Records from 1981 to 2019. Most recent: inspection, 5 August 2019.
Inspection history · 92
5 August 2019
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6776187
23 February 2019
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6631797
23 July 2015
Type not recorded
No type recorded · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5197533
17 March 2012
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4266828
13 December 2010
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3910025
13 December 2010
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3910311
12 July 2010
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3801792
30 January 2006
Administrative Inspection
Administrative · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2578315
3 February 2005
MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2286338
20 February 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2010008
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978909
2 October 2003
Examination of Repairs
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1919818
25 April 2003
Internal Structural Exam · Periodic Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1780456
31 March 2003
Administrative Inspection
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1765928
7 October 2002
Examination of Repairs
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1701278
10 June 2002
Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1628797
13 June 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1070638
2 April 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 134557
26 January 2001
Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1057842
26 January 2001
Administrative
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1058376
20 July 2000
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 42741
15 May 2000
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 820172
15 May 2000
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 820180
20 April 2000
Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1462079
19 April 2000
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 107675
19 April 2000
Administrative
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1048498
6 April 2000
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 530565
27 March 2000
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1433624
27 August 1999
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 478389
4 May 1999
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1360845
5 December 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 803834
17 July 1998
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1129482
27 March 1998
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1447811
25 March 1998
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1434702
7 July 1997
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1113558
27 January 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 118320
26 July 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1088704
9 July 1996
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1092983
21 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 130034
21 June 1996
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367808
3 May 1996
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1083303
28 December 1995
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1185098
27 November 1995
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 882505
17 October 1995
Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1184540
24 May 1995
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1184622
16 March 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 521711
12 August 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1175307
20 May 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1387542
6 February 1994
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3191
24 December 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358260
14 December 1993
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1397997
16 November 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 166319
8 November 1993
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 848392
5 November 1993
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 848161
21 May 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1443376
13 January 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 828347
6 December 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 537023
21 November 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 529139
5 November 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 117640
29 September 1992
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1244869
26 September 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 949264
19 May 1992
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473564
9 March 1992
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 943693
22 August 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 436624
20 March 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 474252
30 January 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1221424
16 January 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 483748
19 November 1990
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 476425
13 September 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 494421
19 March 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 924250
17 January 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1211315
20 November 1989
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 532724
1 May 1989
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 471269
3 February 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1196814
17 November 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1204194
16 March 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029122
2 March 1988
MARPOL Annex II Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1333745
11 February 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 486876
11 February 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1331080
23 July 1987
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 527511
15 April 1987
Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1324912
18 February 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 489211
14 November 1986
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1324213
11 September 1986
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 516029
9 September 1986
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 478763
3 January 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996953
11 April 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 981600
28 February 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 300734
13 March 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 973234
11 June 1982
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 971354
9 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272178
22 April 1981
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1278827
Construction/Loadline › Hull › Side Shell
Issued 13 December 2010
Resolved
Vessel had failed temporary patches (shingles) in wing voids #3, #4, and the stern void. Damage most likley caused from ice damage.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2010
Resolution: Crew used old PFDs stuffed over the holes, braced with 4x4''s and hydraulic jacks against interior framing.
Construction/Loadline
Issued 27 March 2000
Resolved
Make permanent proper repair to fracture in way of port sheer strake/ deck knuckle approximately 25 feet aft of bow.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Construction/Loadline
Issued 7 July 1997
Resolved
BARGE HAS BEEN GRANTED NON-GAS-FREE LAYUP STATUS. PRIOR TO RETURNING BARGETO SERVICE, COMPLETE ALL REQUIRED HULL EXAMS.
Condition: Unknown
Due 7 July 1997
Resolved 7 July 1997
Construction/Loadline
Issued 21 June 1996
Resolved
INSTALL TEMPORARY REPAIRS TO BOTH KNOWN HOLES, TO STOP OR SIGNIFICANTLY REDUCE WATER FROM LEAKING INTO #2 STBD WING VOID.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Unknown
Issued 21 June 1996
Resolved
VESSEL REPRESENTATIVES WILL INFORM THE USCG AS TO BARGE'S REPAIR DESTINATION TO CONDUCT A BETTER DAMAGE SURVEY AND TO EFFECT PERMANENT REPAIRS. VESSEL WILL NOT CONDUCT ANY OTHER CARGO OPERATIONS UNTIL PERMANENT REPAIRS ARE SATISFACTORY WITNESSED BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Deck/Cargo
Issued 21 June 1996
Resolved
VESSEL IS TO PROCEED TO EXXON REFINERY, B.R., LA (VESSEL ORIGNAL DESTINATION) AND OFF-LOAD ALL CARGO. CONDUCT NO OTHER CARGO OPERATION.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Unknown
Issued 21 June 1996
Resolved
VESSEL REPRESENTATIVES WILL INFORM THE LOCAL USCG DETACHMENT AT (504) 389- 0271 WHEN ITEMS NO. 01 & 02 ARE COMPLETED.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Deck/Cargo
Issued 27 November 1995
Resolved
PRIOR TO USING, PROVIDE LOCAL OCMI WITH APPROVAL FOR THE INSTALLATION OF DECK SLOP TANK AND CARGO P.R.I.S. FOR CARGOES ACCEPTABLE FOR CARRIAGE IN THE SLOP TANK.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Deck/Cargo
Issued 27 November 1995
Resolved
PRIOR TO USING STRIPPING SYSTEM PROVIDE LOCAL OCMI WITH USCG MARINE SAFETY CENTER APPROVAL LETTER AND PLANS.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Construction/Loadline
Issued 17 October 1995
Resolved
CROP OUT AND RENEW DETERIORATED BOTTOM SECTION OF RAISED TRUNK BRACKET ON FOWARD PORTSIDE TO SATISFACTION TO CG INSPECTOR.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Construction/Loadline
Issued 17 October 1995
Resolved
REPAIR RAISED TRUNK BRACKET BETWEEN #3 AND #4 PORT WING VOID TO SATISFACTION OF LOCAL CG INSPECTOR.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Deck/Cargo
Issued 17 October 1995
Resolved
PRIOR TO LOADING CARGO RENEW REACHRODS AND PACKING TO #1 & #2 CARGO TANK VALVES TO THE SATISFACTION OF HOUMS CG INSPECTOR.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Deck/Cargo
Issued 17 October 1995
Resolved
REPLACE MISSING CAP BOLT ON #2 CARGO TANK PV VALVE TO THE SATISFACTION OF LOCAL CG INSPECTOR.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Construction/Loadline
Issued 17 October 1995
Resolved
REWNEW BUTTONS PORT & STBD AFT VOID TO SATISFACTION OF LOCAL CG INSPECTOR.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Deck/Cargo
Issued 17 October 1995
Resolved
HYDROSTATICALLY TEST STEAM HEATING PIPING.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Deck/Cargo
Issued 17 October 1995
Resolved
PROIR TO LOADING CARGO MAKE REPAIR TO PORT & STBD AFT WINCH BRAKES AND DEMONSTRATE OPERATION TO SATISFACTION OF LOCAL CG INSPECTOR.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Construction/Loadline
Issued 17 October 1995
Resolved
RENEW SIX FEET OT GUN WALE FORWARD OF AFT MOST STBD KEVEL TO SATISFACTION OF LOCAL CG INSPECTOR.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Construction/Loadline
Issued 17 October 1995
Resolved
REPLACE GASKET ALL WING VOID AS NEEDED TO SATISFACTION OF LOCAL CG INSPECTOR.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Construction/Loadline
Issued 17 October 1995
Resolved
RENEW GUNWALE AREA IN WAJ IN WAY OF #1 STBD WING VOID TO STISFACTION OF LOCAL CG INSPECTOR
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Construction/Loadline
Issued 17 October 1995
Resolved
REPAIR CRACKED GUNWALE IN WAY OF FORWARD VOID STBD SIDE ( 2 FT. OF BUTTON) TO SATISFACTION OF LOCAL CG INSPECTOR.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Construction/Loadline
Issued 17 October 1995
Resolved
TO ENTIFY AND RENEW ALL DETERIORATED TRUNK LONGITUDE TO SATISFACTION OF LOCAL CG INSPECTOR
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Construction/Loadline
Issued 14 December 1993
Resolved
PROCEDE TO KOCH OIL DOCK ST. JAMES LA TO DISCHARGE CARGO. MAKE PERMANENT REPAIRS IN WAY OF AFT PORT DECK CLEAT. MAKE AFT PORT WING VOID ACCESIBLE FOR INTERNAL INSPECTION. BARGE NOT TO LEAVE MSO NEW ORLEANS INSPECTION ZONEWITHOUT PRIOR APPROVAL FROM [name withheld].
Condition: Unknown
Due 14 December 1993
Resolved 14 December 1993
Construction/Loadline
Issued 5 November 1993
Resolved
OFFLOAD PRESENT CARGO AND PRIOR TO LOADING ANY OTHER CARGO, PROCEED TO SBA SHIPYARD, JENNINGS, LA TO LOCATE AND MAKE PERMENANT REPAIRS TO THE HOLE IN THE #1 WING VOID. REPAIRS SHALL BE MADE TO THE SATISFACTION OF AN ATTENDINGCOAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 December 1993
Resolved 2 December 1993
Construction/Loadline
Issued 29 September 1992
Resolved
TEMPORARILY REPAIR HOLE AT BASE OF VENT PIPE FOR #2 WING VOID. MAKE PERMANENT REPAIR AT NEXT GAS FREEING OF BARGE OR AT THE NEXT CARGO TANK INTERNAL EXAM
Condition: Unknown
Due 29 September 1992
Resolved 29 September 1992
Construction/Loadline
Issued 29 September 1992
Resolved
TEMPORARILY REPAIR 2" CRACK IN WAY OF HEAD LOG BRAKET ON STBD SIDE OF OF BOW. MAKE PERMANENT REPAIR NEXT GAS FREEING OF BARGE OR NEXT CARGO TANK EXAM.
Condition: Unknown
Due 29 September 1992
Resolved 29 September 1992
Construction/Loadline
Issued 26 September 1992
Resolved
MAKE GAS FREE FOR INSPECTION BOW RAKE AND #'S 1 & 2 PORT WING VOIDS DUE TO GROUNDING ON 26 SEP 1992.
Condition: Unknown
Due 26 September 1992
Resolved 26 September 1992
Construction/Loadline
Issued 3 February 1989
Resolved
CROP & RENEW APPROX 7 FT OF SET-IN BILGE KNUCKLE, DAMAGED INTERNAL FRAMING,AND ADJACENT SET-IN BOTTOM PLATE APPROX 03 FT INBOARD OF DAMAGED KNUCKLE ONTHE PORT SIDE OF BOW RAKE APPROX 08 FT AFT OF HEADLOG TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 3 February 1989
Resolved 3 February 1989
Construction/Loadline
Issued 11 February 1988
Resolved
DEWATER THE BOW-VOID AND PRESENT FOR INTERNAL INSPECTION AND REPORT OF DAMAGE. THIS ITEM IS TO BE COMPLETED PRIOR TO LOADING NEXT VSL CARGO BUT NOT LATER THAN 11MAR88.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Deck/Cargo
Issued 11 February 1988
Resolved
MODIFY CONTAINMENT DRIP PANS TO FACILITATE CONNECTIONS BEING MADE ABOVE "OPEN" CONTAINMENT
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988