007
Resolution: Corrected on the spot
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 3 January 2007 Resolved
Combustible storage items found in electrical locker on deck 7 LM-LP-EP-206
Action required: 705 - Other - as specified
Due 3 February 2007
Resolved 3 February 2007
Resolution: Corrected on the spot
Stability › Watertight Integrity › Weathertight Enclosure
Issued 5 July 2006 Resolved
AFT CARGO RAMP IS NOT LOCKING SHUT. WATERTIGHT AND WEATHERTIGHT INTEGRITY IS COMPROMISED
Action required: 705 - Other - as specified
Due 14 July 2006
Resolved 7 August 2006
Resolution: TTS Marine inc. replaced 3 cylinder cassette type locks. 3 upper locks were re-sealed and pressure tested. Chalk integrity test coducted by Class surveyor. Ramp is monitored from bridge via cctv and indicator. Aft ramp has all 11 locks operational.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 5 July 2006 Resolved
All sprinkler section valves located in public spaces are not tamper proof.
Action required: 705 - Other - as specified
Due 13 July 2006
Resolved 24 July 2006
Resolution: All spinkler section valves located in public spaces have been made tamper proof.
Documentation › Certificates/Documents › Passenger Ship Safety Certificate
Issued 5 July 2006 Resolved
CERTIFICATE OF CLASSIFICATION LISTS VESSEL TYPE AS A FERRY VESSEL. VESSEL TYPE NEEDS TO BE VERIFIED.
Action required: 705 - Other - as specified
Due 6 August 2006
Resolved 7 August 2006
Resolution: Certificate and vessel type have both been verified by class.
Construction/Loadline › Structures › Door
Issued 5 July 2006 Resolved
FIRE SCREEN DOOR 6A ON DECK 08 IS WARPED AND DOES NOT SEAL PROPERLY.
Action required: 705 - Other - as specified
Due 6 August 2006
Resolved 24 July 2006
Resolution: Fire screen door 6a on deck 08, has been replaced and doors does seal properly.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 5 July 2006 Resolved
RECOMMEND THIRD PARTY AUDIT OF VSL'S SMS REPORTING PROCEDURES FOR EQUIPMENT FAILURE AND PROCEDURES FOR ENSURING WATERTIGHT INTEGRITY
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 24 July 2006
Resolution: Internal shipboard audit completed 21 july 2006. Master shall ensure log book entries prior to all voyages & completion of SAF 24 (Bridge departure checklist) Master shall sign SAF 24. ISM form OP66 for "repair orders", ISM form SAF 3 weekly checks.
Electrical › Lighting (service) › Conductor
Issued 4 October 2005 Resolved
Overhead in disco has several extension chords and colored lighting around dance floor not permanent installed.
Due 5 November 2005
Resolved 13 October 2005
Resolution: Recieved the class report. Removed extension chords from overhead.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 4 October 2005 Resolved
Several electrical chords penertrate the aft disco bulkhead outside; not properly sealed.
Due 5 November 2005
Resolved 13 October 2005
Resolution: Recieved class repor. Sealed all penertrations.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 October 2005 Resolved
Fire doors need to be adjusted 13, 18 and 56A.
Due 5 October 2005
Resolved 5 October 2005
Resolution: Adjusted doors.
Lifesaving › Lifeboat › Markings
Issued 4 October 2005 Resolved
Reflective tape needs to be replaced.
Due 5 November 2005
Resolved 13 October 2005
Resolution: Tape replaced.
Lifesaving › Lifeboat › Hull
Issued 4 October 2005 Resolved
Several little acces holes left unfilled.
Due 5 October 2005
Resolved 13 October 2005
Resolution: Filled in holes.
Lifesaving › Lifeboat Equipment › Hatchet
Issued 4 October 2005 Resolved
All axes are severely corroded.
Due 5 November 2005
Resolved 13 October 2005
Resolution: Replaced axes.
Lifesaving › Launching Appliances › Block
Issued 4 October 2005 Resolved
Number 2 lifeboat aft block wasted.
Due 5 November 2005
Resolved 13 October 2005
Resolution: Renewed davit block.
Fire Fighting › Miscellaneous Items › Cellulose-nitrate-based Films
Issued 4 October 2005 Resolved
Needs to be replaced in aft starboard crew stair well.
Due 5 November 2005
Resolved 13 October 2005
Resolution: Recieved class report. Replace photoluminis tape.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 July 2005 Resolved
Port side raw water pipeing to the main lube oil cooler is wasted and holed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 July 2005
Resolution: LLoyds attested to temporary repairs.
Deck/Cargo › Ballast › Piping
Issued 6 July 2005 Resolved
Ballast water pipeing located next to port side sea chest is wasted and holed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 July 2005
Resolution: LLoyds attested to temporary repairs.
Lifesaving › Lifeboat › Hull
Issued 6 July 2005 Resolved
Number one lifeboat damaged during abandon ship drill repair to the satisfaction of class.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 July 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Lifesaving › Lifeboat › Hull
Issued 6 July 2005 Resolved
Lifeboat hulls have numerous unapproved repairs and blistering in the fiberglass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 6 July 2005 Resolved
Embarkation ladders made by crew. Have class approve. Or provide proper embarkation ladders.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 July 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 6 July 2005 Resolved
Several breakers on lighting panel in main control have been replaced and are overrated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 6 July 2005 Resolved
Pin hole in pipeing to number four generator jacket water cooling system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Fire Fighting › Structural - A Class Divisions
Issued 5 April 2004 Resolved
The following FSD's are not making a proper boundary: 5, 7, 2, 8, 6B, 8A, 16, 18, 16A, 15, 17, 19, 25, 23. The FSD's were only checked on decks 5 and up. Repair all FSD's onboard vessel, and have all FSD's checked by the Flag State Rep. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 6 May 2004
Resolved 5 May 2004
Documentation › Safety/Response Plans/Programs
Issued 9 September 2003 Resolved
Provide an up to date fire control and safety plan. Make vessel available for veritifaction of plans. LEGACY COMPONENT DESC: Fire Control Plans
Due 1 December 2003
Resolved 5 January 2004
Fire Fighting › Structural - A Class Divisions
Issued 28 July 2003 Resolved
During fire drill with smoke machine, it was found that the bulkhead between the A/C room and Tropical Lounge Bar Pantry not smoke tight. Find holes and renew bulkhead to A Class as per SOLAS and the Fire Control Plans. Make permanent and proper repairs to the satisfaction of Class. LEGACY COMPONENT DESC: Bulkheads - Aux Spaces (moderate fire risk)
Due 15 August 2003
Resolved 11 August 2003
Resolution: Cleared by Class
Fire Fighting › Miscellaneous Items
Issued 28 July 2003 Resolved
Hotel Mangers Office and stow in a proper flammable locker to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Paint/Flammable Liquid Lockers
Condition: Improper Installation
Due 1 September 2003
Resolved 3 September 2003
Resolution: Cleared on board, CHK.
Fire Fighting › Combustible Materials
Issued 28 July 2003 Resolved
Excessive amount of dust in false over head of the Starlight show room on deck 5 resulting a fire hazard. Clean out area, check for dead end and improper wiring and make available for inspection to the attending USCG Marine Inspector LEGACY COMPONENT DESC: Ceilings
Condition: Improper/Lack of Maintenance
Due 1 September 2003
Resolved 3 September 2003
Resolution: Cleared on board, CHK.
Fire Fighting › Structural Fire Protection - General
Issued 28 July 2003 Resolved
Washer and dyer have been added in a locker with exposed electrical panels, forward on deck 5. Have class approve the installation and update fire control plans or return to original state LEGACY COMPONENT DESC: Accommodation Space Protection
Due 1 September 2003
Resolved 3 September 2003
Resolution: Cleared on board, CHK.
Fire Fighting › Structural Fire Protection - General
Issued 28 July 2003 Resolved
Forward end of car deck has been turned into a welding/work shop with improper stowage of oxygen and acetylene. Remove all work shop items and restore to original or built a proper workspace and flammable storage in accordance with the latest regulations. Any alterations will have to be approved b LEGACY COMPONENT DESC: Accommodation Space Protection
Due 15 August 2003
Resolved 11 August 2003
Resolution: Cleared by Class
Fire Fighting › Structural - A Class Divisions
Issued 28 July 2003 Resolved
Locker port side forward on deck 2 in stairway forward of Laundry is marked as Safety Gear, however it is full of boxes and other combustibles, not safety gear. Remove all items from locker and seal (weld) door closed to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Bulkheads - Store-rooms
Condition: Placed in Improper Service
Due 15 August 2003
Resolved 11 August 2003
Resolution: Cleared by Class
Fire Fighting › Structural - A Class Divisions
Issued 28 July 2003 Resolved
Door to A/C room aft on port side of deck 4 not closing properly. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 15 August 2003
Resolved 11 August 2003
Resolution: Cleared by Class
Fire Fighting › Structural - A Class Divisions
Issued 28 July 2003 Resolved
Locker, stbd side forward on deck 2 across from laundry room in the stairway, is marked as Safety Gear, however it is full of deck equipment, line throwing guns, boxes and other combustibles, not safety gear. Remove all items from locker and seal (weld) door closed to the satisfaction of the atten LEGACY COMPONENT DESC: Decks - Store-rooms
Condition: Placed in Improper Service
Due 15 August 2003
Resolved 11 August 2003
Resolution: Cleared by Class
Fire Fighting › Structural - A Class Divisions
Issued 28 July 2003 Resolved
Lube oil tank site gauge and alarm in stairway, gauge is leaking down the bulkhead. Have Class attest to the location of the tank in regards to the stairway and proper insulation as well as the leak repair. LEGACY COMPONENT DESC: Decks - Stairways
Condition: Improper Installation
Due 1 November 2003
Resolved 28 October 2003
Resolution: Complete A-60 bonderary built around tank
Stability › Watertight Integrity
Issued 28 July 2003 Resolved
An existing Condition of Class on the stern ramp covers the damages that occurred during a recent incident. In addition to that condition, the door gasket has deteriorated, the hand rails are broken and there is wasted metal throughout the knife edge and gasket channel. LEGACY COMPONENT DESC: Stern Ram
Condition: Improper/Lack of Maintenance
Due 1 September 2003
Resolved 3 September 2003
Resolution: Cleared on board, CHK.
Fire Fighting › Structural - A Class Divisions
Issued 28 July 2003 Resolved
The area around the embarkation side shell door on the port side deck 4, has three lockers opening into the stairway. One locker is for spill gear, spill gear is not safety gear and other combustibles are in that locker as well. Empty all three lockers and seal (weld ) doors closed, check stbd si LEGACY COMPONENT DESC: Decks - Store-rooms
Condition: Placed in Improper Service
Due 1 September 2003
Resolved 3 September 2003
Resolution: Cleared on board, CHK.
Documentation › Safety/Response Plans/Programs
Issued 28 July 2003 Resolved
Due to several modifications since the last USCG Plan Review and the number discrepancies noted in the fire control plan, you are required to submit Class approved structural fire protection drawings for the entire vessel to the Coast Guard's Marine Safety Center (MSC) by August 15, 2003 for plan r LEGACY COMPONENT DESC: Fire Control Plans
Condition: Improper/Lack of Maintenance
Due 1 September 2003
Resolved 3 September 2003
Resolution: Cleared on board, CHK.
Accommodation/Occupational Safety › Occupational Safety
Issued 29 January 2003 Resolved
Have class address hydraulic leak in port side escape trunk containing hydraulics for Ro/Ro ramp located on car deck 4. Lube oil is leaking from hydraulics lines in the overhead on to the deck.
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 27 February 2003
Fire Fighting › Fire Main
Issued 28 January 2003 Resolved
Have class adress fire main isolation valve packing that is leaking in the overhead of car deck 4 IWO frame 80. LEGACY COMPONENT DESC: Valves
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 27 February 2003
Stability › Weathertight Integrity
Issued 6 August 2002 Resolved
Repair/replace weathertight door (port side) leading from starlight show room to mooring deck. Repair IAW ILLC.
Action required: 705 - Other - as specified
Due 18 September 2002
Resolved 20 September 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 6 August 2002 Resolved
Have class address water pipe that is showing signs of leakage IWO FSD #47. CLass to provide report to MSO Miami. LEGACY COMPONENT DESC: water piping
Action required: 705 - Other - as specified
Due 18 September 2002
Resolved 20 September 2002
Engineering › Sea-water System (primary cooling)
Issued 6 August 2002 Resolved
Old deicing valve on port main sea chest valve wasted and weeping, replace or remove valve to satisfaction of class at next dry dock but prior to 18DEC02. Until proper repair add valve to engineer rounds and provide damage control equipment at valve. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 20 September 2002
Pollution Prevention/Response › Prevention Equipment
Issued 6 August 2002 Resolved
Small pipe in OWS discharge line between sensor and discharge valve. Remove valve to satisfaction of USCG. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 20 September 2002
Construction/Loadline › Structures
Issued 6 August 2002 Resolved
Hole wasted in overhead in port shaft alley (leading to crew galley). Make permenent repairs in yard to satisfaction of class.
Action required: 705 - Other - as specified
Due 18 October 2002
Resolved 20 September 2002
Fire Fighting › Structural - A Class Divisions
Issued 3 July 2002 Resolved
Fire Screen Door # 49, Deck 1, forward, STBD side is not self-closing due to broken cable LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2002
Resolved 3 July 2002
Resolution: Ship''''s crew repaired the FSD closure cable
Deck/Cargo › Cargo Stowage
Issued 3 July 2002 Resolved
Compressed gas cylinders carried as cargo were improperly stowed with acetylene and oxygen together LEGACY COMPONENT DESC: Compressed Gas cylinders
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2002
Resolved 3 July 2002
Resolution: Ship''''''''s crew segragated bottles on to different pallets
Accommodation/Occupational Safety › Occupational Safety
Issued 3 July 2002 Resolved
Ship's stores of compressed gas cylinders were improperly / not secured for voyage LEGACY COMPONENT DESC: Compressed gas cylinders
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2002
Resolved 3 July 2002
Resolution: Ship''''s crew secured the compressed gas cylinders in the dedicated racks
Fire Fighting › Structural Fire Protection - General
Issued 4 February 2002 Resolved
Update Fire Control Plan, have class provide report LEGACY COMPONENT DESC: Superstructure Construction
Due 5 March 2002
Resolved 6 August 2002
Lifesaving › Lifejacket/PFD (Type III)
Issued 4 February 2002 Resolved
Post number labels on lifejacket locker IAW SOLAS III/20-10. LEGACY COMPONENT DESC: Storage
Due 5 March 2002
Resolved 6 August 2002
Operations/Management › Mandatory Ship Reporting Systems
Issued 31 January 2002 Resolved
Since October 2001, vessel has failed to provide a 24 hour advanced notice of arrival for a voyages more than 24 hours LEGACY COMPONENT DESC: Entry Report
Condition: Unknown
Due 31 January 2002
Resolved 6 August 2002
Fire Fighting
Issued 18 September 2001 Resolved
Repair and Prove operation of Fire Main Isolation Valve Reach Rods on Car Deck.
Condition: Unknown
Due 18 September 2001
Resolved 18 September 2001
Engineering
Issued 21 March 2001 Resolved
Provide guard for gear in fan room# 10.
Condition: Unknown
Due 21 March 2001
Resolved 21 March 2001
Accommodation/Occupational Safety
Issued 21 March 2001 Resolved
Have classs address use of plastic trash containers on vsl.
Condition: Unknown
Due 21 March 2001
Resolved 21 March 2001
Fire Fighting
Issued 8 October 2000 Resolved
Demonstrate compliance with SOLAS retroactive fire safety amendment _x001C_ II-2/41-2.6.3. Flag has extended deadline from 1 October 2000 to 1 January2001.
Condition: Unknown
Due 8 October 2000
Resolved 8 October 2000
Navigation
Issued 11 January 2000 Resolved
Prior to 03JAN00, provide class report on proper operation of rudder angle indicator at all steering stations.
Condition: Unknown
Due 11 January 2000
Resolved 11 January 2000
Engineering
Issued 11 January 2000 Resolved
Prior to bunkering in U.S. ports, provide Oil Transfer Procedures that meetU.S. regulations (33 CFR 155.750).
Condition: Unknown
Due 11 January 2000
Resolved 11 January 2000
Documentation
Issued 28 June 1999 Resolved
No later than 28JUL99, have class society address the fact that the loadline marking on the hull does not match the Loadline Certificate.
Condition: Unknown
Due 28 June 1999
Resolved 28 June 1999
Lifesaving
Issued 28 June 1999 Resolved
No later than 28JUL99, have class society address whether or not the 3/4" diameter polypropylene line used as bowsing tackle for lifeboats has a safeworking load adequate for this application.
Condition: Unknown
Due 28 June 1999
Resolved 28 June 1999
Lifesaving
Issued 11 January 1999 Resolved
No later than 30 Mar 99 make water light stored at port side boat deck below life boat #10 float free. Current arrangement does not allow light tofloat free with deck buoy.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 11 January 1999 Resolved
No later than 30 Mar 99 provide and install machinery guard on accomadationfan motor in ventilator space #8.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 11 January 1999 Resolved
Immediately remove flammables from port side bunker station.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Fire Fighting
Issued 19 October 1998 Resolved
Provide Class report addressing containers on the car deck used as deep freeze and dry stores. They are not provided with smoke detectors. These containers are not on trailers and seem to be a permanently installed. IAWSOLAS 74 Amended, Chapter II-2, Reg. 41-2.2.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Engineering
Issued 30 March 1998 Resolved
Provide class statement concerning the condition of the fuel supply/return lines on the main engine injector pumps.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Construction/Loadline
Issued 30 March 1998 Resolved
Prove proper operation of all watertight door indicators.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Lifesaving
Issued 6 October 1997 Resolved
Prior to next quarterly examination provide low level lighting markings foropposite fire hoses and stations
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Construction/Loadline
Issued 13 July 1997 Resolved
WATERTIGHT DOOR # 5 WAS NOT OPERABLE FROM BULKHEAD DECK. MUST FIX AND MAKEOPERABLE FROM BULKHEAD DK. PRIOR TO 20JUL97. AS PER SOLAS 74 CH II-1 REG 24.
Condition: Unknown
Due 13 July 1997
Resolved 13 July 1997
Construction/Loadline
Issued 10 October 1996 Resolved
Emergency bilge suction valve is stuck in the closed position. Provide documentation from vessel's classification society that valve is satisfactory prior to 11 October 1996 departure.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Lifesaving
Issued 10 October 1996 Resolved
Revise the vessel's crew training manual to include information for all duites as stated on the muster list such as firefighting duites. SOLAS 1974 (amended), Chapter III, Regulation 51.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Lifesaving
Issued 30 July 1996 Resolved
Provide and install adequate lighting for the 4 newly installed life raft davits. The lighting shall be adequate for the davit operator and launching crew. SOLAS 1974 (amended), Chapter III, Regulation 15.7.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Lifesaving
Issued 30 July 1996 Resolved
Provide documentation from vessel's Flag Administration/Classification Society as to the minimum number of certified lifeboatmen required on board.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Engineering
Issued 26 July 1995 Resolved
PROVIDE CERTIFICATE OF CALIBRATION BY THE FACTORY REPRESENTATIVE, SIGNED BYTHE C/ENG AND THE FLAG SURVEYOR.
Condition: Unknown
Due 13 August 1995
Resolved 13 September 1995
Documentation
Issued 26 July 1995 Resolved
PROVIDE STATEMENTS OF ALL OFFICERS ON WATCH ON THE BRIDGE AND ENGINE ROOM DURING THE HOURS OF 1600 AND 2200 HOURS 24JUL95. TO BE DELIVERED TO THE CG MARINE SAFETY OFFICE NLT 0900 27JUL95.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Engineering
Issued 26 July 1995 Resolved
PROVE PROPER OPERATION OF THE OWS AFTER CERTIFIED CALIBRATION IN THE PRESENCE OF A CG INSPECTOR.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Engineering
Issued 26 July 1995 Resolved
CALIBRATE AND SERVICE THE OWS BY AN AUTHORIZED FACTORY REPRESENTATIVE TO THE SATISFACTION OF THE FLAG ADMINISTRATION.
Condition: Unknown
Due 13 August 1995
Resolved 13 September 1995
Lifesaving
Issued 7 June 1995 Resolved
VESSEL IS TO CONDUCT SATISFACTORY BOAT DRILL EXERCISING PORT SIDE LIFEBOATSIN THE PRESENSE OF A U.S.C.G. MARINE INSPECTOR PRIOR TO NEXT QUARTERLY CVE
Condition: Unknown
Due 7 June 1995
Resolved 7 June 1995
Electrical
Issued 5 April 1995 Resolved
SHIP IS PROVIDE PROOF OF PROPER OPERATION OF SHIP-SERVICE DIESEL GENERATOR NUMBER FOUR (#4 SSDG)
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Electrical
Issued 5 April 1995 Resolved
VESSEL IS TO CLEAR THE GROUND (EARTH) ON THE FIRST PHASE OF THE 220 VOLT EMERGENCY GENERATOR CONTROL PANEL
Condition: Unknown
Due 9 June 1995
Resolved 7 June 1995
Lifesaving
Issued 5 April 1995 Resolved
VESSEL IS TO REPLACE THE WASTED FIBERGLASS LIFEFLOAT
Condition: Unknown
Due 9 June 1995
Resolved 7 June 1995
Accommodation/Occupational Safety
Issued 5 April 1995 Resolved
VESSEL IS TO REPAIR OR REPLACE THE WASTED STEEL STAIRS LOCATED ON ANDROS DECK TO FOCS'L DECK FORWARD
Condition: Unknown
Due 9 June 1995
Resolved 7 June 1995
Lifesaving
Issued 5 April 1995 Resolved
VESSEL IS TO UPDATE FIRE/SAFETY PLANS TO SHOW ALL FIRE RATED BULKHEADS AND DRAFT STOPS IN GALLEY
Condition: Unknown
Due 9 June 1995
Resolved 7 June 1995
Lifesaving
Issued 5 April 1995 Resolved
VESSEL WAS UNABLE TO START THE MOTOR ON LIFEBOAT # 9
Condition: Unknown
Due 7 June 1995
Resolved 7 June 1995
Fire Fighting
Issued 5 April 1995 Resolved
VESSEL IS TO PROVIDE DOCUMENTATION THAT THE COMPRESSED AIR CYLINDERS FOR THE FIREFIGHTING SELF-CONTAINED-BREATHING-APPARATUS (S.C.B.A.) HAVE BEEN HYDROSTATICALLY TESTED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS
Condition: Unknown
Due 9 June 1995
Resolved 7 June 1995
Fire Fighting
Issued 5 April 1995 Resolved
VESSEL IS TO PROVIDE DOCUMENTATION THAT THE COMPRESSED CARBON DIOXIDE (CO2)BOTTLES HAVE BEEN PROPERLY HYDROSTATICALLY TESTED IN ACCORDANCE WITH NATIONAL STANDARDS
Condition: Unknown
Due 9 June 1995
Resolved 7 June 1995
Lifesaving
Issued 10 January 1990 Resolved
REPLACE MOTOR LIFEBOAT NO.9, AFTER THE RENEWAL OF BOTH DAVITS AND LAUNCHINGEQUIPMENT. LOAD TEST OF DAVITS TO BE CONDUCTED. 03 LIFERAFTS TO REPLACE LIFEBOAT UNTIL REPAIRS/LOAD TEST OF DAVITS.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Lifesaving
Issued 10 January 1990 Resolved
NO. 10 MOTOR LIFEBOAT. REPAIR A FRACTURE ON THE GUNNEL CAP, STBD SIDE OF BOAT, FORWARD ADJACENT TO OAR LOCK SUPPORT PLATE.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Fire Fighting
Issued 10 January 1990 Resolved
PROVE PROPER OPERATION OF THE FIRE DETECTION DEVICE IN PASSENGER CABIN NO. 361, NASSAU DECK.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Engineering
Issued 10 January 1990 Resolved
PROVE PROPER OPERATION OF THE STBD MAIN DIESEL ENGINE, AFTER ROUTINE OVERHAUL.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990

Ownership record