Records from 1993 to 2009. Most recent: inspection, 8 February 2009.
Inspection history · 74
8 February 2009
COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3403877
4 January 2009
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3388287
24 September 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3331537
20 August 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3303850
6 August 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3291154
24 June 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3247161
4 June 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3227578
23 May 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3214454
23 May 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3214555
28 December 2007
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3121853
28 December 2007
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3122132
17 September 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3059959
26 April 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2916440
19 April 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2911081
11 March 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2885823
5 January 2007
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2852108
10 August 2006
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2754891
7 January 2006
MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2560738
20 October 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2521388
14 September 2005
ISPS III Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2492586
23 July 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2437248
22 July 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2437243
22 July 2005
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2476260
17 July 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2429209
14 April 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2364283
10 January 2005
COC-TVE Annual
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2272260
15 December 2004
Random ISPS/MTSA/PSC
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2260313
28 July 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2148476
28 July 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2164029
10 July 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2128044
11 May 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2065260
10 May 2004
MTSA/ISPS Verification · Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2064547
5 April 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2041613
9 January 2004
Certificate of Compliance · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1980114
8 September 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1904442
19 June 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1822328
24 May 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1802234
22 May 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1799150
18 May 2003
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1794436
23 January 2003
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1734386
8 January 2003
Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1726366
10 December 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1718125
14 August 2002
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1643955
24 January 2002
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1480950
10 January 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 285869
25 September 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 282357
7 January 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 273463
29 December 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 481097
8 January 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 424314
24 August 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 111741
24 August 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 419903
11 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 66755
11 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 204057
11 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 768827
29 January 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 412224
28 October 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 503800
8 February 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 400251
21 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 130034
24 February 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 388183
27 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 375868
7 February 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 457241
20 October 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 692116
9 October 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 151101
22 August 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 63658
22 August 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 185273
15 April 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1167664
30 March 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422351
13 March 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 452165
13 March 1994
Tank Vessel Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 854707
5 February 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 364271
30 September 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 474413
10 March 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 356832
6 March 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 356654
6 March 1993
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 838309
Deck/Cargo › Mooring/Anchoring › Winch
Issued 20 August 2008
Resolved
On 20AUG08 the Captain of the Port United States Coast Guard Sector Houston/Galveston received a report that your vessel's starboard anchor windlass was inoperable.
Prior to departure the vessel is required to provide a report from class attesting to the proper operation of the starboard anchor windlass.
On 23AUG08 received condition of class stating 22NOV08 it has to be fixed.
Condition: Unknown
Due 22 November 2008
Resolved 24 September 2008
Resolution: Cleared by class (DNV) report.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 January 2006
Resolved
Temporary wiring not properly installed in berthing areas. Wiring spliced from outlets unsafe.
Condition: Placed in Improper Service
Due 7 January 2006
Resolved 7 January 2006
Fire Fighting › Nozzles › Condition
Issued 7 January 2006
Resolved
Nozzle gasket fell out when hose was checked.
Condition: Improper/Lack of Maintenance
Due 7 January 2006
Resolved 7 January 2006
Fire Fighting › Fire Pumps › Arrangement
Issued 7 January 2006
Resolved
Leak on NO. 1 cool F.W. pump. Must be fixed prior to the next U.S. port after sailing foriegn to the satisfaction of the Coast Guard.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 August 2006
Resolution: Received class survey report verifying rectification.
Engineering › Lubricating Oil Storage/Transfer System › Drain Tank
Issued 7 January 2006
Resolved
Generators have clogged drain lines. Lubricating oil is driping into buckets below. Must be fixed prior to next U.S. port after sailing foriegn to the satisfaction of the coast guard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 August 2006
Resolution: Received class survey report verifying rectification.
Deck/Cargo › Ballast › Piping
Issued 7 January 2006
Resolved
Temprary patches on balast overboard discharge.
Action required: 705 - Other - as specified
Due 6 February 2006
Resolved 10 August 2006
Resolution: Received class survey report verifying rectification.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 7 January 2006
Resolved
Repair sight galss dreain fitting on deck seal.
Due 7 January 2006
Resolved 7 January 2006
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 7 January 2006
Resolved
2 patches on the deck seal overboard located in the pump room.
Action required: 705 - Other - as specified
Due 6 February 2006
Resolved 10 August 2006
Resolution: Received class survey report verifying rectification.
Construction/Loadline › Markings
Issued 9 January 2004
Resolved
LOADLINE NOT PAINTED IN CONTRASTING COLOR AS REQUIRED. ILLC 66 ANNEX 1/9 LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2004
Electrical › Electric Supply System (service)
Issued 9 January 2004
Resolved
GROUNDING WIRES IN VACINITY OF #2 CARGO TANK ARE NOT GROUNDED AND INTRODUCE AN EXPLOSION HAZARD. SOLAS 74/78 CH II-1 REG 45.5.4 LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2004
Fire Fighting › Firemans Outfit
Issued 8 January 2003
Resolved
One fire suit(stored in steering) has damaged insulation and in need of replacement. Provide for proper replacement prior to 25JAN03. SOLAS 74(Amended) Chp.II-2 Reg. 17 LEGACY COMPONENT DESC: Protective Clothing
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 January 2003
Resolved 23 January 2003
Resolution: Correct deficiency via facsimile from vessel''s class - BV.
Engineering › Steam System (main)
Issued 8 January 2003
Resolved
Steam leak on valve in excessive steam dumpline. SOLAS 74(Amended) Chp. II-1 Reg. 33 Item to be repaired to the satisfaction of class no later than 01MAR03. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2003
Resolved 23 January 2003
Resolution: Corrected deficiency via facsimile from vessel''s class - BV
Engineering
Issued 10 January 2001
Resolved
Vessel missing remote shut off valve to the fuel oil supply line from the emergency generator day tank iaw SOLAS 74/78(AMD) II-2/15.2.5.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Construction/Loadline
Issued 24 August 1998
Resolved
REPAIR TO THE THE SATISFACTION OF, AND HAVE CLASS ATTEST TO THE STRUCTURAL INTEGRITY OF THE PORT BOW DUE TO THE 30 FT X 20 FT INSET. CLASS REPORT TO BE FAXED TO THIS OFFICE NO LATER THAN 31AUG98. NOTE: CLASS SURVEY RECIVED, NO STRUCTURAL CONCERNS REPORTED.
Condition: Unknown
Due 31 August 1998
Resolved 31 August 1998
Deck/Cargo
Issued 13 March 1994
Resolved
PRIOR TO UTILIZING VALOR CONTROL SYSTEM IN U.S. WATERS, SHOW PROPER OPERATION OF #5 CARGO TANK OVERFILE & HI LEVEL ALARMS TO THE SATISFACTION OF CG MARINE INSPECTOR, NLT 13JUN94.
Condition: Unknown
Due 13 March 1994
Resolved 13 March 1994
Navigation
Issued 6 March 1993
Resolved
A VIO OF 33 CFR 164.33 IN THAT THE B.A. LIGHT LIST VOL J USED BY THE VSL WAS NOT CORRECTED TO NTM 06/93 WHICH WAS REASONABLY AVAILABLE AND CONTAINEDCORRECTIONS APPLICABLE TO THE VSLS ROUTE FROM CAPE HENLOPEN, DE TO WESTVILLE, NJ.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Navigation
Issued 6 March 1993
Resolved
A VIO OF 33 CFR 164.33 IN THAT B.A. CHARTS 2563, AND 2564 USED BY THE VSL WERE NOT CORRECTED TO NTM 06/93 WHICH WAS REASONABLY AVAILABLE AND_x001C_ CONTAINED CORRECTIONS APPLICABLE TO THE VSLS ROUTE FROM CAPE HENLOPEN, DE TO WESTVILLE, NJ.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993