MAURY USCG vessel records
← All vessels

JAMES T

JAMES T is a 2007 towing vessel. The Coast Guard has recorded 17 inspections since 2010, most recently in March 2026, along with 7 deficiencies and 6 casualty investigations between 2011 and 2026.

Records from 2010 to 2026. Most recent: inspection, 5 March 2026.

Built
2007
Last inspected
5 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 5 March 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2010–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF4835
896743
Flag
UNITED STATES
Maury page id
psix-896743

Documentation record

Registered dimensions (L × B × D)67.2 ft × 26.0 ft × 9.0 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)67.2 ft × 26.0 ft × 9.0 ft
ITC tonnageNot recorded
BuilderNICHOLS BOAT COMPANY · GREENVILLE, MS, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMEMPHIS, TN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 March 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 11

Inspection history · 17

5 March 2026 Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8320317
2 February 2026 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8325132
13 February 2025 COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8079183
11 April 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7893557
11 March 2024 Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7877396
15 February 2023 Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7637301
14 December 2022 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7609462
28 March 2022 Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7419963
24 March 2021 Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7169778
19 February 2020 Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6911696
17 February 2020 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6911468
15 November 2016 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6041473
31 May 2013 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4624206
20 March 2011 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3975000
18 March 2011 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3967431
3 March 2011 Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3956545
8 June 2010 Administration · Industry Initiated Exam · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3761878

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 February 2023 Resolved
Paints, coatings and other flammable or combustible products must be stored in a designated storage room or cabinet. If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not not move and must be either: Meet UL 1275 Standards Meet FM approval Standard 6050 or, Another steel container that provides equivalent level of protection. Flammable and combustible liquids are being stored in starboard push knee. Push knees are completely open to atmosphere. Current storage arrangements do not provide equivalent level of safety.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2023
Resolution: Installed UL approved flam locker.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 15 February 2023 Resolved
A navigation assessment entry must be recorded in the vessel log book. The entry must include the date and time of assessment, the name of individual making assessment, and the starting and ending points of the voyage or trip that the assessment covers. There are no logs indicating that navigation assessments are being conducted. Provide objective evidence that person in charge of the navigation watch is conducting navigation inspections in accordance with all requirements listed in 46 CFR 140.635.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2023
Resolution: Operator provided several days of vessel logs showing nav assessments are being completed
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 15 February 2023 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to the crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed railed. Aft deck does not have any fall overboard protection. Install stanchion and chain system as discussed with Marine Inspector. If a different system than discussed is going to be installed, contact Marine Inspector for approval prior to its instillation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2023
Resolution: Installed stanchion and cable system.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 15 February 2023 Resolved
Each towing vessel must be equipped with the following alarms: Maine engine and generator engine high cooling water temperature. Main engine and generator engine low lube oil pressure alarm. High bilge level alarm. Low hydraulic steering fluid level alarm. Low fuel level alarm if fitted with a day tank. Additionally, in accordance with table 143.245(b), alarm set points must be tested twice every 5 years, with no more than 3 years elapsing since last testing. Crew was unable to test generator alarm set points or steering fluid level alarm.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2023
Resolution: Tested alarms. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 February 2023 Resolved
46 CFR 141.340 Each life jacket must have a light approved under under approval series 161.012 or 161.112 securely attached to front shoulder area of life jackets. Life jacket must be removed from service until it can be fitted with light. Vessel is limited to carrying no more than 07 total persons until life jacket is placed back into service. 46 CFR 140.430: When worn at night, work vest must be equipped with light that meets requirements of 141.340. Found 04 work vest without lights. Work vest must not be worn at night until equipped with approved lights.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2023
Resolved 14 March 2023
Resolution: Received copy of purchase receipts for life jacket lights and photo showing lights attached to life jacket and work vest.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 22 April 2022 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Engine room bilge high level alarm inoperable. Vessel is authorized to continue to operate with hourly engine room rounds being made by the crew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 26 April 2022
Resolution: Engine room bilge high level alarm replaced and tested satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 April 2022 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Replace broken light covers in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 26 April 2022
Resolution: Light covers replaced.

Casualty record · 6

20 March 2011Routine · role: Transiting Vicinity of Primary Subject · activity 3975000
31 May 2013Routine · role: Transiting Vicinity of Primary Subject · activity 4624206
15 November 2016Routine · role: Transiting Vicinity of Primary Subject · activity 6041473
17 February 2020Routine · role: Transiting Vicinity of Primary Subject · activity 6911468
14 December 2022Routine · role: Involved in a Marine Investigation (non-casualty) · activity 7609462
2 February 2026Routine · role: Involved in a Marine Casualty · activity 8325132
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.