Records from 1993 to 2026. Most recent: inspection, 13 April 2026.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 April 2025
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. MI's found the following:
(1) smoke detectors not interconnected
(2) smoke detectors not UL approved
(3) no smoke detection in the machinery space
Vessels route is restricted to a limited coastwise route, which is not more than 20 nautical miles from harbor of safe refuge.
46 CFR 181.405
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 2 February 2026
Resolution: Interconnected smoke detectors installed and operate satisfactory.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 April 2025
Resolved
Provisions shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected. Engine room dampeners on port and starboard side were not gas tight.
46 CFR 181.20-35
"Old T"
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2025
Resolved 20 May 2025
Resolution: photo of damper flush with vent
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 April 2025
Resolved
Suitable covers, guards, or rails shall be installed in a way of all exposed and hazardous places such as gears, machinery, etc. No guard in place to protect against the exposed moving belts on the generator and both engines.
46 CFR 177.35-15
"Old T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2025
Resolved 7 July 2025
Resolution: Guards installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 April 2025
Resolved
At each inspection for certification...all observed hazardous situations must be corrected and in satisfactory condition. MI observed starboard shaft seal leak while underway.
46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2025
Resolved 20 May 2025
Resolution: Shaft seal repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level.
The High water indicator for the Engine room space was inoperable. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
Resolution: Verified proper operation of the Bilge High Level Indicator
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.
The Bilge indicator for the Rudder compartment was inoperable in automatic mode.
46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 4 December 2025
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 14 May 2024
Resolved
A vessel must comply with the applicable design, equipment, personnel, procedures, and records requirements of 33 CFR 151, 155 and 156.
The vessel had no Garbage/Waste Management Plan
46 CFR 184.702(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 4 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2024
Resolved
Each Ring life buoy must be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150.
Ring buoy on board was faded and unable to read the approval label.
46 CFR 182.70(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 4 December 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2024
Resolved
Water lubricated rubber bearings must be rebushed when any water groove is half the original depth. Vessel's STBD side shaft water lubricated bearing was found to be wasted.
46CFR61.20-23(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: New water lubricated bearing was added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2024
Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings and has high resistance to
salt water, petroleum oils and vibration.
Fuel fill hose at tank is not fuel rated.
46CFR182.20-40(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: New proper hose was added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that A positive shutoff valve is installed at the hull penetration.
Forward storage compartment's electronic bilge pump doesn't have a valve at the near the thru hull.
46CFR182.520(e)(7)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: Valve was added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 February 2024
Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. The forward STBD ball valve was unable to be examined and the second STBD ball valve was found to not be operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: New valve was added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 February 2024
Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews, Where space limitations make deck rails impractical such as at narrow catwalks in way of deckhouse sides, hand grabs may be substituted.
Railings were not installed during drydock.
46CFR177.35(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: All rails were back in place meeting requirements.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 27 February 2024
Resolved
The operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include— (1) Closing each valve leading to an overboard discharge and removing the handle; (2) Padlocking each valve leading to an overboard discharge in the closed position; or (3) Using
a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Sewage discharge valve was found unsecured.
33CFR159.7(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: Overboard discharge was locked.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 February 2024
Resolved
Each hatch cover must— (1) Have securing-devices; and
(2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss.
46CFR179.360(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: Securing-device was added to hatch.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 May 2022
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. No alcohol testing devices onboard vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2022
Resolution: Provided Proof of Alcohol Testing Strips onboard
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 May 2022
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Pre-engineered system annual inspection 01 months overdue.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: Vessel operated provided photo proof of Inspection of Pre-Engineered system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2022
Resolved
Valves for removing water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel leakage. 02 Fuel filter housing drains missing plugs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: Vessel Operator provided photo proof of plugged drain plug
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 May 2022
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Automatic bilge pump light in pilothouse inoperable for Tank room bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: Operator provided digital proof of operable bilge switch
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 May 2022
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Communications Act Radiotelephony Certificates may be obtained from the Commission's National Call Center - [phone withheld] - or from its forms contractor. No radiotelephony certificate
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: Operator provided proof of new Radio Certificate
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 May 2022
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16) (incorporated by reference; see 46 CFR 175.600). 03 child & 07 adult lifejackets found with wasted type 1 retroreflective material. Total passengers allowed restricted from 88 to 85m w/ no more than 09 children until corrected.
Action required: 705 - Other - as specified
Resolved 7 June 2022
Resolution: Provided proof of replacement Lifejackets
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2022
Resolved
Electrical equipment exposed to the weather must be watertight. Shore tie and shore tie outlet cable wires exposed from outer cable sheathing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: Provided digital proof of repaired shore tie cord.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2022
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Ring buoy float light missing battery.
Action required: 10 - Deficiency Rectified
Resolved 17 May 2022
Resolution: Replaced battery on the spot
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2022
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Fire pump pressure gauge inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2022
Resolution: Provided digital proof of replaced and working gauge on fire pump
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 May 2021
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Receptacle in Forward space found to not have an outlet cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 May 2021
Resolution: Vessel Operator provided photgraphic proof of covered outlet.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 August 2020
Resolved
Provide 08 additional valid visual distress signals. Vessels on a Limited Coastwise route are required to carry a minimum of twelve (12) VDS's onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2020
Resolution: obtained.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 31 August 2020
Resolved
Provide new unexpired hydrostatic release for EPIRB. Current unit expired in April 2020.
Vessel restricted to operation within 03 miles from shore until provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 September 2020
Resolution: release obtained and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2019
Resolved
Piping for steering line in forward space to controls is corroded and seeping. Crop and renew piping in hydraulic steering line. 46 CFR 182.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 28 May 2019
Resolution: Vessel O/O made proper repairs to the hydraulic steering line and showed proper operation to the attending Marine Inspector.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 January 2018
Resolved
Seal bilge suction pipe piping penetration in aft steering bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 19 March 2018
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Conductor
Issued 22 January 2018
Resolved
Repair any loose or corroded connections in vessels bonding system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 19 March 2018
Resolution: Corrected.
Construction/Loadline › Structures › Deck Plating
Issued 22 January 2018
Resolved
Repair soft/decayed areas of deck, iwo aft corners.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 19 March 2018
Resolution: Corrected.
Engineering › Bilge Water Management System › Piping
Issued 22 January 2018
Resolved
Provide permanent metallic cap for unused thru-hull fitting on port side hull, engine room. Currently cap is PVC & should be metallic or fitting can be permnently removed & penetration closed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 19 March 2018
Resolution: Corrected.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 October 2017
Resolved
Vessel prohibited from carrying passengers for hire after 30Nov2017, until a credit drydock/hull exam is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2018
Resolution: Completed drydock exam.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 May 2016
Resolved
SSDG will not shut down upon system activation. Prove proper operation of engine shutdown device.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 1 June 2016
Electrical › Electric Supply System (service) › Cable
Issued 17 May 2016
Resolved
Repair bonding system conductors in tank space as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 May 2016
Resolved
Provide forward masthead & stern light IAW Navigation Rules.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Engineering › Bilge Water Management System › Strainer
Issued 11 June 2014
Resolved
Provide bilge piping strainer screens for engine and tank rooms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2014
Resolution: Bilge piping strainers installed.
Stability › Watertight Integrity › General
Issued 11 June 2014
Resolved
Plug thru-hull fitting/valve in tank room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2014
Resolution: Thru-hull fitting plugged.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 June 2014
Resolved
Provide lifejacket stowage markings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2014
Resolution: Stowage marking applied.
Lifesaving › Lifefloat › Netting
Issued 11 June 2014
Resolved
Repair lifefloat metal netting frames.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2014
Resolution: Lifefloat netting frames satisfactorily repaired.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 June 2014
Resolved
Provide FCC Safety Radio certificate.
Action required: 705 - Other - as specified
Due 11 July 2014
Resolved 14 August 2014
Resolution: FCC Safety Radio Certificate provided.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 11 June 2014
Resolved
Vessel does not have a MF radio installed as required by 47 CFR 80.905 for vessels operated beyond the 20 nautical miles but no more than 100 nautical miles. Vessel is restricted to not more than 20 nautical miles from shore.
Action required: 705 - Other - as specified
Resolved 12 September 2014
Resolution: Vessel has not installed required MF radio for a route of beyond 20 but no more than 100 nautical miles. Vessels route has been resticted to not more than not more 20 nautical miles from shore.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 22 June 2012
Resolved
Vessel is limited to carrying 9 children due to # of life jackets. Due 06July2012.
Action required: 705 - Other - as specified
Due 6 July 2012
Resolved 6 July 2012
Resolution: Attended vessel to verify the required amount of child sized PFD''s are onboard.
Fire Fighting › Fire Hoses › Diameter
Issued 22 June 2012
Resolved
Provide proper operation of the fire hose. Vessel has been out of service since 2007 and must comply with New T 46CFR181.320. Prior to carrying more than 49 passengers, due 06July2012.
Action required: 705 - Other - as specified
Due 6 July 2012
Resolved 6 July 2012
Resolution: Attended vessel to witness proper operation of the fire pump and fire hose.
Fire Fighting › Fire Pumps › Pressure
Issued 22 June 2012
Resolved
Install a pressure gauge on the fire pump. 46CFR181.300. due 06July2012.
Action required: 705 - Other - as specified
Due 6 July 2012
Resolved 6 July 2012
Resolution: Attended vessel, a pressure gauge was installed on the discharge side of the fire pump.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 June 2012
Resolved
Remove dead end wires and install covers on outlets throughout vessel. Due 06July2012.
Action required: 705 - Other - as specified
Due 6 July 2012
Resolved 6 July 2012
Resolution: Attended vessel, all dead end wires are removed and outlet covers are installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 22 June 2012
Resolved
Replace feeder cable on gen set (wires are too tight and might pull out due to vibration). Due 06July2012.
Action required: 705 - Other - as specified
Due 6 July 2012
Resolved 6 July 2012
Resolution: Attended vessel, the feeder wire was replaced satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 June 2012
Resolved
Vessel has twin screws, the shaft from the engine to the stern tube is approx 4 ft. A guard must be installed around port and stbd shafts to eliminate the exposed hazard.
Action required: 705 - Other - as specified
Due 31 July 2012
Resolved 31 July 2012
Resolution: Received photos from owner attesting to satisfactory installation of guards.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 22 June 2012
Resolved
Vessel has a oceans route and does not have life jacket lights on any of the PFDs. The vessel's route cannot extend more than 20 miles from a harbor of safe refuge. All life jackets onboard must have lights IAW 46 CFR 180.75. Due 06 August 2012.
Action required: 705 - Other - as specified
Due 6 August 2012
Resolved 6 August 2012
Resolution: Attended vessel, verified life jacket lights are installed. 50 jackets are equipped with lights, vessel can only carry 50 persons on a oceans or coastwise route.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 14 September 2004
Resolved
Make anchor windlass hydraulic hose penetrations watertight.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Deck/Cargo › Mooring/Anchoring › Winch
Issued 14 September 2004
Resolved
Mount anchor windlass directional control valve.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 September 2004
Resolved
Post COI in pilothouse.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 14 September 2004
Resolved
Provide gooseneck for anchor line deck penetration.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 14 September 2004
Resolved
Properly terminate bilge pump wires in forward compartment.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Engineering › Freshwater System (cylinder head cooling) › Power Supply
Issued 14 September 2004
Resolved
Provide switch cover for freshwater pump.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Engineering › Fuel Oil Service System › Filter
Issued 14 September 2004
Resolved
Install flame inmpingement bowl on generator fuel filter.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 September 2004
Resolved
Prooperly install generator battery.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 14 September 2004
Resolved
Properly repair port exhaust leak.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Electrical › Electric Supply System (service) › Cable
Issued 14 September 2004
Resolved
Remove battery cables from standing water.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Electrical › Electric Supply System (service) › Battery Charger
Issued 14 September 2004
Resolved
Re-install electric cover on battery charger.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Engineering › Bilge Water Management System › Pump
Issued 14 September 2004
Resolved
Install clamps on electric bilge pump overboard discharge.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 14 September 2004
Resolved
Provide lagging for both MDE exhaust piping.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 17 June 2005
Operations/Management › Drills/Instruction
Issued 23 October 2003
Resolved
Prior to carrying passengers, complete satisfactoryfire and man overboard drills. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2003
Resolved 6 November 2003
Resolution: Witness satisfactory man overboard and fire drills.
Navigation › Collision/Grounding Avoidance
Issued 23 October 2003
Resolved
Prior to carrying passengers, prove proper operation of radar. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed proper installation and operation of the radar.
Lifesaving › Lifebuoys
Issued 23 October 2003
Resolved
Prior to carrying passengers, restow life floats to be float free. LEGACY COMPONENT DESC: Stowage
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed proper stowage of life rafts.
Lifesaving › Visual Distress Signals (General)
Issued 23 October 2003
Resolved
Repair all waterlights for life floats prior to operating with passengers. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed proper operation of waterlights.
Lifesaving › Lifejacket/PFD (General)
Issued 23 October 2003
Resolved
Vessel is limited to limited coastwise route until life jacket lights are properly installed on life jackets. LEGACY COMPONENT DESC: Lights
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed proper installation of life jacket lights.
Navigation › Electronic Positioning
Issued 23 October 2003
Resolved
Prior to carrying passengers beyond three miles of land, provide hydro release and batteries for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2003
Resolved 6 November 2003
Resolution: Witnessed proper installation of hydro release and batteries for the EPIRB.
Lifesaving › Visual Distress Signals (General)
Issued 23 October 2003
Resolved
Vessel is limited to 30 minute runs until flares and smoke sinals are provided.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed the installation of the proper amount of visual distress signals.
Communications › Internal Communications System
Issued 23 October 2003
Resolved
Prove proper operation of installed P.A. system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed the proper operation of the installed P.A. system.
Construction/Loadline › Structures
Issued 23 October 2003
Resolved
Replace lanyard on Aft lazeratte hatch. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed the proper installation of the lanyard to the aft lazeratte hatch.
Engineering › Bilge Water Management System
Issued 23 October 2003
Resolved
Repair automatic pump for dewatering in lazarette. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed proper operation of the lazarette automatic dewatering pump.
Engineering › Bilge Water Management System
Issued 23 October 2003
Resolved
Repair visual alarm in lazarette for high water level. LEGACY COMPONENT DESC: Interface Detector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed proper operation of the lazarette visual high water level alarm.
Engineering › Bilge Water Management System
Issued 23 October 2003
Resolved
Repair visual alarm in tank room for High water level. LEGACY COMPONENT DESC: Interface Detector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed proper operation of visual high water level alarm in the tank room.
Engineering › Bilge Water Management System
Issued 23 October 2003
Resolved
Label automatic bilge visual alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 31 October 2003
Resolution: Witnessed proper labeling of bilge visual alarms.
Lifesaving › Lifejacket/PFD (General)
Issued 23 October 2003
Resolved
Relabel life jacket storage area. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed proper labeling of life jacket stowage areas.
Lifesaving › Lifebuoys
Issued 23 October 2003
Resolved
Replace Ring Buoy line. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed the replacement of the ring bouy line.
Deck/Cargo › Mooring/Anchoring
Issued 23 October 2003
Resolved
Install anchor. LEGACY COMPONENT DESC: Anchor
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 31 October 2003
Resolution: Witnessed proper installation of the anchor.
Engineering › Sea-water System (primary cooling)
Issued 23 October 2003
Resolved
Install valve handle on sea suction in engine room. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 6 November 2003
Resolution: Witnessed the proper installation of the sea suction of the valve handle in the engine room
Engineering › Fuel Oil Service System
Issued 23 October 2003
Resolved
Remove fuel line from starboard engine filter (draw line). LEGACY COMPONENT DESC: Filter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 28 October 2003
Resolution: Witnessed the removal of the starboard engine fuel filter draw line.
Engineering › Bilge Water Management System
Issued 23 October 2003
Resolved
Install stainer in lazarette bilge suction. LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 31 October 2003
Resolution: Witnessed the proper installation of the lazarette bilge suction stainer.
Engineering
Issued 23 October 2003
Resolved
Remove excess oil from engine room bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 31 October 2003
Resolution: Witnessed the proper removal of the excess oil from the engine room bilges.
Electrical › Electric Generation Source (service)
Issued 23 October 2003
Resolved
Prove proper operation of generator. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 31 October 2003
Resolution: Witnessed the proper operation of the generator.
Engineering › Bilge Water Management System
Issued 8 July 2003
Resolved
Properly repair all of the electric bilge pumps and prove proper operation. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2003
Resolution: Tested all electric bilge pumps.
Construction/Loadline › Markings
Issued 8 July 2003
Resolved
Place the name and homeport of the vessel on the stern of the vessel. LEGACY COMPONENT DESC: Vessel Name/Home Port
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2003
Resolved 22 July 2003
Construction/Loadline › Structures
Issued 1 July 2003
Resolved
Renew gasket on lazarette watertight hatch. LEGACY COMPONENT DESC: Scuttle
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 11 July 2003
Resolution: Observed new gasket on the watertight scuttle.
Construction/Loadline › Structures
Issued 1 July 2003
Resolved
Make permanent repairs to cracked FRP at deck to transom connection approx. 4 feet long in way of centerline in lazarette. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 8 July 2003
Resolution: Examined satisfactory FRP repair.
Construction/Loadline › Penetrations
Issued 1 July 2003
Resolved
Replace the fractured port rudder stuffing tube. Identified during inspection Activity #1831821 on 01Jul03 and Investigation Activity #1839736 on 26Jun03. LEGACY COMPONENT DESC: Valve Flange
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2003
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 1 July 2003
Resolved
Vessel was not properly labeled with name and home port.
Condition: Improper/Lack of Maintenance
Due 22 July 2003
Resolved 22 July 2003
Resolution: [name withheld] sent in a current picture of the vessel displaying the name and homeport.
Engineering › Bilge Water Management System
Issued 22 August 2002
Resolved
Install strainers to permanent bilge piping in each compartment. LEGACY COMPONENT DESC: Strainer
Due 13 September 2002
Resolved 3 October 2002
Resolution: Phone conversation with vsl rep confirmed bilge strainer in place. Pictures enroute for permanent file.
Engineering › Bilge Water Management System
Issued 22 August 2002
Resolved
Make repairs to bilge piping in tank compartment. LEGACY COMPONENT DESC: Piping
Due 13 September 2002
Resolved 11 September 2002
Stability › Watertight Integrity
Issued 22 August 2002
Resolved
Make repairs to aft tankroom bulkhead where bilge pipe penetrates.
Due 13 September 2002
Resolved 11 September 2002
Engineering › Generator (propulsion/auxiliary-electric)
Issued 22 August 2002
Resolved
Make repairs to raw water cooling pump to generator.
Due 23 August 2002
Resolved 23 August 2002
Resolution: Recieved fax that repairs were made to generator.
Electrical › Lighting (service)
Issued 22 August 2002
Resolved
Repalce glass light fixture in tankroom. LEGACY COMPONENT DESC: Lighting Fixture
Due 13 September 2002
Resolved 11 September 2002
Stability › Watertight Integrity
Issued 22 August 2002
Resolved
Replace/repair gasket to hatch to tankroom compartment.
Due 13 September 2002
Resolved 11 September 2002
Operations/Management › Pollution
Issued 22 August 2002
Resolved
Remove standing oily water from the engine room.
Due 13 September 2002
Resolved 11 September 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 August 2002
Resolved
Vsl limited to carry a total of 38 persons on an Oceans route until personal marker lights are provided for each additional lifejacket up to the maximum passenger capacity for an Oceans route. LEGACY COMPONENT DESC: Lights
Due 31 March 2003
Resolved 6 November 2003
Resolution: Inspected during annual re-inspection.
Construction/Loadline › Markings
Issued 22 August 2002
Resolved
Permanently mark stern of vessel with name and hailing port. LEGACY COMPONENT DESC: Vessel Name/Home Port
Due 31 March 2003
Resolved 22 July 2003
Documentation › Certificates/Documents
Issued 22 August 2002
Resolved
Vsl operating with expired Certificate of Inspection. LEGACY COMPONENT DESC: Certificate of Inspection
Due 22 August 2002
Resolved 22 August 2002
Resolution: Completed a Certificate of Inspection Exam.
Construction/Loadline
Issued 26 June 2001
Resolved
INSTALL LANYARDS ON ALL WEATHER DECK HATCHES NLT 10JUL01.
Condition: Unknown
Due 10 July 2001
Resolved 22 August 2002
Documentation
Issued 26 June 2001
Resolved
POST STABILITY LETTER UNDER GLASS NLT 10JUL01.
Condition: Unknown
Due 10 July 2001
Resolved 22 August 2002
Lifesaving
Issued 26 June 2001
Resolved
PROVIDE PROPER FIRST AID KIT NLT 10JUL01.
Condition: Unknown
Due 10 July 2001
Resolved 22 August 2002
Construction/Loadline
Issued 26 June 2001
Resolved
REBOLT AFT WATERTIGHT HATCH. NLT 10JUL01.
Condition: Unknown
Due 10 July 2001
Resolved 11 September 2002
Lifesaving
Issued 26 June 2001
Resolved
INSTALL WATERLIGHT ON LIFEFLOAT NLT 10JUL01
Condition: Unknown
Due 10 July 2001
Resolved 22 August 2002
Lifesaving
Issued 8 May 2000
Resolved
PROVIDE DOCUMENTATION FOR EPRIB'S BATTERY RENEWAL DATE.
Condition: Unknown
Due 8 May 2000
Resolved 8 May 2000
Fire Fighting
Issued 8 May 2000
Resolved
REPAIR FIRE/BILGE PUMP AND PROVE PROPER OPERATION.
Condition: Unknown
Due 8 May 2000
Resolved 8 May 2000
Construction/Loadline
Issued 8 May 2000
Resolved
REPAIR HIGH LEVEL BILGE ALARMS FOR ENGINE ROOM AND THE LAZERETTE COMPARTMENT.
Condition: Unknown
Due 8 May 2000
Resolved 8 May 2000
Accommodation/Occupational Safety
Issued 8 May 2000
Resolved
SECURE FRESH WATER PUMP TO PLATFORM IN ENGINE ROOM.
Condition: Unknown
Due 8 May 2000
Resolved 8 May 2000
Engineering
Issued 8 May 2000
Resolved
RENEW FUEL SHUT OFF HANDLES FOR EMERGENCY FUEL VALVES.
Condition: Unknown
Due 8 May 2000
Resolved 8 May 2000
Electrical
Issued 1 July 1997
Resolved
INSTALL COVER ON GENERATOR STARTING BATTERY BOX.
Condition: Unknown
Due 1 July 1997
Resolved 1 July 1997
Navigation
Issued 1 July 1997
Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 1 July 1997
Resolved 1 July 1997
Accommodation/Occupational Safety
Issued 1 July 1997
Resolved
POST EMERGENCY BROADCAST PROCEDURES IN VICINITY OF RADIOS.
Condition: Unknown
Due 1 July 1997
Resolved 1 July 1997
Lifesaving
Issued 1 July 1997
Resolved
CONDUCT FLEET-WIDE EMERGENCY DRILLS.
Condition: Unknown
Due 1 July 1997
Resolved 1 July 1997
Navigation
Issued 1 July 1997
Resolved
PROVIDE COPY OF NAVRULS.
Condition: Unknown
Due 1 July 1997
Resolved 1 July 1997
Construction/Loadline
Issued 13 June 1997
Resolved
COMPLETE INTERNAL INSPECTION OF MAIN ENGINE COMAPTMENT.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Engineering
Issued 13 June 1997
Resolved
PROVE PROPER OPERATION OF REBUILT PORT MAIN DEISEL ENGINE TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Construction/Loadline
Issued 13 June 1997
Resolved
PROVIDE CAPTURE CHAINS FOR ALL MAIN DECK HATCH COVERS.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Lifesaving
Issued 16 May 1996
Resolved
REPLACED WASTED LIFE FLOAT PADDLES THIS EXAM.
Condition: Unknown
Due 16 May 1996
Resolved 3 June 1996
Lifesaving
Issued 16 May 1996
Resolved
REPLACED WASTED RING BUOY THIS EXAM.
Condition: Unknown
Due 16 May 1996
Resolved 3 June 1996
Lifesaving
Issued 14 June 1995
Resolved
ROTTED GRAB LINE ON LIFEFLOATS - REPLACED IN KIND.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Lifesaving
Issued 14 June 1995
Resolved
ONE (1) CHILD PFD LABEL MISSING.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Fire Fighting
Issued 14 June 1995
Resolved
PROVIDE SERVICING REPORT FOR FIXED HALON SYSTEM IN ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 June 1995
Resolved 14 June 1995
Engineering
Issued 14 June 1995
Resolved
PROPERLY LABEL FUEL OIL SHUT OFF VALVES.
Condition: Unknown
Due 14 June 1995
Resolved 14 June 1995
Engineering
Issued 11 May 1994
Resolved
INSTALL FLAME SHIELDS ON FUEL FILTERS.
Condition: Unknown
Due 11 May 1994
Resolved 22 June 1994
Fire Fighting
Issued 13 May 1993
Resolved
PROVIDE HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Electrical
Issued 13 May 1993
Resolved
SEAL ELECTRICAL PENETRATIONS IN PILOTHOUSE OVERHEAD.
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Lifesaving
Issued 13 May 1993
Resolved
PROVIDE THREE(03) ADDITIONAL ADULT LIFE PRESERVERS.
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Navigation
Issued 13 May 1993
Resolved
PROVIDE OPERATIONAL TEST OF RADAR.
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Fire Fighting
Issued 13 May 1993
Resolved
PROVIDE A MARINE BRACKET FOR PORTABLE EXTINGUISHER IN PILOTHOUSE.
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Lifesaving
Issued 13 May 1993
Resolved
PROVIDE STOWAGE FOR TWENTY-SEVEN(27) LIFE PRESERVERS _x001C_ IAW 46 CFR 180.25-10(A).
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Construction/Loadline
Issued 13 May 1993
Resolved
PROVIDE ADEQUATE VENTILATION FOR COMPARTMENT BELOW FORE DECK STORAGE.
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Engineering
Issued 13 May 1993
Resolved
PROVE PROPER OPERATION OF STARBOARD ENGINE TO THE COGNIZANT OCMI.
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Fire Fighting
Issued 13 May 1993
Resolved
INSTALL GENERATOR SHUTDOWN FOR HALON RELEASE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Navigation
Issued 13 May 1993
Resolved
INSTALL SINGLE SIDE BAND RADIO TO CONFORM WITH FCC REQUIREMENTS TITLE 47 PRIOR TO OPERATING MORE THAN TWENTY(20) MILES FROM LAND.
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Electrical
Issued 13 May 1993
Resolved
INSTALL FREQUENCY METER FOR 110 VOLT AC INSTALLATION.
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Lifesaving
Issued 13 May 1993
Resolved
INSTALL CLASS "A" EPIRB PRIOR TO OPERATING MORE THAN TWENTY(20) MILES OFFSHORE.
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Fire Fighting
Issued 13 May 1993
Resolved
INSTALL CLOSURE HOOKS FOR ENGINE ROOM VENTS.
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Engineering
Issued 13 May 1993
Resolved
INSTALL LOCK NUT ON MAIN ENGINE STOP CELLENOID LINKAGE.
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Electrical
Issued 13 May 1993
Resolved
INSTALL ADDITIONAL RATING PLATE ON GENERATOR TO COMPLY WITH 46 CFR PART 180.10-5(F)(2).
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Engineering
Issued 13 May 1993
Resolved
INSTALL PLUGS ON MAIN ENGINE FUEL FILTER CANISTER DRAINS.
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993