CORA BETH II

CORA BETH II is a 1995 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1995, most recently in June 2026, along with 151 deficiencies, 4 operational controls and 3 casualty investigations between 2020 and 2024.

Records from 1995 to 2026. Most recent: inspection, 18 June 2026.

Built
1995
Last inspected
18 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM9031
419481
Flag
UNITED STATES
368028670, 368248860
Maury page id
psix-419481

Inspections, by type

…with no type recorded10
Years with a record 27 calendar years (1995–2026)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)56.0 ft × 16.0 ft × 8.5 ft
Registered tonnagegross 51 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARRO YACHTS INC · BIDDEFORD, ME, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 17 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Simplified, Net Ton
51 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM9031MMSI 368248860 · active · compulsorily equipped · granted 8 April 2022, expires 8 April 2032
WDJ9713MMSI 368028670 · active · voluntarily equipped · granted 23 March 2018, expires 23 March 2028
WDF8249MMSI 367492950 · expired · voluntarily equipped · granted 2 June 2011, cancelled 7 August 2021 · licensed under a name not among this hull’s recorded names (not shown)
WCR2841MMSI 366674110 · expired · compulsorily equipped · granted 12 April 2005, cancelled 4 July 2015 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DARK HORSE Passenger (Inspected) · MISLE 385477 · 10 September 2002 · activity 1673435

Inspection history · 69

18 June 2026 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8406249
24 November 2025 In-Service Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8284387
20 November 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8271740
15 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8271778
27 March 2025 Simplified Stability Test
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8102319
27 September 2024 Damage Survey · Plan Review "T" Boat
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8014231
10 September 2024 Damage Survey
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8000729
10 September 2024 Type not recorded
No type recorded · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8005831
27 March 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7885346
6 December 2023 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7833658
26 October 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7814932
5 October 2023 Plan Review "T" Boat
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7803985
28 March 2023 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7655216
21 February 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7640007
31 March 2022 COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7426196
26 January 2022 Examination of Repairs · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7383722
7 July 2021 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7248266
7 July 2021 Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7248394
26 March 2021 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7160853
9 March 2021 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7157144
12 November 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7093856
3 August 2020 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7024141
2 August 2020 Type not recorded
No type recorded · Station Gloucester · USCG Northeast District (CGD-NE) · Activity 7022461
2 August 2020 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7023447
30 May 2020 Type not recorded
No type recorded · USCGC TYBEE (WPB 1330) · USCG Northeast District (CGD-NE) · Activity 6965205
13 March 2020 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6924105
24 May 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6684020
27 March 2019 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6650984
21 June 2018 Hull Examination · COI Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6451573
30 August 2017 COI Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6255163
14 June 2017 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6175962
28 July 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5955670
20 July 2016 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5956539
20 June 2016 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5912912
8 March 2016 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5829388
2 October 2015 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5758576
11 July 2012 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4375525
8 May 2012 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4305195
15 September 2011 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4146796
28 July 2011 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4101790
19 November 2008 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3366125
3 September 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3317706
7 September 2007 Re-Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3054005
24 July 2006 Construction Oversight · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2723022
17 June 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2396175
18 August 2003 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1879408
8 July 2003 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1839284
1 July 2003 Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1832231
10 September 2002 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1673435
20 August 2002 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1671295
22 August 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1071659
26 June 2001 Hull Examination · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1435223
30 April 2001 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1412276
8 May 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1361484
6 July 1999 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1113855
21 June 1999 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 881717
14 June 1999 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 807638
24 April 1998 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1123842
11 July 1997 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 779491
8 July 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 778384
28 May 1997 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1113559
6 August 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1095314
30 May 1996 Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1085255
16 January 1996 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 872951
13 July 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 880730
20 June 1995 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 882962
16 May 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1192782
20 April 1995 MARPOL Annex V Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1174072
11 April 1995 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 848590

Deficiency record · 151

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 24 November 2025 Resolved
Provide a valid Certificate of Documentation prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2025
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 24 November 2025 Resolved
Conduct and document training as to the duties that each crewmember is expected to perform in an emergency situation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 May 2025 Resolved
EPIRB battery replaced before the date required by FCC regulations. Battery expired FEB 2025. Vessel restricted to 3 miles.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2025
Resolved 15 May 2025
Resolution: New EPIRB purchased and registered.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 May 2025 Resolved
Vessel required 6 day and 6 night distress signals. Vessel had 09 total. Vessel restricted to lakes, bays, and sounds.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2025
Resolved 15 May 2025
Resolution: Distress signals purchased.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 March 2024 Resolved
If a garden hose is used ... shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent metal. Vessel commercial grade garden hose that is used for a fire hose does not have a nozzle.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2024
Resolved 5 April 2024
Resolution: Owner fitted nozzle to hose.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 March 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. A power driven vessel underway shall exhibit a masthead light forward, sidelights, and a sternlight. Vessel does not have a sternlight.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2024
Resolved 27 August 2024
Resolution: Stern light installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 December 2023 Resolved
The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the condition of the shafting and bearings are in question. All of the vessel's cutlass bearings were worn beyond acceptable limits. Both forward cutlass bearings and the aft starboard cutlass bearing are to be renewed during next haulout period begining NOV2024, to be completed prior to carrying passengers. 46CFR176.670
Action required: 705 - Other - as specified
Due 30 November 2024
Resolved 5 March 2025
Resolution: Operator installed new cutlass bearings.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 30 March 2023 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. The hydrostatic release has passed the expiration date of 2 years from installation. Vessel restricted to 3 miles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 30 March 2023
Resolution: New hydrostatic release was purchased and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 30 March 2023 Resolved
Each life float must be fitted with a light. Batteries in 03 life float lights were of the spring type, while the light requires a screw type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 30 March 2023
Resolution: Correct batteries were purchased and installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 March 2023 Resolved
Each portable fire extinguisher must be of an approved type. Fire extinguishers onboard vessel are not provided with brackets indicated on extinguisher label, a requirement of approval.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 21 September 2023
Resolution: Brackets purchased and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 March 2023 Resolved
At each inspection, the owner or managing operator shall be prepared to conduct tests and have vessel ready for inspections of machinery, fuel, and piping systems. The raw water system for the port engine is leaking due to a failed gasket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 6 April 2023
Resolution: Strainer repaired and no longer leaking.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 30 March 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. The type III marine sanitation device has a hole in the tank which leaks sewage into the space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 7 April 2023
Resolution: Tank cap was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 March 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. Vessel is employing electronic charts with no mechanism to provide updates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 7 April 2023
Resolution: Charts being updated.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 July 2021 Resolved
A space containing propulsion machinery must be equipped with a fixed gas fire extinguishing system, in compliance with §181.410. Due to a fire on board the vessel, the fixed gas system was discharged. Vessel is restricted from carrying passengers until the system is replaced to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
Resolution: Confirmed and tested the installation of a new fireboy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 July 2021 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. While underway on 07JUL21, the starboard engine overheated. Identify the source of the failed cooling system and make repairs in accordance with the approved plan proposal.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
Resolution: Operator replaced the raw water pump and coolant cap. Conducted UW trials, brought the vessel up to temperature and observed no cooling issues via the gauge or leaks on the engine coolant system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 April 2021 Resolved
Flexible diesel fuel supply piping shall not penetrate watertight bulkheads. The two flexible fuel supply lines pass through the aft engine room watertight bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2021
Resolved 6 May 2021
Resolution: MI inspected installation of new fixed diesel fuel delivery piping which penetrates the aft engine room bulkhead, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 April 2021 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. There is no operational indicating light for the automatic bilge pumps at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2021
Resolved 6 May 2021
Resolution: Operator installed automatic bilge pump operation light at the operation station, tested all pumps sat.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 9 March 2021 Resolved
An enclosed or partially enclosed space within a vessel must be adequately ventilated in a manner suitable for the purpose of the space. While in the loading cradle, the ventilation ducts for the fuel tank room cracked on both sides of the vessel. Make permanent repairs to the vents.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 9 April 2021
Resolution: Verified repairs to the ventilation ducts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 August 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Identify and make repairs to the machinery system causing the smoke/fire aboard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2021
Resolution: Verified repairs of starboard engine during COI inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 August 2020 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Perform underway sea trials after making repairs to the machinery system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2021
Resolution: Completed sea trials during COI inspection, all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 July 2018 Resolved
Submit electrical plans to MSC for approval
Action required: 705 - Other - as specified
Due 9 August 2018
Resolved 4 August 2018
Resolution: Plans submitted to MSC for approval.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 9 July 2018 Resolved
Renew forward shaft bearing on port side (vsl will be granted a 1 yr credit)
Action required: 705 - Other - as specified
Due 31 July 2019
Resolved 27 March 2019
Resolution: Examined bearing; some weardown apparent on trailing end but leading end had visible grooves in satisfactory condition. Owner attested to no shaft or vibration issues during 2018 season.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 9 July 2018 Resolved
Provide valid radio operator's permit per 47 CFR 13.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 16 August 2018
Resolution: Received valid marine operator's permit.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 9 July 2018 Resolved
Prove proper operation of HF radio per 47 CFR 13. Route limited to 20 miles from shore.
Action required: 705 - Other - as specified
Due 23 July 2018
Resolved 26 July 2018
Resolution: HF radio serviced by Seatronics.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 July 2018 Resolved
Install check valves in bilge piping system as per 46 CFR 182.25-5 (OLD T).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 26 July 2018
Resolution: Check valves added in piping for each space serviced by bilge system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2018 Resolved
Provide proper fire fighting hose per 46 CFR 181.15-10 (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 26 July 2018
Resolution: Commercial grade fire fighting hose provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 July 2018 Resolved
Install proper flame screen on fuel vent pipe per 46 CFR 182.20-35 (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 26 July 2018
Resolution: flame screen properly installed in fuel vent pipe.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 9 July 2018 Resolved
Provide waste management plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 26 July 2018
Resolution: Waste management plan provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2018 Resolved
Provide emergency instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 26 July 2018
Resolution: Emergency instructions provided.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 9 July 2018 Resolved
Label upper deck passenger limit per 46 CFR 185.25-1 (OLD T).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 26 July 2018
Resolution: Upper deck pax limit labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 9 July 2018 Resolved
Install proper grab rail on ladder leading to upper deck per 46 CFR 177.35-1 (OLD T).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 26 July 2018
Resolution: Satisfactory grab rail installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 June 2017 Resolved
Vessel has not completed required Annual Inspection as listed on the Certificate of Inspection (COI). Annual Inspection was due by 20JUN2017. Inspection must be completed by 01AUG2017 or COI will be revoked.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2017
Resolved 30 August 2017
Resolution: COI is Expired. The vessel owner is in the process of selling the vessel and has made no attempt to schedule an inspection.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 July 2016 Resolved
Prove proper bilge high level alarm operation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2016
Resolved 29 July 2016
Resolution: MI witnessed proper operation of bilge alarms.
Lifesaving › Lifefloat › Serviceable
Issued 28 July 2016 Resolved
Properly repair or replace 01 life float forward. Pax count reduced to 41 & 03 crew (44 total) if operating 20NM from harbor of safe refuge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: MI confirmed by visual examination that the life float was removed from the vessel.
Lifesaving › Lifefloat › Markings
Issued 28 July 2016 Resolved
Properly mark remaining two life floats with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 28 July 2016
Resolution: Received e-mail pictures of proper marking.
Engineering › Fuel Oil Service System › Filter
Issued 20 June 2016 Resolved
Replace fuel strainer metal bowl-port side. 46 CFR 182.455(b)(6)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2016
Resolved 21 June 2016
Resolution: Owner replaced metal strainer bowl.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 June 2016 Resolved
Replace two flash lights with batteries. 46 CFR 183.430
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2016
Resolved 21 June 2016
Resolution: Owner bought new flashlights
Lifesaving › Lifefloat › Paddle
Issued 20 June 2016 Resolved
Replace 02 paddles for life floats and mark vessel name on all. 46 CFR 180.150(d)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2016
Resolved 21 June 2016
Resolution: Owner replaced paddles
Documentation › Logs/Records › Drug Test Records
Issued 20 June 2016 Resolved
Replace expired alcohol swabs (4). 46 CFR 4.06-3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 30 June 2016
Resolution: Operations Restricted to 2 hours from dock. Owner bought test kits.
Engineering › Freshwater System (piston cooling) › Piping
Issued 20 June 2016 Resolved
Repair Water Leak on port side engine exhaust (small hose replace and large stop leak).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2016
Resolved 21 June 2016
Resolution: Owner made appropriate repairs
Documentation › Markings/Placards › Lifejacket Placard
Issued 20 June 2016 Resolved
Post life jacket donning placard. 46 CFR 185.516
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2016
Resolved 21 June 2016
Resolution: Owner displayed proper placard for life jacket donning
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 20 June 2016 Resolved
Clean oil/debris from engine room bilges. 46 CFR 176-830(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 30 June 2016
Resolution: Bilges were clean from debris
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 20 June 2016 Resolved
Repair foam seal and holding hook on ventilation dampers. 46 CFR 182.465(h)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 30 June 2016
Resolution: Owner replaced seals on ventilation dampers
Engineering › Bilge Water Management System › Strainer
Issued 20 June 2016 Resolved
Repair strainers on bilge suction in forward space and lazarette. 46 CFR 182.510(b)
Condition: Improper/Lack of Maintenance
Due 30 June 2016
Resolved 30 June 2016
Resolution: Strainer was replaced
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 20 June 2016 Resolved
Add inspection port for collision space forward.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 30 June 2016
Resolution: Owner installed inspection port to the satisfaction of the MI.
Engineering › Pressure Vessel › Support
Issued 20 June 2016 Resolved
Reattach fuel tank grounding strap. 46 CFR 182.440(B)(4)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 30 June 2016
Resolution: Grounding strap was reattached.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 20 June 2016 Resolved
Reattach starboard side rudder stop. 46 CFR 182.610(a)(2)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 30 June 2016
Resolution: Rudder stop was installed
Lifesaving › Lifefloat › Serviceable
Issued 20 June 2016 Resolved
Repair/Replace forward life float. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 28 July 2016
Resolution: Owner given ample time to make proper repairs. Repairs were not made to satisfaction of attending marine inspectors. Life float removed from vessel. Passenger count reduced to 44 when operating beyond 20NM from harbor of safe refuge. COI ammended.
Lifesaving › Lifefloat › Serviceable
Issued 20 June 2016 Resolved
Repair seam on lower aft lifefloat. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 28 July 2016
Resolution: Satisfactory repair on seam made.
Lifesaving › Lifebuoys › Serviceable
Issued 20 June 2016 Resolved
Repair button hole on forward life ring. 46 CFR 176.808(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 28 July 2016
Resolution: Owner given ample time to properly repair button hole on life ring. Owner did not make proper repairs. Life ring removed from vessel. This equipment was additional to the one required on board.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 June 2016 Resolved
Replace two bolts on top deck forward rail. 46 CFR 177.900(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 30 June 2016
Resolution: Bolts were installed in railing.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 June 2016 Resolved
Install Battery box for 02 new batteries. 46 CFR 183.350(b)&(e)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 30 June 2016
Resolution: Battery box was replaced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 June 2016 Resolved
Replace cover on bilge alarm. 46 CFR 176.830
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 28 July 2016
Resolution: Light covers replaced with one clear plastic cover.
Construction/Loadline › Hull › Hull Plating
Issued 8 March 2016 Resolved
Vessel made unauthorized alterations to forward deck plate (removed anchor windlass). Vessel is not to carry passengers until a repair proposal is reviewed and approved by local OCMI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2016
Resolved 18 March 2016
Resolution: Office has received alteration proposal and approved all items.
Engineering › Fuel Oil Service System › Filter
Issued 2 October 2015 Resolved
Reinstall flame shields on both fuel filters in engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2015
Resolved 12 October 2015
Resolution: Reviewed forwarded e-mail from vessel rep from 09OCT12 with pictures of installed flame shields on both fuel filters. Def corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 October 2015 Resolved
Replace all plastic wire supports with metal ones.
Condition: Improper Installation
Due 2 November 2015
Resolved 2 November 2015
Resolution: Attended vessel to inspect wire support corrections.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 28 July 2011 Resolved
Stbd engine charging system is not operating properly. After extended cruise, when shut down, the Stbd engine will not start unless batteries are recharged by independent generator or shore tie. Repair charging/starting system and prove proper operation to the satisfaction of attending marine inspector prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2011
Resolved 29 July 2011
Resolution: The above deficiency corrected.
Electrical › Electric Supply System (service) › Cable
Issued 28 July 2011 Resolved
Multiple dead end wires in the vicinity of the main generator and forward of the engine room, remove to the satisfaction of the attending Marine Inspector.
Due 5 August 2011
Resolved 15 August 2011
Resolution: Attended vessel and cleared above deficiency.
Electrical › Electric Supply System (service) › Cable
Issued 28 July 2011 Resolved
Multiple dead end wires in the vicinity of the navigation console (bridge), remove to the satisfaction of the attending Marine Inspector.
Due 5 August 2011
Resolved 15 August 2011
Resolution: Attended vessel and cleared above deficiency.
Lifesaving › Lifebuoys › Serviceable
Issued 3 September 2008 Resolved
Replace worn / weathered lifering fwd of pilot house
Action required: 705 - Other - as specified
Due 4 October 2008
Resolved 7 November 2008
Resolution: REPLACED SAT.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 3 September 2008 Resolved
Permanently fasten outlet box hanging by ladder to engine oom
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 7 November 2008
Resolution: Outlet box remounted sat.
Engineering › Bilge Water Management System › Pump
Issued 3 September 2008 Resolved
Properly fasten electric "rule" bilge pump and float switch located in fwd deep well of engine room.
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 11 November 2008
Resolution: Rule pump mounted sat.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 3 September 2008 Resolved
Overhead fiberglass insulation in engine room hanging down, sheet metal panels rusted through exposing insulation. Repair and replace metal sheeting
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 7 November 2008
Resolution: All metal sheeting repaired sat.
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 7 September 2007 Resolved
Secondary means of discharge not connected, prove proper operation of installed Fireboy extinguisher system in engineroom
Action required: 705 - Other - as specified
Due 14 September 2007
Resolved 14 September 2007
Resolution: Inspected satisfactorily
Lifesaving › Lifefloat › Serviceable
Issued 7 September 2007 Resolved
Repair of replace one of four LF's - foam filling exposed on small portion of corner (6 in x 6 in area). Replace retro on remaining 3 LFs, replace deteriorated lines where neccessary, ensure 2 paddles w/ vessel name provided with each LF, properly stow w/ dunnage seperating upper LF from lower LF.
Action required: 705 - Other - as specified
Due 15 October 2007
Resolved 19 October 2007
Resolution: All repairs made sat.
Lifesaving › Lifebuoys › Serviceable
Issued 7 September 2007 Resolved
Replace deteriorated lifering fwd of pilot house
Action required: 705 - Other - as specified
Due 21 September 2007
Resolved 14 September 2007
Resolution: New ring installed
Engineering › Fuel Oil Service System › Hose
Issued 7 September 2007 Resolved
Replace 8 deteriorated hoses (supply-discharge) on racor filters in engineroom.
Action required: 705 - Other - as specified
Due 21 September 2007
Resolved 14 September 2007
Resolution: Hoses replaced
Navigation › Collision/Grounding Avoidance
Issued 18 August 2003 Resolved
Provide bell with minimum of 200mm.
Action required: 705 - Other - as specified
Due 18 September 2003
Resolved 17 September 2003
Resolution: Examined sat. 200mm bell.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 August 2003 Resolved
Repair stanchions where cracked on rail. LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 September 2003
Resolved 17 September 2003
Resolution: Examined sat. repairs to rails.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 18 August 2003 Resolved
Perform annual servicing for fixed and portable fire extinguishers and provide documentation. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2003
Resolved 17 September 2003
Resolution: Examined sat. inspection tags for fire extinguishers.
Engineering › Fuel Oil Storage/Transfer System
Issued 18 August 2003 Resolved
Provide and install flame screen in the fuel vent and sewage vent pipes. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2003
Resolved 17 September 2003
Resolution: Examined sat. 2-layerd flame screen in fuel vent.
Construction/Loadline › Structures
Issued 18 August 2003 Resolved
Provide plugs or seal for four holes in watertight coming, aft superstructure in IWO doors. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2003
Resolved 17 September 2003
Resolution: Examined plugs suitable for holes in coaming.
Construction/Loadline › Hull
Issued 8 July 2003 Resolved
Make proper FRP repair to impact damage on gunwale on starboard bow in way ofvessel name. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 15 July 2003
Communications › Alarms/Indicators
Issued 8 July 2003 Resolved
Prove proper operation of bilge high water alarms in sewage space and lazarette. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 16 July 2003
Construction/Loadline › Penetrations
Issued 8 July 2003 Resolved
Provide a handle for the salt water pump supply sea valve in sewage tank space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 16 July 2003
Construction/Loadline › Structures
Issued 8 July 2003 Resolved
Reattach gasket for lazarette hatch cover. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 16 July 2003
Engineering › Shafting/Propeller Arrangements
Issued 8 July 2003 Resolved
Renew port and starboard aft strut bearings. LEGACY COMPONENT DESC: Bearing
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 16 July 2003
Construction/Loadline › Penetrations
Issued 8 July 2003 Resolved
Renew sewage overboard valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2003
Resolved 16 July 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 July 2003 Resolved
Tighten loose hose clamps on port and starboard exhaust piping in lazarette. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 16 July 2003
Engineering › Shafting/Propeller Arrangements
Issued 8 July 2003 Resolved
Properly reinstall port and starboard propellers and struts. LEGACY COMPONENT DESC: Propeller (fixed pitch)
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 16 July 2003
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 July 2003 Resolved
Properly seal loose bulkhead penetration for bilge piping on forward engine room bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2003
Resolved 1 July 2003
Resolution: Penetration was sealed on-the-spot and verified satisfactory.
Stability › Watertight Integrity
Issued 20 August 2002 Resolved
Ensure collision bulkhead is watertight.
Due 6 September 2002
Resolved 22 August 2002
Resolution: Collision bulkhead watertight.
Documentation › Markings/Placards › Capacity Marking
Issued 20 August 2002 Resolved
Mark second deck with proper passenger capacity listed on COI.
Due 6 September 2002
Resolved 22 August 2002
Resolution: Second deck marked.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 August 2002 Resolved
Provide original Certificate of Inspection and post it in the pilot house.
Due 30 August 2002
Resolved 22 August 2002
Resolution: Original COI on board
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 August 2002 Resolved
Provide proof of crew enrollment in a Drug and Alcohol Program. Provide pre-employment testing, EAP, supervisory training, and 1-800 hotline numbers.
Due 21 August 2002
Resolved 22 August 2002
Resolution: Vessel and crew currently enrolled in a consortium.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 20 August 2002 Resolved
Provide servicing report for portable and fixed fire extinguisher system.
Due 21 August 2002
Resolved 22 August 2002
Resolution: Owner submitted servicing reports.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 20 August 2002 Resolved
Replace mounting brackett to portable fire extinguisher in galley.
Due 30 August 2002
Resolved 22 August 2002
Resolution: Mounting brackett replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 August 2002 Resolved
Provide light fixture guard in second compartment.
Due 30 August 2002
Resolved 22 August 2002
Resolution: Guard installed.
Lifesaving › Buoyant Apparatus
Issued 20 August 2002 Resolved
Provide spacers between lifefloats, mark w/ passenger capacity and name of vessel, attach one waterlight with minimum 18 foot of line to each lifefloat, and provide two oars with vessel's name to each float.
Due 30 August 2002
Resolved 22 August 2002
Communications › Radio Communications › EPIRB
Issued 20 August 2002 Resolved
Provide NOAA registration sticker for EPIRB.
Due 23 August 2002
Resolved 22 August 2002
Resolution: Registration stckier present.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 August 2002 Resolved
Remove all dead end wiring from pilot house, properly clamp suspended wires, and terminate all ends in j-boxes.
Due 30 August 2002
Resolved 22 August 2002
Engineering › Bilge Water Management System › Valve
Issued 20 August 2002 Resolved
Install positive stop closure valves to the rule submersible bilge pump overboard discharge hoses
Due 30 August 2002
Resolved 22 August 2002
Resolution: Valves installed.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 20 August 2002 Resolved
Properly clamp old shore tie connection box aft of wheelhouse.
Due 30 August 2002
Resolved 22 August 2002
Resolution: Connection box covered
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 20 August 2002 Resolved
Provide one B-I fire extinguisher for pilot house.
Due 23 August 2002
Resolved 22 August 2002
Resolution: Extinguisher placed onboard.
Documentation › Certificates/Documents
Issued 20 August 2002 Resolved
Provide a copy of the vessel's stability letter and place in pilot house. LEGACY COMPONENT DESC: Stability Letter
Due 30 August 2002
Resolved 18 August 2003
Resolution: Sighted stab letter for sister vessel, Andy Lynn IV.
Navigation › Piloting/Steering › Magnetic Compass
Issued 20 August 2002 Resolved
Ensure light to magnetic compass is operating. Vsl limited to daylight operations only.
Due 30 August 2002
Resolved 22 August 2002
Documentation › Markings/Placards
Issued 20 August 2002 Resolved
Provide emergency broadcast placard.
Due 30 August 2002
Resolved 22 August 2002
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 August 2002 Resolved
Replenish expired items from the first aid kit.
Due 30 August 2002
Resolved 22 August 2002
Documentation › Logs/Records
Issued 20 August 2002 Resolved
Ensure man overboard drills, fire drills, and monthly EPIRB tests are logged in a logbook. LEGACY COMPONENT DESC: Logbook (official)
Due 30 August 2002
Resolved 22 August 2002
Communications › Alarms/Indicators › High Water Alarm
Issued 20 August 2002 Resolved
Prove proper operation of high level alarms w/ visual/audible indicators for each compartment with through hull fittings.
Due 30 August 2002
Resolved 22 August 2002
Resolution: Vsl equipped with alarms for each compartment.
Operations/Management › Drills/Instruction
Issued 20 August 2002 Resolved
Vsl to conduct man overboard drills prior to carrying passengers with attending USCG marine inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 23 August 2002
Resolved 22 August 2002
Resolution: Vsl completed satisfactory man overboard recovery.
Lifesaving › Buoyant Apparatus
Issued 20 August 2002 Resolved
Reconfigure lifefloats so they are in a float free arrangement from the mast.
Due 30 August 2002
Resolved 22 August 2002
Resolution: Vsl owner reconfigured the lifefloats.
Stability › Freeing Ports
Issued 20 August 2002 Resolved
Provide plugs to the freeing ports to main deck aft entrance.
Due 30 August 2002
Resolved 22 August 2002
Engineering
Issued 22 August 2001 Resolved
Prove proper operation of port main engine prior to carrying passengers.
Condition: Unknown
Due 5 September 2001
Resolved 22 August 2002
Resolution: Verified proper operation of port main engine.
Accommodation/Occupational Safety
Issued 26 June 2001 Resolved
RENEW MSD VALVE PRIOR TO PLACING VESSEL BACK IN WATER.
Condition: Unknown
Due 29 June 2001
Resolved 16 July 2001
Construction/Loadline
Issued 26 June 2001 Resolved
PROVIDE LANYARDS FOR ALL WEATHERDECK HATCHES NLT 10JUL01.
Condition: Unknown
Due 29 June 2001
Resolved 16 July 2001
Construction/Loadline
Issued 26 June 2001 Resolved
RENEW VALVE FOR INSTALLED BILGE SYSTEM PRIOR TO PLACING VESSEL BACK IN WATER.
Condition: Unknown
Due 29 June 2001
Resolved 16 July 2001
Navigation
Issued 26 June 2001 Resolved
REPAIR CRACKED RUDDER PRIOR TO PLACING VESSEL BACK IN WATER.
Condition: Unknown
Due 29 June 2001
Resolved 16 July 2001
Construction/Loadline
Issued 26 June 2001 Resolved
PROVIDE OPERATING HANDLE FOR WASHDOWN SYSTEM VALVE PRIOR TO PLACING VESSEL BACK IN WATER.
Condition: Unknown
Due 29 June 2001
Resolved 16 July 2001
Lifesaving
Issued 26 June 2001 Resolved
PROPERLY ATTACH LIFE FLOATS TO PAINTER AND MAKE ALL LIFEFLOATS FLOAT FREE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 29 June 2001
Resolved 16 July 2001
Lifesaving
Issued 30 April 2001 Resolved
Properly post the life jacket donning placard
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Fire Fighting
Issued 30 April 2001 Resolved
Prove attestation of the servicing of the fixed firefighting system
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Lifesaving
Issued 30 April 2001 Resolved
The vessel is restricted to 56 total persons until the appropriate lifesaving equipment is provided
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Documentation
Issued 30 April 2001 Resolved
Provide documentation of enrollment in an approved drug and alcohol-testingprogram
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Lifesaving
Issued 30 April 2001 Resolved
Label the upper deck passengers
Condition: Unknown
Due 30 April 2001
Resolved 4 May 2001
Lifesaving
Issued 30 April 2001 Resolved
Properly label 10 adult lifejackets
Condition: Unknown
Due 30 April 2001
Resolved 4 May 2001
Documentation
Issued 30 April 2001 Resolved
Provide and post the original stability letter
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Lifesaving
Issued 30 April 2001 Resolved
Properly attach the 12-person lifefloat to the 22-person lifefloat
Condition: Unknown
Due 30 April 2001
Resolved 4 May 2001
Lifesaving
Issued 30 April 2001 Resolved
Replace the two paddles for the port 22-person lifefloat
Condition: Unknown
Due 30 April 2001
Resolved 4 May 2001
Lifesaving
Issued 30 April 2001 Resolved
Provide a waterlight for the 12-person life float
Condition: Unknown
Due 30 April 2001
Resolved 4 May 2001
Navigation
Issued 30 April 2001 Resolved
Provide up to date charts
Condition: Unknown
Due 30 April 2001
Resolved 4 May 2001
Navigation
Issued 30 April 2001 Resolved
Provide light list
Condition: Unknown
Due 30 April 2001
Resolved 4 May 2001
Navigation
Issued 30 April 2001 Resolved
Provide Coast Pilot
Condition: Unknown
Due 30 April 2001
Resolved 4 May 2001
Construction/Loadline
Issued 30 April 2001 Resolved
Provide leashes for the exposed deck hatches.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Lifesaving
Issued 8 May 2000 Resolved
PROVIDE DOCUMENTATION FOR BATTERY RENEWAL DATE FOR EPIRB.
Condition: Unknown
Due 15 May 2000
Resolved 18 May 2000
Electrical
Issued 8 May 2000 Resolved
PROVIDE A BRACKET FOR THE HEAT EXCHANGER FOR THE SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 15 May 2000
Resolved 18 May 2000
Lifesaving
Issued 21 June 1999 Resolved
PROVIDE LIFE JACKET LIGHT FOR EVERY ADULT AND CHILD PFD ABOARD VESSEL WHILEOPERATING ON VOYAGES GREATER THAN 20 MILES FROM A HARBOR OF SAFE REFUGE.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Construction/Loadline
Issued 14 June 1999 Resolved
BILGE ALARM FLOAT SWITCHES MOUNTED ON VERTICAL SURFACE VICE HORIZONTAL. PROPERLY MOUNT BILGE ALARM FLOAT AND PROVE PROPER OPEARTION. PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 14 June 1999
Resolved 14 June 1999
Construction/Loadline
Issued 14 June 1999 Resolved
HANDLE MISSING FROM THE FLUSH WATER SUCTION SEA VALVE. REATTACH HANDLE ANDPROVE PROPER OPERATION.
Condition: Unknown
Due 14 June 1999
Resolved 14 June 1999
Fire Fighting
Issued 14 June 1999 Resolved
REMOTE CABLE PULL FOR FIXED FIRE SYSTEM NOT CONNECTED AT THE CYLINDER HEAD.PROPERLY ATTACH CABLE PULL TO THE GAS CYLINDER. PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 14 June 1999
Resolved 14 June 1999
Accommodation/Occupational Safety
Issued 8 July 1997 Resolved
LABEL UPPER DECK CAPACITY IN VICINITY OF AFT LADDER.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Lifesaving
Issued 8 July 1997 Resolved
RENEW LINE ON FORWARD RING BUOY.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Construction/Loadline
Issued 8 July 1997 Resolved
LABEL BILGE MANIFOLD.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Engineering
Issued 8 July 1997 Resolved
RE-STENCIL FUEL SHUTOFF VALVE COVER PLATES.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Engineering
Issued 8 July 1997 Resolved
RENEW FUEL TANK VENT FLAME SCREEN.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Documentation
Issued 30 May 1996 Resolved
PROVIDE COPY OF PERMANENT FCC RADIOTELEPHONY CERTIFICATE WHEN RECEIVED FROMFCC.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Documentation
Issued 30 May 1996 Resolved
PROVIDE COPY OF DOCUMENT WITH RENEWAL DECAL AFFIXED WHEN RECEIVED FROM VESSEL DOCUMENTATION CENTER.
Condition: Unknown
Due 24 June 1996
Resolved 1 July 1996
Lifesaving
Issued 16 May 1995 Resolved
STENCIL VESSEL'S NAME ON BOTH RING BUOYS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 June 1995
Resolved 10 July 1995
Electrical
Issued 16 May 1995 Resolved
PERMANENTLY MOUNT ELECTRICAL PLUG IN GALLEY.
Condition: Unknown
Due 16 June 1995
Resolved 10 July 1995
Electrical
Issued 16 May 1995 Resolved
PROPERLY SPLICE WIRES UNDER CONSOLE IN PILOT HOUSE.
Condition: Unknown
Due 10 July 1995
Resolved 10 July 1995
Engineering
Issued 16 May 1995 Resolved
INSTALL MACHINERY GUARD ON STARBOARD MAIN ENGINE BELTS.
Condition: Unknown
Due 16 June 1995
Resolved 10 July 1995
Construction/Loadline
Issued 20 April 1995 Resolved
PROVIDE PROPER BULKHEAD PENETRATION FOR WATER PUMP PIPING IN BULKHEAD BETWEEN STEERING GEAR ROOM AND TANK ROOM
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Engineering
Issued 20 April 1995 Resolved
PROVIDE TOOL TO OPEN CAP COVERING FUEL OIL SHUT OFF VALVES
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Lifesaving
Issued 20 April 1995 Resolved
PROPERLY MOUNT LIFE FLOAT WATER LIGHT
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Lifesaving
Issued 20 April 1995 Resolved
PROVIDE APPROVED LIGHTS LIGHTS ON CHILD PFDs _x001C_ _x001C_ _x001C_ NO CHILDREN ALLOWED ON OCEANS ROUTE UNTIL CORRECTED
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Lifesaving
Issued 20 April 1995 Resolved
PROVIDE APPROVED RING BUOY
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Electrical
Issued 20 April 1995 Resolved
PLUG OPENINGS IN DECK LIGHT FIXTURES
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Lifesaving
Issued 20 April 1995 Resolved
PROVIDE ADDITIONAL RING BUOY WITH LIGHT AND LINE_x001C_ _x001C_ VESSEL RESTRICTED TO NOT MORE THAN 59 PERSONS ON OCEAN ROUTE UNTIL CORRECTED
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Lifesaving
Issued 20 April 1995 Resolved
PROVIDE EPIRB_x001C_ _x001C_ VESSEL RESTRICTED TO NOT MORE THAN 20 MILES FROM HARBOR OF SAFE REFUGE UNTIL CORRECTED.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Navigation
Issued 20 April 1995 Resolved
PROVIDE SINGLE SIDE BAND RADIO_x001C_ _x001C_ VESSEL RESTRICTED TO NOT MORE THAN 20 MILES FROM HARBOR OF SAFE REFUGE UNTIL CORRECTED
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Documentation
Issued 20 April 1995 Resolved
PROVIDE FCC SAFETY CERTIFICATE
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995

Casualty record · 3

2 August 2020Routine · role: Involved in a Marine Casualty · activity 7023447
7 July 2021Routine · role: Involved in a Marine Casualty · activity 7248266
10 September 2024Routine · role: Involved in a Marine Casualty · activity 8005831
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

YANKEE PATRIOT II (2020–2021), SEACOAST LADY (2024). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.