Records from 1992 to 2024. Most recent: inspection, 7 September 2024.
Documentation record
Registered dimensions (L × B × D)55.0 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 81 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHEO CHAISSON · HOUMA, LA, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portMEMPHIS, TN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Simplified, Net Ton
81 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 43
7 September 2024
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8013259
29 May 2024
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7954446
26 January 2024
Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7856112
7 November 2023
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7821504
24 September 2022
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7567107
9 August 2022
Deficiency Check · Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7529695
9 August 2022
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7535362
7 October 2021
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7330783
7 January 2021
TPO Audit
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7135259
25 November 2019
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6862135
9 November 2018
Damage Survey · Examination of Repairs
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6580521
9 November 2018
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6587444
12 October 2018
Initial Certification · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6561277
9 October 2018
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6558308
12 April 2018
Industry Initiated Exam · Administration · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6390561
30 March 2018
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6388875
14 March 2018
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6371965
5 October 2017
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6281935
28 August 2017
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6253762
14 September 2015
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5718762
9 May 2015
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5123673
15 April 2015
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5138183
1 December 2014
Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5032184
5 October 2014
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5064001
6 August 2014
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4953702
12 September 2012
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4467594
13 June 2011
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4043534
19 May 2011
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4021682
8 December 2010
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3907176
17 September 2008
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3338947
3 October 2005
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2507826
3 May 2005
Administrative Inspection
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2348963
15 November 2004
MTSA Verification
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2241049
8 March 2004
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2020318
4 March 2004
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2017946
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971770
11 January 2001
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 73448
9 January 1998
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 42704
18 November 1997
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 410163
26 November 1996
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 410521
6 August 1995
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 56735
6 August 1995
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 121711
19 June 1992
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 33656
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2024
Resolved
Machinery systems must be designed and maintained to provide for safe operation of the vessel and safety of persons onboard under normal and emergency conditions. Vessel suffered casualty to port reduction gear causing loss of propulsion to the port shaft. Make repairs to the satisfaction of vessel Third Party Organization, Towing Vessel Inspection Bureau (TVIB).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 November 2023
Resolved
Alarms must be visible and audible at each operating station. Vessels summary alarm at operating station did not have audible or visual. Alarm could be heard from below deck, but visible and audible must be present at operating station. Vessel shall make repairs to the satisfaction of the local OCMI.
46 CFR 143.230(b)(1)
Action required: 60 - Rectify deficiencies prior to movement
Due 20 December 2023
Resolved 22 November 2023
Resolution: Vessel discovered disconnected wire on light. Reconnected, test SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 November 2018
Resolved
Fuel leaking from hull on STBD side rear quarter near waterline.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 9 December 2018
Resolved 29 November 2018
Resolution: Hull cropped and renewed IAW with NVIC 7-68 with 24"x 24" plate.
Navigation
Issued 18 November 1997
Resolved
MAGNETIC COMPASS WAS MISSING FROM BRIDGE.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997