MAURY USCG vessel records Sign in
← All vessels

THE HICKMAN

THE HICKMAN is a 1996 passenger barge (inspected). The Coast Guard has recorded 40 inspections since 1996, most recently in March 2015, along with 23 deficiencies and 3 casualty investigations between 2006 and 2012.

Records from 1996 to 2015. Most recent: inspection, 4 March 2015.

Built
1996
Last inspected
4 March 2015
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

435670
Flag
UNITED STATES
—
Maury page id
psix-435670

Inspections, by type

…with no type recorded6
Years with a record 18 calendar years (1996–2015)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)78.0 ft × 32.0 ft × 4.8 ft
Registered tonnagegross 99 / net 99
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERODINO, INC. · GUILD, TN, UNITED STATES · built 1996
Hull materialSteel
PropulsionNone
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger Barge (Inspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Simplified, Gross Ton
99 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BILL WEPFER Towing Vessel · MISLE 331366 · 12 September 2012 · activity 4467594MARILYN RONCALI Towing Vessel · MISLE 98281 · 3 October 2007 · activity 3073601TERAH HUCKABEE Towing Vessel · MISLE 149090 · 3 October 2007 · activity 3073601DEANA ANN Towing Vessel · MISLE 187789 · 3 October 2007 · activity 3073601

Inspection history · 40

4 March 2015 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5078026
19 August 2014 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4960353
6 August 2014 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4946277
18 March 2014 Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4818589
7 August 2013 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4678787
12 September 2012 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4467594
14 June 2012 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4343172
12 July 2011 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4078867
30 November 2010 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3901409
10 March 2010 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4078791
13 February 2009 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3419879
27 August 2008 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3310692
3 October 2007 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3073601
11 July 2007 Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3113513
30 May 2007 COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2945323
22 May 2007 Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2937542
12 January 2007 Examination of Repairs
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2854850
15 December 2006 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2846267
10 August 2006 Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2741796
10 December 2004 Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2258145
18 August 2004 Periodic Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2170793
26 August 2003 Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1888881
3 June 2002 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1625645
3 June 2002 Administrative Inspection
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1636509
26 September 2001 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 772512
22 August 2001 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 215048
22 August 2001 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1463697
9 November 2000 Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1057337
20 June 2000 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 819097
20 June 2000 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1053319
20 June 2000 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1395476
24 June 1999 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1193283
25 May 1999 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1424761
14 October 1997 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 774230
8 October 1997 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 774329
21 July 1997 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1378113
27 March 1997 Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1094184
6 February 1997 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1103020
12 September 1996 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 954548
31 July 1996 Initial Certification · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1264983

Deficiency record · 23

Fire Fighting › Fire Hoses › Material
Issued 7 August 2013 Resolved
Replace current fire hoses and nozzles with those that meet 46 CFR 181.320.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 September 2013
Resolved 4 September 2013
Resolution: Fire hoses and nozzles replaced.
Stability › Water on Deck › General
Issued 7 August 2013 Resolved
Conduct training on stability letter requirements.
Action required: 705 - Other - as specified
Due 6 September 2013
Resolved 4 September 2013
Resolution: Verified operators knowledge of stability letter requirements.
Personnel › Training › Fire Fighting Basic
Issued 7 August 2013 Resolved
Conduct and log man overboard and fire drills.
Action required: 705 - Other - as specified
Due 6 September 2013
Resolved 4 September 2013
Resolution: Conducted man overboard and fire drills, All sat.
Engineering › Bilge Water Management System › Manifold
Issued 7 August 2013 Resolved
Label all bilge suction lines.
Action required: 705 - Other - as specified
Due 6 September 2013
Resolved 4 September 2013
Resolution: Bilge suction lines labeled.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 June 2012 Resolved
Mounting bracket and belly bands missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2012
Resolved 22 June 2012
Fire Fighting › Nozzles › Type
Issued 14 June 2012 Resolved
Nozzel unable to provide a solid stream and spray pattern.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 June 2012
Resolved 14 June 2012
Resolution: Corrected on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 June 2012 Resolved
2 of 4 navigation lights were extinguished.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2012
Resolved 14 June 2012
Resolution: Corrected on the spot
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 June 2012 Resolved
Special Flashing Light is not displayed IAW Navigation Rule 21 (g) and Rule 24 (f) (ii)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 August 2012
Resolved 6 August 2013
Resolution: Special flashing light was installed IAW Navigation Rule 21.
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 14 June 2012 Resolved
Repair or replace dry rotted line around the life rings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2012
Resolved 22 June 2012
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 14 June 2012 Resolved
Remove hydraulic fluid from hydraulic pump box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2012
Resolved 22 June 2012
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 14 June 2012 Resolved
Post Emergency instructions at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather or man overboard conditions. I. A. W 46 CFR 185.10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2012
Resolved 22 June 2012
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 June 2012 Resolved
Vessels operating with an expired COI
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2012
Resolved 14 June 2012
Resolution: Vessel was issued a new COI. After discussed violation with the SIO, it was decided a resolution would be better served by training.
Engineering › Diesel Engine (propulsion-reduction gear) › Piston
Issued 27 August 2008 Resolved
Repair/replace port MDE on the towing vessel Dorena II for proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2009
Resolution: Port MDE rebuilt, tested sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 27 August 2008 Resolved
Have all F/F equipment serviced annually.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2009
Resolution: All F/F equipment serviced by third party, documentation viewed.
Engineering › Bilge Water Management System › Not Operational
Issued 27 August 2008 Resolved
Provide operational bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2009
Resolution: Witnessed operational test of bilge pump.
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 August 2008 Resolved
Conduct all required drill in the presence of a CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2009
Resolution: Witnessed all required drills.
Deck/Cargo › Cargo Stowage › General
Issued 30 May 2007 Resolved
Properly weld repair damaged aft vehicle loading ramp prior to using ramp.
Due 24 June 2007
Resolved 13 June 2007
Construction/Loadline › Structures › Deck Plating
Issued 22 May 2007 Resolved
Properly weld repair broken ramp welds prior to allowing vehicle traffic on ramp. Repairs are to be made to the satisfaction of the attending Coast Guard Marine Inspector.
Due 22 June 2007
Resolved 11 July 2007
Construction/Loadline
Issued 22 August 2001 Resolved
Repair/replace and prove proper operation of fixed bilge pumping system to the satisfaction of the attending Coast Guard Marine Inspector. Until thattime a second portable system must remain onboard at all times.
Condition: Unknown
Due 22 August 2001
Resolved 22 August 2001
Fire Fighting
Issued 25 May 1999 Resolved
AFT FIRE HOSE HAS PIN HOLE LEAK. REPLACE WITH UL APPROVED, LINED, 50" LENGTH, 1.5" DIAMETER FIRE HOSE.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Electrical
Issued 25 May 1999 Resolved
Support overhead electrical wiring to ramp motor in #7 void every 24".
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Navigation
Issued 21 July 1997 Resolved
PROVE PROPER SUSTAINED OPERATION OF ALL NAVIGATION LIGHTS ONBOARD THE M/V DORENA AND FERRY BARGE THE HICKMAN. UNIT SHALL NOT OPERATE DURING CONDITIONS THAT REQUIRE NAVIGATION LIGHTS UNTIL CORRECTED.
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997
Fire Fighting
Issued 27 March 1997 Resolved
A LEAK IN A "T" CONNECTION IN THE PIPING SYSTEM FOR THE FIRE SYSTEM WAS FOUND BY COMPANY PERSONNEL.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997

Casualty record · 3

15 December 2006Routine · role: Involved in a Marine Casualty · activity 2846267
3 October 2007Routine · role: Sighted in Area · activity 3073601
12 September 2012Routine · role: Transiting Vicinity of Primary Subject · activity 4467594
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record