Inspection history · 21
13 April 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8347079
4 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319946
17 April 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8096926
14 May 2024
Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7906209
27 February 2024
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7882563
3 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7680385
17 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7452959
18 April 2022
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7434174
11 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7411212
20 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7196925
31 August 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7049287
20 February 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6919190
17 July 2019
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6753379
16 April 2019
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6663767
15 May 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6421067
22 January 2018
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6349677
9 January 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6285789
11 October 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6285765
25 May 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6167418
17 May 2017
DAPI Audit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6154102
17 May 2016
Internal Structural Exam · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5968566
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 April 2025
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. MI's found the following:
(1) smoke detectors not interconnected
(2) smoke detectors not UL approved
(3) no smoke detection in the machinery space
Vessels route is restricted to a limited coastwise route, which is not more than 20 nautical miles from harbor of safe refuge.
46 CFR 181.405
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 2 February 2026
Resolution: Interconnected smoke detectors installed and operate satisfactory.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 April 2025
Resolved
Provisions shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected. Engine room dampeners on port and starboard side were not gas tight.
46 CFR 181.20-35
"Old T"
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2025
Resolved 20 May 2025
Resolution: photo of damper flush with vent
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 April 2025
Resolved
Suitable covers, guards, or rails shall be installed in a way of all exposed and hazardous places such as gears, machinery, etc. No guard in place to protect against the exposed moving belts on the generator and both engines.
46 CFR 177.35-15
"Old T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2025
Resolved 7 July 2025
Resolution: Guards installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 April 2025
Resolved
At each inspection for certification...all observed hazardous situations must be corrected and in satisfactory condition. MI observed starboard shaft seal leak while underway.
46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2025
Resolved 20 May 2025
Resolution: Shaft seal repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level.
The High water indicator for the Engine room space was inoperable. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
Resolution: Verified proper operation of the Bilge High Level Indicator
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.
The Bilge indicator for the Rudder compartment was inoperable in automatic mode.
46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 4 December 2025
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 14 May 2024
Resolved
A vessel must comply with the applicable design, equipment, personnel, procedures, and records requirements of 33 CFR 151, 155 and 156.
The vessel had no Garbage/Waste Management Plan
46 CFR 184.702(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 4 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2024
Resolved
Each Ring life buoy must be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150.
Ring buoy on board was faded and unable to read the approval label.
46 CFR 182.70(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 4 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2024
Resolved
Water lubricated rubber bearings must be rebushed when any water groove is half the original depth. Vessel's STBD side shaft water lubricated bearing was found to be wasted.
46CFR61.20-23(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: New water lubricated bearing was added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2024
Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings and has high resistance to
salt water, petroleum oils and vibration.
Fuel fill hose at tank is not fuel rated.
46CFR182.20-40(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: New proper hose was added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that A positive shutoff valve is installed at the hull penetration.
Forward storage compartment's electronic bilge pump doesn't have a valve at the near the thru hull.
46CFR182.520(e)(7)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: Valve was added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 February 2024
Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. The forward STBD ball valve was unable to be examined and the second STBD ball valve was found to not be operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: New valve was added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 February 2024
Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews, Where space limitations make deck rails impractical such as at narrow catwalks in way of deckhouse sides, hand grabs may be substituted.
Railings were not installed during drydock.
46CFR177.35(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: All rails were back in place meeting requirements.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 27 February 2024
Resolved
The operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include— (1) Closing each valve leading to an overboard discharge and removing the handle; (2) Padlocking each valve leading to an overboard discharge in the closed position; or (3) Using
a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Sewage discharge valve was found unsecured.
33CFR159.7(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: Overboard discharge was locked.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 February 2024
Resolved
Each hatch cover must— (1) Have securing-devices; and
(2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss.
46CFR179.360(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: Securing-device was added to hatch.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 May 2022
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. No alcohol testing devices onboard vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2022
Resolution: Provided Proof of Alcohol Testing Strips onboard
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 May 2022
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Pre-engineered system annual inspection 01 months overdue.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: Vessel operated provided photo proof of Inspection of Pre-Engineered system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2022
Resolved
Valves for removing water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel leakage. 02 Fuel filter housing drains missing plugs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: Vessel Operator provided photo proof of plugged drain plug
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 May 2022
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Automatic bilge pump light in pilothouse inoperable for Tank room bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: Operator provided digital proof of operable bilge switch
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 May 2022
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Communications Act Radiotelephony Certificates may be obtained from the Commission's National Call Center - [phone withheld] - or from its forms contractor. No radiotelephony certificate
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: Operator provided proof of new Radio Certificate
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 May 2022
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16) (incorporated by reference; see 46 CFR 175.600). 03 child & 07 adult lifejackets found with wasted type 1 retroreflective material. Total passengers allowed restricted from 88 to 85m w/ no more than 09 children until corrected.
Action required: 705 - Other - as specified
Resolved 7 June 2022
Resolution: Provided proof of replacement Lifejackets
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2022
Resolved
Electrical equipment exposed to the weather must be watertight. Shore tie and shore tie outlet cable wires exposed from outer cable sheathing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: Provided digital proof of repaired shore tie cord.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2022
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Ring buoy float light missing battery.
Action required: 10 - Deficiency Rectified
Resolved 17 May 2022
Resolution: Replaced battery on the spot
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2022
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Fire pump pressure gauge inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: Provided digital proof of replaced and working gauge on fire pump
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 May 2021
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Receptacle in Forward space found to not have an outlet cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 May 2021
Resolution: Vessel Operator provided photgraphic proof of covered outlet.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 August 2020
Resolved
Provide 08 additional valid visual distress signals. Vessels on a Limited Coastwise route are required to carry a minimum of twelve (12) VDS's onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2020
Resolution: obtained.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 31 August 2020
Resolved
Provide new unexpired hydrostatic release for EPIRB. Current unit expired in April 2020.
Vessel restricted to operation within 03 miles from shore until provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 September 2020
Resolution: release obtained and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2019
Resolved
Piping for steering line in forward space to controls is corroded and seeping. Crop and renew piping in hydraulic steering line. 46 CFR 182.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 28 May 2019
Resolution: Vessel O/O made proper repairs to the hydraulic steering line and showed proper operation to the attending Marine Inspector.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 January 2018
Resolved
Seal bilge suction pipe piping penetration in aft steering bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 19 March 2018
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Conductor
Issued 22 January 2018
Resolved
Repair any loose or corroded connections in vessels bonding system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 19 March 2018
Resolution: Corrected.
Construction/Loadline › Structures › Deck Plating
Issued 22 January 2018
Resolved
Repair soft/decayed areas of deck, iwo aft corners.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 19 March 2018
Resolution: Corrected.
Engineering › Bilge Water Management System › Piping
Issued 22 January 2018
Resolved
Provide permanent metallic cap for unused thru-hull fitting on port side hull, engine room. Currently cap is PVC & should be metallic or fitting can be permnently removed & penetration closed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 19 March 2018
Resolution: Corrected.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 October 2017
Resolved
Vessel prohibited from carrying passengers for hire after 30Nov2017, until a credit drydock/hull exam is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2018
Resolution: Completed drydock exam.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 May 2016
Resolved
SSDG will not shut down upon system activation. Prove proper operation of engine shutdown device.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 1 June 2016
Electrical › Electric Supply System (service) › Cable
Issued 17 May 2016
Resolved
Repair bonding system conductors in tank space as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 May 2016
Resolved
Provide forward masthead & stern light IAW Navigation Rules.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016