Inspection history · 26
12 February 2026
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8317106
16 March 2025
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8094438
21 December 2023
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7839086
20 October 2023
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7812893
15 November 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7595034
22 October 2021
Annual Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7339428
10 September 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7055160
17 February 2020
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6911468
16 October 2019
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6843476
23 February 2019
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6631797
21 January 2019
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6613202
22 August 2018
Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6505056
28 March 2018
MTSA Verification · Administration · Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6380610
8 December 2017
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6321282
5 October 2017
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6281935
7 October 2012
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4460413
2 October 2012
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4455545
2 October 2012
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4455661
12 June 2012
Industry Initiated Exam · MTSA Verification · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4342915
25 July 2006
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2724398
25 April 2006
MTSA Verification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2787116
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968381
10 April 2002
Uninspected Towing Vessel
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1607536
10 April 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1611036
2 November 2000
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 283899
16 November 1999
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 435610
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 February 2026
Resolved
143.230 Alarms and monitoring.
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (5) High bilge levels; Alarms must:
(1) Be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location;
Visible and audible alarm for high bilge level is not at the operating station. Install visible and audible alarm in the wheelhouse and label appropriately.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2026
Resolved 24 March 2026
Resolution: Received video/pictures of new audible/visual alarm installation at the operating station. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 25 February 2026
Resolved
140.505 General health and safety requirements.
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. This includes machinery, deck machinery, towing gear, ladders, embarkation devices, cranes, portable tools, and
safety equipment.
Deck grating outside of wheelhouse is corroded and damaged. Temporary deck grating has been placed atop making the area safe to transit. Make permanent repairs to deck grating as soon as operations permit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2026
Resolved 24 March 2026
Resolution: Corroded deck grating has been removed and replaced via permanent repairs. All sat.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 21 December 2023
Resolved
Each towing vessel must be fitted with a general alarm that has a supplemental flashing red light. The vessel had a constant red light in the engine room next to the general alarm signage. Replace the light with a flashing light to the satisfaction of the attending marine inspector.
46 CFR 143.235(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2024
Resolved 11 January 2024
Resolution: Vessel rep provided video evidence of red flashing light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 December 2023
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. The generator switchboard lacked proper labeling. Label the switchboard to indicate what generator is running.
46 CFR 143.400(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2024
Resolved 11 January 2024
Resolution: Vessel rep provided objective evidence for switchboard labeling.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 December 2023
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. The distribution panel in the engine room was not label and did not indicate what loads it carried. Label the distribution panel to reflect what each breaker serves.
46 CFR 143.400(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2024
Resolved 11 January 2024
Resolution: Vessel rep provided objective evidence of electrical panel labeling.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 December 2023
Resolved
Pressure vessel relief valves must be tested twice every 5 years with no mare than 3 years elapsing since last test. There was no record of the last test for the air start pressure vessels. Replace or test the relief valves to the satisfaction of the attending marine inspector.
46 CFR Table 143.245(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2024
Resolved 11 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 December 2023
Resolved
Electrical components that pose an electrical hazard must in an enclosure. Provide proper enclosure for the deck receptacle to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2024
Resolved 11 January 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 November 2022
Resolved
EACH TOWING VESSEL MUST BE MAINTAINED AND OPERATED SO AS TO MINIMIZE FIRE HAZARDS AND TO ENSURE THE FOLLOWING: (A) ALL BILGES AND VOID SPACES ARE KEPT FREE FROM ACCUMULATION OF COMBUSTIBLE AND FLAMMABLE MATERIALS AND LIQUIDS INSOFAR AS PRACTICABLE.
ENGINE ROOM BILGE CONTAINS EXCESS FUEL OIL.
REMOVE ALL EXCESS FUEL OIL FROM ENGINE ROOM BILGE.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 November 2022
Resolution: Bilges cleaned; no fuel or oil present throughout engine room.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 November 2022
Resolved
EACH TOWING VESSEL MUST BE MAINTAINED AND OPERATED SO AS TO MINIMIZE FIRE HAZARDS.
STARBOARD FUEL TANK STRIPPING VALVE & FITTING IS LEAKING FUEL INTO ENGINE ROOM.
REPAIR/RENEW LEAKING FUEL STRIPPING VALVE/FITTING ASSEMBLY.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 November 2022
Resolution: STBD fuel tank stripping valve and associated piping renewed; valve is secured with no apparent leaks.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 21 November 2022
Resolved
THE INSPECTION WILL ENSURE THAT THE VESSEL IS IN SATISFACTORY CONDITION AND FIT FOR THE SERVICE FOR WHICH IT IS INTENDED; WILL INCLUDE INSPECTIONS OF THE STRUCTURE.
FOUND CRACK ON PORT, AFT ENGINE ROOM BULKHEAD AGAINST PORT, AFT VOID.
PUMP OUT AND CLEAN PORT, AFT VOID. ENSURE SPACES ARE CLEARED BY MARINE CHEMIST TO ALLOW MARINE INSPECTORS TO CONDUCT AN INTERNAL EXAM OF VOID PRIOR TO REPAIRS.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 November 2022
Resolution: Aft void and engine room gas-freed by MC. Crack welded by qualified shipyard welder. Dye-pen leak through test conducted; satisfactory results.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 21 November 2022
Resolved
AN EXPOSED HAZARD SUCH AS GEARS AND ROTATING MACHINERY, MUST BE PROTECTED BY A COVER, GUARD OR RAIL.
FOUND EXPOSED BELT DRIVE ON PORT AND STARBOARD GENERATORS.
INSTALL GUARD OR COVER OVER BELT DRIVE ASSEMBLY.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 November 2022
Resolution: Guards installed on port and starboard generator over drive belt assembly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 November 2022
Resolved
CLOSURE DEVICES MUST BE PROVIDED FOR DECKHOUSE OR HULL
PENETRATIONS, WHICH OPEN TO THE EXTERIOR OF THE VESSEL AND WHICH MAY ALLOW WATER TO ENTER THE VESSEL.
PORT, AFT VOID HATCH MISSING INTERIOR DOG ASSEMBLY; LOSS OF WATERTIGHT INTEGRITY TO VOID.
RENEW DOG ASSEMBLY TO ALLOW PROPER OPERATION OF CLOSURE DEVICE.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 November 2022
Resolution: Dog assembly renewed on aft void hatch and is now watertight when secured.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 November 2022
Resolved
EACH TOWING VESSEL MUST BE MAINTAINED AND OPERATED SO AS TO MINIMIZE FIRE HAZARDS.
FOUND SEVERE CHAFFING ON STARBOARD STEERING PUMP DISCHARGE HOSE ASSEMBLY.
RENEW STEERING PUMP DISCHARGE HOSE; ADD CHAFFING GEAR TO HOSE OR RE-ROUTE HOSE TO AVOID FUTURE CHAFFING.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 30 November 2022
Resolution: Steering pump discharge hose renewed; chaffing gear installed to prevent future wear.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 November 2022
Resolved
RAILS OR EQUIVALENT PROTECTION MUST BE INSTALLED NEAR THE PERIPHERY OF ALL DECKS ACCESSIBLE TO CREW. EQUIVALENT PROTECTION MAY INCLUDE LIFELINES, WIRE ROPE, CHAINS AND BULWARKS THAT PROVIDE STRENGTH AND SUPPORT EQUIVALENT TO FIXED RAILS.
VESSEL DOES NOT HAVE HAND RAILS SURROUNDING USABLE DECK SPACE.
INSTALL HAND RAILS, OR EQUIVALENT, ON ALL PRACTICABLE AREAS SURROUNDING MAIN DECK.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 14 December 2022
Resolution: Installed new stanchions and double lines encompassing work area around vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2022
Resolved
ELECTRICAL COMPONENTS THAT POSE AN ELECTRICAL HAZARD MUST BE IN AN ENCLOSURE.
FOUND EXPOSED ELECTRICAL CONNECTIONS ON SHIP'S HORN DEVICE ON TOP OF WHEELHOUSE, HEATER FAN INSIDE OF WHEELHOUSE AND AN EXPOSED OUTLET IN GALLEY/OFFICE AREA IN DECK BELOW WHEELHOUSE.
SECURE ALL ELECTRICAL CONNECTIONS IN AN ENCLOSURE AND INSTALL PROTECTIVE COVER AROUND ELECTRICAL OUTLET.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 30 November 2022
Resolution: Heater in wheelhouse removed and cover install over opening to correct electrical hazard. Ship's horn wiring has been soldered and heat shrunk to prevent corrosion and electrical hazard. Electrical outlet cover renewed in galley area.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 21 November 2022
Resolved
A CREW ACCOMODATION SPACE AND A WORK SPACE MUST BE OF SUFFICIENT SIZE, ADEQUATE CONSTRUCTION AND WITH SUITABLE EQUIPMENT TO PROVIDE ACCOMODATION OF THE CREW IN A MANNER PRACTICABLE FOR THE SIZE, FACILIES, SERVICE, ROUTE AND MODES OF OPERATION OF THE VESSEL.
MAKE-SHIFT TOILET/BUCKET IN ENGINE ROOM NOT ADEQUATE ACCOMODATION FOR SANITARY FACILITIES FOR INTENDED WORKING CONDITIONS.
PROVIDE A PORTABLE MARINE TOILET TO ACCOMODATE NEEDS OF THE CREW.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 14 December 2022
Resolution: Purchased a portable marine toilet and placed on vessel for future use.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 22 April 2002
Resolved
Vessel did not have the require number of portable fire extinguishers onboard as required by 46 CFR 25.30-20
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 April 2002
Resolved 22 April 2002
Resolution: Fire extinguishers were serviced on the spot giving them the required number onboard
Communications › Alarms/Indicators › General Alarm
Issued 22 April 2002
Resolved
Red flashing light in the engine room for the general alarm was missing as required by 46
cfr 27.205(a)(3)
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 24 April 2006
Resolution: OVERDUE CORRECTION/ MISLE MAINTENANCE
Operations/Management › Drills/Instruction › Fire
Issued 22 April 2002
Resolved
Required drills not taking place onboard the vessel as required by 46 CFR 27.355(a)
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 24 April 2006
Resolution: OVERDUE CORRECTION/ MISLE MAINTENANCE
Operations/Management › Drills/Instruction › Fire
Issued 22 April 2002
Resolved
Participation in drills does not meet requirements in 46 CFR 27.355(c)
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 24 April 2006
Resolution: OVERDUE CORRECTION/ MISLE MAINTENANCE
Communications › Audible Communications › Bell
Issued 22 April 2002
Resolved
Vessel did not have a fog bell as required by 33 USC 2033
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 24 April 2006
Resolution: OVERDUE CORRECTION/ MISLE MAINTENANCE
Navigation › Piloting/Steering › Magnetic Compass
Issued 22 April 2002
Resolved
Vessel did not have a swing meter or compass onboard as required by 33 CFR 164.72(a)(4)(i)
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 24 April 2006
Resolution: OVERDUE CORRECTION/ MISLE MAINTENANCE
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 22 April 2002
Resolved
No portable fire extinguisher in the engine room as required by 46 CFR 25.30-20(b)(2)(i)
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 April 2002
Resolved 22 April 2002
Resolution: Fire extinquisher was placed onboard before we left the scene.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 22 April 2002
Resolved
Vessel did not have a certification letter for the fire detection system that was installed on the vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 24 April 2006
Resolution: OVERDUE CORRECTION/ MISLE MAINTENANCE