Records from 2010 to 2026. Most recent: inspection, 5 March 2026.
Documentation record
Registered dimensions (L × B × D)67.2 ft × 26.0 ft × 9.0 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)67.2 ft × 26.0 ft × 9.0 ft
ITC tonnageNot recorded
BuilderNICHOLS BOAT COMPANY · GREENVILLE, MS, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMEMPHIS, TN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 March 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
5 March 2026
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8320317
2 February 2026
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8325132
13 February 2025
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8079183
11 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7893557
11 March 2024
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7877396
15 February 2023
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7637301
14 December 2022
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7609462
28 March 2022
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7419963
24 March 2021
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7169778
19 February 2020
Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6911696
17 February 2020
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6911468
15 November 2016
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6041473
31 May 2013
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4624206
20 March 2011
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3975000
18 March 2011
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3967431
3 March 2011
Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3956545
8 June 2010
Administration · Industry Initiated Exam · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3761878
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 February 2023
Resolved
Paints, coatings and other flammable or combustible products must be stored in a designated storage room or cabinet. If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not not move and must be either:
Meet UL 1275 Standards
Meet FM approval Standard 6050 or,
Another steel container that provides equivalent level of protection.
Flammable and combustible liquids are being stored in starboard push knee. Push knees are completely open to atmosphere. Current storage arrangements do not provide equivalent level of safety.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2023
Resolution: Installed UL approved flam locker.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 15 February 2023
Resolved
A navigation assessment entry must be recorded in the vessel log book. The entry must include the date and time of assessment, the name of individual making assessment, and the starting and ending points of the voyage or trip that the assessment covers. There are no logs indicating that navigation assessments are being conducted. Provide objective evidence that person in charge of the navigation watch is conducting navigation inspections in accordance with all requirements listed in 46 CFR 140.635.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2023
Resolution: Operator provided several days of vessel logs showing nav assessments are being completed
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 15 February 2023
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to the crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed railed. Aft deck does not have any fall overboard protection. Install stanchion and chain system as discussed with Marine Inspector. If a different system than discussed is going to be installed, contact Marine Inspector for approval prior to its instillation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2023
Resolution: Installed stanchion and cable system.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 15 February 2023
Resolved
Each towing vessel must be equipped with the following alarms: Maine engine and generator engine high cooling water temperature. Main engine and generator engine low lube oil pressure alarm. High bilge level alarm. Low hydraulic steering fluid level alarm. Low fuel level alarm if fitted with a day tank. Additionally, in accordance with table 143.245(b), alarm set points must be tested twice every 5 years, with no more than 3 years elapsing since last testing. Crew was unable to test generator alarm set points or steering fluid level alarm.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2023
Resolution: Tested alarms. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 February 2023
Resolved
46 CFR 141.340 Each life jacket must have a light approved under under approval series 161.012 or 161.112 securely attached to front shoulder area of life jackets. Life jacket must be removed from service until it can be fitted with light. Vessel is limited to carrying no more than 07 total persons until life jacket is placed back into service.
46 CFR 140.430: When worn at night, work vest must be equipped with light that meets requirements of 141.340. Found 04 work vest without lights. Work vest must not be worn at night until equipped with approved lights.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2023
Resolved 14 March 2023
Resolution: Received copy of purchase receipts for life jacket lights and photo showing lights attached to life jacket and work vest.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 22 April 2022
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention.
Engine room bilge high level alarm inoperable.
Vessel is authorized to continue to operate with hourly engine room rounds being made by the crew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 26 April 2022
Resolution: Engine room bilge high level alarm replaced and tested satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 April 2022
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards.
Replace broken light covers in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 26 April 2022
Resolution: Light covers replaced.
20 March 2011Routine · role: Transiting Vicinity of Primary Subject · activity 3975000
31 May 2013Routine · role: Transiting Vicinity of Primary Subject · activity 4624206
15 November 2016Routine · role: Transiting Vicinity of Primary Subject · activity 6041473
17 February 2020Routine · role: Transiting Vicinity of Primary Subject · activity 6911468
14 December 2022Routine · role: Involved in a Marine Investigation (non-casualty) · activity 7609462
2 February 2026Routine · role: Involved in a Marine Casualty · activity 8325132
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.