MAURY USCG vessel records Sign in
← All vessels

REGAL EMPRESS

REGAL EMPRESS is a 1953 passenger vessel (inspected). The Coast Guard has recorded 280 inspections since 1985, most recently in February 2024, along with 379 deficiencies and 4 operational controls.

Records from 1985 to 2024. Most recent: inspection, 27 February 2024.

Built
1953
Last inspected
27 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5262835 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
221233
Flag
SAINT KITTS AND NEVIS
—
Maury page id
psix-221233

Inspections, by type

…with no type recorded121
Years with a record 26 calendar years (1985–2024)
The 280 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it11236 - Regulatory (Subpart C or D), Net Ton
7700 - Dead Weight, Ton
22000 - Displacement, Ton
21909 - Regulatory (Subpart C or D), Gross Ton
21909 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 7

Inspection history · 280

27 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7870896
25 February 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3423769
11 February 2009 MARPOL Annex I Examination · COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3415578
2 January 2009 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3387753
2 January 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3387902
27 October 2008 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3352481
17 September 2008 Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3325873
25 August 2008 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3308761
16 June 2008 ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3238672
28 April 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3194512
8 April 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3179918
14 March 2008 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3164770
18 December 2007 PII Safety Exam · ISPS II Exam · COC-CVE Quarterly · MARPOL Annex V Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3117192
18 September 2007 MARPOL Annex I Examination · ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3060611
27 July 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3012975
19 June 2007 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2966712
20 March 2007 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2891302
22 September 2006 COC-CVE Annual · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2783642
28 June 2006 COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2693283
24 March 2006 COC-CVE Quarterly · MARPOL Annex I Examination · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2608114
20 March 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2605642
30 September 2005 COC-CVE Annual · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2504514
6 July 2005 MARPOL Annex I Examination · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2417456
18 April 2005 COC-CVE Quarterly · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2336232
14 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2309973
25 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2299349
5 January 2005 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2269418
12 October 2004 COC-CVE Annual
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2219060
15 July 2004 COC-CVE Quarterly · MARPOL Annex V Examination · NPV Safety Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2134329
8 June 2004 MTSA/ISPS Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2090931
19 May 2004 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2071919
15 April 2004 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2021492
9 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2040955
18 March 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2026821
10 March 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2022024
15 November 2003 Periodic Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1948247
16 October 2003 Deficiency Check · COC-CVE Annual
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1929713
23 September 2003 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1910803
4 September 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1896867
12 July 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1843853
18 June 2003 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1820535
14 March 2003 MARPOL Annex V Examination · Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1757169
3 March 2003 Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1751920
11 February 2003 Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1743184
24 January 2003 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1735239
6 December 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1715663
4 December 2002 In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1715528
18 November 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1707089
15 November 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1706099
13 November 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1704737
28 October 2002 Type not recorded
No type recorded · Station Cortez · USCG Southeast District (CGD-SE) · Activity 1700127
25 October 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1695962
20 October 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1692928
20 October 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1692932
12 October 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1689916
8 October 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1686433
4 October 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1684520
1 October 2002 Quarterly Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1682680
1 October 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1682801
20 September 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1678307
12 September 2002 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1674630
12 September 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1674774
5 September 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1671950
21 July 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1649566
3 July 2002 Security Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1640668
28 June 2002 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1638375
24 June 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1635918
21 June 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1634676
9 June 2002 Security Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1628307
12 May 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1615737
5 May 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1612875
3 May 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1612523
28 April 2002 Deficiency Check · Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1610132
21 April 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1607158
14 April 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1604586
14 April 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1604663
11 April 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1603550
11 April 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1603872
2 April 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1599935
2 April 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1600241
28 March 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1602737
24 March 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1597322
24 March 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1597378
24 March 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1597959
17 March 2002 Examination of Repairs · Security Inspection · Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1494216
9 March 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1492417
5 March 2002 Security Inspection · Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1492416
23 February 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1488645
22 February 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1490101
22 February 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1492473
18 February 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1487202
16 February 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1487140
16 February 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1487270
11 February 2002 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1486027
11 February 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1486554
9 February 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1485262
9 February 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1485284
27 January 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1481653
21 January 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1480114
19 January 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1480009
12 January 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1478462
4 January 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1475506
16 October 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 70569
5 October 2001 Port Security Assessment
Type not classified · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 614272
5 October 2001 Deficiency Check · Quarterly Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1074328
19 August 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 79600
19 August 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1075192
13 July 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 18425
25 June 2001 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1072997
19 June 2001 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 291119
7 June 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 290744
10 May 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1064874
7 April 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 288876
22 March 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 288317
22 March 2001 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1059837
18 January 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 286023
18 January 2001 Quarterly Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1056834
31 October 2000 Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1389216
29 October 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 46205
19 October 2000 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 715350
29 September 2000 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1389205
19 September 2000 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 92882
2 August 2000 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 280592
9 July 2000 Quarterly Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1439056
14 June 2000 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 278902
4 June 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 278465
23 May 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 134766
13 April 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 277954
13 April 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1404957
3 April 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 172197
2 April 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 95557
2 April 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 276723
2 April 2000 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 817122
13 January 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 273958
13 January 2000 Quarterly Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 814953
2 December 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 166837
28 November 1999 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 435205
30 October 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 75426
8 October 1999 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 887473
2 July 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 430268
2 July 1999 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1410130
29 May 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 147203
7 May 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 428329
7 May 1999 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 797977
9 April 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 692745
6 April 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 427335
6 April 1999 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 790135
6 March 1999 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1384091
13 February 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 9262
13 February 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 213280
2 February 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 52620
12 January 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 423462
12 January 1999 Quarterly Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 790127
26 December 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 131366
2 October 1998 Quarterly Examination · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 806642
28 August 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 419927
10 August 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 692747
3 July 1998 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1434746
29 June 1998 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 128037
27 June 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1438742
7 June 1998 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1130233
1 June 1998 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1433355
18 May 1998 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1127801
2 April 1998 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1433354
24 January 1998 Quarterly Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1437346
25 October 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1422960
26 September 1997 Quarterly Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1115844
2 July 1997 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 777419
20 June 1997 Deficiency Check · MARPOL Annex V Examination · Quarterly Examination · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1112510
2 June 1997 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 692744
17 May 1997 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1094207
13 May 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1109780
28 March 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 132009
28 March 1997 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1407856
15 March 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 402477
15 March 1997 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1450029
28 January 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 399901
28 January 1997 Quarterly Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1422810
5 December 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 877754
2 November 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1407777
13 October 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 458415
13 October 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 476851
13 October 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 511555
13 October 1996 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1153472
19 July 1996 Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1087138
3 June 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1374624
13 April 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 391790
13 April 1996 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1080366
18 March 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 389050
18 March 1996 Quarterly Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1079594
20 January 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 97257
20 January 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 387059
20 January 1996 Quarterly Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1187388
23 October 1995 Administrative
Administrative · Marine Safety Center (MSC) · Activity 1181033
13 October 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 383327
13 October 1995 Quarterly Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 880799
21 July 1995 MARPOL Annex V Examination · Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 872490
14 June 1995 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 379495
22 April 1995 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1151324
23 March 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 377244
13 January 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 374285
13 January 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1154459
10 December 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 94503
5 December 1994 Quarterly Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 833915
12 October 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 28161
12 October 1994 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 373030
12 October 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 871202
26 August 1994 MARPOL Annex I Examination · MARPOL Annex V Examination · Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1172975
19 August 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 54018
17 August 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 369454
17 August 1994 MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1178963
19 July 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 536133
6 July 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 868835
1 July 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 368279
11 June 1994 MARPOL Annex I Examination · Quarterly Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177411
10 June 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 692746
6 June 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 367639
6 June 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1356671
24 May 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 695745
10 May 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1169901
21 March 1994 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1166337
11 February 1994 Quarterly Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 853028
5 November 1993 Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 833913
21 October 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 961643
19 October 1993 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 692741
12 October 1993 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 692743
6 October 1993 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 692738
12 September 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 9248
12 September 1993 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 26461
11 September 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 692739
31 August 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 692740
30 August 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 360625
29 August 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 360516
22 August 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 142482
20 August 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 829869
17 August 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 137964
6 August 1993 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 830741
29 July 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 512055
24 July 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 178709
19 July 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 489798
17 June 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 359108
16 June 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 358907
15 June 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 681273
15 June 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 694461
13 June 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842801
12 May 1993 MARPOL Annex I Examination · Deficiency Check · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1138994
30 January 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 833823
31 October 1992 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 932486
8 August 1992 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1262562
29 June 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 960781
9 May 1992 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 950155
1 February 1992 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 945209
2 November 1991 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 942122
10 August 1991 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1246383
11 May 1991 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1306650
9 February 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 927722
29 December 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1233920
1 December 1990 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 919502
18 August 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 913555
19 May 1990 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1215222
24 March 1990 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 919234
23 December 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1235891
23 September 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1195440
10 June 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1196835
11 March 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 887382
17 December 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1210665
13 December 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1209474
10 September 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1040145
21 June 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 324085
11 June 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1198821
9 April 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 992730
2 January 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1315494
19 September 1987 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1314522
13 June 1987 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1001017
7 February 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1014570
8 November 1986 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1016952
16 August 1986 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1312472
7 June 1986 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 997954
15 March 1986 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 992710
18 May 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 302101

Deficiency record · 379

Engineering › Steering Gear System › Power Unit
Issued 2 January 2009 Resolved
Make proper repairs, to the satisfaction of class, to emergency steering switchboard, associated wiring, structural fire protection (SFP) and through bulkhead penetrations IAW SFP plan..
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2009
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 2 January 2009 Resolved
Provide class report to US Coast Guard Sector Miami, prior to departure from Port Everglades, attesting that proper repairs to emergency switchboard, wiring and SFP have been made and that the emergency steering system is operable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2009
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 25 August 2008 Resolved
Owner/operator has not received required authorization to operate on the navigable waters of the U.S. Nontank Vessel Response plans must meet the required elements of IAW 33 USC (j)(5)(D) for each Geographic Specific Area in which it operates.
Action required: 705 - Other - as specified
Due 25 August 2008
Resolved 27 October 2008
Resolution: Attended vessel to verify authorization to operate on the navigable waters of the U.S. was on board. The vessel has Non-Tank Vessel Reponse Plan with Houston-Galveston COTP zone information. The deficiency has been rectified.
Construction/Loadline › Markings › Load Line Mark
Issued 17 March 2008 Resolved
LAOADLINE ON VESSEL DOES NOT MATCH LOAD LINE MARKING ON CERTIFICATE.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 26 March 2008
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 17 March 2008 Resolved
SAFETY GUARDS MISSING ON EMERGENCY GENERATOR.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 26 March 2008
Documentation › Certificates/Documents › IOPP Certificate
Issued 14 March 2008 Resolved
CLASS SOCIETY NEEDS TO UPDATE IOPP CERTIFICATE IN REGARDS TO 2.4.1 AND 2.5 WHICH ADDRESSES FILTERING EQUIPMENT AND THROUGHPUT.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 26 March 2008
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 19 June 2007 Resolved
Replace all broken water jug caps on lifeboats.
Action required: 705 - Other - as specified
Due 19 July 2007
Resolved 27 July 2007
Resolution: Water jug caps were replaced with new ones.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 28 June 2006 Resolved
Starboard side stern tube is leaking excessively
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 28 June 2006
Resolution: Received Class report of def correction.
Fire Fighting › Grease Extraction Hood › General
Issued 30 September 2005 Resolved
Deep fat fryer and grill not indicated on fire plan and the proper installation shall be verified by class for fire protection.
Due 1 November 2005
Resolved 28 December 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 6 July 2005 Resolved
Fuses and breakers are missing from power panel in the ships chapel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 August 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 July 2005 Resolved
Internet cafe computers are wired improperly.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 August 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 July 2005 Resolved
Oxygen bottles improperly stored/secured. Permanently and properly store oxygen bottles.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 August 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Construction/Loadline › Structures › Superstructure
Issued 6 July 2005 Resolved
Gymnasium has been reclassified as a storage room/space. Have class reclassified.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 August 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Engineering › Fuel Oil Service System › Piping
Issued 12 October 2004 Resolved
Fuel supply line to the number 1 and 2 generator is leaking. Properly repair fuel leak to the satisfaction of the administration. Provide report to Sector Miami via fax prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2004
Engineering › Steam System (auxiliary) › Piping
Issued 12 October 2004 Resolved
There is an excessive amount of soot build-up in the starboard upper level of the boiler room. Determine the source of the exhaust leak and properly repair. Provide administration report to Sector Miami via fax.
Due 9 November 2004
Resolved 9 November 2004
Lifesaving › Lifeboat › Propeller Shaft
Issued 12 October 2004 Resolved
Output shaft couplings on the number 15 and 16 lifeboats are wasted. Replace both couplings to the satisfaction of the administration and provide report via fax to Sector Miami.
Due 26 October 2004
Resolved 14 October 2004
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 19 May 2004 Resolved
Have flag state rep address the categorization of current changing room aft of the main lounge. The space is being used as a technical space and should be properly categorized and structural fire protection must be changed accordingly.
Condition: Unknown
Due 15 September 2005
Resolved 6 January 2005
Stability › Watertight Integrity
Issued 15 April 2004 Resolved
WTD #4 currently does not have a visual indicator. Install a visual alarm/indicator for WTD #4. This door is in a high noise area in engine room. LEGACY COMPONENT DESC: WTD
Due 17 May 2004
Resolved 17 May 2004
Fire Fighting › Structural - A Class Divisions
Issued 15 April 2004 Resolved
Several compartments do not have proper structural fire protection and may not be categorized properly. Have FSR (BV) address the following items: lack of FSD between main galley and wine locker, no draught stops in grand lounge in false overhead, *See Special Note for additional Items*
Due 17 May 2004
Resolved 17 May 2004
Fire Fighting › Structural - A Class Divisions
Issued 15 April 2004 Resolved
The following fire screen doors are out of adjustment: #623 and #524. Make proper adjustments to both doors. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 17 May 2004
Resolved 17 May 2004
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 23 September 2003 Resolved
Sprinkler head blocked in Commodores Lounge. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Nozzles
Condition: Improper Installation
Due 8 October 2003
Resolved 16 October 2003
Electrical › Electrical Distribution System (service)
Issued 23 September 2003 Resolved
House hold surge protector being used through out the vessel and present a possible fire risk and overloading situation. Remove or replace with proper wiring in according to applicable regulation and safe marine practices to the satisfaction of the attending USCG Marine
Condition: Improper Installation
Due 8 October 2003
Resolved 16 October 2003
Fire Fighting › Structural Fire Protection - General
Issued 23 September 2003 Resolved
Washer and dryers have been added in two of the restrooms. Dryers not properly installed. Provide approved space and installation of Washer and Dryer to the satisfaction of Class. LEGACY COMPONENT DESC: Accommodation Space Protection
Due 8 October 2003
Resolved 16 October 2003
Fire Fighting › Means of Escape
Issued 23 September 2003 Resolved
Ladder to Dead-end Platform blocking Emergency Exit from Officers Mess. Remove ladder and proper repairs to the satisfaction of the attending USCG Marine Inspector.
Due 8 October 2003
Resolved 16 October 2003
Fire Fighting › Structural - A Class Divisions
Issued 23 September 2003 Resolved
Bulkhead to fan room on Promenade Deck wasted and holed. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper Installation
Due 8 October 2003
Resolved 16 October 2003
Lifesaving › Lifeboat
Issued 23 September 2003 Resolved
Tiller mount to rudder on Lifeboat Number #1 Cracked and fiberglass weakened on rudder to L/B #2. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector LEGACY COMPONENT DESC: Rudder/Tiller/Steering
Condition: Improper/Lack of Maintenance
Due 8 October 2003
Resolved 16 October 2003
Electrical › Lighting (emergency)
Issued 23 September 2003 Resolved
Stanchion to embarkation lighting wasted. Survey all lighting stanchions and mount. Make permanent and proper repairs as needed to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 8 October 2003
Resolved 16 October 2003
Lifesaving › Lifeboat
Issued 23 September 2003 Resolved
Grab rails to lifeboats #8 & 4, wasted and/or loose. Survey all grab rails and make permanent and proper repairs as needed to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Handholds/Handrails
Condition: Improper/Lack of Maintenance
Due 8 October 2003
Resolved 16 October 2003
Lifesaving › Launching Appliances
Issued 23 September 2003 Resolved
Manual handle wheel spins when life boat being lowered creating a hazard to personnel. Remove wheel when not in use or propose an alternate means of protection to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Davit
Condition: Design Flaw
Due 8 October 2003
Resolved 16 October 2003
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 23 September 2003 Resolved
Sprinkler Fresh Water Tank leaking at welded fitting on bottom of tank. Make permanent and proper repairs as needed and perform hydrostatic test to the satisfaction of the Class. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 8 October 2003
Resolved 16 October 2003
Engineering › Freshwater System (jacketwater cooling)
Issued 23 September 2003 Resolved
Salt water cooling piping to the emergency generator wasted and holed. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector.
Due 8 October 2003
Resolved 16 October 2003
Electrical › Electrical Distribution System (service)
Issued 23 September 2003 Resolved
Dead end wiring in engine room on STBD bulkhead in way of Ballast Valve # 18. Remove wiring or poperly terminate I to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 8 October 2003
Resolved 16 October 2003
Deck/Cargo › Ballast
Issued 23 September 2003 Resolved
Ballast Valve #18 leaking. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 8 October 2003
Resolved 16 October 2003
Fire Fighting › Structural - A Class Divisions
Issued 23 September 2003 Resolved
Upper Deck (Deck 7) has been closed in with glass. Have class survey area and atest to compliance to the applicable regulations concerning sprinklers and the traveling of lifeboats along the windows. In particular; regulations 26 and 12 of Chp II-2 SOLAS 74 un-ammended. LEGACY COMPONENT DESC: Bulkheads - Evacuation Stations
Condition: Improper Installation
Due 8 October 2003
Resolved 16 October 2003
Resolution: Flag state report states that this was originally an open deck.
Fire Fighting › Structural - A Class Divisions
Issued 23 September 2003 Resolved
Doors to fan rooms on promenade deck in crew stairways warped and won't close properly. Make permanent and proper repairs to the satisfaction of the attending USCG Marine LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 8 October 2003
Resolved 16 October 2003
Fire Fighting › Structural - Horizontal Zones
Issued 23 September 2003 Resolved
Over head in crew stairway (promenade deck) wasted and holed. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector
Condition: Improper/Lack of Maintenance
Due 8 October 2003
Resolved 16 October 2003
Electrical › Electrical Distribution System (service)
Issued 23 September 2003 Resolved
Improper wiring to motor in fan rooms in crew stairway promenade deck and in Fan Room # 3. Make permanent and proper repairs to the satisfaction of the attending USCG Marine LEGACY COMPONENT DESC: Cable
Due 8 October 2003
Resolved 16 October 2003
Fire Fighting › Structural - A Class Divisions
Issued 23 September 2003 Resolved
Ramps in doorways must be secured so they do not interfere with the closing of the doors. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper Installation
Due 8 October 2003
Resolved 16 October 2003
Electrical › Electrical Distribution System (service)
Issued 23 September 2003 Resolved
Improper stowage, dead end wires and improper wiring in electrical locker starboard side main deck. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 8 October 2003
Resolved 16 October 2003
Electrical › Lighting (emergency)
Issued 23 September 2003 Resolved
Ensure lights inside and out of fire gear lockers are on the emergency circuits. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 8 October 2003
Resolved 16 October 2003
Fire Fighting › Structural - A Class Divisions
Issued 23 September 2003 Resolved
The following fire screen doors were found deficient during the test of the doors from the bridge:Adjust the closing device on doors: 707, 605, 622, 514, 425, 426, 316, 455, 261Adjust the indicator on doors: 403, 528, 612Adjust the latch on door 435. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 8 October 2003
Resolved 16 October 2003
Operations/Management › Passenger Operations
Issued 18 June 2003 Resolved
As per order of Captain of the Port Miami the vessel is not to load passengers or move from berth until a Full Examination for Certification of vessel is complete. All deficiencies designated as Prior to Departing the Port must be completed and attested to by the flag state representative.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Electrical › Electrical Distribution System (service) › Cable
Issued 18 June 2003 Resolved
Numerous improperly wired light fixtures and outlets in the back stage area. Remove or properly terminate all dead end wiring and make permanent repairs to fixtures to the satisfaction of the attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 23 June 2003
Fire Fighting › Miscellaneous Items
Issued 18 June 2003 Resolved
Dust, wood, and other combustibles have accumulated in the overhead of the main theater presenting a fire hazard. Improper wiring also evident. Clear the area and make proper repairs to the satisfaction of the attending USCG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Electrical › Electrical Distribution System (service) › Cable
Issued 18 June 2003 Resolved
Improper wiring, and exposed fittings in the main theater and control booth areas. Make permanent and proper repairs to the satisfaction of the attending USCG Inspector
Action required: 705 - Other - as specified
Resolved 23 June 2003
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 18 June 2003 Resolved
Loose electrical panel in the control booth to the main theater, plastic is cracked and breakers are missing. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector. ( Also remove papers from inside of panel)
Action required: 705 - Other - as specified
Resolved 23 June 2003
Fire Fighting › Structural - Main Vertical Zones
Issued 18 June 2003 Resolved
All seating in the stairways must be of fire resistant material, limited to six person and affixed to the bulkhead or deck. . Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Resolution: All seating in the stairways must be of fire resistant material, limited to six person and affixed to the bulkhead or deck. . Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector
Operations/Management › Drills/Instruction › Abandon Ship
Issued 18 June 2003 Resolved
Life raft drill and life raft arrangements not in compliance. Present arrangement and manning does not allow rafts to be launched in thirty minutes. Submit interim and permanent repair proposal to Captain of the Port (COPT) Miami.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Lifesaving › Launching Appliances › Davit
Issued 18 June 2003 Resolved
Lifeboat #16 could not clear the rail due to modifications of the fendering system. Make permanent and proper repairs to the satisfaction of the attending Class Surveyor and ensure all lifeboats will clear the rail assuming a 15 degree list.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Lifesaving › Launching Appliances › Davit
Issued 18 June 2003 Resolved
Holes wasted in the cross members on davit #14 & 16. Have Class survey all the davits and attest to the structural status as well as the effect of the wasted areas.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Electrical › Electrical Distribution System (service)
Issued 18 June 2003 Resolved
Electrical Distribution Panel on Sun Deck has wood door replacing the original medal door. Replace panel box or return to original state, to the satisfaction of the attending USCG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 June 2003 Resolved
Hotel Managers Office has been modified or added. Originally a technical space with dumb waiter and electrical installations. The space is now a manned office space. Return space to original or have Class re-categorize the space. Fire plans must reflect the final outcome.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
Copy room on Sun deck has been modified. Bulkhead between the Audio room and technical locker has been cut and door has been replaced with a wooden bulkhead. The space is now a manned office space. Return space to original or have Class re-categorize the space. Fire plans must reflect the final LEGACY COMPONENT DESC: Accommodation Space Protection
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2003
Resolved 23 June 2003
Resolution: Copy room on Sun deck has been modified. Bulkhead between the Audio room and technical locker has been cut and door has been replaced with a wooden bulkhead. The space is now a manned office space. Return space to original or have Class re-categorize t
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
The Tour Guide Reception Desk in main stairway has been closed in with solid wooden shutters. Only open reception desks are allowed in stairways, provide an open security shutter (bars, no wood to be used), remove shutters all together or permanently close off reception desk
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 June 2003 Resolved
Life Jacket locker in main stairway must be emptied and permanently closed to the satisfaction of Class. (PFD's moved, locker not sealed)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Fire Fighting › Means of Escape
Issued 18 June 2003 Resolved
Signage throughout vessel missing. Install proper escape and lifesaving signage in accordance with SOLAS and IMO Resolution a780(18), to the satisfaction of the attending USCG Marine inspector. "You are here" Signs and Deck numbers must be in each landing. LEGACY COMPONENT DESC: Escape Route Signs
Condition: Improper Installation
Due 1 July 2003
Resolved 23 September 2003
Resolution: Cleared on Board
Fire Fighting › Means of Escape › Emergency Lighting
Issued 18 June 2003 Resolved
The compliance of the Low Location Lighting (LLL) is in question. Submit a test report on the present LLL or a replacement proposal to the COPT Miami.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Resolution: (Condition of Class to replace NLT 09/03)
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 18 June 2003 Resolved
All Double-leaf fire screen doors must be fitted with sequencers. Submit a proposal to the COPT Miami on steps to be taken and time line to be followed when correcting this deficiency.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2003
Resolved 23 June 2003
Resolution: COndition class issued to be completed in yard 09/03
Lifesaving › Launching Appliances › Davit
Issued 18 June 2003 Resolved
Class survey of Life Boat Davit found several davits wasted and not serviceable provide repair proposal in accordance with manufacture's recommendations. Repairs must be completed prior to departing port
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Resolution: 1&2 remain out of service 3&4 are tenders not to be used, all other have temp repairs untill yard period where permenant repairs and weight testing will be completed as per Conidtion ocf Class.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 18 June 2003 Resolved
Verification of fire control plans and proper categorizing of spaces. Three decks have been completed with a number of items found incorrect. update plan and have class approve.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
Prove proper operation of all fire screen doors, remote and local controls. Unsatisfactory Test conducted with 41 discrepancies.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
FSD#314 has hole in it, make permanent and proper repair to the satisfaction of class
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
FSD#101 has hole in it, make permanent and proper repair to the satisfaction of class
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
FSD#316 has hole in it, make permanent and proper repair to the satisfaction of class
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Construction/Loadline › Penetrations › Gasket
Issued 18 June 2003 Resolved
Side Shell doors show light while dogged, and not weather tight, make permanent and proper repairs to the satisfaction of class prior to departing the port.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2003
Resolved 24 June 2003
Construction/Loadline › Penetrations
Issued 18 June 2003 Resolved
Side Shell doors not indicated on any panel on the bridge (only two on FSD panel), make repairs to satisfaction of class
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Electrical › Lighting (service)
Issued 18 June 2003 Resolved
Lighting in battery room inoperative and missing, make permanent and proper repairs placing the explosive proof lighting on emergency power. Remove extra/old batteries and provide safety gear in accordance with ILO
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 18 June 2003 Resolved
Batteries missing in battery bank, new batteries installed, provide proof of last test of transitional power witnessed by class, or conduct test in presences of attending USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Resolution: Test by BV and in accordance with SOLAS 74 unamended.
Fire Fighting › Fire Main › Condition
Issued 18 June 2003 Resolved
Prove proper operation of the fire pumps. (Numerous holes found in fire main during inspection on Promenade Deck. Have Class survey, test Fire Main and Fire Pumps throughout vessel in accordance with Class rules, and provide a copy of the report to this office
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Electrical › Electrical Distribution System (emergency) › Cable
Issued 18 June 2003 Resolved
Dead cable running under emergency generator, remove or properly terminate to the satisfaction of the attending USCG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Electrical › Electric Generation Source (emergency) › Generator
Issued 18 June 2003 Resolved
Hose and filter missing from emergency generator, make permanent and proper repair to the satisfaction of attending USCG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 June 2003
Resolution: Canceled, not a poper requirement
Stability › Watertight Integrity
Issued 18 June 2003 Resolved
Prove proper operation of all watertight doors, remote and local controls.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Navigation › Emergency Steering
Issued 18 June 2003 Resolved
Prove proper operation of main and auxiliary steering systems.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 June 2003 Resolved
Prove proper operation of the oily water separating system.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 18 June 2003 Resolved
Prove proper operation of the black water systems (MSD).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Lifesaving › Launching Appliances › Davit
Issued 18 June 2003 Resolved
Prove proper operation of the lifeboats at up to a 15 degree list.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Lifesaving › Launching Appliances › Davit
Issued 18 June 2003 Resolved
Prove crew training of life raft deployment (2 rafts minimum).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Electrical › Electric Generation Source (service) › Generator
Issued 18 June 2003 Resolved
Prove proper operation of at least two main generators.
Action required: 705 - Other - as specified
Resolved 23 June 2003
Resolution: Prove proper operation of at least two main generators.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 June 2003 Resolved
General safety walk-through of main laundry, galleys and photo lab.
Action required: 705 - Other - as specified
Resolved 23 June 2003
Construction/Loadline › Penetrations › Valve Flange
Issued 18 June 2003 Resolved
Sea chest valve bolts wasted, have Class attest to the sea worthiness of chest and all related sea valves internally and provide the Class report to this office
Action required: 705 - Other - as specified
Resolved 23 June 2003
Engineering › Steam System (auxiliary)
Issued 18 June 2003 Resolved
Boiler cascade tank leaking water onto electrical panel below, make proper and permanent repairs to satisfaction of Class.
Action required: 705 - Other - as specified
Resolved 23 June 2003
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 18 June 2003 Resolved
Prove proper operation of smoke detection system.
Action required: 705 - Other - as specified
Resolved 23 June 2003
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 18 June 2003 Resolved
Prove proper operation of sprinkler pumps, section valves and alarms.
Action required: 705 - Other - as specified
Resolved 23 June 2003
Documentation › Certificates/Documents
Issued 18 June 2003 Resolved
Provide Valid Flag Registration Certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 18 June 2003 Resolved
Improper wiring on light fixture in library. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 June 2003
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 18 June 2003 Resolved
Dead end pipe coming through bulkhead into C02/fire damper control room on Promenade Deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 23 June 2003
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 18 June 2003 Resolved
Holes cut in to machinery space from storage space. Make permanent and proper repairs to the satisfaction of class
Action required: 705 - Other - as specified
Resolved 23 June 2003
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
Dressing room now used as storage and audio control room, have class survey, re-categorizes and up-date fire control plans as needed.
Action required: 705 - Other - as specified
Resolved 23 June 2003
Electrical › Electrical Distribution System (service)
Issued 18 June 2003 Resolved
Electrical installation throughout fan room aft on upper deck, wasted and hazardous. Make permanent and proper repairs to the satisfaction of Class Surveyor
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
Lockers on either side of Purser's office have direct access to stairway and must be emptied and sealed, to satisfaction of class.
Action required: 705 - Other - as specified
Resolved 23 June 2003
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
Purser's office has direct access to stairway, empty office and seal or reconfigure to satisfaction of class.
Action required: 705 - Other - as specified
Resolved 23 June 2003
Resolution: Allowed by SOLAS
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 June 2003 Resolved
Infirmary room being used for stowage. Remove all stowage from infirmary rooms prior to departing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Fire Fighting › Combustible Materials
Issued 18 June 2003 Resolved
Large amount of oxygen being stored in infirmary spaces, have class determine for stowage is proper or presents a fire hazard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
Hole cut into bulkhead from medical storage room into machinery space to accommodate air unit. Make permanent and proper repair to satisfaction of class and update fire plan as needed.
Action required: 705 - Other - as specified
Resolved 23 June 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 18 June 2003 Resolved
Air bottle for fire fighting berthing apparatus not proper stowed, make permanent rake for stowage of bottles
Action required: 705 - Other - as specified
Resolved 23 June 2003
Lifesaving
Issued 18 June 2003 Resolved
Extra escape signage to be posted in all dead end corridors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Documentation › Certificates/Documents › International Load Line Exemption Certificate
Issued 18 June 2003 Resolved
Provide valid load line certificate with C1 marking, and amend hull markings to match certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Documentation › Certificates/Documents › Passenger Ship Safety Certificate
Issued 18 June 2003 Resolved
Provide valid Passenger Ship Safety Certificate.
Action required: 705 - Other - as specified
Due 27 February 2024
Resolved 27 February 2024
Resolution: 27FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2009. Vessel crapped in '09. From activity: 1820535
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 18 June 2003 Resolved
Provide certificate for the fixed fire protection in galley.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 18 June 2003 Resolved
Update fire control plan to represent the changes:Fire Control Plans must be displayed throughtout vessel as per SOLAS
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2003
Fire Fighting › Fire Main › Condition
Issued 18 June 2003 Resolved
Make permanent repairs to Fire Main in way of hydrant MC 5 in Generator room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 18 June 2003 Resolved
Make permanent repairs to Main Engine Cooling piping where holed in Main Engine room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Fire Fighting › Means of Escape
Issued 18 June 2003 Resolved
Remove grating from top of emergency escape stairway on A-deck in aft tunnel on starboard side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
All door cleared execept Casino double door, the stbd one is to remain closed untill repaired, port is repair, but will need to be replaced asap. must be complete operational by July 01
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 23 September 2003
Resolution: Cleared on board, CHK
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
Bulkheads in photo lab have been cut out to accomadate air conditioning. A-0 boundary must be maintianed. Make permanent and proper repairs to the satisfaction of Class prior to using the Photo lab. Temp repairs completed, permanent repairs by July 01, 2003
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 23 September 2003
Resolution: Cleared on board, CHK
Documentation › Safety/Response Plans/Programs
Issued 18 June 2003 Resolved
Class to provide condition on the following items; LLL, Sea Chest Valves, Fire Screen Doors, Davits.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Resolution: Conditions of class issued to be cleared at the next yard period.
Fire Fighting › Structural Fire Protection - General
Issued 18 June 2003 Resolved
Remove locks from fire screen doors
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Electrical › Lighting (service)
Issued 13 March 2003 Resolved
Replace broken/missing covers on light fixture/appliances in engineering spaces. LEGACY COMPONENT DESC: Covers
Condition: Improper/Lack of Maintenance
Due 13 April 2003
Resolved 23 June 2003
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 4 December 2002 Resolved
Address ship's inability to reverse the direction of thrust of the propeller while moving ahead at speeds greater than 5 Kts and provide class report attesting to the satisfactory completion of repairs.
Action required: 705 - Other - as specified
Resolved 6 December 2002
Resolution: Received class letter stating compliance with Solas 60 II/28.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 4 December 2002 Resolved
Provide a copy of the report submitted to the company stating the ship was experiencing problems with bow thrusters and astern propulsion, as required by its SMS. In addition provide a copy of the procedures for the implementation of corrective action.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2002
Resolution: Report was unnecessary since astern propulsion problem was due to machinery limitations.
Electrical
Issued 4 December 2002 Resolved
Address electrical problems involved with bow thrusters and provide class report attesting to the satisfactory operation of both bow thrusters or an acceptable alternative.
Action required: 705 - Other - as specified
Resolved 6 December 2002
Resolution: Class report indicated both bow thrusters were fully operational.
Construction/Loadline › Structures › Deck Plating
Issued 12 October 2002 Resolved
Hole in deck betwiin crew galley and general galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2002
Resolved 13 October 2002
Fire Fighting › Structural Fire Protection - General
Issued 12 October 2002 Resolved
Update fire control plan to show arrangements around crew galley.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 7 January 2003
Construction/Loadline › Penetrations
Issued 12 October 2002 Resolved
Cabin M61 hole in A60 bulkhead broken vent duck and back of wood not treated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 12 October 2002
Construction/Loadline › Penetrations
Issued 12 October 2002 Resolved
Petty messw A60 deck hole.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 12 October 2002
Electrical › Electric Generation Source (service) › Generator Cable
Issued 12 October 2002 Resolved
main galley wire insulation worn off, wire laying in water on deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 12 October 2002
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 12 October 2002 Resolved
FD 518 vestibule missing moke detector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 12 October 2002
Fire Fighting › Miscellaneous Items
Issued 12 October 2002 Resolved
Provide access around main galley to verify structural fire protection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 12 October 2002
Engineering › Generator (propulsion-electric)
Issued 1 October 2002 Resolved
loose fuel return line to tank on emergency generator.
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 1 October 2002
Resolution: Corrected during def check conducted by MSO Portland, ME.
Engineering › Fuel Oil Service System
Issued 1 October 2002 Resolved
leaking manhole cover on emergency generator man hole cover LEGACY COMPONENT DESC: Tank
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 1 October 2002
Resolution: Leak repaired, no longer leaking.
Construction/Loadline › Structures
Issued 1 October 2002 Resolved
wasted/holed overhead in emergency gen room LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Due 3 October 2002
Resolved 1 October 2002
Resolution: Class cleared, CG witnessed inserts.
Engineering › Fuel Oil Service System
Issued 1 October 2002 Resolved
missing fuel tank level gauge on emergency gen fuel tank LEGACY COMPONENT DESC: Tank
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 4 October 2002
Resolution: Verified as permanently corrected during exam by attending marine inspector.
Construction/Loadline › Structures
Issued 1 October 2002 Resolved
wasted/holed vents on vents on funnel deck LEGACY COMPONENT DESC: Ventilators
Condition: Improper/Lack of Maintenance
Due 26 October 2002
Resolved 29 October 2002
Resolution: Class/CG witnessed and cleared repairs made to holed vents on funnel deck.
Lifesaving › Buoyant Apparatus
Issued 1 October 2002 Resolved
wasted lifelines on life floats
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 1 October 2002
Resolution: Witnessed newly installed lifelines on life floats.
Construction/Loadline › Structures
Issued 1 October 2002 Resolved
wasted/cracked weld on radar dome deck mount
Condition: Improper/Lack of Maintenance
Due 1 October 2002
Resolved 1 October 2002
Electrical › Lighting (service)
Issued 1 October 2002 Resolved
electrical box on funnel deck for signs adrift with loose wiring LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 1 October 2002
Resolved 1 October 2002
Resolution: Loose wiring removed and box was properly installed on blkd.
Engineering › Fuel Oil Service System › Piping
Issued 1 October 2002 Resolved
wasted fuel supply line for emergency generator
Condition: Improper/Lack of Maintenance
Due 1 October 2002
Resolved 1 October 2002
Engineering › Lubricating Oil Service System
Issued 1 October 2002 Resolved
heavy oil leak #2 MDE,inboard side. Funnel systems were put in place to drain to a 5 gallon bucket
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 8 October 2002
Resolution: Satisfactory class report (Bureau Veritas) recieved attesting to permanent and satisfactory repairs accomplished on October 7, 2002.
Electrical › Electric Supply System (service)
Issued 1 October 2002 Resolved
remove unauthorized wiring and outlets in battery room
Condition: Improper Installation
Due 1 October 2002
Resolved 1 October 2002
Construction/Loadline › Structures
Issued 1 October 2002 Resolved
holed bulkhead between battery room and emergency gen room LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 1 October 2002
Resolution: Class/CG witnessed inserts made.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 1 October 2002 Resolved
wasted/holed sewage line at tank in boiler space
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 1 October 2002
Resolution: Perm. repairs made to wasted/holed sewage line.
Construction/Loadline › Structures
Issued 1 October 2002 Resolved
wasted/holed deck on freezer deck LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 1 October 2002
Resolution: Class/CG witnessed repairs.
Fire Fighting › Structural - A Class Divisions
Issued 1 October 2002 Resolved
holes beneath fire door#209
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 1 October 2002
Resolution: Holes properly prepared beneath FD #209.
Electrical › Lighting (emergency)
Issued 1 October 2002 Resolved
missing emergency lighting on freezer deck LEGACY COMPONENT DESC: Lighting Fixture
Condition: Design Flaw
Due 3 October 2002
Resolved 1 October 2002
Resolution: Emergency light installed outside freezer.
Construction/Loadline › Structures
Issued 1 October 2002 Resolved
holed A-0 bulkhead in crew mess room LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper Installation
Due 3 October 2002
Resolved 1 October 2002
Resolution: Class/CG verified that A-0 blkd penetration repaired.
Construction/Loadline › Structures
Issued 1 October 2002 Resolved
holed deck at a-0 bulkhead in crew mess room LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 1 October 2002
Resolution: Class/CG witnessed that pipe open pipe was closed behind blkd in mess room.
Engineering › Generator (propulsion-electric)
Issued 1 October 2002 Resolved
repair #1 generator to satisfaction of class LEGACY COMPONENT DESC: Coil
Condition: Unknown
Due 23 October 2002
Resolved 8 October 2002
Resolution: Class report (Bureau Veritas) recieved attesting to permanent repairs completed on 07 October 2002
Fire Fighting › Structural - A Class Divisions
Issued 1 October 2002 Resolved
missing fire insulation at A-0 bulkhead in mess room LEGACY COMPONENT DESC: Bulkheads - Accommodation Spaces
Condition: Improper Installation
Due 3 October 2002
Resolved 1 October 2002
Resolution: Witnessed insulation installed at A-0 blkd in cre mess rm.
Fire Fighting › Automatic Sprinkler System
Issued 29 September 2002 Resolved
Sprinkler stations 2, 3, 6, and 13 when tested by dropping the pressure at each individual station, failed to energize the main sprinkler pump in the e/r as required and did not give an alarm indication on the bridge. LEGACY COMPONENT DESC: Sprinklers
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2002
Resolved 29 September 2002
Resolution: Crew determined that air was introduced into the closed sprinkler system while doing routine maint. on sprinkler stations 3 & 24 on 27SEP02. The air was bled out of the system at the highest level & all 4 sprinkler stations were tested again, sat.
Lifesaving › Lifeboat
Issued 29 September 2002 Resolved
Starboard lifeboat #5's secondary rudder post used to keep the rudder alligned was wasted through. Main rudder post, sat. No degredation of steering capability of lifeboat. LEGACY COMPONENT DESC: Rudder/Tiller/Steering
Condition: Improper/Lack of Maintenance
Due 6 October 2002
Resolved 4 October 2002
Resolution: Verified as permanently corrected during exam by attending marine inspector.
Accommodation/Occupational Safety › Occupational Safety
Issued 12 September 2002 Resolved
Missing section of emergency escape ladder by aft stbd settling tank. LEGACY COMPONENT DESC: Hand Grab
Condition: Unknown
Due 12 September 2002
Resolved 12 September 2002
Engineering › Shafting/Propeller Arrangements
Issued 12 September 2002 Resolved
Missing retaining stud on stbd shaft packing LEGACY COMPONENT DESC: Bearing
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2002
Resolved 12 September 2002
Engineering › Fuel Oil Service System
Issued 12 September 2002 Resolved
Heavy diesel fuel leak on #3 generator fuel filter assembly LEGACY COMPONENT DESC: Filter
Condition: Unknown
Due 12 September 2002
Resolved 12 September 2002
Communications › Alarms/Indicators
Issued 12 September 2002 Resolved
Alarms for watertight doors not working properly (breaker #17 on bridge electrical panel tripping)
Condition: Unknown
Due 18 September 2002
Resolved 20 September 2002
Resolution: Witnessed proper operation during deficiency follow-up exam this date of all wt doors and associated alarms.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 12 September 2002 Resolved
Raw sewage flowing into engine room bilge. LEGACY COMPONENT DESC: Toilet
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2002
Resolved 12 September 2002
Lifesaving › Lifeboat
Issued 12 September 2002 Resolved
Renew as original drain plugs on life boats 8, 10, and 14. LEGACY COMPONENT DESC: Drain Valve
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 12 October 2002
Resolved 12 September 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 12 September 2002 Resolved
Accomodation space on main deck being used for oil drum storage and door is being closed by plywood.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 29 September 2002
Resolved 20 September 2002
Resolution: Items have been removed (witnessed this date during DefCheck) , signage posted and class survyeyor in attendance attesting to space not suited for stowage of flammable materials.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 12 September 2002 Resolved
missing dryer vent door for crews dryer.
Condition: Unknown
Due 18 September 2002
Resolved 26 September 2002
Fire Fighting › Structural Fire Protection - General
Issued 12 September 2002 Resolved
missing fire insulation in overhead of plumbers workshop LEGACY COMPONENT DESC: Accommodation Space Protection
Condition: Unknown
Due 29 September 2002
Resolved 20 September 2002
Resolution: Proper fire rated insulation permanently installed in overhead of this space, class surveyor on board and present to verify and attest to proper material and installtion methods used.
Fire Fighting › Structural - A Class Divisions › Corridors
Issued 12 September 2002 Resolved
fire door 424 not tight
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Fire Fighting › Structural - A Class Divisions
Issued 12 September 2002 Resolved
bulkhead in E/R comprimised by sprinkler line LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Condition: Improper Installation
Due 29 September 2002
Resolved 29 September 2002
Resolution: E/R blkd repaired, no longer compromised.
Construction/Loadline › Structures
Issued 12 September 2002 Resolved
3x5" hole thru main deck above STBD heavy oil tank aft LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Due 29 September 2002
Resolved 29 September 2002
Resolution: Class approved insert in FO tank verified by CG.
Engineering › Fuel Oil Service System
Issued 12 September 2002 Resolved
hydrotest all fuel oil lines near aft stbd heavy oil tank due to several unknown leaks LEGACY COMPONENT DESC: Piping
Due 29 September 2002
Resolved 29 September 2002
Resolution: Class surveyor in attendance during CVQ addressed this deficiency with Portland and attending NY marine inspector stating that the pipelines in question were in fact vent lines and not able to be hydro tested.
Construction/Loadline › Structures › Deck Plating
Issued 12 September 2002 Resolved
holed and wasted steel deck in brine room( refer flat)
Condition: Improper Installation
Due 12 September 2002
Resolved 12 September 2002
Resolution: corrected and attested to by class
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 12 September 2002 Resolved
leaking oil at manhole cover to stbd fuel settling tank
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Resolution: corrected to satisfaction of class
Engineering › Bilge Water Management System
Issued 12 September 2002 Resolved
wasted bilge overboard 14" line at port shaft LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 29 September 2002
Resolved 29 September 2002
Resolution: Repaired wasted sections of bilge piping.
Engineering › Gasoline Engine (auxiliary)
Issued 12 September 2002 Resolved
oil leaks noted on 1@ 2 main engine oil cooler's
Condition: Improper/Lack of Maintenance
Due 29 September 2002
Resolved 29 September 2002
Resolution: Corrected, no longer leaking.
Fire Fighting › Structural - B Class Divisions
Issued 12 September 2002 Resolved
missing fire insulation at stbd shaft bulkhead LEGACY COMPONENT DESC: Bulkheads - Aux Spaces (moderate fire risk)
Condition: Improper Installation
Due 29 September 2002
Resolved 29 September 2002
Resolution: Witnessed fire insulation installed at stbd shaft blkd.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 12 September 2002 Resolved
leaking oil at manhole cover to oil tank, aft oil settling tanks
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Construction/Loadline › Hull
Issued 12 September 2002 Resolved
hull gauging required above both shafts LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Due 18 October 2002
Resolved 13 November 2002
Resolution: Received class report attesting to gauging of aft peak tank bottom plating above port and starboard tailshafts. The plating was found to be within acceptable limits.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 12 September 2002 Resolved
excessive leaking at both shaft seals
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Fire Fighting › Structural - A Class Divisions
Issued 12 September 2002 Resolved
hydraulic leak at WTD #3 LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 29 September 2002
Resolved 29 September 2002
Resolution: WTD #3 no longer leaking hydrailic oil.
Engineering › Lubricating Oil Service System › Flange
Issued 12 September 2002 Resolved
oil leak in port stabilizer room
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Fire Fighting › Fire Main › Condition
Issued 12 September 2002 Resolved
fire pump overboard piping in port stabiler room is leaking
Condition: Improper/Lack of Maintenance
Due 29 September 2002
Resolved 29 September 2002
Construction/Loadline › Structures › Deck Plating
Issued 12 September 2002 Resolved
hole in overhead of E/R on stbd side FWD
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Resolution: corrected to satisfaction of class
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 September 2002 Resolved
holed pipe incooling water supply piping,under deck plates fwd port side.
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Resolution: to satisfaction of class
Fire Fighting › Combustible Materials
Issued 12 September 2002 Resolved
F/O in bilges of stbd fuel room
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 12 September 2002 Resolved
leaking oil from sludge tank manhole cover in stbd stabiler room LEGACY COMPONENT DESC: Flange
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Fire Fighting › Fire Hoses › Condition
Issued 12 September 2002 Resolved
test fire hoses in E/R
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Deck/Cargo › Ballast › Dedicated Clean Ballast Tanks
Issued 12 September 2002 Resolved
STBD FWD ballast tank manhole cover leaking
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Construction/Loadline › Structures › End Bulkhead
Issued 12 September 2002 Resolved
several holes in W/T bulkhead fwd storage room
Condition: Placed in Improper Service
Due 12 September 2002
Resolved 12 September 2002
Accommodation/Occupational Safety › Messroom
Issued 12 September 2002 Resolved
drain from galley is holed by firedoor 314
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Construction/Loadline › Structures › Trunk
Issued 12 September 2002 Resolved
man hole to pipe chase in fwd between deck passageway is loose
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 12 September 2002
Fire Fighting › Structural - A Class Divisions
Issued 12 September 2002 Resolved
fire door 514 wont close tight LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 26 September 2002
Resolved 26 September 2002
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 12 September 2002 Resolved
echo depth sounder not operable. Vessel failed to notify. Leter of warning issued
Condition: Unknown
Due 12 September 2002
Resolved 12 September 2002
Operations/Management › Streamlined Inspection Program
Issued 12 September 2002 Resolved
vessel conducted hotwork without hotwork permit IAW company safety & environmental protection policy(ops manual)
Condition: Unknown
Due 18 September 2002
Resolved 12 September 2002
Engineering › Diesel Engine (auxiliary)
Issued 12 September 2002 Resolved
fuel and oil leaks on both main engines
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 4 October 2002
Resolution: Veridfied as gotten under control during exam by attending marine inspector.
Engineering › Bilge Water Management System
Issued 12 September 2002 Resolved
bilge manifold reach rods are disconnectedat fwd bulkhead and sewage treatment room LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 19 September 2002
Resolved 26 September 2002
Operations/Management › Streamlined Inspection Program
Issued 12 September 2002 Resolved
operate & maintain MSD IAW OPS manual
Condition: Unknown
Due 18 September 2002
Resolved 26 September 2002
Communications › Radio Communications
Issued 28 June 2002 Resolved
Insufficient number of portable VHF radios on hand for use for emergency communications between life boat crews, emergency muster parties and command anc control stations. Procure at least 20 additinal units and fax recieving report to COTP NY to show reciept of same. LEGACY COMPONENT DESC: Emergency Portable Radios
Action required: 705 - Other - as specified
Due 28 July 2002
Resolved 21 July 2002
Resolution: Verified that additional portable VHF radios were recieved and placed in use on board vessel as required at the previous exam by the attending Marine Inspector.
Lifesaving › Lifejacket/PFD (General)
Issued 28 April 2002 Resolved
Passenger cabin lifejacket donning instruction placards are unsat for the style of jacket stowed in passenger cabiins. Provide appropriate donning placards in all passenger cabins and at emergency/muster and embarkation stations which reflect the style of jacket in service and clear instructions. LEGACY COMPONENT DESC: Storage
Condition: Unknown
Due 9 June 2002
Resolved 9 June 2002
Resolution: ALL PASSENGER CABIN LIFEJACKET DONNING INSTRUCTION PLACARDS HAVE BEEN REPLACED TO REFLECT THE STYLE OF JACKETS THAT ARE IN SERVICE.
Electrical › Electrical Distribution System (emergency)
Issued 17 March 2002 Resolved
Blank off breakers (missing) in breaker panel P3 fan room aft bulkhead to the satisfaction of class. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified that braker was blank.
Electrical › Electric Generation Source (service)
Issued 17 March 2002 Resolved
Replace outlet w/marine grade and properly secure to bulkhead in main deck fan room frame 75 to the satisfaction of class. LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified installation of a marine grade outlet.
Electrical › Electric Generation Source (service)
Issued 17 March 2002 Resolved
Fix broken electrical outlet in B deck just forward of cabin 107. LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified outlet.
Pollution Prevention/Response › Prevention Equipment
Issued 17 March 2002 Resolved
Bolt down manhole cover of sewage tank in after steering. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified man cover to sewer tank was bolt down.
Pollution Prevention/Response › Prevention Equipment
Issued 17 March 2002 Resolved
Secure all openings in gray water tank aft of purifier flat.
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified all opening on gray water tank were secured.
Fire Fighting › Structural - A Class Divisions
Issued 17 March 2002 Resolved
Replace missing insulation in the following spaces to the satisfaction of class: deck/safety office above entry, FSD808 forward port side, Mermaid Lounge in fake cieling around frame, above FSD 705 & 706 and in electrical locker near FSD 436.
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Insullation was replaced.
Fire Fighting › Miscellaneous Items
Issued 17 March 2002 Resolved
Ensure fire control plan is updated and reflects insulation and location of La Trattoria, Children's room and fire doors to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Vessel representative showed new and updated fire control plan.
Fire Fighting › Structural - A Class Divisions
Issued 17 March 2002 Resolved
Clean engine room casino emergency egress to the emergency generator room. LEGACY COMPONENT DESC: Bulkheads - External Escape Routes
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Engine casing was cleaned.
Fire Fighting › Automatic Sprinkler System
Issued 17 March 2002 Resolved
Replace sprinkler head in room aft of aft women's head on P-deck port side to the satisfaction of class. LEGACY COMPONENT DESC: Sprinklers
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified sprinkler head.
Fire Fighting › Fixed Fire Detection System
Issued 17 March 2002 Resolved
Remove paint from sensor sprinkler bulbs and replace empty bulbs throughout vessel to the satisfaction of class. LEGACY COMPONENT DESC: Heat Detectors
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified that paint was removed from all sprinkler heads.
Fire Fighting › Fixed Fire Detection System
Issued 17 March 2002 Resolved
Identify smoke detectors in ceilings and mark in forward part of U deck to the satisfaction of class. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Placed in Improper Service
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified marking in smoke detectors.
Fire Fighting › Structural Fire Protection - General
Issued 17 March 2002 Resolved
Prove presence of draft stops in Grand Lounge in accordance with fire control plan to the satisfaction of class.
Condition: Unknown
Due 17 April 2002
Resolved 2 April 2002
Resolution: Cleared item following receipt of faxed info from BV class surveyor [name withheld] referencing a fax from Nautical Design, Inc indicating Grand Lounge ceiling is considered an open ceiling and draft stops are not required. Discussed with [name withheld] at MSC.
Fire Fighting › Structural Fire Protection - General
Issued 17 March 2002 Resolved
Ensure all draft stops connect with upper deck and proper bulkheads (w/no cut openings unless authorized) between U16 & U20, and in casino to the satisfaction of class.
Condition: Unknown
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified draft stops. They were installed in accordance to class.
Fire Fighting › Structural - A Class Divisions
Issued 17 March 2002 Resolved
Repair/correct the following issues with fire doors to the satisfaction of class: #709 length of throw (does not fully catch), #615 auto shut switch inoperable, #614 latch inoperable, #508 latch inoperable, and #520 hole in door beow handle. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified operation of auto shut swith and latch.
Fire Fighting › Structural - A Class Divisions
Issued 17 March 2002 Resolved
Ensure proper seal of bulkheads above FSD 503 & 504 and in disco next to bar aft end to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified that bulkheads were properly seal and in accordance to class.
Accommodation/Occupational Safety
Issued 17 March 2002 Resolved
Replace missing light cover in passage way beside U96.
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified light cover
Lifesaving › Embarkation Appliances/Stations
Issued 17 March 2002 Resolved
Ensure down arrow sign indicator is replaced on stairwell aft of internet cafe to disco to the satisfaction of class. LEGACY COMPONENT DESC: Designated Location
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 14 April 2002
Resolution: Verified arrow sign indicator on stairwell
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 5 March 2002 Resolved
Port engine cylinder A1 camshaft lobe worn and scarred. Repair to satisfaction of class. LEGACY COMPONENT DESC: Camshaft
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2002
Resolved 8 March 2002
Resolution: Received sat class report.
Engineering › Reduction Gearing/Clutches
Issued 5 March 2002 Resolved
Starboard gear box "son-input" bearing locked up and caused lube oil failure. Vessel personnel removed non-essential system many years ago, and bearing is non-essential to satisfacotry engine/gear box oepration. Repair to satisfaction of class. LEGACY COMPONENT DESC: Bearing
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2002
Resolved 8 March 2002
Resolution: Received sat class report.
Documentation
Issued 5 March 2002 Resolved
Provided class report addressing engineering casualties and attest to satisfactory repair.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2002
Resolved 8 March 2002
Resolution: Received sat class report.
Lifesaving › Launching Appliances
Issued 16 February 2002 Resolved
Provide class report for permanent repairs to STBD launch port side chine and port rub rail.
Condition: Unknown
Due 22 March 2002
Resolved 17 March 2002
Electrical › Lighting (service)
Issued 16 February 2002 Resolved
Provide class report for repairs/renewal of exterior main deck lighting fixture housing. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 22 March 2002
Resolved 17 March 2002
Stability › Watertight Integrity
Issued 16 February 2002 Resolved
Make forward superstructure bulkhead watertight for forward fan room main deck U-1. LEGACY COMPONENT DESC: bulkhead
Condition: Improper/Lack of Maintenance
Due 22 March 2002
Resolved 17 March 2002
Construction/Loadline › Hull
Issued 16 February 2002 Resolved
Provide class report addressing condition of wasted frames AFT shaft alley. LEGACY COMPONENT DESC: Transverse Frame
Condition: Improper/Lack of Maintenance
Due 22 March 2002
Resolved 17 March 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 16 February 2002 Resolved
Make permanent repairs to port aft sewage vaccum tank (now leaking into shaft alley.) Tank is to be isolated and not use until repaired. LEGACY COMPONENT DESC: Sewage Vaccum
Condition: Unknown
Due 22 March 2002
Resolved 17 March 2002
Operations/Management › Pollution
Issued 16 February 2002 Resolved
Clean hydraulic fluid off overhead and cable runs of port fin stabilizer room. LEGACY COMPONENT DESC: Control of Discharge of Oil
Condition: Unknown
Due 22 March 2002
Resolved 17 March 2002
Engineering › Sea-water System (primary cooling)
Issued 16 February 2002 Resolved
Make permanent repairs to leaking saltwater cooling piping. Port aft stabilizer room. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 22 March 2002
Resolved 17 March 2002
Resolution: Cleared.
Construction/Loadline › Hull
Issued 16 February 2002 Resolved
Free-up all deck rates in all machinery spaces. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Due 22 March 2002
Resolved 17 March 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 February 2002 Resolved
Make permanent repair to leaking jacket water piping outboard port engine between #3 & #4 cylinder MDE. LEGACY COMPONENT DESC: Water Jacket Piping
Condition: Improper/Lack of Maintenance
Due 22 March 2002
Resolved 17 March 2002
Resolution: Cleared.
Fire Fighting › Structural Fire Protection - General
Issued 16 February 2002 Resolved
Clean excessive oil off bulkheads and hull between #27 Fuel oil tank and water tight bulkhead. Make permanent repairs to leaking manhole cover #27 fuel oil tank. LEGACY COMPONENT DESC: Structural Bulkhead Construction
Condition: Improper/Lack of Maintenance
Due 22 March 2002
Resolved 17 March 2002
Fire Fighting › Structural - A Class Divisions
Issued 16 February 2002 Resolved
Replaced missing 4x4 section of insulation STBD overhead FWD shat alley (IWO Stores.) LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Condition: Improper/Lack of Maintenance
Due 22 March 2002
Resolved 17 March 2002
Stability › Watertight Integrity
Issued 16 February 2002 Resolved
Clean and provide gaugings of AFT end boiler room blkhd top of FOT. #50. LEGACY COMPONENT DESC: Water tight bulkhead
Condition: Unknown
Due 22 February 2002
Resolved 17 March 2002
Stability › Watertight Integrity
Issued 16 February 2002 Resolved
Make permanent repair to 12"x6" opening in aft blkhd of boiler room #12. Temporary repairs were performed prior to departure. LEGACY COMPONENT DESC: Bulkhead
Condition: Unknown
Due 22 March 2002
Resolved 17 March 2002
Engineering
Issued 16 February 2002 Resolved
Provide class report listing all temporary repairs to all machinery space piping stating their approval and permanent repair schedule. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 22 March 2002
Resolved 17 March 2002
Resolution: Cleared.
Engineering › Shafting/Propeller Arrangements
Issued 11 February 2002 Resolved
Port and Starboard shaft packing leaking approximately 1 GPM Port and 1.5 GPM Starboard. Reduce leakage to an acceptable level. Class to approve this arrangement. LEGACY COMPONENT DESC: Stern Gland
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 12 February 2002
Resolution: Cleared with class report.
Engineering › Shafting/Propeller Arrangements
Issued 11 February 2002 Resolved
Port and Starboard after most shaft bearings have bearing cooling arrangments that are in various states of disarray. Furthermore, the Port bearing oil contaminated with water and the Starboard bearing cooling hose is disconnected and draining directly to the bilge. Class to attest to arrangement. LEGACY COMPONENT DESC: Bearing
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 12 February 2002
Resolution: Cleared with class report.
Engineering › Bilge Water Management System
Issued 11 February 2002 Resolved
Shaft space bilges filled with excessive water and oil. Vessel to remove all water and oil in these bilges properly. Vessel removed 12000 gallons of water/oil from bilges and storage tank to shore side reception facility. Class issued requirement to chemically clean bilges by 16FEB02.
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 14 April 2002
Resolution: Verified bilges have been pumped and chemical cleaned.
Pollution Prevention/Response
Issued 11 February 2002 Resolved
Sanitary line valve DCV#6 wasted and leaking into machine shop. Repair to the satisfaction of class. Valve temporarily patched to satisfaction of class and is to be permanently repaired at a later date. LEGACY COMPONENT DESC: Sanitary Piping Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 12 February 2002
Resolution: Line was replaced.
Construction/Loadline
Issued 11 February 2002 Resolved
Machine shop deck by way of Starboard forward deck wasted through. Repair to the satisfaction of class. Class issued recommendation to repair within two months. LEGACY COMPONENT DESC: Deck, Machine Shop
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 12 February 2002
Engineering › Bilge Water Management System
Issued 11 February 2002 Resolved
Main engine lube oil purifier space bilges have excessive oil and water. Remove all oil and water from bilges. Oil and water removed. Bilges to be chemically cleaned by 16 FEB 02 and inspected by class surveyor. LEGACY COMPONENT DESC: Purifier bilges
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 12 February 2002
Construction/Loadline › Hull
Issued 11 February 2002 Resolved
Rivets located Port side forward Tunnel space by way of small sewage tank wasted. Class to attest to the integrity of these rivets. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 12 February 2002
Resolution: Rivets were welded on outside at the last drydock.
Construction/Loadline
Issued 5 October 2001 Resolved
PROVIDE CLASS REPORT OF CONDITION OF ALL HULL RIVETS
Condition: Unknown
Due 15 November 2001
Resolved 11 February 2002
Resolution: Cleared with drydock survey from Bureau Veritas.
Lifesaving
Issued 5 October 2001 Resolved
REMOVE EXCESSIVE FUEL OIL FROM FUEL OIL TREATMENT ROOM BILGES
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Construction/Loadline
Issued 5 October 2001 Resolved
RENEW/REPAIR WEEPING HULL RIVETS IN ENGINEER STORAGE ROOM
Condition: Unknown
Due 15 November 2001
Resolved 11 February 2002
Resolution: Cleared with drydock survey from Bureau Veritas.
Engineering
Issued 5 October 2001 Resolved
RENEW LEAKING LINE SHAFT BEARING OIL SEALS._x001C_ _x001C_
Condition: Unknown
Due 15 November 2001
Resolved 11 February 2002
Construction/Loadline
Issued 5 October 2001 Resolved
RENEW AND MAKE TIGHT PIPE PENETRATIONS THROUGH WATERTIGHT BULKHEAD IN STARBOARD SHAFT ALLEY
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Engineering
Issued 5 October 2001 Resolved
RENEW LEAKING FUEL OIL PIPE IN FUEL OIL TREATMENT ROOM._x001C_ _x001C_ PIPE RENEWED
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Engineering
Issued 5 October 2001 Resolved
REPAIR LEAKING FUEL OIL BOOSTER PUMPS IN FUEL OIL TREATMENT ROOM
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Fire Fighting
Issued 5 October 2001 Resolved
REPAIR NUMEROUS FIRE DOORS THAT DON'T CLOSE PROPERLY
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Fire Fighting
Issued 5 October 2001 Resolved
PROVIDE KEY FOR EMERGENCY DOOR BY FIRE DAMPER 48
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Lifesaving
Issued 5 October 2001 Resolved
REMOVE OPEN PAINT CANS FROM ENGINE ROOM STORES
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Construction/Loadline
Issued 5 October 2001 Resolved
REPAIR BILGE MANIFOLD REMOTE OPERATOR IN FORWARD ENGINE ROOM/BOILER ROOM
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Fire Fighting
Issued 5 October 2001 Resolved
CONDUCT SATISFACTORY FIRE DRILL. _x001C_ INEFFECTIVE COMMUNICATIONS, INADEQUATE CREW KNOWLEDGE, DEFECTIVE SAFETY GEAR. AIR PACKS NOT PROPERLY DONNED_x001C_ EMPTY AIR BOTTLES USED, DEFECTIVE AIR REGULATORS USED
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Fire Fighting
Issued 5 October 2001 Resolved
REPAIR FIRE DETECTION PANEL _x001C__x001C_ 2 SENSORS AND 2 HEADS RENEWED
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Accommodation/Occupational Safety
Issued 5 October 2001 Resolved
RENEW WASTED SEWAGE PIPING IN ALL ENGINEERING SPACES_x001C_ _x001C_ NUMEROUS PIPING DETERIORATED
Condition: Unknown
Due 15 November 2001
Resolved 11 February 2002
Engineering
Issued 5 October 2001 Resolved
REPAIR LEAKING STERN TUBE SHAFT PACKING_x001C_ _x001C_ RING OF PACKING ADDED, SLOWED LEAKAGE ENOUGH TO ALLOW VESSEL TO SAIL
Condition: Unknown
Due 15 November 2001
Resolved 11 February 2002
Resolution: Cleared with drydock survey from Bureau Veritas. New packing added.
Construction/Loadline
Issued 5 October 2001 Resolved
SIDE LOADING DOOR STARBOARD SIDE NOT WATERTIGHT
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Lifesaving
Issued 5 October 2001 Resolved
PORT SIDE AFT LIFE RAFT HYDROSTATIC RELEASE HOOKS BENT AND INOPERABLE
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Lifesaving
Issued 5 October 2001 Resolved
LIFE RAFT HAMMER RELEASES NOT DATED
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Construction/Loadline
Issued 5 October 2001 Resolved
MAIN DECK FORWARD ESCAPE DOOR STARBOARD SIDE NOT WATERTIGHT
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Electrical
Issued 5 October 2001 Resolved
DEADED WIRES THROUGH OUT CREW AND MAINTENANCE AREAS
Condition: Unknown
Due 15 November 2001
Resolved 11 February 2002
Documentation
Issued 5 October 2001 Resolved
ISM SYSTEM DEEMED INEFFECTIVE, EXTERNAL AUDIT TO BE CONDUCTED
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Engineering
Issued 5 October 2001 Resolved
REPAIR/RENEW LEAKING MAIN ENGINE EXHAUST WASTE HEAT EXCHANGERS _x001C_ _x001C_ LEAKING SANITARY PIPE LEAKING THROUGH MAIN ENGINE EXHAUST
Condition: Unknown
Due 15 November 2001
Resolved 11 February 2002
Lifesaving
Issued 5 October 2001 Resolved
RENEW/REPAIR WASTED GALLEY STEAM CONDENSOR LOCATED IN ENGINE ROOM
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Fire Fighting
Issued 5 October 2001 Resolved
REPAIR ALL AREAS WHERE STRUCTURAL FIRE PROTECTION DECKS AND OVERHEADS HAVE BEEN COMPROMISED. BY F/D 514,423,310,214,311,433,430,317,16 BY WTD 15, IN CO2 ROOM._x001C_ BULKHEADS AND DECKS COMPROMISED WHERE PIPING INSTALL/REPAIRS CONDUCTED.
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Engineering
Issued 5 October 2001 Resolved
RENEW LEAKING BUNKER OIL PIPING IN LAUNDRY
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Engineering
Issued 22 March 2001 Resolved
FIXE LUBE OIL LEAK ON PORT SIDE LUBE OIL COOLER.
Condition: Unknown
Due 22 April 2001
Resolved 13 April 2001
Lifesaving
Issued 22 March 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 April 2001
Resolved 7 April 2001
Fire Fighting
Issued 22 March 2001 Resolved
MAKE PERMANENT REPAIRS ON HOLE AND SOFT PATCHES ON FIRE MAIN SYSTEM AT NEXTDRYDOCK.
Condition: Unknown
Due 7 April 2001
Resolved 7 April 2001
Construction/Loadline
Issued 22 March 2001 Resolved
REPAIR LOCAL CONTROL FOR OPERATION FOR WATERTIGHT DOOR #16.
Condition: Unknown
Due 7 April 2001
Resolved 7 April 2001
Lifesaving
Issued 22 March 2001 Resolved
PLUG OR PROPERLY CLOSE HOLE IWO WIRE GOING THROUGH DAMPER STOP ABOVE ROOM M25.
Condition: Unknown
Due 7 April 2001
Resolved 7 April 2001
Unknown
Issued 18 January 2001 Resolved
PROVIDE DETAILED INFORMATION ON KONICA PHOTO PROCESSOR CHEMICAL DISCHARGE THAT LEADS TO OVERBOARD PIPING. INCLUDE BIODEGRADABILITY AND WHERE EFFLUENT GOES.
Condition: Unknown
Due 26 February 2001
Resolved 26 February 2001
Lifesaving
Issued 18 January 2001 Resolved
REPLACE ALL LIFEJACKET LIGHTS PRIOR TO THEIR EXPIRATION AT THE END OF JANUARY 2001.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Lifesaving
Issued 18 January 2001 Resolved
PROVIDE VIDEO TAPE TO US COAST GUARD INSPECTORS DISPLAYING THE LOWERING OF LIFEBOATS. DRILL COULD NOT BE COMPLETED DUE TO BUNKERING BARGE ALONGSIDE.
Condition: Unknown
Due 18 February 2001
Resolved 26 February 2001
Fire Fighting
Issued 29 September 2000 Resolved
Vessel has a laundry shoot the runs down several decks to the laundry room with no dampers or SFP. Shoot to be fitted with proper SFP or be proper removed at next dry dock in May of 2001
Condition: Unknown
Due 29 September 2000
Resolved 29 September 2000
Fire Fighting
Issued 9 July 2000 Resolved
CLEARED AND REPAIR BLOCK SPRINKLER HEADS IN INFERMARY.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Electrical
Issued 9 July 2000 Resolved
Remove dead end wire throught out vessel.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Accommodation/Occupational Safety
Issued 9 July 2000 Resolved
Remove rags from ventilation vents in the laundry room and replace screens.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Accommodation/Occupational Safety
Issued 9 July 2000 Resolved
Replace bulkhead covering of insulation in the laundry room next to dry.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Lifesaving
Issued 9 July 2000 Resolved
REPLACE ALL BROKEN WINDOWS ON THE PROMINOD DECK BELOW LIFE BOATS.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Fire Fighting
Issued 9 July 2000 Resolved
Replace insulation above laundry room door.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Fire Fighting
Issued 9 July 2000 Resolved
Remove stowed carpet from air castle on Focsle.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Fire Fighting
Issued 9 July 2000 Resolved
REMOVE RACK AND STORES FROM PASSAGEWAY OUTSIDE OF THE DRY STORES OFFICE.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Lifesaving
Issued 9 July 2000 Resolved
SECURE OR RPLACE DRAIN COVERS AFT OF INFERMARY.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Unknown
Issued 4 June 2000 Resolved
PRIMARY THERMOSTAT PROBE AND SECONDARY SAFETY THERMOSTAT EQUIPMENT FOR THE GALLEY DEEP FAT FRYER FAILED TO FUNCTION PROPERLY AS DESIGNED.
Condition: Unknown
Due 9 July 2000
Resolved 14 June 2000
Lifesaving
Issued 2 April 2000 Resolved
Demonstrate launch of davit launched liferaft prior to 02May00.
Condition: Unknown
Due 2 May 2000
Resolved 24 April 2000
Lifesaving
Issued 2 April 2000 Resolved
Provide letter from flag state indicating reason for extending normal servicing date of liferafts by 5 months, provide by 02May00.
Condition: Unknown
Due 2 May 2000
Resolved 24 April 2000
Lifesaving
Issued 2 April 2000 Resolved
Provide video of launching of port side life boats by 02May00.
Condition: Unknown
Due 2 May 2000
Resolved 24 April 2000
Lifesaving
Issued 2 April 2000 Resolved
Provide proof of adequacy of lighting level if low location lighting in vivinity of cabins located near U 10 and all in vicinity.
Condition: Unknown
Due 2 June 2000
Resolved 24 April 2000
Construction/Loadline
Issued 2 April 2000 Resolved
Identify wasted piping in bilge of main engine room to ballast tank(s). Provide flange cover to isolate ballast tanks.
Condition: Unknown
Due 13 April 2000
Resolved 24 April 2000
Engineering
Issued 2 April 2000 Resolved
Disconnect OWS piping into firemain discharge, provide plans of piping system.
Condition: Unknown
Due 13 April 2000
Resolved 24 April 2000
Construction/Loadline
Issued 2 April 2000 Resolved
Clean bilges in main engine room of excess oil.
Condition: Unknown
Due 4 June 2000
Resolved 4 June 2000
Engineering
Issued 2 April 2000 Resolved
Clean area of HFO at stbd main engine room and renew oil soaked insulation.
Condition: Unknown
Due 4 June 2000
Resolved 4 June 2000
Construction/Loadline
Issued 2 April 2000 Resolved
Clean bilge of loose articles that would block bilge suction.
Condition: Unknown
Due 4 June 2000
Resolved 4 June 2000
Electrical
Issued 2 April 2000 Resolved
PRIOR TO 10MAY00 PROVIDE CAUSE OF FIRE, CORRECTIVE ACTION FOR REPAIR TO DEEP FAT FRYER, REPORT ON POSSIBLE FAILURES TO PART AND ANY RELATED DEFECTSTO THIS PART. THE DEEP FAT FRYER WILL NOT BE USED UNTIL POSITVE CORRECTIVEACTION HAS BEEN TAKEN TO REPLACE DEFECTIVE PART. PROVIDE CLASS REPORT.
Condition: Unknown
Due 9 July 2000
Resolved 17 July 2000
Fire Fighting
Issued 13 January 2000 Resolved
CONDUCT ADDITIONAL TRAINING ON PROPER FIRE FIGHTING PROCEDURES AND DEMONSTRATE SATISFACTORY FIRE DRILL TO MSO TAMPA BOARDING OFFICER PRIOR TO 27JAN00.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Fire Fighting
Issued 13 January 2000 Resolved
13JAN00: ENSURE PROPER OPERATION OF ALL FIRE SCREEN DOORS, INCLUDING #308, 417, 423, 515, 604, 611, 615, AND 804. PRIOR TO DEPARTURE.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Construction/Loadline
Issued 13 January 2000 Resolved
MSO TAMPA BOARDING OFFICER CLEARED TP09,REISSUED TO REQUIRE CLASS REPORT ADDRESSING SATISFACTION WITH REPAIRS MADE AND OVERALL STRUCTURAL INTEGRITY OF THE LIFEBOAT FOUNDATIONS. PRIOR TO NEXT CG EXAM (6APR00).
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Lifesaving
Issued 13 January 2000 Resolved
EXAMINE EXTENT OF MINOR FIBERGLASS SURFACE DAMAGE TO LAUNCHES IN VARIOUS LOCATIONS. PROVIDE A CLASS REPORT PRIOR TO ANNUAL EXAM (APR00).
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Electrical
Issued 13 January 2000 Resolved
PRIOR TO 06APR00 REPAIR LAUNDRY LIGHT SWITCHES.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Accommodation/Occupational Safety
Issued 13 January 2000 Resolved
REMOVE ITEMS IN OPEN STORAGE AREA PROMENADE DECK FORWARD STBD. BETWEEN EXITDOORS.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Construction/Loadline
Issued 13 January 2000 Resolved
EXAMINE EXTENT OF WASTAGE TO AFT MOORING DECK (OVERHEAD OF CREW HEAD) AND UNDER LIFEBOAT FOUNDATIONS (PROMENADE DECK OVERHEAD) AND PROVIDE REPAIR RESULTS PRIOR TO 27JAN00.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Electrical
Issued 13 January 2000 Resolved
DETERMINE IF INSULATION IN ELECTRICAL LOCKER NEAR FSD 436 IS REQUIRED PER PLANS. INSTALL IF REQUIRED.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Lifesaving
Issued 13 January 2000 Resolved
CONDUCT ADDITIONAL TRAINING FOR CREW ASSIGNED AS BOAT ENGINEERS ON STARBOARD SIDE LIFEBOATS PRIOR TO 27JAN00 AND MAKE RECORDS AVAILABLE TO USCG BOARDING OFFICERS.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Electrical
Issued 13 January 2000 Resolved
SEE PSNS FOR DESCRIPTION.
Condition: Unknown
Due 13 February 2000
Resolved 27 January 2000
Documentation
Issued 13 January 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 January 2000
Resolved 24 January 2000
Construction/Loadline
Issued 6 April 1999 Resolved
PROVIDE PROPER BULKHEAD PENETRATION FOR 4" PVC PIPE ABOVE FSD S2. PROVIDE LETTER TO THE COGNIZANT [name withheld] IT WILL BE ACCOMPLISHED AND CLASS REPORT UPON COMPLETION.
Condition: Unknown
Due 21 May 1999
Resolved 24 May 1999
Unknown
Issued 6 April 1999 Resolved
PROVIDE INSULATION AT THE FOLLOWING AREAS: 605, 606, 509, 510, 416, 422, 404, 308, WTD 18 TWO PLACES PORT & STARBOARD, WTD 16C INSULATION OVER DOOR,WTD 17C BULKHEAD PORT & STARBOARD, AND THE STEWARD LOCKER NEXT TO A6.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 6 April 1999 Resolved
RENEW GAUGE ON FRESHWATER TANK FOR SPRINKLER SYSTEM.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Accommodation/Occupational Safety
Issued 6 April 1999 Resolved
RENEW #8 STEP FROM BOTTOM AFT STARBOARD LADDER TO MOORING DECK.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 6 April 1999 Resolved
PROVIDE UPDATED FIRE CONTROL PLANS.
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Unknown
Issued 6 April 1999 Resolved
PROVIDE DIRECTION ARROWS AROUND STAIRWELL PASSAGEWAY IN THE VICINTY OF CABINS A26-A27.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 6 April 1999 Resolved
RENEW DAVIT ARM WHEEL (AFT END UPPER WHEEL) FOR LIFEBOAT #15. PROVIDE LETTER TO COGNIZANT [name withheld] IT WILL BE ACCOMPLISHED AND CLASS REPORT UPON COMPLETION.
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Electrical
Issued 6 April 1999 Resolved
PROVIDE GLOBE ON LIGHT IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Unknown
Issued 6 April 1999 Resolved
PROVIDE DETERMINATION & REQUIREMENT TO INSULATE A-60 AROUND STAIRWELLS PER FIRE CONTROL PLAN. (EXAMPLE: STAIRWELL 402 & 043)._x001C_
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Construction/Loadline
Issued 6 April 1999 Resolved
PLUG PENETRATION OF WIRE RUN AT 403 AND PLUG DRAFT STOP AT M8.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 12 January 1999 Resolved
PROVIDE A CLASS REPORT FROM THE VESSEL'S CLASS AND A WRITTEN STATEMENT FROMTHE VESSEL'S FLAG ADMINISTRATION WITHIN 30 DAYS ATTESTING TO THE SUITABILITY OF THIS ARRANGEMENT OF THE EXPOSED WOOD IN THE OVERHEAD THROUGHOUT THE VESSEL.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Documentation
Issued 2 October 1998 Resolved
Tenders #3 and #4 did not have valid tender certicicates. Vessel may not use boats #3 and #4 in any U.S. Port as tenders until proof is given that boats have valid tender certificates.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Fire Fighting
Issued 3 July 1998 Resolved
INSTALL SMOKE DETECTORS AND SPRINKLERS IN ALL REFRIGERATED STORAGE AREAS._x001C_ NOTE: THIS REQUIREMENT WAS ISSUED PREVIOUSLY BY TAMMS, CASE#MI97037250. CLEARED BY MISTAKE.
Condition: Unknown
Due 3 July 1998
Resolved 3 July 1998
Fire Fighting
Issued 1 June 1998 Resolved
PROVIDE ACCEPTED B-15 RATED DOOR FOR THE BEAUTY PARLOR/MASSAGE PARLOR BULKHEAD UPPER DECK PORT SIDE.
Condition: Unknown
Due 1 June 1998
Resolved 1 June 1998
Fire Fighting
Issued 1 June 1998 Resolved
PROVIDE ACCESS COVER FOR THE ABOVE CEILING SMOKE DETECTOR LOCATED IN THE FORWARD AREA OF THE UPPER DECK.
Condition: Unknown
Due 1 June 1998
Resolved 1 June 1998
Lifesaving
Issued 1 June 1998 Resolved
PRIOR TO DEPARTING NEXT U.S. PORT WITH PASSENGERS CLEAN ALL MATERIAL UTILIZED DURING WET DOCK PERIOD FROM ALL SPACES TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. _x001C_ _x001C_
Condition: Unknown
Due 1 June 1998
Resolved 1 June 1998
Fire Fighting
Issued 24 January 1998 Resolved
INSTALL CLASS "A" BULKHEADS TO ELIMINATE DIRECT ACCESS TO THE STAIR TOWER FOR THE GIFT SHOP AND BEAUTY SALON ON THE RESTAURANT AND UPPER DECKS.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Fire Fighting
Issued 24 January 1998 Resolved
Demonstrate proper operation of the following fire screen doors:_x001C_ 402, 418, 439, 422, 516, 507, 508, 422, 604, 619P, 619S, 605, 451, 622, 712_x001C_
Condition: Unknown
Due 27 January 1998
Resolved 27 January 1998
Fire Fighting
Issued 24 January 1998 Resolved
POST UPDATED FIRE CONTROL PLAN FOLLOWING ACCEPTANCE BY THE COAST GUARD MARINE SAFETY CENTER.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Fire Fighting
Issued 24 January 1998 Resolved
INSTALL CLASS "A" BULKHEADS TO ELIMINATE DIRECT ACCESS TO STAIRWAY FROM CABINS 214, 215 AND 216.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Fire Fighting
Issued 24 January 1998 Resolved
Install missing insulation to Main Verticle Zone bulkhead near Fire Screen Door 620.
Condition: Unknown
Due 27 January 1998
Resolved 27 January 1998
Fire Fighting
Issued 24 January 1998 Resolved
Remove combustible material from storeroom, starboard Promenade deck near the deck exit door (FSD 703).
Condition: Unknown
Due 27 January 1998
Resolved 27 January 1998
Fire Fighting
Issued 24 January 1998 Resolved
RENEW OR REPLACE FIRE SCREEN DOORS 522 AND 523. ENSURE HOSE PORTS ARE INSTALLED ON DOORS.
Condition: Unknown
Due 24 January 1998
Resolved 24 January 1998
Fire Fighting
Issued 25 October 1997 Resolved
REMOVE EXCESSIVE COMBUSTIBLES FROM KEY ROOM OFFICE ON THE UPPER DECK.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Fire Fighting
Issued 25 October 1997 Resolved
PROVIDE PROPOSAL TO ELIMINATE ACCESS FROM SHORT CORRIDOR (TO CABINS 214, 215, AND 216) INTO ADJACENT STAIRWAY.
Condition: Unknown
Due 25 October 1997
Resolved 25 October 1997
Fire Fighting
Issued 25 October 1997 Resolved
PROVIDE DOCUMENTATION ON VESSEL'S INSTALLED SPRINKLER SYSTEM SHOWING COMPLIANCE WITH SOLAS 74,II-2 CH 12
Condition: Unknown
Due 25 October 1997
Resolved 25 October 1997
Fire Fighting
Issued 25 October 1997 Resolved
INSTALL SMOKE DETECTORS AND SPRINKLERS IN ALL REFRIGERATED STORAGE AREAS.
Condition: Unknown
Due 25 October 1997
Resolved 25 October 1997
Fire Fighting
Issued 25 October 1997 Resolved
REMOVE ALL COMBUSTIBLE MATERIAL FRON THE BACK OFFICE OF THE PURSER'S OFFICEON THE UPPER DECK.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Fire Fighting
Issued 25 October 1997 Resolved
SUBMIT UPDATED FIRE CONTROL PLAN TO THE MARINE SAFETY CENTER INDICATING ALLMODIFICATIONS AND CUURENT AS BUILT CONDITION. POST UPDATED FIRE CONTROL PLAN THROUGHOUT THE VESSEL_x001C_ SOLAS 74 REG II-2, 41-2.1.1
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Fire Fighting
Issued 25 October 1997 Resolved
PROVIDE A PROPOSAL TO RESOLVE DIRECT ACCESS OF GIFT SHOP AND BEAUTY SALON INTO SATIR TOWE ON RESTAURANT AND UPPER DECKS.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Fire Fighting
Issued 25 October 1997 Resolved
PROVIDE HOSE PORTS FOR ALL NEWLY INSTALLED FIRE SCREEN DOORS.
Condition: Unknown
Due 25 October 1997
Resolved 25 October 1997
Engineering
Issued 28 March 1997 Resolved
Submit to COTP letter or statement addressing repairs to port clutch.
Condition: Unknown
Due 28 March 1997
Resolved 1 April 1997
Engineering
Issued 28 March 1997 Resolved
Provide Class report of adequacy of the repairs/condition to the starboard shaft/propeller.
Condition: Unknown
Due 29 March 1997
Resolved 1 April 1997
Fire Fighting
Issued 15 March 1997 Resolved
PROPERLY REPAIR/WELD TEMPORARY REPAIR IN #8 SPRINKLER PIPING RUN IN SPACE ADJACENT TO STATION #8.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Lifesaving
Issued 15 March 1997 Resolved
REPLACE CLASS 1, CATEGORY 1 406 MHZ EPIRB.
Condition: Unknown
Due 15 March 1997
Resolved 25 April 1997
Lifesaving
Issued 15 March 1997 Resolved
DEMONSTRATE DEPLOYMENT OF DAVIT LAUNCHED LIFE RAFT FOR ANNUAL CONTROL VERIFICATION EXAM.
Condition: Unknown
Due 15 March 1997
Resolved 15 March 1997
Fire Fighting
Issued 28 January 1997 Resolved
REPLACE MISSING STRUCTURAL FIRE PROTECTION INSULATION IN VARIOUS LOCATIONS THROUGHOUT VESSEL (NOTED MISSING INSULATION OUTSIDE CABIN U85 & VARIOUS LOCATION).
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Fire Fighting
Issued 28 January 1997 Resolved
SEAL WIRE PENETRATIONS THROUGH OUTBOARD OF WATERTIGHT DOOR #4.
Condition: Unknown
Due 28 January 1997
Resolved 28 January 1997
Fire Fighting
Issued 28 January 1997 Resolved
RENEW HOSE FOR PORTABLE FIRE EXTINGUISHER ER16.
Condition: Unknown
Due 28 January 1997
Resolved 28 January 1997
Fire Fighting
Issued 28 January 1997 Resolved
PROVE CLOSURE OF FIRE DOORS U24, U16, U10, R7, R26, R25, R20, M18._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Fire Fighting
Issued 28 January 1997 Resolved
REPAIR ALL WASTED VENTILATION HOUSINGS ON THE BOAT DECK.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Fire Fighting
Issued 13 October 1995 Resolved
RENEW MISSING CLOSURE BOLTS TO #8 FAN ROOM INTAKE VENT CLOSURE.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Fire Fighting
Issued 13 October 1995 Resolved
INSTALL HANDLE TO FIRE MAIN ISOLATION VALVE LOCATED IN OVERHEAD IN WAY OF CABINS U40-U46.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Electrical
Issued 13 October 1995 Resolved
INSTALL COVER PLATE TO ELECTRICAL POWER DISTRIBUTION PANEL IN WAY OF FIRE STATION U5 SO BUS BAR IS NOT EXPOSED.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Accommodation/Occupational Safety
Issued 13 October 1995 Resolved
RENEW DETERIORATED INTAKE TRUCK LOCATED IN WAY OF #15 FAN ROOM INTAKE.
Condition: Unknown
Due 13 October 1995
Resolved 23 January 1996
Documentation
Issued 13 October 1995 Resolved
PROVIDE ONE ADDITIONAL LICENSED RADIO OFFICER IN ACCORDANCE WITH FLAG ADMINISTRATIONS ISSUED SAFE MANNING CERTIFICATE.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Fire Fighting
Issued 13 October 1995 Resolved
INSTALL OPERATING HANDLE TO FIRE DAMPER IN WAY OF BATTERY ROOM STBD SIDE.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Fire Fighting
Issued 13 October 1995 Resolved
RENEW OR REPAIR DEFECTIVE FIRE HYDRANT VALVE IN WAY OF #5 LIFEBOAT.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Fire Fighting
Issued 13 October 1995 Resolved
RENEW CLOSURE DEVICE FOR NATURAL VENTILATION DAMPER IN WAY OF GAS BOTTLE ROOM.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Fire Fighting
Issued 13 October 1995 Resolved
RENEW DETERIORATED FIRE DAMPER CASING LOCATED IN WAY OF FWD PILOT HOUSE BULKHEAD.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Fire Fighting
Issued 13 October 1995 Resolved
RENEW OR REPAIR DEFECTIVE CLOSURE DEVICE TO #8 FAN ROOM NATURAL VENTILATIONINTAKE.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Fire Fighting
Issued 13 October 1995 Resolved
RENEW DETERIORATED FIRE DAMPER CASING AND BLADE LOCATED IN WAY OF FAN ROOM S1.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Fire Fighting
Issued 13 October 1995 Resolved
INSTALL CLOSURE MECHANISM TO FIRE DAMPER #S3.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Fire Fighting
Issued 13 October 1995 Resolved
REPAIR INOPERABLE FIRE HYDRANT VALVES LOCATED AT THE FOLLOWING FIRE STATIONS: SP5,LB14,LB6,LB5,LB9,LB15,P16,P10,P8,P6,P9,P3,P5,P7,P15,U16,U14,U9,U13 AND U18.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Fire Fighting
Issued 13 October 1995 Resolved
REPAIR/RENEW INOPERABLE FIREMAIN ISOLATION VALVES LOCATED AT THE FOLLOWING LOCATIONS AS DEPICTED ON FIRE CONTROL PLAN: SP3 AND P11.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Fire Fighting
Issued 13 October 1995 Resolved
REPAIR/RENEW DEFECTIVE MAGNETIC HOLDBACKS TO FIRE DOORS LOCATED AT THE FOLLOWING LOCATIONS: S1, U70, AND FD21.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Fire Fighting
Issued 13 October 1995 Resolved
REPAIR OR RENEW INOPERABLE SPRINKLER SYSTEM INTERNATIONAL SHORE CONNECTION VALVE.
Condition: Unknown
Due 13 October 1995
Resolved 1 March 1996
Lifesaving
Issued 22 April 1995 Resolved
Free-up forward davit bottom aft wheel lifeboat #11.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Construction/Loadline
Issued 22 April 1995 Resolved
Repair F.S.D. maindeck M14 to properly latch.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Lifesaving
Issued 22 April 1995 Resolved
Free-up forward davit top wheel lifeboat #15.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Lifesaving
Issued 23 March 1995 Resolved
Free up Fwd Davit Bottom aft wheel LB #11.
Condition: Unknown
Due 22 April 1995
Resolved 27 April 1995
Lifesaving
Issued 23 March 1995 Resolved
Repair F.S.D. M14 to properly latch (main deck).
Condition: Unknown
Due 22 April 1995
Resolved 27 April 1995
Lifesaving
Issued 23 March 1995 Resolved
Free up Fwd Davit Fwd Top wheel. LB#15
Condition: Unknown
Due 22 April 1995
Resolved 27 April 1995
Fire Fighting
Issued 5 December 1994 Resolved
Repair fire screen door R-28 to latch properly.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 5 December 1994 Resolved
Replace burned out emergency light bulb aft Grand lounge port exit.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 5 December 1994 Resolved
Install "Exit" signs on forward posts port & starboard in disco.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 5 December 1994 Resolved
Label all 'E' lights in Grand lounge.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Lifesaving
Issued 5 December 1994 Resolved
Repair life boat #15 forward davit wheels to roll freely.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Fire Fighting
Issued 5 December 1994 Resolved
Repair fire screen door P-10 where rubbing on ceiling.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Accommodation/Occupational Safety
Issued 5 December 1994 Resolved
Screw down non-skid ladder tread starboard outside ladder from sundeck to Promanade deck.
Condition: Unknown
Due 19 December 1994
Resolved 12 December 1994
Electrical
Issued 5 December 1994 Resolved
Replace red emergency light bulbs with white in disco.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Electrical
Issued 5 December 1994 Resolved
Replace burned out bulb lower disco stardboard stair.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Documentation
Issued 5 December 1994 Resolved
Log time & date for each side port door opening and closing.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Fire Fighting
Issued 5 December 1994 Resolved
Adjust port & starboard double fire screen doors to close & latch in Grand lounge.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 5 December 1994 Resolved
Lloyds class to survey Grand lounge and Casino for proper coverage by emergency lighting.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 5 December 1994 Resolved
Install lighted exit sign at aft exit in disco.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Engineering
Issued 6 June 1994 Resolved
A VIO OF 33 CFR 155.430 IN THAT THE VESSEL DID NOT HAVE ON BOARD A STANDARDDISCHARGE CONNECTION FOR BILGE SLOPS. CORRECT PRIOR TO QUARTERLY EXAM.ON 23JUN94_x001C_ _x001C_
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Unknown
Issued 6 June 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 June 1994
Resolved 16 June 1994
Fire Fighting
Issued 10 May 1994 Resolved
PORTABLE FIRE EXTINGUISHERS MUST BE SERVICED BY COMPETENT SHIP'S FORCE.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Documentation
Issued 11 February 1994 Resolved
Provide current copy of Coast Pilot #5, 24th ed.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Fire Fighting
Issued 11 February 1994 Resolved
Repair fire screen doors to latch properly: U-1, R-26, R-24, M-13, M-14, M-19, M-35, M-36, M-33, and M-38.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Lifesaving
Issued 5 November 1993 Resolved
Post station bill in wheelhouse.
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Lifesaving
Issued 5 November 1993 Resolved
Repair lifeboat #5 boat chock which is broken.
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Fire Fighting
Issued 5 November 1993 Resolved
Repair firescreen doors P2-A, U-1, U-10, P-35 and crew door next to M-7.
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Lifesaving
Issued 5 November 1993 Resolved
The portable radios used during drills are inadequate for battery life and interference.
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Lifesaving
Issued 5 November 1993 Resolved
The majority of l/b davits appear wasted to various degrees, including armsand tracks. Flag state is to provide written evidence that all davits are in acceptable condition regarding plate thickness. Several areas are notedto have red had patches over large pitted areas.
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Lifesaving
Issued 5 November 1993 Resolved
Repair lifeboat no. 11-a keel rail/grab bar an daft davit arm roller which does not rotate.
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Lifesaving
Issued 5 November 1993 Resolved
Repair lifeboat no. 15 davit arm rollers which do not rotate.
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Unknown
Issued 29 August 1993 Resolved
VESSEL DISCHARGES PLASTIC (CLINKERS) AT SEA.
Condition: Unknown
Due 29 August 1993
Resolved 14 September 1993
Accommodation/Occupational Safety
Issued 10 August 1991 Resolved
PHOTOCENTER IN STAIRTOWER (RESTAURANT DK., FR.42) DOES NOT SHOW ON FIRE CONTROL PLANS NOR ARE THE BOUNDRIES IN COMPLIANCE WITH SOLAS (A-0).
Condition: Unknown
Due 10 August 1991
Resolved 10 August 1991
Accommodation/Occupational Safety
Issued 10 August 1991 Resolved
LINEN LOCKER ON UPPER DECK FR. 82 INSIDE STAIRTOWER ENCLOSURE REQUIRES SPRINKLER HEAD INSTALLED TO COVER THE ENTIRE SPACE. BOUNDRIES OF THE LINEN LOCKER DO NOT CONFORM TO SOLAS REQUIREMENTS. LOCKER IS NOT SHOWN ON THE FIRE CONTROL PLAN.
Condition: Unknown
Due 10 August 1991
Resolved 10 August 1991
Accommodation/Occupational Safety
Issued 10 August 1991 Resolved
STAIRTOWER AT FR. 125 HAS NO INSTALLED SPRIKLER PROTECTION OR FIRE DETECTION SYSTEMS. NOTED THAT COMBUSTIBLES ARE STORED IN THIS STAIRTOWER.
Condition: Unknown
Due 10 August 1991
Resolved 10 August 1991